HomeMy WebLinkAbout13-14841 CITY OF ZEPHYRHILLS
5335—8TH STREET
(sis)�so-oo20 14841
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
���: � ^�asq�w � „�_;u ���� � _�:�. ��1'�, �.� .�"�� ��,. � �°�,��
Permit#:14841/14839 Issued: 12/20/2013 Address: 37843 PRAIRE ROSE LP LT 27
Permit Type: GENERAL BUILDING PERMIT ZEPHYRHILLS, FL.
Class of Work: 105-NEW CONST/MULTI 5+ UNIT Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: Total Fees: 8,386.37 Subdivision: WALNUT GROVE TOWNHOMES
Amount Paid: 8,386.37 Date Paid: 12/20/2013 Parcel Number: 15-26-21-0030-06600-0000
� �c �" :.�`
a. ��.
Name: BAILEY CONTRACTING LLC Name: BUTTERFIELD MOBILE HOME
Addr: 4209 GALL BLVD Address: 4034 GALL BLVD
ZEPHYRHILLS, FL 33542 ZEPHYRHILLS
Phone: (813)377-7395 Lic: Phone: (813)973-5250
Work Desc: NEW CONSTRUCT 4 UNIT TOWNHOME (#3 UNIT)
�a,���� ���� �����.�� � �' ��:� k �: � �� �k� ' :;.•� �. .��„ �. �,.
y� �p ,,
9".i` ^=�to:n l�r z. B �N� f .. }��" y�y � e^ �iS ,r� Y !w,�'.'�
� 330.69 L L 9. 4 UM I 4 . 3
MECHANICAL FEE 32.50 SEWER CONNECTION RESIDEN" 2,010.00 WATER CONNECTION RESIDENI 641.00
WATER METER RES 3/4" 348.09 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00
PUBLIC SAFETY 5% 26.35 PARK FEES TOWNHOMES 769.56 SCHOOL IMPACT FEE—sfr/100% 0.00
SCHOOL IMPACT FEE—sfr/1% 0.00 TRAFFIC IMPACT FEE 99% 3,445.20 TRAFFIC IMPACT FEE 1% 34.80
FIRE PLAN REVIEW FEES 105.11
; ��� '�- )
�� �
(��ci���''y` ���.�
;,�r�d �,_� s�,� �`,���� � �� ,
w�2 '�t �,�ti'a' �.,1'�,+� ��" ��#�tl�?;ESti ,� . ;��.� s��a„ �" "�SC;� `"".�.�a�':�� .�z�
R U LU» IN I LI
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE—METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE—SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80(2)(c)when extra inspection
trips are necessary due to any one of the following reasons: a)wrong address b)condemned work resulting
from faulty construction c) repairs or corrections not made when inspections called d) work not ready for
inspection when called e) permit not posted on job site� plans not at job site g) work not accessible.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans, Specifications and Must Accompany Application.All work shall be performed in accordance
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
l ) G•- �JO'
FY � j
CO TRA TORS� IGNATURE PERMIT OFFI
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
CITY OF ZEPHYRHILLS
5335-8TH STREET
(sis)�so-oo20 14841
BUI�DING PERMIT SINGLE FAMILY RESIDENTIAL
Permit#:14841 Issued: 12/20/2013 Address: 440 URT ST
Permit Type: GENERAL BUILDING PERMIT ZEPHY S, FL.
Class of Work: 105-NEW CONST/MULTI 5+ UNIT Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: Total Fees: 8,386.37 Subdivision: CITY OF ZEPHYRHILLS
Amount Paid: 8,386.37 Date Paid: 12/20/2013 Parcel Number: 15-26-21-0030-06600-0000
Name: BAILEY CONTRACTING LLC Name: BUTTERFIELD MOBILE HOME
Addr: 4209 GALL BLVD Address: 4034 GALL BLVD
ZEPHYRHILLS, FL 33542 ZEPHYRHILLS
Phone: (813)377-7395 Lic: Phone: 813-973-5250
Work Desc: NEW CONSTRUCT 4 UNIT TOWNHOME (#3 UNIT)
MECHANICAL FEE 32.50 SEWER CONNECTION RESIDEN" 2,010.00 WATER CONNECTION RESIDENI 641.00
WATER METER RES 3/4" 348.09 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00
PUBLIC SAFETY 5% 26.35 PARK FEES TOWNHOMES 769.56 SCHOOL IMPACT FEE-sft/100% 0.00
SCHOOL IMPACT FEE-sfr/1% 0.00 TRAFFIC IMPACT FEE 99% 3,445.20 TRAFFIC IMPACT FEE 1% 34.80
FIRE PLAN REVIEW FEES 105.11
L
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80 (2)(c)when extra inspection
trips are necessary due to any one of the following reasons: a)wrong address b)condemned work resulting
from faulty construction c) repairs or corrections not made when inspections called d)work not ready for
inspection when called e) permit not posted on job site f) plans not at job site g)work not accessible.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications and Must Accompany Application. All work shall be performed in accordance
with Ci Codes and Ordinances. NO OCCUPANCY BEFORE C.O. '
�
NTRA TO SIGNATURE PERMIT OFFI
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
4408 COURT ST- BAILEY CONTRACTING LLC 4UNIT TOWNHOME
� units-2-4
SQ. FEET PRICE
MAIN OR LIVING:
OTHER AREA UNDER ROOF: -
OTHER: - $ _
VALUATION
FEE SHEET
ADDRESS
DRIVEWAY
BUILDING: $ 330.69
ELECTRICAL: $ 69.64
PLUMBING: $ 46.43
MECHANICAL: $ 32.50
SUB-TOTAL $ 479.26
TOTAL $ 479.26
SEWER: $ 2,010.00
WATER: $ 641.00
IRRIGATION: $ -
TOTAL: a 2,651.00
WATER METER: $ 348.09
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: $ 105.11
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: ; 105.11
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: S 553.35
S U B-TOTAL $ 4,136.81
PARK IMPACT FEES 5 769.56
SIF'S: $ 1,757.40
100.0% $ 1,740.00
1.0% $ 17.40
TOTAL: E 1,757.40
T I F'S: a 3,480.00
99% $ 3,445.20
1% $ 34.80
TOTAL: $ 10,143.77
�
a�
�
0
�
�
�
0
E�
a�
�
0
�,
C7 �
� �
�
� �
� � �
o ..
N Z F
� 0
� � Q
Q Z � � Q
~ Q � z
O O � � �,
►�-� w ¢ �
� � Q
� a
� w O
� � � � , �.
� H � �
�..� C!� p o �
0
a x W N �
N o�p � a o °' ;
� � ¢
/s, tn U a ° �
O � � � ° � w
�-' 1� � � � °o Eo CO,7
�' W � '�. N � z
U U '� a o z A
�
� � ui z �
� � � �q
U c�+� � Q f- �
� w
a.> Ll � �r .. �
� P�
� W a � � � f�
W 0 � p" p�q
d Q d � W W '-�
z ¢ a H a x r�
FORM 405-10
FLORIDA ENERGY EFFlCIENCY CODE FOR BUILDING CONSTRUCTIQN
Florida Deparfinent of Business and Professiona!Regu/ation= Residentia!Performance Method
Projecf Name: Walnut Grov�TH 1505 N Bu/iderName: �-j�,�F1 ���'�-���L�1`
Shsat• 4408CouriStreet PermltOAlce: Iephyrhids f
C/ty,Sfate,Zip: Zephyrhills,FL,33542- Pemr#Alumber: I `k�`�t ��I
Owner. Jurisdiction: 611800
Desiyntocaflon: FL,Tampa ,
?. New consbucGon orexfshng New(From Plans) : 9. Wa1lTypes(1109.4 sqR.) Insulafion ,qrea
2.SinylefamityormulHple/amity Multi-family a.Conc�ste8lock-fntlnsal,Extenor R�4,0 91T.08ft'
3. Numberofunits,i/mulllple family � b.Fiame-Wood,Ad/acent R=11.0 197.36 fN
c.WA R= �
4. NumberofBedrooms 3 d.N/A �
5. !s fhia a worstcase? �yo 10.CeifingTypes (?505.0 sqlt) lnsuleUon Area�
a.f/nderAtlic(Ventsd) R=30.0 1505.00fN
6. CondiNonsd Aooraroa abovo grede(f�) 1 bps b.N/A � n,
Condltionedlkoraroabelowgrade(1!=) 0 c.N/A R= iN
7. Wlndows(f53.i sqft) pescrlpbon �a 11,Ducts . R �,
a.Sup:Ateic,Ret.'HVAC 1,AH:HVAC 1 6 244
e. U-Fector, Dbl,U=0.50 153.08 ft' . .
SNGC: SHGC0.50
b. iN�ircfw: A!/A hr 12.Cooling systems k8tr�hr Eli'icrency
SHGC: a.Central Unit 25.0 SEER:13.75
c. I�Factor. N/q � �
SHGC: i3.HeaBngsystema kBtu?rr Efflciency
d. U-Facfor. N/A k' a.ElecWc HeatPump� 23.6 HSPR8.20
SHGC:
A+eaWalyhtedAverayeO�rorhengDepth: 2,71�
Arsa Welghted Average SHGC: p,500 f a.Hot water aysMms
8. FloorTypes (1505.0 sqfL) lnsuiafion Arsa a.Elechic Cap:40galJons
a.Slab-On-Giade Edpe Msulallon R=0.0 1505.00 lt= EF.•0.920 '
b.N/A b• Cor►seNafion teatures
� � None
c.N/A � �
15.Credits Patat
Glass✓F/oorArea: 0.102 Total Prr�posed Moal'�ed Loads: 32.06 �A��
Tote/Standani Refer+�nce Loads: 40.88 �'1
t hereby certify that the p/an and s ea6cations covered by Review of the plans and ��iB Sr,��,
thls calculation are in com ance li the Florida Energy specil'icetions covered tiy this - � ��
�B' • celculationindicatescomp!lance r � 'p
" with the Florida Fnergy Code. 1� '�j
PREPAR D/3 Betors constrvction is completed � - �
DATE.• �^"T� � this building will be inspected Ibr � � -
� � - a
compliance wrth 5ection 553.908 * t
!hereby certify that this building,�es designed,is in compliance Flortda Sfatutes. ,
with the Florida Energry Code. �'�,+OD���
OWNER/AGENT: BUILDlNG OFF/C/AL:
DATE: DATE:
- Compllance requires certification by.the�lr handler unit manufacturer that the air handler encfosure qualifles as
certi8ed hctoryaealed in accordanca with 403.2.2.1„7. �
- Compliance requires completlon of a Florlda Air Barrier and tnsulation InspecUon Checklist '
11/42013 10:50 AM EnapyGauge�USA-FlaRes2010 Section 405.4.1 Compliartt SoRwsre Pays 1 of 6
PROJECT
T'tt/e: Wa/nut Grove TH 1505 N Bedrooms: 3 Address Type: Street Address
Building Type: User Conddioned Area: 1505 Lot�
Owner: Total Stories: 1 B/ocWSubDivision:
#ol Unds: 1 Worst Case: No P/atBook:
Builder Name: Rotate Ang/e: 0 Street: 4408 Court Street
Permit Of/'�ce: Zephyrhills Cross Ventilation: County: Pasco
Jurisdiction: 6f 1600 Who/e House Fan: Cdy,State,Zin: Zephyrhills,
Family Type: Mu/ti-family FL, 33542-
New/Existing: New(From P/ansJ
Comment:
CLIMATE
, / IECC Design Temp !nt Design Temp Neating Design Daily Temp
V Desgn Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL, Tampa FL TAMPA_INTERNATIO 2 39 91 72 75 645.5 54 Medium
BLOCKS
Number Name Area Volume
1 B/ockl 1505 12040
SPACES
Number Name Area Volume Kdchen Occupants Bedrooms Infi/ID Finished Coo/ed Heated
1 HVAC 1 1505 12040 Yes 4 3 1 Yes Yes Yes
FLOORS
# F/oor Type Space Perimeter R-Value Area Tile Wood Carpet
1 Slab-On-Grade Edge Insulata HVAC 1 139 fr 0 1505 ftz ____ 0.4 0.4 0.2
ROOF
, / Rool Gab/e Roof So/ar SA Emitt Emitt Deck Pitch
V � Type Materials Area Area Cobr Absor. Tested Tested Insul. (deg)
1 H�p Composdan shingles 158611z 0/tz Daik 0.96 No 0.9 No 0 18.4
ATTIC
v # Type Ventilatan Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 1505/t2 N lV
CEILING
# Ceiling Type Space R-Value Area Framing Frac Truss Type
1 Under Attic(Vented) HVAC 1 30 1505/tz p,�� �,y�
11/4/2013 f0:50 AM EnergyGauge�USA-F1aRes2010 Section 405.4.1 Compliant Software Page 2 of 6
WALLS
Adjacent Space Cavdy Width Height Sheathing Framing Sofar Be/ow
- o
_ 1 W Garage Frame-Wood HVAC 1 11 3.33 0 8 0 26.61t2 0 0.23 0.01 0
_ 2 N Garage Frame-Wood HVAC 1 11 3.17 0 8 0 25.4 k2 0 0.23 0.01 0
_ 3 W Garage Frame-Wood HVAC 1 11 8.5 0 8 0 68.0 ftz 0 0.23 0.01 0
_ 4 N Exterar Concrete Bbck-Int lnsu/ NVAC 1 4 5 D 8 0 40.0 ft2 0 0 0.35 0
_ 5 N Exterior Concrete Bbck-lnt lnsu/ HVAC 1 4 13 0 8 0 104.0/tz 0 0 0.35 0
_ 6 E Exterror Concrete B/ock-Int Insu/ HVAC 1 4 14.5 0 8 0 116.01tz 0 0 0.35 0
_ 7 N Garage Frame-Wood HVAC 1 11 9.67 0 8 0 77.4 It? 0 0.23 D.Of 0
_ 8 E Exterar Concrete 8bck-Int/nsul HVAC 1 4 13.83 0 8 0 1>0.6 ffz �7 0 0.35 0
_ 9 S Exterior Concrete Block-!nt/nsul HVAC 1 4 15.17 D 8 0 121.4 Rz �7 0 0.35 0
_10 E Exterior Concrete 8lock-lnt lnsu/ HVAC 1 4 20.17 0 B 0 161.41t2 i7 0 0.35 0
_ 11 S Exterior Concrete Bbck-Int/nsul HVAC 1 4 15.67 0 8 0 125.4 ft2 0 0 0.35 0
_ 12 W Exterior Concrete B/ock-Int Insu/ HVAC 1 4 8.17 0 8 0 65.4 ftz D 0 0.35 0
_ 13 E Exterior Concrete Block-Int lnsul HVAC 1 4 8.5 0 8 0 68.0 ff2 0 0 0.35 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft !n Ft In
1 W Insulated HVAC 1 None 0.35 3 0 6.67 0 20.01000
2 N Insulated HVAC 1 None 0.35 3 L� 6.67 0 20.01000
WINDOWS
Orientation shown is the entered,Proposed orientatbn.
✓ wa� Overhang
# Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 N 5 TIM Low-E Doub/e Yes 0.5 0.5 23.2 ftz 1 R 0 in 1 ft 0 in Drapes/blinds Exterar 5
2 E 6 TIM Low-E Double Yes 0.5 0.5 16.2 RZ 1 ft 0 in 1 it 0 in Drapes/blinds Exterbr 5
3 E 8 TIM Low-E Doub/e Yes 0.5 0.5 16.2 Rz 1 ft 0 in 1 ff 0 in Drapes/blinds Exterbr 5
4 S 9 T!M Low-E Double Yes 0.5 0.5 12.81t2 9 ft 0 in 0 ft 0 in Orapes/blinds Exterbr 5
5 S 9 TIM Low-E Doub/e Yes 0.5 0.5 20.01t2 91t 0 in 0 R 0 in Drapes/blinds Exterar 5
6 E 10 TIM Low-E Double Yes 0.5 0.5 16.2 It2 1 R 0 in 1 R 0 in Drapes/blinds Exterar 5
7 E 10 T!M Low-E Doub/e Yes 0.5 0.5 16.2 RZ 1 fr 0 in 1 ft 0 in Drapes/blinds Exterior 5
8 S 11 TIM Low-E Doub/e Yes 0.5 0.5 16.21t2 1 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5
9 S i f TIM Low-E Doub/e Yes 0.5 0.5 16.2 ft? 1 R 0 in 1 R 0 in Drapes/blinds Exterar 5
GARAGE
�Y Floor Area CeiGng Area Exposed Wal/Perimeter Avg. Wad Height Exposed Wal!Insu/ation
1 238 R� 238 flT qg n g� p
11/4/2013 10:50 AM EnergyGauge�USA-FlaRes2010 Sectan 405.4.1 Compliant Sollware Page 3 0l6
INFILTRATION
�Y Scope Method SLA CFM 50 ELA EqLA ACN ACH 50
1 Who/ehouse Best Guess 0.000300 11B4.29 65.0160 122.272 0.22500 5.90178
HEATING SYSTEM
� System Type Subtype Eff'�ciency Capacity Block Ducts
(fnvaliE/ectric Heat Pump None HSPF:8.2 23.6 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subrype EH'�ciency Capaciry Air Fbw SHR B/ock Ducts
(�nvaliCentra/Unit None SEER:13.75 25 k8tu/hr 750 c/m 0.75 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservatbn
1 E/ectrrc None Garage 0.92 40 ga! 60 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
CeR # Company Name System Model# Collector Model# Area Vo/ume FEF
None None ftz
DUCTS
/ ----SuPP�Y---- ----Retum---- Air CFM25 HVAC#
V � Locatan R-Value Area Locatbn Area Leakage Type Hand/er CIF�P5 OUT QN RLF Heat Cool
(�nvali Attic 6 244 RY HVAC 1 18 It� Default Leakage HVAC 1 (invatid)cf(Defau/t)c 1 1
TEMPERATURES
Programable Thermostat: Y Ceiling Fans:
Cooling )Jan Feb ]Mar A r Ma g fX Se I ]Oct )Nov )Dec
Heating f Xj Jan �J�Feb f Xj Mar �(�]A�r �(i M y [�jun (�J% lX}Aug /�Sep j]Oct f Xj Nov �X]Dec
Venting (]Jan ]Feb jx]Mar jX]A r j]Ma
I Jun l Jul I 7 Au j Se �x]Oct jx]Nov ]Dec
11/4/2013 10:50 AM EnergyGauge�USA-F/aRes2010 Sectan 405.4.1 Compliant Soltware Page 4 of 6
Thermostat Schedu/e: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 7B BO 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
11/4/2013 10:50 AM EnergyGauge�USA-F/aRes20f0 Secfion 405.4.1 Compliant Software Page 5 of 6
FORM 405-10
Florida Code Compliance Checklist -
Florida Department of Business and Professiona!Regulations
Residenfial Whole Building Performance Method
ADDRESS: 4408 Court Street PERMIT#:
Zephyrhills,FL,33542-
MANDATORY REQUIREMENTS SUMMAI�Y-See individual code sections fo�full detaiis.
CpMPONENT SECTION SUMMARY dF REQUlREMENT(S) CHECK
Airleakage 402.4 To be caulked,gasketed, weathersfripped or otherwrse sealed.
Recessed lighting/C-rated as meefing ASTM E 283. �ndows and �
doors=0.30 cfm/sq.ft. Testing or visua!inspection requirt�d.
Finep/aces:gasketed doors&outdoor combustion air. Must complete
enve/ope/eakage report or visuaqy verify Tab/e 402.4.2.
Thermostat& 403.1 At least one fhermostat shal!be provided for each separate heating
controls and cooling system. Where fo�ed-air fumace is primary system,
programmab/e therrnostat is r+equireal.Heaf.pumps with suppJeri�enta/ d
e/ectric heat must pr+avent supp/ementa/heat when compressorcan
meet the load.
Ducfs 403.2.2 All ducts,air handJers, frlter boxes and building cavities which form the �
primary air containmenf passageways for air qlistribution systems sha11
be considered ducts or p/enum chambers,shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code. �
403.3.3 Building framing cavities shal!nof be used as supp/y ducts.
Wster heaters 403.4 Heat trap required for vertical pipe rrse►s. Comp/y w/th elficiencies in
Table 403.4.3.2. Provide switch or c/esriy marked ci�uit bresker �/
(electric)orshutoff(gas). Circulating system p/pes insu/ated fo=
R-2+accessible manua/OFF switch. � ,
Mechanical 403.5 Homes designed to operate at positive pressure or with mechanica!
ventllaSon ventrlat�on systems shal!not exceed the minimum ASHRAE 62/eveL �
. No make-up a1r from attics, craw/spaces, gareges or outdoors adjacent ,�
, to pools or spas. _
-�. .-)F�
SwimmingPools 403.9 'Poo/pumps and pool pump motors with a tota/horsepower(HP)of= 1
&Spas ; . .. HP'shail have the capability of operating at two or morts speeds. Spas
� • � and heated poo/s must have vapor-►etardant covers or a liquid cover or� �
� � � • — other means pr�ven to rtsduce heat foss ext�ept if 7096 of heat from
� .. , site-recovered energy. Offit►mer swifch required. Gas heaters minimam -
them►a/e�ciency=78%(82%aRer 4/16/13). Heat pump poo/hesters , �A -
minimum COP=4.0.
Coolinsyt►eaBng 403.6 Sizing calcu/ation performed&attached.Minimum efficiencies per
�Tables 503.2.3.Equipmenf e�ciency verlflcation nequ/red. Specral �/
equipment odrasion cooling or heating capacity nequires separate system or
varisble capacfty system. Electric heat>10kW must be divided into two
or more stages. •
CeilingsAcnsewalls 405.2.1 R-�9 space permitting.
f 1/4/2013 J0:50 AM EnerpyGaupe�USA-FfaRes2010 Sectlon 405.4.1 Complienf SofAvare PaQe 8 of 8
_ �.- _ ._„-_ _._...� .. . .'. . . .._.. `
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE /NDEX* - 78
The lower the EnergyPerformance Index, the more efficient the home.
4408 Court Street, Zephyrhills, FL, 33542-
1. New construction or existing New(From P/ans) 9. Wall Types /nsu/ation Area
2 Sing/e lamily or multip/e family Mulli-family a.Concrete Block-Int/nsul,Exterar R=4.0 91208 ft2
b.Fiame-Wood,Adjacent R=11.0 197.36 it2
3. Number of units,if multqv/e family f � N�A R_ h2
4. Number of Bedrooms 3 d.N/A R= h2
5. Is this a worst case? No 10.Cei6ng Types /nsu/atan Area
a.Under Attic(Vented) R=30.0 15o5.00 ft2
6. Conddioned f/oor area(/tzJ 1505 b.N/A R= nZ
7. Windows" Descriptbn Area �'N�A R= /t2
a. U-Factor: Dbl,U=0.50 153.08 ffz ��•Ducts R nz
SHGC: SHGC=0.50 a.Sup:Attic,Ret:HVAC 1,AH:HVAC 1 g pqq
b. U-Factor: N/A �2
SHGC: 12.Cooting systems kBtu/hr Ef/Iciency
c. U-Factor: N/A lt2 a.Central Unit 25.0 SEER:13.75
SHGC:
d. U-Factor: N/A Nz
SHGC: 13.Heating systems kBtu/hr EH'�ciency
Area Weghted Average Overhang Depth: p.���� a.E/ectric Heat Pump 23.6 HSPF.•8.20
Area Weighted Average SHGC: 0.500
8. F/oor Types Insulation Area 14•Hot water systems
a.Slab-On-Grade Edge Insu/atron R=0.0 1505.00 ft2 a.EJectric Cap:40 galbns
b.N/A q= n2 EF:0.92
c.N/A R= hz b. Conservatan features
None
15.Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed(or exceeded) .y o��S�
in this home before fina!inspection. Otherwise, a new EPL Disp/ay Card will be comp/eted �q�' � ��'
based on installed Code compliant features. F„ �
Builder Signature: Date: � --- y�
Address of New Home: City/FL Zip: * �
�QdD WB'T'�'�
*Note: This is not a Building Energy Rating. If your lndex is below 70,your home may qualify for energy efficient
mortgage(EEM)incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(32i)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's
support staff.
'"Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnergyGauge�USA-FlaRes2010 Section 405.4.1 Compliant SoHware
TABLE 4Q2.4.2
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Wa/nut Grove TH 1505 N Builder Name:
Street: 4408 Court Street Permit ON"�ce: ZephyrhiUs
Cdy,State,Zip: Zephyrhills,FL,33542- Permit Number:
Owner: Jurisdiction: 611600
Design Location: FL, Tampa
COMPONENT CRITERIA CHECK
Air barrier and thermal barrier Exterior thermal enve%pe insulation for framed walls is installed in
substantial contact and continuous alignment with building envelope
air barrier.
Breaks or joints in the air barrier are fi!led or repaired.
Air-permeable insulation is not used as a sealing material.
Air- ermeable insulation is inside of an air barrier.
Ceiling/attic Air barrier rn any dropped ceiling/soffit is substantially aligned with
insulation and any gaps are sealeal.
Attic access (except unvented attic), knee wall door, or drop down
stair is sea/ed.
Walls Corners and headers are insulated.
Junction of foundation and sill plafe is sea/ed.
Windows and doors Space between window/door jambs and framing is sea/ed.
Rim joists Rim joists are rnsulated and include an air barrier.
Floors (including Insulation is installed to maintain permanent contact with underside
above-garage and of subfloor decking.
cantilevered floors)
Crawl space walls Insulation is permanently attached to walls.
Exposed earth in unvented craw/spaces is covered with C/ass I
Shafts,penetrations Duct shafts, utility penetrations, knee walls and flue shafts opening
to exterior or unconditioned space are sea/ed.
Narrow cavities Batts in narrow cavities are cuf to fii, or narrow cavities are filled by
sprayed/blown insulation.
Garage separation Air sealrng is provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures are arr tight, lC rated, and sealed to drywall.
Exception—fixtures in conditroned space.
Plumbing and wiring Insulation rs p/aced between outside and pipes. Batt insulation is cut
to fit around wiring and plumbing, or sprayed/blown insulation
Showedtub on exterior wall Showers and tubs on exterior walls have insulation and an air
barrier se aratin them from the exterior wall.
E/ectrical/phone box on Air barrier extends behind boxes or air sealed-type boxes are
installed.
Common wall Air barrier is installed in common wall between dwellrng units.
HVAC register boots HVAC register boots that penetrate building envelope are sealed to
subfloor or d all.
Fire /ace Fire /ace walls include an air barrier.
EnergyGauge�USA-F/aRes20 f 0 Section 405.4.1 Compliant Soltware
Rhvac-Residential&Light Commercial HVAC Loads Ellte Soflware Development,Inc.
HVAC Designs Walnut Grove TH 1505 N
Tam a,FL 33615 Pa e 1
Project Report
General Project Information
Project Title: Walnut Grove TH 1505 N
Project Date: Saturday,November 02,2013
Company Name: HVAC Designs Inc
Company Representative: Neil Fimbel
Company Address: 7701 W Hanna Ave
Company City: Tampa FL 33615
Company Phone: (813)885-2258
Company E•Mail Address: neil@hvacdeslgns.com
Company Website: http:llwww.hvacdesigns.tom!
Design Data
Reference City: Zephyrhill ,Florida
Building Orlentation; Front Door faces North
Daily Temperature Range: Medium
Latitude: 28 Degrees
Elevation: �g g,
Altitude Factor: 0.999
Outdoor Outdoor Outdoor Indoor Indoor Gralns
Drv Bulb Wet Bulb Rel. um Rel. um Drv Bulb Difference
Winter: 40 37.52 nla nla 72 nla
Summer: 93 77 49% 55°/a 75 43
Check Figures
Total Building Supply CFM: 850 CFM Per Square ft.: 0.565
Square ft.of Room Area: 1,505 Square ft.Per Ton: g5p
Volume(ft')of Cond.Space: 12,041
Building Loads
Total Heating Required Including Vendlatlon Air: 19,896 Btuh 19.896 MBH
Total Sensible Gain: 15,928 Btuh 81 °/.
Total Latent Gain: 3,685 Btuh 19 %
Total Cooling Required Including Ventilation Air: 19,613 Btuh 1.77 Tons(Based On 75°/a Sensible Capacity)
Notes
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculationc are performed per ACCA Manual J 8th Edition,Version 2,and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to selsct a unit that meets both sensible and latent loads according to the manufacturers performance data at your design conditions.
Monday,November 04,2013,11:20 AM
Rhvac-Residential&Light Commerclal HVAC Loads Elite Sottware Development,Inc.
HVAC Designs � Walnut Grove TN 1505 N
Tampa,FL 33615 Page 2
Manual D Ductsize Data-Duct System 1 -Supply
-Duct Name,etc.
Type Roughness Diameter Velocity SPL.Duct
Upstream Temperature Width Loss1100 SPL.Fit
Shape Length Height FitEq.Len SPL.Tot
Sizin CFM Area SP.Avail SPL.Cumul
-Duct Name:SMT•100,Feeds Into:Foyer,Fitting:l•A,Effective Length:27.4
Trunk 0.003 14.2 729 O.OUS
Up:Fan 57 12 0.086 0.018
Rect 6.0 14 21.4 0.183
Schedule 850 26 0.097 0.227
-Duct Name:SR•100,Supplies:M Bath,Fittings:ll-B,11•B,4AA,11•B,Effective Length:18.2
Runout 0.01 4 206 0.006
Up:ST-110 57 3.1 0.050 0.003
Rnd 12.1 4.4 6.2 0.009
Schedule 18 12.6 0.040 0.283
__. _. ___. _.__... _ _.. . __. __ _ _ _ _..._.. _ ...._ ___.... _.....__
-�uct Name:SR-110,Supplies:M Bed,Fittings:11•6,11-B,4AA,11•B,Effective Length:23.4
Runout 0.01 6 576 0.027
Up:ST•710 57 4.7 0.211 0.022
Rnd 12.9 6.6 10.5 0.049
Schedule 113 20.3 0.000 0.323
_ .. ___ _.__ _.... _ _ _........ __.. _... _
-Duct Name:SR-120,Supplies:M Wic,Fittings:11-B,11-8,4AA,11•B,Effective Length:14.3
Runout 0.01 4 46 0.000
Up:ST•110 57 3.1 0.003 0.000
Rnd 9.2 4.4 5.1 0.000
Schedule 4 9.7 0.049 0.274
-�uct Name:SR-130,Supplies:Greatl Dining,Fittings:11•6,11-B,4AA,Effective Length:25.5
Runout 0.01 7 588 0.023
Up:ST•110 57 5.4 0.178 0.022
Rnd 13.0 7.7 12.5 0.045
Schedule 157 23.9 0.004 0.319
-Duct Name:SR-140,Supplies:Great 1 Dining,Fittings:ll-B,11-B,4-AA,Effective Length:16.1
Runout 0.01 7 588 0.007
Up:ST-110 57 5.4 0.178 0.021
Rnd 4.2 7.7 11.9 0.029
Schedule 157 7.6 0.021 0.302
-Duct Name:SR-150,Supplies:Bath 2,Fittings:11-B,11•B,4AA,11-B,Effective Length:13.9
Runout 0.01 4 229 0.004
Up:ST-120 57 3.1 0.061 0.004
Rnd 7.1 4.4 6.8 0.009
Schedule 20 7.4 0.057 0.266
-Duct Name:SR•160,Supplies:Kitchen,Fittings:ll•B,11-B,4AA,11•B,Effective Length:23.3
Runout 0.01 6 616 0.027
Up:ST•120 57 4.7 0.241 0.030
Rnd 11.1 6.6 12.3 0.056
Schedule 121 17.4 0.009 0.314
__ _ _ _
-�uct Name:SR-170,Supplies:Foyer,Fittings:ll•B,11•B,11•B,4AA,11-B,Effective Length:13.2
Runout 0.01 4 562 0.019
Up:ST•120 57 3.1 0.354 0.028
Rnd 5.2 4.4 7.9 0.047
Schedule 49 5.5 0.019 0.304
Monday,November 04,2013,11:20 AM
Rhvac-Residential&Light Commercisl HVAC Loads Elfte Software Development,lnc.
HVAC Designs � Wa/nut Grove TH 1505 N
Tampa,FL 33615 Pa e 3
Manual D Ductsize Data-Duct System 1 -Supply(cont'd)
-Duct Name,etc.
Type Roughness Diameter Velaity SPL.Duct
Upstream Temperature Width LossN00 SPL.Fit
Shape Length Height Fit.Eq.len SPL.Tot
Sizin CFM Area SP.Avail SPL.Cumui
-Duct Name:SR-180,Supplies:Bed 2,Fittings:11•B,11•B,4AA,Effective Length:19.1
Runout 0.01 6 647 0.024
Up:ST-120 57 4.7 0.266 0.027
Rnd 8.9 6.6 10.2 0.051
Schedule 127 14 0.015 0.308
-�uct Name:SR-190,Supplies:Bed 3,Fittings:ll•B,11-B,4AA,11-B,Effective Length:18.9
Runout 0.01 5 616 0.031
Up:ST-120 57 3.9 0.311 0.028
Rnd 10.0 5.5 8.9 0.059
Schedule 84 13.1 0.007 0.316
--�uct Name:ST•110,Feeds Into:Great 1 Dining,Fittings:ll-B,11-B,11-A,Effective Length:58.4
Trunk 0.01 12 572 p,p17
Up:SMT-100 57 9.3 0.081 0.030
Rnd 21.1 13.1 37.2 0.047
Schedule 449 66.4 0.049 0.274
-�uct Name:ST•120,Feeds Into:Kitchen,Fittings:ll-B,11•A,Effective Length:47.6
Trunk 0.01 12 511 0.005
Up:SMT•100 57 9.3 0.065 0.026
Rnd 7.3 13.1 40.4 0.031
Schedule 401 22.8 0.066 0.257
Report Units:Pressure:in.wg,Duct lengths:feet,Duct sizes:inch,Airflow:CFM,Velocity:ftJmin,Temperature:F
Notes: Static pressure available values for return ducts are at the entrance of the duct For supply,they are at the exit The cumulative static
pressure loss value for a return trunk is with respect to the entry point of the return runout upstream with the highest static pressure available. Total
and cumulative static pressure loss values for the supply main trunk include any device pressure losses entered,and the cumulative may also
include the total static pressure loss of the return side.
Summary
Numb�r of active t�unks: 3
Number of active runouts: �p
Total runout ouUet airtlow: g5p
Main trunk airflow: 850
Largest trunk diameter: 14.2 SMT•100
Largest runout diameter: 7 SR-130
Smallest trunk diameter: 12 ST-110
Smallest runout diameter: 4 SR•100
Supply fan e�ernal staUc pressure: 0.323
Supplyfan device pressurelosses: 0.160
Supply hn static pressure available: 0.163
Runout maximum cumulative static pressure loss: 0.323 SR•110
Return loss added to supply: 0.043
Total effective length of return(ft.): 77.6 RR•100
Total effective length of supply(ft.): 109.2 SR•110
Overail otal effective length(R): 186.8 RR•100 to SR-110
Design overall frlction rate per 100 ft: 0.087 (Available SP x 1001 TEL)
System duct surface area(Scenarlo 1): 220.7 Hot Vented Attic (Linked to duct load)
System duct ourface area(Scenario 4): 26 Exposed in Space (Linked to duct load)
Total system duct surface area: Zq6,7
Monday,November 04,2013,11:20 AM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
HVAC Designs � Wa/nut Grove TH 1505 N
Tampa,FL 33615 Page 4
Manual D Ductsize Data-Duct System 1 -Return
—�uct Name,etc.
Type Roughness Diameter Velocity SPL.Duct
Upstream Temperature Width Lossf100 SPL.Fit
Shape Length Height FitEq.Len SPL.Tot
Sizin CFM Area SP.Avail SPL.Cumul
–Duct Name:RMT-100,Feeds From:Foyer,Fitting:SB,Effective Length:48.9
Trunk 0.003 15.3 625 0.002
Up:Fars 75 14 0.056 0.025
Rect 3.0 14 45.9 0.027
Schedule 850 14 -0.016 0.043
—�uct Name:RR•100,Returns From:Foyer,Fitting:2-D,Effective Length:28.7
Runout 0.003 15.3 625 0.001
Up:RMT•100 75 14 0.056 0.015
Rect 1.0 14 27.7 0.016
Schedule 850 4.7 0.000 0.016
Report Units:Pressure:in.wg,Duct lengths:feet,Duct sizes:inch,Airflow:CFM,Velxity:fklmin,Temperature:F
Notes: Static pressure available values for return ducts are at the entrance of the duct For supply,they are at the exit The cumulative static
pressure loss value for a return trunk is with respect to the entry polnt of the return runout upstream with the highest static pressure available. Total
and cumulative static pressure loss values for the supply main trunk include any device pressure losses entered,and the cumulative may also
include the total static pressure loss of the return side.
Summary
Number of active trunks: 1
Number of active runouts: 1
Total runout outlet airflow: 850
Main trunk airflow: 850
Largest trunk diameter: 15.3 RMT•100
Largest runout diameter: 15.3 RR-100
Small•sttrunkdiameter: 15.3 RMT-100
Smallest runout diameter: 15.3 RR•100
Runout maximum cumulative static pressure loss: 0.016 RR-100
Return loss added to supply: 0.043
Total effective length of return(tt): 77.6 RR-100
System duct surface area(Scenario 4): 18.7 Exposed in Space (Linked to duct load)
Total system duct surface area: 18.7
Notes
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculatlons are performed per ACCA Manual J Bth Edition,Version 2,and ACCA Manual D.
All computed results are estimates at building use and weather may vary.
Be sure to select a unit that meets both censible and latent loads according to the manufacturer's pertormance data at your design conditions.
Monday,November 04,2013,11:20 AM
Rhvac-Residential&Light Comme�cial HVAC Loads � Elite Softwa�e Development,Inc.
HVAC Designs Walnut Grove TH 1505 N
Tam a,FL 33615 Pa e 5
Manual D Ductsize-Pressure Changes Graph -System 1
Pressure Changes Through Route with Hlghest Static Pressure Loss
o.rs
��-�.._,
o.�a % ',,-�,_
i, ��.,,`\
0.12 j���� �
� _
% ��
0.10 "-�.__._� �
i ��
�/
0.08 /j" ; \
rn i
�' �\
� 0.06 � � �
! %� � \\
/ '
� ��
a 0.04 � % A \
� � i
i
a %% / ���
�.�2� �'-__ `_` % ,i ��.
'_- _ � ,;
0.00 - - '�
- ----_ _ ;' �`
-0.02 \_'j
._� � �;
-0.04 �--�-,.�
-0.O6
_...�.__...._ Syatic Piessure Available
Total Presswe Available
_... __. . . ............. __.. _._.....
_._..... _.__.._ . ___... __._... .. ........ _..
Notes Return side point values are at entrance of duct,while supply side points are at exit When a return system is present,an addiGonal return
side point named[Fan Entrance]is drawn in the graph to show the static pressure�vailable at the entrance of the fan. When a supply system is
present,and an additfonal supply side point named[Fan Exlt]is drawn to show the static pressure av,ilable�t the exit of the fan. Any device
pressure losses entered for the supply main wunk are accounted for between the fan entry and exit points.
Point Name Static Pressure Available Total Pressure Available
A RR-100 0.000 0.024
B RMT-100 -0.016 0.008
C (Fan Entrance] -0.043 -0.019
D [Fan Exit] 0.120 0.154
E SMT-100 0.097 0.131
F ST•110 0.049 0.070
G SR-110 0.000 0.021
Monday,November 04,2013,11:20 AM
Rhvac•Residential&Light Commercial HVAC Loads � Elite Software Development,Inc.
HVAC Designs Walnut Grove TH 1505 N
Tam a,FL 33615 Pa e 6
Total Building Summary Loads
Component Area Sen Lat Sen Total
Description Quan Loss Galn Gain Gain
OP LOW E MIN.Glazing-NFRC CODE MIN Operable 2 133,1 2,130 0 3,336 3,336
Pane Low E,ground reflectance=0.23,outdoor
insect screen with 50%coverage,light color blinds
at 45°with 100%coverage,u-value 0.5,SHGC 0.5
FD LOW E MIN:Glazing•NFRC CODE MIN Glass Door 2 20 320 0 278 278
Pane Low E,ground reflectance=0.23,light color
blinds at 45°with 100Ye coverage,u-value 0.5,
SHGC 0.5
11N:Door-Metal-�olystyrene Core 40 434 0 343 343
12B-0sw:Part•Frame,R-11 insulation In 2 x 4 stud 177.4 517 0 34q 3qq
cavity,no board insutation,slding finish,wood
studs
13A�4ocs:Wall Block,board insulatlon only,R-4 board 739 3,381 0 1,933 1,933
insulation,open core,slding flnish
16B-30-ad:RooflCeiling-Under Attic with Insulation on 1505.2 1,541 0 2,555 2,555
Attic Floor(also use for Knee Walls and Partition
Ceilings),vented attic,no radiant barrier,R-30
insulation,dark asphalt
22A-pm:Floor•Slab on grade,No edge insulation,no 139 5,249 0 0 0
insalation below floor,any floor cover,passive,
_ heavy dry or light wet soil
--------- ---..---------- --- ------- -----
Subtotals for structure: 13,572 0 8,789 8,789
People: 4 920 1,200 2,120
Equipment: 644 2,040 2,680
Lighting: 0 0 0
Duchvork: 2,159 302 1,980 2,282
Infiltration:Winter CFM:118,Summer CFM:62 4,165 1,823 1,231 3,054
Ventilation:wnter CFM:0,Summer CFM:0 0 0 0 0
AED Excursion: _ __ _ 688
_..... __....._. _ _...
_..... I _.._._ .. _0..... .... .. .. 688
Total Building Load Totals: 19 896 3,685 15,928 19,613
Check Figures
Total Building Supply CFM: 850 CFM Per Square it.: 0.565
Square ft.of Room Area: 1,505 Square ft.Per Ton: gsp
Volume(it')of Cond.Space: 12,041
Buflding Loads
Total Heating Required Including Ventilation Air: 19,896 Btuh 19.896 MBH
Total Sens(ble Galn: 15,928 Btuh 81 °/a
Total Latent Gain: 3,685 Btuh 19 %
Total Cooling Required Including Ventilation Air: 19,613 Btuh 1.77 Tons(Based On 75%Sensible Capacity)
Notes
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition,Version 2,and ACCA Manual D.
All omputed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions.
Monday,November 04,2013,11:20 AM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
NVAC Designs Wa/nut Grove TH 1505 N
Tam a,FL 33615 Pa e 7
System 1 Room Load Summary
Htg Min Run Run Clg Clg Min Act
Room Area Sens Htg Duct Duct Sens Lat Clg Sys
No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM
— one 1—
Foyer 71 2,049 47 4 • 917 80 46 49
3 Bed 2 180 4,154 94 6 • 2,384 440 121 127
4 Bath 2 60 746 17 4 • 376 60 19 20
5 Kitchen 283 325 7 6 - 2,258 500 114 121
6 Bed 3 171 2,131 48 5 • 1,569 221 79 84
7 Great 1 Dining 335 5,602 127 7,7 • 5,885 1,485 297 314
8 M Bed 248 4,708 107 6 - 2,121 517 107 113
9 M Wic 39 45 1 4 • 80 0 4 4
__10 M Bath
---- ---- ----118-- - __136 _- 3 4 '
338 80 17 1g
-- -- —--_ ---_ ------
_ ----302._ --
--— ---- -__
___ __ uct Latent
_
_ _ _
__ _ ____...
_
S.ygtem 1 total 1,505 19,896_ _ 452 _ 15,928_ 3 685 805 850
System 1 Main Trunk Size: 1�c14 in.
_�_ _. _._.
Velocity: 729 ft.lmin
Loss per 100 ft.: 0.086 in.wg
Duct size results above are from Manual D Ductsize.
Runout duct velaities are not printed with duct size results from Manual D Ductsize since they can vary within the room. See the Manual D Ductsize
report for duct velocities and other data.
Cooling System Summary
Cooling SensiblelLatent Sensible Latent Total
Tons Split Btuh Btuh Btuh
Recommended �,�� 75%125°k 15,928
5,309 2�,y37
Actual: 2.08 75%!25°/. 18,750 6,250 25,000
Equtpment Data ,
Heatina Svstem Coolina Svstem
TYPe� A1r Source Heat Pump Air Source Heat Pump
M�e�� 4A6H3024C1 4A6H3024C1
Indoor Model: GAF2AOA24S21+TDR
Brand: HEWTAGE 13 HERITAGE 13
Descrlption: Air Source Heat Pump Air Source Heat Pump
Efflclency: 8.2 HSPF 13.75 SEER
Comment: �
Sound: 0 0
Capacity: 23,600 Btuh 25,000 Btuh
Sencible Capaclty: nla 18,750 Btuh
Latent Capacity: nla 6,250 Btuh
AHRI Reference No.: nla 4941302
Thls system's equipment was selected in accordance wlth ACCA Manual S.
Manual S equlpment�izing data: SODB:93F,SOWB:77F,WODB:40F,SIDB:75F,SIRH:55%,WIDB:72F,Sen.gain:15,928 Btuh,Lat gain:3,685
Btuh,Sen.losc:19,896 Btuh,Entering clg.coll DB:75F,Entering clg.coil WB:63.9F,Entering htg.coil DB:72F,Cig.coil TD:18F,Htg,coil TD:40F,
Req.clg.airflow:805 CFM,Req.htg.alrflow:452 CFM
Monday,November 04,2013,11:20 AM