Loading...
HomeMy WebLinkAbout13-14840 CITY OF ZEPHYRHILLS 5335-8TH STREET (ss3)�so-oo20 14840 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL � y�,;µ� � ,� � ��.��� � �;m. Permit#:14840/14839 Issued: 12/20/2013 Address: 37845 PRAIRIE ROSE LP LT 26 Permit Type: GENERAL BUILDING PERMIT ZEPHYRHILLS, FL. Class of Work: 105-NEW CONST/MULTI 5+ UNIT Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: Total Fees: 8,386.37 Subdivision: WALNUT GROVE TOWNHOMES Amount Paid: 8,386.37 Date Paid: 12/20/2013 Parcel Number: 15-26-21-0030-06600-000 3, � _���. Name: BAILEY CONTRACTING LLC � Name: BUTTERFIELD MOBILE HOME Addr: 4209 GALL BLVD Address: 4034 GALL BLVD ZEPHYRHILLS, FL 33542 ZEPHYRHILLS Phone: (813)377-7395 Lic: Phone: (813)973-5250 Work Desc: NEW CONSTRUCT 4 UNIT TOWNHOME (#2 UNIT) � -. � , y. , . i: .w �.�,, � ; � � � . � a„� , , �.,�: � ��w , �:'. ���, IL I E 330.69 ELE I AL 69.64 L I 4 . 3 MECHANICAL FEE 32.50 SEWER CONNECTION RESIDEN" 2,010.00 WATER CONNECTION RESIDENI 641.00 WATER METER RES 3/4" 348.09 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5°/a 26.35 PARK FEES TOWNHOMES 769.56 SCHOOL IMPACT FEE-sfr/100% 0.00 SCHOOL IMPACT FEE-sfr/1% 0.00 TRAFFIC IMPACT FEE 99% 3,445.20 TRAFFIC IMPACT FEE 1% 34.80 FIRE PLAN REVIEW FEES 105.11 , I I j � � I ! �I �t�'�1� ��� u � � � � � , :. ,"+�:� a�.,, �����r s �� �S� �,;Ay�, �,..,, ,��� � �. s': 2ND U H PLUM IN ULA I N IL N FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80 (2)(c)when extra inspection trips are necessary due to any one of the following reasons: a) wrong address b)condemned work resulting from faulty construction c) repairs or corrections not made when inspections called d) work not ready for inspection when called e) permit not posted on job site� plans not at job site g) work not accessible. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications and Must Accompany Application. All work shall be pertormed in accordance with Ci Codes and Ordinances. NO OCCUPANCY BEFORE C.O. SC��" �;Q-- ` ylC� , � CONTRACTORS ATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER CITY OF ZEPHYRHILLS 5335-8TH STREET (sis)�so-oo20 14840 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL Permit#:14840 Issued: 12/20/2013 Address: 440 URT ST, Permit Type: GENERAL BUILDING PERMIT ZEPW F . Class of Work: 105-NEW CONST/MULTI 5+ UNIT Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: Total Fees: 8,386.37 Subdivision: CITY OF ZEPHYRHILLS Amount Paid: 8,386.37 Date Paid: 12/20/2013 Parcel Number: 15-26-21-0030-06600-0000 Name: BAILEY CONTRACTING LLC Name: BUTTERFIELD MOBILE HOME Addr: 4209 GALL BLVD Address: 4034 GALL BLVD ZEPHYRHILLS, FL 33542 ZEPHYRHILLS Phone: (813)377-7395 Lic: Phone: 813-973-5250 Work Desc: NEW CONSTRUCT 4 UNIT TOWNHOME (#2 UNIT) MECHANICAL FEE 32.50 SEWER CONNECTION RESIDEN" 2,010.00 WATER CONNECTION RESIDENI 641.00 WATER METER RES 3/4" 348.09 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES TOWNHOMES 769.56 SCHOOL IMPACT FEE-sfr/100% 0.00 SCHOOL IMPACT FEE-sfd 1% 0.00 TRAFFIC IMPACT FEE 99% 3,445.20 TRAFFIC IMPACT FEE 1% 34.80 FIRE PLAN REVIEW FEES 105.11 FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80 (2)(c)when extra inspection trips are necessary due to any one of the following reasons: a) wrong address b)condemned work resulting from faulty construction c) repairs or corrections not made when inspections called d)work not ready for inspection when called e) permit not posted on job site� plans not at job site g)work not accessible. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications and Must Accompany Application.All work shall be pertormed in accordance with Ci Codes and Ordinances. NO OCCUPANCY BEFORE C.O. C TRACT S SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER � � � � � d � � � � � � � o � � � C x a .� r � dd � � � � � � � � � d � � � o rG � � o � z � � � r � N ro n z z N � � � n � � ~ "' � 0 0 °o %� r � (� ''C ° � � W O � � o � `-� U� � n ° °` r C� r � °o � � � � � N � � �U � °� � x x � � o � � ---, '� � x - , � , � � ,, �- :' o � � � � � ro � � � r � � � � o z d � o � r � �. z d � o � � � � Z N " O � � � � � J � � � � � � ►y 0 C (D � O � � � O � c'D � 4408 COURT ST-BAILEY CONTRACTING LLC 4UNIT TOWNHOME units-2-4 SQ. FEET PRICE MAIN OR LIVING: OTHER AREA UNDER ROOF: - OTHER: - $ _ VALUATION FEE SHEET ADDRESS DRIVEWAY BUILDING: $ 330.69 ELECTRICAL: $ 69.64 PLUMBING: $ 46.43 MECHANICAL: $ 32.50 SUB-TOTAL $ 479.26 TOTAL S 479.26 SEWER: $ 2,010.00 WATER: $ 641.00 IRRIGATION: $ - TOTAL: S 2,651.00 WATER METER: $ 348.09 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: $ 105.11 INSPECTION TOTAL: PERMIT TOTAL TOTAL: S 105.11 PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: E 553.35 S U B-TOTAL $ 4,136.81 PARK IMPACT FEES $ 769.56 SIF'S: $ 1,757.40 100.0% $ 1,740.00 1.0% $ 17.40 TOTAL: a 7,757.40 T I F'S: a 3,480.00 99% $ 3,445.20 1% $ 34.80 TOTAL: $ 10,143.77 FORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTtON F/orida Department of 8usiness and Professiona/Regulation -Residentia!Performance Method Pro%ect Name: Walnut Gmw TH 1129 N 8ulldsrNama: {jcL,�Py (Gr'���`�r�G L l � SHeet. 4408 Court Sbeet Permit Oflice: Zephyrh/lls ��'�-� � City,Shte.Zip: Zephyrhills,FL,335t2- Psrm/tNumber. I '-��4 U Owner. Judsdlction: B1J600 DeslgnLocatlon: FL,Tampa ' 1. New construction or exls8ng New(From PfansJ 8. Wal!Typss(688.0 sq1l:) InsulaHon Area 2. Slnqla familyormul�ple famlly Multl-fam4y 8•����8b�-�nt lnsui,Exteria R=4.0 381.98 R' b.Frsme-Wood,Adjecent R=1 f.0 214.64 fl' 3. Numberofunits,ilmultipbfamily 9 c.ConC�ste8loCk-Intlnsuf,Adfecent R=4.0 92.00R` 4. NumberofBedrooms 2 d.AUA R_ � . 5. Js thisa worstcase9 No 10.CeJlinQTyp9s (?129.0 sq11`.) Insulatlon Area a.UntlerAtdc(Vented) R=30.0 1129.00 R' 6. CondlHoned Aooiaroa above grade(Il�) 1129 b.N/A R= 1N CondifionedRoorareabelowprede(ft=) 0 a N/A R= 1t= . i 1.DuCts R /N 7. �ndows(65.2 sqfC.) Description Aree a.Sup:Attic,Ret MVAC 1,AH:HVAC 1 6 172 a. f�Factor. Obl,U=0.50 65.19 ft' � SNGC: SNGC=0.50 b. U-Factor. N/A � 12•CoollnqsYsfems kBtwhr Elficiexy SHGC: a.CentralUnit 18.6 SEER:14.00 c. U-Factor: N/A tN � SHGC: J3.Heatlngsystems kBtWhr ElAdency d. U-FaCtor: N/A ft' a.Elechic Heat Pump� i7.6 HSPF.8.20 SHGC: Area Weighted Av�erage Overtrang Depth: 5.0.?2 R. A�saWeiqhtedAverege SNGC: p,5pp 14.Hotwatersystems 8. FloorTypes (7129.0 sqft) lnsuladon Area a.Elechic Cap:40galJons a.Sfab-OfrGredeEdgelnsulation R=0.0 1129.00fN EF:0.920 b. Conserva6on featuroa b.N/A 1?z R' None .. C.N/A R= �' 15.Credlts Pstet Glass/FloorArsa: 0.058 Tota!Proppsed Mod�ed Loads: 21.96 pASS Tota/Sfandard Reference Loads: 39.04 1 hereby certily that the p! s and specificaSons covered by Review of the�ans and 0��1�8 S7'� this calculation are in� ia wlth the Florfda Energy specifications covered 6y this ' ��Y p� Code. ' calculaBonindicatescomplfance , g' � � � � " with the Florida Energy Code. � �� a PREPAR ��' � eefore constnrction is completed � �° p c' DATE: �1� .'� ., . � . thls building will be inspected for , c� ..�` . - a � compliance wifh Section 553.905 x • � !hereby cerfily thaf this�building,�s designed,is in complisnce Florida Sfatutes. - �, � with the Florida Energy Code. �'O,p��� OWNER/AGENT: BUILDING OFFlC1AL: DATE: DATE: , - Compliance requires cartification by the�alr handler unit manutacturer that the air handferenctosure qualities as - certlfied factory�ealed in accordance with 403.2.2.4.1. , - Compliance requires completlon of a Florida Air Barrier and Insulatlon Inspection Checklist 1?/42013 12:22 PM EnergyGaupe�USA-FlaRes20?0 Sxfion 405.4.1 Compliant Soltware Page t of 5 , 1 .. . , - . - _ _.._ . _.. .. . . ._:._._,,._...�.: ��.-.._ PROJECT Title: Wa/nuf Grove TH 1129 N Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1129 Lot� Owner: Tota/Stories: 1 BIocWSubDivision: #of Unds: 1 Worst Case: No P/atBook: Builder Name: Rotate Ang/e: 0 Street: 4408 Court Street PermR OHice: Zephyrhills Cross Ventilation: County: Pasco Jurisdiction: 6116Q0 Who/e House Fan: Cdy,State,Zip: Zephyrhills, Family Type: Mu/ti-family FL, 33542- New/Existing: New(From P/ans) Comment: CLIMATE / IECC Desgn Temp Int Desgn Temp Hea6ng Desgn Daiy Temp V Design Locatan TMY Srte Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Tampa FL_TAMPA_INTERNAT/O 2 39 91 72 75 645.5 54 Medium BLOCKS Number Name Area Vo/ume 1 Block 1 1129 9032 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infi11D Finished Cooled Heated 1 HVAC 1 1129 9032 Yes 3 2 1 Yes Yes Yes FLOORS # Fbor Type Space Perimeter R-Value Area Ti/e Wood Carpet 1 Slab-On-Grade Edge lnsulata HVAC 1 86 R 0 1129 itP ____ 0.4 0.4 0.2 ROOF / Roof Gable Roof So/ar SA Emitt Emitt Deck Pitch \� # Type Maferials Area Area Cobr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1190 HZ 0 itz Dark 0.96 No 0.9 No 0 f8.4 ATTIC V # Type Ventilatan Vent Ratio(1 in) Area RBS lRCC 1 Full attic Venfed 300 1129 ft2 N N CEILING # Ceiliny Type Space R-Value Area Framing Fiac Truss Type 1 Undei Attic(Vented) HVAC 1 30 1129 ft2 0.11 Wood 11/4/2013 12:23 PM EnergyGauge�USA-FlaRes2010 Sectan 405.4.1 Compliant Softwa�e Page 2 of 5 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 _ 1 W Garage Frame-Wood HVAC 1 11 3.33 0 8 0 26.6 fr2 0 0.23 0.01 0 _ 2 N Garage Frame-Wood HVAC 1 11 3.17 0 8 0 25.4 ft2 0.23 0.01 0 _ 3 W Garage Frame-Wood HVAC 1 11 12 0 8 0 96.0/tT 0 0.23 0.01 0 _ 4 N Exterior Concrete Bbck-Int Insul HVAC 1 4 4 0 8 0 32.0 itz 0 0 0.35 0 _ 5 N Exterior Conaete Bbck-lnt/nsul HVAC 1 4 10.17 0 8 0 81.4 R2 0 0 0.35 0 _ 6 E Garage Concrete B/ock-Int/nsul HVAC 1 4 11.5 0 8 0 92.0 It2 0 0 0.01 0 _ 7 N Garaqe Frame-Wood HVAC 1 11 8.33 0 8 0 66.6 It2 0.23 0.01 0 _ 8 S Exterior Concrete Bbck-Int Insul HVAC 1 4 13.17 0 8 0 105.41t2 0 0 0.35 0 _ 9 S Exterior Concrete Bfock-lnt Insu/ HVAC 1 4 12.5 0 8 0 100.01t2 0 0 0.35 0 _ f 0 W Exter'ar Concrete Bbck-Int Insul HVAC 1 4 7.83 0 8 0 62.6 R2 0 0 0.35 0 DOORS �t Ornt Door Type Space Storms U-Va/ue W�dth Height Area Ft /n Ft fn 1 W /nsulated HVAC 1 None 0.35 3 0 6.67 0 20.01000 2 N lnsulated HVAC 1 None 0.35 3 D 6.67 0 20.01000 WINDOWS Orientation shown is the entered,Proposed orientatan. � Wa/l Overhang # Ornt !D Frame Panes NFRC U-Factor SHGC Area Depth Separation Inf Shade Screening 1 N 5 TIM Low-E Doub/e Yes 0.5 0.5 16.21tz 1 R 0 in 1/t 0 in Drapes/blinds Exteiar 5 2 S 8 TIM Low-E Double Yes 0.5 0.5 20.0 RZ 9 ft 0 in 0 It 0 in Drapes/blinds None 3 S 8 T1M Low-E Double Yes 0.5 0.5 12.8 ff2 9 ft 0 in 0 ft 0 in Drapes/blinds Exterar 5 4 S 9 T!M Low-E Double Yes 0.5 0.5 16.2 ff2 1 ft 0 in 1 ft 0 in Drapes/blinds Exte�ar 5 GARAGE # Fbor Area CeiGng Area Exposed Wal/Perimeter Avg. Wal/Height Exposed Wall lnsulatan 1 256 Rz 256 ft2 41 ft 8 ft 0 INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Best Guess 0.000300 888.415 48.772B 91.7244 0.22500 5.90178 HEATING SYSTEM # System Type Subrype Eff�iciency Capaciry Block Ducts (�nvaliElectric Heat Pump None HSPF:8.2 17.6 kBtu/hr 1 sys#1 1 J/4/2013 f2:23 PM EnergyGauge�USA-FfaRes2010 Sectbn 405.4.1 Compliant Software Page 3 of 5 COOLING SYSTEM � System Type Subtype EH'�ciency Capacity Air Fbw SHR Bbck Ducts �nvaliCentra/Unit None SEER:14 18.6 kBtu/hr 558 clm 0.75 1 sys#1 HOT WATER SYSTEM # Sysiem Type SubType Location EF Cap Use SetPnt Conservatbn 1 E/ectric None Garage 0.92 40 ga/ 50 ga/ 120 deg None SOLAR HOT WATER SYSTEM FSEC Copector Storage CeR �Y Company Name System Model# Collector Model# Area Volume FEF None None n2 DUCTS � ----Suppty---- ----Return---- Air CFM25 HVAC# # Location R-Va/ue Area Location Area Leakage Type Handler C/FdbPS OUT QN RLF Heat Cool (fnvali Att� 6 172/tz HVAC 1 15112 Defau/t Leakage HVAC 1 (invalid)cf(Default)c 1 1 TEMPERATURES Programable Thermostat: Y Cei6ng Fans: Coobng 1Jan ]Feb )Mar Apr May ( Jun X Ju/ Au X Se Oct Nov Dec Heating X Jan f X]Feb f X]Mar �(�j Apr �(i May [�Jun [i Jul �(�Aug �}Sep ��Oct f Xj Nov f�Dec Venting j Jan [J Feb jXJ Mar jX]Apr (J May j Jun (]Jul j Aug ]Sep Oct jXJ Nov [ Dec Thermastai Schedu/e: HERS 2006 Re%rence Hours Schedule Type 1 2 3 4 5 6 7 8 9 f 0 11 12 Cooling(WDJ AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 7B 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 7B 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 11/4/2013 12:23 PM EnergyGauge�USA-FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5 FORM 405-10 Florida Code Compliance Checklist - F/orida Department of Business and Professional Regulations Resrdenfial Whole Building Performance Method ADDRESS: 4408 Court Street PERM/T#: Zephyrhills,FL,33542- MANDATORY REQUIREMENTS SUMMARY-See Individual code sections for full details. COMPONENT SECTION SUMMARYOF REQUIREMENT(S) CHECK Airleakage 402.4 To be caulked,gasketed, weafherstripped orotherwise sea/ed. Recessed lighting 1Grated as meeting ASTM E 283. Windows and doors=0.30 cfm/sq.ft. Testing or visua!inspection r�equired. ✓ Fir+ep/aces:gasketed doors&outdoor combustion air. Must complefe envelope/eskage report or visually verify Table 402.4.2. Thermostat 8 403.1 Atleast one them►osfaf shal!be provided for each separate heating controts and cooling system. Where forced-afr fumace is primary system, • / prag�ammab/e thermostat is required.Heat pumps with supplemental � e/ectric heat must pnevent supplementa/heaf when compressor can meet the load. Ducts 403.2.2 All ducts, airhandlers, filterboxes and 6uilding cavities which form the � primary arr containmenf passageways for air distribufion systems shall be considered ducts or plenum chambers,shel!be constructed and � sea/ed in accorrlance with Section 503.2.7.2 of fhis code. 403.3.3 8uilding framing cavities shal!not be used as supp/y ducts. Water heaters 403.4 Heat trap requirtsd for vertica!pipe risers. Comply with e�ciencies in Table 403.4.3.2.Provide swifch or clea�ly maiked eincuit breaker .1/ (electria)or shutoff(gas). Ci�u/ating system pipes insufated to= R-2+accessib/e manua!OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical venUlation ventilation systems shal!not exceed the minlmum ASHRAE 62/evel. " . No make-up air from attics,crawlspaces,garages or outdoors adjacenf ✓ . to pools or spas. J��� - SwimmingPools 403.9 'Poo/pumps and poo/pump motors with a tota!horsepower(HP)nf= 1 &Spas ,. HP`shalf have the capabilrfy of oper�ting at fwo or more speeds. Spas � , " and heated poo/s musf have vapor-retandant covers or a Ifqpid cover or� , � • , — other means proven to reduce heat loss except if 709�o af heat from � , site-necovered energy. Ofl'�timer switch r�qu/red. Gas heafers minimum `��- therma!e�ciency=78�(82%after 4/16/13). Heat pump pool heaters , � " minimum COP=4.0. Cooling/headrlg 403.6 Sizing calculation performed&attached. Minimum efficiencies per �Tab/es 503.2.3.Equipment e�ciency verif/cation reyuired. Specia/ � equipment odl�asion cooling or heating capacity requires separate system or variable capacity system. E/ectric heat>10kW must be divided into two or mone stages. � CeJlings/kneewa!!s 405.2.1 R-19 space permitting. 11/4r101312:22 PM EnerpyGauqe�USA-FlaRes20f 0 Secfion 405.4.1 Complisnt SoA'waro Paqe 5 of 5 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX'' = 71 The lower the EnergyPerformance lndex, the more efficient the home. 4408 Court Street, ZephyrhiUs, FL, 33542- 1. New construction or existing New(From P/ans) 9. Wall Types lnsu/ation Area 2. Sing/e family or mu/tiple family Mu/ti-famity a.Concrete Block-Int Insul,Exterior R=4.0 381.36 Rz b.Frame-Wood,Adjacent R=11.0 214.64 ftp 3. Number of unils,if multiple family 1 c.Concrete Bbck-Int Insul,Adjacent R=4.0 92.00 R? 4. Number of Bedrooms 2 d.N/A R= ft� 10.Ceiling Types Insu/atan Area 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1129.00 lt� 6. Cond'dioned Boor area(ft?) 1129 b.N/A R= Itz 7. Windows'" Descriptron Area c.N/A R= 1t�2 a. U-Factor: Dbl,U=0.50 �,�g ftz 11•Ducts R ft a.Sup:Attic,Ret:HVAC 1,AH:HVAC 1 6 172 SHGC: SHGC=0.50 b. U-Factor: N/A ft2 SHGC: 12.CooNng systems kBtu/hr Efficiency c. U-Factor: N/A Rz a.Central Unit 18.6 SEER:14.00 SHGC: d. U-Factor: N/A h2 i3.Heating systems k8tu/hr EH'rciency SHGC: a.Electric Heai Pump 17.6 HSPF:8.20 Area Weighted Average Overhang Depth: 5.032 ft. Area Weighted Average SHGC: 0.500 8. Floor Types lnsu/atan A�ea 14.Hot water systems a.S/ab-On-Grade Edge Insu/atbn A=0.0 1129.00 RZ a.Electric Cap:40 galbns EF:0.92 b.N/A R= RZ c.N/A R= hz b. Conservatbn features None 15.Credits Pstat 1 certify that this home has complied with the Florida Energy Efficiency Code for Building � Construction through the above energy saving features which will be insfalled(or exceeded) 04�s a in this home before final rnspection. Otherwise, a new EPL Disp/ay Card will be completed �� �� "'�'� based on installed Code compliant features. +`^� `�` � Builder Signature: Date: � > . � Address of New Home: Cify/FL Zip: �. C�4 yWE3'l'�'� "Note: This is not a Building Energy Rating. If your Index is be/ow 70,your home may qualify for energy efficient mortgage(EEM)incentives if you obtain a F/orida EnergyGauge Rating. Contact the EnergyGauge Hotline af(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. ""Label requrred by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge�USA-F/aRes2010 Sectbn 405.4.1 Comptiant Soflware TABLE 402.4.2 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Wa/nut Grove TH 1129 N Bur�der Name: Street: 4408 Court Sbeel Permd OffJce: Zephy�hil/s City,State,Zip: ZephyihiNs,FL,33542- Permd Number: Owner: Jurisdictan: 611600 Design Location: FL, Tampa COMPONENT CRITERIA CHECK Air barrier and thermal barrier Exterior thermal envelope insulation for framed walls is installed in substantial contact and continuous alignment with building envelope air barrier. Breaks or joints in the air barrier are fiNed or repaired. Air-permeable insulation is not used as a sealing materral. Air- ermeable insulation is inside of an air barrier. Ceiling/attic Air barrier in any dropped ceiling/soffit is substantially aligned with insulation and any gaps are sealed. Attic access(except unvented attic), knee wall door, or drop down stair is sealed. Walls Corners and headers are insulated. Junction of foundation and sill plate is sea/ed. Windows and doors Space between window/door jambs and framing is sea/ed. Rim joists Rim joists are insulated and include an air barrier. Floors (including Insulation is installed to maintain permanent contact with underside above-garage and of subfloor decking. cantilevered floors) Crawl space walls Insulation is permanently attached to walls. Exposed earth in unvented crawl spaces is covered with CJass I Shaits,penetrations Duct shafts, utility penetrations, knee walls and flue shafts opening to exterior or unconditioned space are sea/ed. Narrow cavities Batts in narrow cavities are cut to fit, or narrow cavities are filled by sprayed/blown insulation. Garage separation Air sealing is provided between the garage and conditioned spaces. Recessed lighting Recessed light fi�ures are air tight, IC rateal, and sea/ed to drywall. Exception--fixtures in conditioned space. Plumbing and wiring Insulation is p/aced between outside and pipes. Batt insulafion is cut to fit around wiring and plumbing, or sprayed/blown insulation Shower/tub on exterior wall Showers and tubs on exterior walls have insulation and an air barrier se aratin them from the exterior wall. Elecfrical/phone box on Air barrier extends behind boxes or air sealed-type boxes are insfalled. Common wall Air barrier is installed in common wall between dwelling units. HVAC register boots HVAC register boots that penetrate building envelope are sealed to subfloor or d all. Fire lace Fire /ace walls include an air barrier. EnergyGauge�USA-FlaRes20f0 Section 405.4.1 Compliant Software Rhvac-Residential&Light Commercial HVAC Loads � Elite Software Development,Inc. HVAC Designs Walnut Grove TH 1129 N Tam a,FL 33615 Pa e 1 Pro'ect Re ort General Pro ect Information Project TiUe: Walout Grove TH 1129 N Project Date: Saturday,November 02,2013 Company Name: HVAC Designs Inc Company Representative: Neil Fimbel Company Address: 7701 W Hanna Ave Company City: Tampa FL 33615 Company Phone: (613)885�2258 Company E•Mail Address: neil�hvacdesigns.com Company Website: http:llwww.hvacdesigns.coml Desi n Data Reference City: Zephyrhill ,Florida Building Orientation: Front Door faces North Daily Temperature Range: Medium Latitude: 28 Degrees Elevatlon: 19 ft. Altitude Factor: 0.999 Outdoor Outdoor Outdoor Indoor Indoor Grains Drv Bulb Wet Bulb Rel. um Rel.Hum Drv Bulb Difference �nter: 40 37.52 nla nla 72 nla Summer: 93 77 49% 55% 75 43 Check Fi ures Total Building Supply CFM: 600 CFM Per Square ff.: 0.531 Square ff,of Room Area: 1,129 Square tt Per Ton: 1,021 Volume(it')of Cond.Space: 9,034 Build(n Losds Tot�l Heating Required Including VenUlation Air: 13,552 Btuh 13.552 MBH Total Sensible Gain: 9,950 Btuh 76 •/. Total Latent Gain: 3,190 Btuh 24 °/. Total Cooling Required Including Ventilation Air: 13,140 Btuh 1.11 Tons(Based On 75°h Sensible Capacity) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculatlons are performed per ACCA Manual J Sth Edition,Version 2,and ACCA Manual D. All omputed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. Monday,November 04,2013,12:09 PM Rhvac•Res(dential&Light Commercial HVAC Loads Elite Software Development,Inc. HVAC Designs � Walnut Grove TH 1129 N Tam a,FL 33615 Pa e 2 Manual D Ductsize Data-Duct S stem 1 -Su I -�uct Name,etc. Type Roughness Diameter Velaity SPL.Duct Upstream Temperature Width LossH00 SPL.Fit Shape Length Height FitEq.Len SPL.Tot Sizin CFM Area SP.Avail SPL.Cumul -Duct Name:SMT•100,Feeds Into:Foyer,Fitting:l•A,Effective Length:23.9 Trunk 0.003 12.4 664 0.005 Up:Fan 57 10 0.085 0.015 Rect 6.0 13 17.9 0.180 Schedule 599 23 0.090 0.230 -Duct Name:ST-110,Feeds Into:Kitchen,Fittings:ll-B,11-B,11-A,Effective Length:36.5 Trunk 0.01 10 510 0.004 Up:SMT-100 57 7.8 0.083 0.026 Rnd 4.8 10.9 31.7 0.030 Schedule 278 12.6 0.060 0.260 _.. . _. ___.._ . __........ _ _..._ __.... ._ _.._... _...._ ._. _.._._. __.__.. -Duct Name:ST•120,Feeds Into:Great,Fittings:11-B,11-8,11-A,Effective Length:48.4 Trunk 0.01 10 589 0.021 Up:SMT•100 57 7.8 0.110 0.032 Rnd 19.2 10.9 29.2 0.053 Schedule 321 50.3 0.037 0.283 _... _ _..__ ___ __..... _...... _ _ __._. _ _... -Duct Name:SR•100,Suppiies:Kitchen,Fittings:ll-B,11-B,4AA,11•B,Effective Length:20.9 Runout 0.01 6 672 0.024 Up:ST-110 57 4.7 0.287 0.036 Rnd 8.3 6.6 12.5 0.060 Schedule 132 13.1 0.000 0.320 -�uct Name:SR•110,Supplies:Bath 2,Fittings:ll-B,11-B,11-B,11-B,4AA,11•B,Effective Length:14.2 Runout 0.01 4 126 0.001 Up:ST•110 57 3.1 0.019 0.002 Rnd 6.2 4.4 8.0 0.003 Schedule 11 6.5 0.057 0.263 -Duct Name:SR-120,Supplies:Foyer,Fittings:ll-6,11-B,11-B,4AA,11•B,Effective Length:12.7 Runout 0.01 4 642 0.022 Up:ST-110 57 3.1 0.461 0.037 Rnd 4.7 4.4 8.0 0.058 Schedule 56 4.9 0.001 0.318 -�uct Name:SR•130,Supplies:Bed 2,Flttings:ll-B,11-B,4AA,11-B,Effective Length:16.3 Runout 0.01 5 579 0.022 Up:ST-110 57 3.9 0.275 0.023 Rnd 7.8 5.5 8.5 0.045 Schedule 79 10.2 0.015 0.305 _ _ -�uct Name:SR-140,Supplies:Great,Fittings:ll-B,11•B,11-B,4AA,11-B,Effective Length:15.1 Runout 0.01 6 499 0.006 Up:ST-120 57 4.7 0.159 0.018 Rnd 4.1 6.6 11.0 0.024 Schedule 98 6.4 0.013 0.307 -�uct Name:SR•150,Supplies:Great,Fittings:ll•8,11•B,4AA,Effective Length:19.5 Runout 0.01 6 499 0.017 Up:ST•120 57 4.7 0.159 0.014 Rnd 10.8 6.6 S.7 0.031 Schedule 98 17 0.006 0.314 Monday,November 04,2013,12:09 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,lnc. HVAC Designs Wa/nut Grove TH f 129 N Ta a,FL 33615 Pa e 3 Manual D Ductsize Data-Duct S stem 1 -Su I conYd —Duct Name,etc. Type Roughness Diameter Velocity SPL.Duct Upstream Temperature Width LossN00 SPL.Fit Shape Length Height FitEq.len SPL.Tot Sizin CFM Area SP.Avail SPL.Cumul ••�uct Name:SR•160,Supplies:M Bed,Fittings:11-B,11-B,4AA,Effective Length:17.8 , Runout 0.01 6 504 0.016 Up:ST•120 57 4.7 0.162 0.013 Rnd 9.9 6.6 S.0 0.029 Schedule 99 15.5 0.008 0.312 —�uct Name:SR-170,Supplies:Bath 1,Fittings:11-B,11-B,4AA,11-B,Effective Length:11.6 Runout 0.01 4 241 0.004 Up:ST-120 57 3.1 0.067 0.004 Rnd 5.3 4.4 6.3 0.008 Schedule 21 5.6 0.029 0.291 _. . __. __.. _........ _..._... _..._ . _..__ __ ___._ _.....__. _....... __ —�uct Name:SR-180,Supplies:M Wic,Fittings:ll-B,11•B,4AA,11-B,Effective Length:12.4 Runout 0.01 4 57 0.000 Up:ST•120 57 3.1 0.004 D.000 Rnd 7.0 4.4 5.4 0.001 Schedule 5 7.3 0.036 0.283 Report Uniffi:Pressure:in.wg,Duct lengths:feet,Duct sizes:inch,Airflow:CFM,Velocity:ft.lmin,Temperature:F Notes: Static pressure available values for return ducts are at the entrance of the duct. For supply,they are at the exit The cumulative static pressure loss value for a return trunk is with respect to the entry point of the return runout upstream with the highest static pressure available. Total and cumulative static pressure loss values for the supply main trunk include any device pressure losses entered,and the cumulative may also include the total static pressure loss of the return side. Summa Number of active trunks: 3 Number of active runouts: 9 Total runout outlet airtlow: 599 Main trunk ai�flow: 599 Largest trunk diameter: 12.4 SMT-100 Largest runout diameter: 6 SR-100 Small•sttrunkdiameter: 10 ST•110 Small•strunoutdiameter: 4 SR-110 Supply fan external static pressure: 0.320 Supply fan device pressure losses: 0.160 Supply fan static pressure available: 0.160 Runout manimum cumulative static pressure loss: 0.320 SR-100 Return loss added to supply: 0.050 Total effective length of return(ft.): 60.2 RR-100 Total effective length of supply(ft.): 81.3 SR-100 Overall total effective length(R): 141.5 RR-100 to SR-100 Design overall friction rate per 100 it: 0.173 (Available SP x 1001 TEL) System duct surface area(Scenario 1): 149.3 Hot Vented Attic (Linked to duct load) System duct surface area(Scenario 4): 23 Exposed in Space (Linked to duct load) Total system duct surface area: 172.3 Monday,November 04,2013,12:09 PM Rhvac-Residential 8 Light Commercial HVAC Loads Elite Software Development,lnc. HVAC Designs � WaMut Grove TH 1129 N Tam a,FL 33615 Pa e 4 Manual D Ductsize Data-Duct S stem 1 •Return —Duct Name,etc. Type Roughness Diameter Velaity SPL.Duct Upstream Temperature Width Loss1100 SPL.Fit Shape Length Height FitEq.Len SPL.Tot Sizin CFM Area SP.Avail SPL.Cumul --�uct Name:RMT•100,Feeds From:Foyer,Fitting:5-B,Effective Length:38.0 Trunk 0.003 12.4 665 0.002 Up:Fan 75 10 0.082 0.029 Rect 3.0 13 35.0 0.031 Schedule 600 11.5 -0.018 0.050 —Duct Name:RR-100,Returns From:Foyer,Fitting:2-D,Effective Length:22.2 Runout 0.003 12.4 665 0.001 Up:RMT•100 75 10 0.082 0.017 Rect 1.0 13 21.2 0.018 Schedule 600 3.8 0.000 0.018 _ . __._.. __ _ _._ ..... _.. _.__. .___._._ _._..._ _ .._ _.__ ........ Report Units:Pressure:in.wg,Duct lengths:feet,Duct sizes:inch,Airflow:CFM,Velocity:ft.lmin,Temperature:F Notes: Static pressure available values for return ducts are at the entrance of the duct For supply,they are at the exit The cumulative static pressure loss value for a return trunk is with respect to the entry point of the return runout upstream with the highest static pressure available. Total and cumulative static pressure loss values for the supply main trunk include any device pressure losses entered,and the cumulative may also include the total static pressure loss of the return side. Summa Number of active trunks: 1 Number of active runouts: 1 Total runout ouUet airflow: 600 Main trunk airflow: 600 Largest trunk diameter: 12.4 RMT•100 Largest runout diameter: 12.4 RR-100 Small•stVunkdiameter: 12.4 RMT-100 Small•strunoutdiameter: 12.4 RR-100 Runout maximum cumulative static pcessure loss: 0.018 RR•100 Return loss added to supply: 0.050 Total effective length of return(R): 60.2 RR•100 System duct surface area(Scenario 4): 15.3 Exposed in Space (Linked to duct load) Total system duct ourface area: 15.3 Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition,Version 2,and ACCA Manual D. All omputed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. Monday,November 04,2013,12:09 PM Rhvac-Residential&Light Commercial HVAC Loads � Elite Sottware Development,Inc. HVAC Designs Wa/nut Grove TH 1129 N Tam a,FL 33615 Pa e 5 Manual D Ductsize•Pressure Chan es Gra h-S stem 1 Pressure Changes Through Route with Highest Static Pressure Loss o.�s 0.14 ��..--�... �...� 0.12 �p �`—l►-�. ` �'� i � \ 0.10 �� � � '' \ �i / 0.08 i ' `�� , , ; � �� �.�� c 0.06 ;� %I � i \ ; \ » 0.04 � i"� � •`� � �� � ', a 0.02 � ,__--..�,_�._ �� j � � !, 0.00 �- _ _ ; ,; _ ;" i -0.O2 '�.j� .� _ i; -0.04 - -0.O6 �� __..._:-_._ Static Pressure Available Total Pressure Available __.. ............ __ _.. _....... _....... Notes: Return side point values are at enwance of duct,while supply side polnts are at exit When a return system is present,an additional return side point named[Fan Entrance]is drawn in the graph to show the static pressure available at the entrance of the fan. When a supply system is present,and an additional suppty side point n,med[Fan Exit]is drawn to show the static pressure available at the exit of the hn. Any device pressure losses entered for the supply main trunk are accounted for between the fan entry and exit points. Point Name Static Pressure Available Total Precsure Available A RR-100 0.000 0.027 B RMT•100 -0.018 0.009 C [Fan Entrance] -0.050 -0.022 D [Fan Exit] 0.110 0.138 E SMT-100 0.090 0.118 F ST-110 0.060 0.076 G SR-100 0.000 0.029 Monday,November 04,2013,12:09 PM Rhvac-Residentlal&Light Commerclal HVAC Loads Elite Sottware Development,inc. HVAC Designs WalnutGrove TH 1129 N Tam a,FL 33615 Pa e 6 Total Buildin Summa Loads Component Area Sen Lat Sen Total Deccri tion Quan Loss Gain Gain Gain OP LOW E MIN:Gluing•NFRC CODE MIN Operable 2 45.2 723 0 565 565 Pane Low E,ground reflectance=0.23,outdoor insect screen with 50%coverage,light color blinds at 45°with 100°/.coverage,u-value 0.5,SHGC 0.5 FD LOW E MIN:Glazing-NFRC CODE MIN Glass Door 2 20 320 0 278 278 Pane low E,ground reflectance=0.23,light color bUnds at 45°with 100°/.coverage,u-value 0.5, SHGC 0.5 11 N:Door-Metal-Polystyrene Core 40 434 0 343 343 12B-0sw:Part-Frame,R-11 insulation in 2 x 4 stud 194.6 567 0 377 377 cavity,no board insulation,siding finish,wood studs 13A-4ocs:Wall-=1ock,board insulatlon only,R-4 board 296.2 1,356 0 775 775 insulation,open core,siding fnish 13A-4ocs:Part•Block,board insulation only,R-4 board 92 395 0 263 263 insulation,open core,siding finish 168-30-ad:RooflCeiling-Under Attic with Insulation on 1129.3 1,157 0 1,915 1,915 Attic Fioor(also use for Knee Wall and Partition Ceilings),vented attic,no radiant barrier,R-30 insulation,dark asphalt 22A-pm:Floor-Slab on grade,No edge insulation,no 86 3,247 0 0 0 insulation below floor,any floor cover,passive, heavy dry or light wet soil ---- -_ __ ---- _- -- ---- ------ -- -- --- -- Subtotals for structure: 8,199 0 4,516 4,516 People: 3 690 900 1,590 Equipment: 640 2,040 2,680 Lightfng: 0 0 0 Ductwork: 1,646 272 1,422 1,694 InNltration:Wlnter CFM:105,Summer CFM:54 3,707 1,588 1,072 2,660 VentilaGon:Wmter CFM 0 Summer CFM 0 0. _0 0 0 _. _........_ �......... __..._. __ _ _ _. __ _ Total Building Load Totalc: 13,552 3,190 9,950 13,140 Check Fi ures Total Building Supply CFM: 600 CFM Per Square ft.: 0.531 Square ft.of Room Area: 1,129 Square ft.Per Ton: 1,021 Volume(ft')of Cond.Space: 9,034 Buildin Loads Total Heating Required Inciuding Ventflation Air: 13,552 Btuh 13.552 MBH Total Sensible Galn: 9,950 Btuh 76 % Total Latent Gain: 3,190 Btuh 24 % Total Cooling Required Including Ventilation Air: 13,140 Btuh 1.11 Tons(Based On 75%Sensible Capacity) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition,Version 2,and ACCA Manual D. All omputed results are estimates as building use and weather may vary. Be sure to select a unit that meets both senslble and latent loads according to the manufacturer's performance data at your design conditions. Monday,November 04,2013,12:09 PM Rhvac-Res(dential&Light Commerctal HVAC Loads Elite Software Development,lnc. HVAC Designs Wa/nut Grove TH 1129 N Ta a,FL 33615 Pa e 7 S stem 1 Room Load Summa Htg Min Run Run Clg Clg Min Act Room Area Sens Htg Duct Duct Sens Lat Clg Sys No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM –Zone 1— Foyer 50 2,381 54 4 • 930 133 47 56 3 Bed 2 156 3,112 71 5 - 1,317 339 67 79 4 Bath 2 54 64 1 4 - 177 60 9 11 5 Kitchen 204 802 18 6 - 2,188 500 111 132 6 Bath 1 127 146 3 4 • 345 80 17 21 7 Great 276 3,022 69 6,6 • 3,259 1,129 165 197 8 M Wic 45 52 1 4 • 89 0 4 5 _ 9.. M Bed _._ _ 217 3,970_ 90 __ 6 • _ 1645 _ 677 83 99 .... .._. .._..._. _....... _. .1......_...._.. . ......_... .__... ____.......___ _...._.....Duct_latent ..... _...__ _ _ __.__ . ......__ _272 _._ _.___... _....._ _...__. __._.. __ System 1 total_. 1,129 13,552... 308 ....._ _ ____9,950 3190 503 600 _ _ __. . _.... . �.. _...._.. _ _..._.... System 1 Main Trunk Size: 10x13 in. Velocity: 664 ft.lmin Loss per 100 ft.: 0.085 in.wg Duct size results above are ftom Manual D Ductsize. Runout dud velocities are not printed with duct size results from Manual D Ductsize since they can vary within the room. See the Manual D Ductsize report for duct velocities and other data. Cooling System Summary Cooling SensiblelLatent Sensibie Latent Total Tons S lit Btuh Btuh Btuh Recommended �,�� 75%125% 9,950 3,317 13,267 Actual: 1.55 75°/.125% 13,950 4,650 18,600 E ui ment Data Heatina Svstem Cooling Svstem Type: Air Source Heat Pump Air Source Heat Pump Model: 4A6H3018C1 4A6H3018C1 Indoor Model: GAF2AOA18S11+TDR Brand: HERITAGE 13 HERITAGE 13 Description: Air Source Heat Pump Air Source Heat Pump Efficlency: 8.2 HSPF 14 SEER Comment: 0 Sound: 0 0 Capacity: 17,600 Btuh 18,600 Btuh Sensible Capacity: nla 13,950 Btuh Latent Capacity: nla 4,650 Btuh AHRI Reference No.: nla 4941299 This system's equipment was selected in accordance with ACCA Manual S. Manual S equipment sizing data: SODB:93F,SOWB:T7F,WODB:40F,SIDB:75F,SIRH:55%,WID6:72F,Sen.gain:9,950 B�h,Lat gain:3,190 Btuh, Sen.loss:13,552 Btuh,Entering clg.coil DB:75F,Entering clg.coil WB:63.9F,Entering htg.coil DB:72F,Clg.coil TD:18F,Htg.coil TD:40F,Req. clg.airflow:503 CFM,Req.htg.airflow:308 CFM Monday,November 04,2013,12:09 PM