HomeMy WebLinkAbout14-14954 CITY OF ZEPHYRHILLS
5335-8TH STREET
(sis)�sa-oozo 1 49 4
BUILDING PERMIT
Permit Number: 14954 Address: 37632 LORENA AVE LOT 127
Permit Type: RE-ROOF ZEPHYRHILLS, FL.
Class of Work: ROOF REPLACEMENT Township: Range: Book:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Square Feet: Subdivision: GRAND HORIZONS
Est. Value: Parcel Number: 34-25-21-0090-0000001270
Improv. Cost: 6,000.00
Date Issued: 2/07/2014 Name: ADAMS DAVID A & MARGARET K
Total Fees: 97.50 Address: 37632 LORENA AVE
Amount Paid: 97.50 ZEPHYRHILLS FL 33542
Date Paid: 2/07/2014 Phone: 300-307-4011
Work Desc: REROOF METAL
�.
���' , -
�
v
TAPE JOINTS ROOF iNSP�
FINAL
REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80(2)(c)when eutra inspection
trips are necessary due to any one of the following reasons: a)wrong address b)condemned work resulting
from faulty construction c) repairs or corrections not made when inspections called d)work not ready for
inspection when called e) permit not posted on job site� plans not at job site g)work not accessible.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your properly. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans, Specifications Must Accompany Application.All work shall be performed in accordance with
Ci Codes and Ordinances. NO OCCUPANCY BEFO C.O.
� • r�
CONTRACTOR IGNAT RE PERMIT OFFI R
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
813-780-002Q City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
Date Received �''.. ',�
� �� Phone Contact for Permittin �/ �1� __ ���
Owner's Name '� w�� f�`L,�s*-��'7 `� Owner Phone Number .�3G '�C%- �C j,
Owner'sAddress _' /�° i„� �..U,%�.i4%� ���� �
Owner Phone Number
Fee Simple Titleholder Name Owner Phone Number
Fee 3imple Titleholder Address
JOB ADDRESS �7 ,�4:> �,7 ;^G��C-/l."-I ���� LOT# �� �
SUBDIVISION �/' � ��rJ/��/`�/%� � PARCEL ID# �T �.� '���� ,� �C` , T���7��� „ �
(OBTAINED F�PROPERTY T�TicE)DEMOLISH
WORK PROPOSED NEW CONSTR , " ADD/AlT � SIGN
INSTALL � REPAIR
PROPOSED USE Q SFR Q COMM [� OTHER
TYPE OF CONSTRUCTION Q BLOCK Q FRAME C� STEEL Q
DESCRIPTION OF WORK �l��� Gr/,(1� `" j/,�/i G�"3 l�/Ti'�- Gf,G�'-/�j� ,�yC��y� �'CL�arCr -
BUILDING SIZE SQ FOOTAGE ;�rY_�C� HEIGHT
BUILDING ) VALUATION OF TOTAL CONSTRUCTION
$ �f.�C:�,�
QELECTRICAL $ AMP SERVICE � PROGRESS ENERGY Q W.R.E.C.
QPLUMBING $
QMECHANICAL $ � � ��
VALUATION OF MECHANICAL INSTALLATION �
QGAS � ROOFING Q SPECIALTY �_] OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA QYES NO
BUILDER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N
Address License#
ELECTRICIAN COMPANY
SIGNATURE RE�isreREO Y/ N FEE CURRE� Y/N
Address �
License#
PLUMBER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREP Y/N
Address License#
MECHANICAL COMPANY
SIGNATURE GISTERED Y/ N FEE CURRE� Y/N
Address License# -�
OTHER _��r;y� � COMPANY /,� �-{ �lia✓-7 /�tr�G~ ,,,:.�
SIGNATURE Ki�� REGISTEREO Y N FEE CURRE� Y/N
.�.° ,
Address , L � � , � 33 S G� License# L`C.:�:l'y'�1� ��
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Ptans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working days aiter submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Fadlitles 8�1 dumpster;Site Work Permit for subdivisionsAarge proJects
COMMERCIAL Attach(3)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(10)working days after submlttal date. Required onsite,Conshuction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities 8 1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
"*"PROPERTY SURVEY required for all NEW construction.
T1111111l�1�11����11���1 A��11�
Directions. '
Fill out application completely.
Owner&Contractor sign back of application,notarized
if over 52500,a Notice of Commencement(s required. (AlC upgrades over E7500)
"" Agent(for the contractor)or Power of Attomey(for the owner)v�nould be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (Front of Appflcation Only)
Reroofs if shingles Sewers Service Upgrades A/C Fences(PIoUSurvey/Footage)
Driveways-Not over Counter if on pubiic roadways..needs ROV1/
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contrac or or
contractors to undertake work, they may be required to be licensed in acco�dance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor vif�lat{he
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply
intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this apptication for which they will be responsible. if you, as the °v leges9n Pasco
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting p
County.
TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understan s
that Transpo�tation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or
final power release, the fees must be paid prior to permit issuance. Fu�thermore, if Pasco County Water/Sewer Impact
fees are due, they musi be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I
certify that I, 1he applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner" prior to commencement.
CONTRACTOR'SIOWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicabie laws regulating construction, zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be perFormed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that i unde�stand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
- Department of Envi�onmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment.
- Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
Army Corps of Engineers-Seawalis, Docks, Navigable Waterways.
- Department of Health 8 Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency-Asbestos abatement.
Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill:
Use of fill is not allowed in Flood Zone"V" unless expressly permitted.
If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this a�davit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to.violate, cancel, alter, o�
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter
requiring a cor�ection of errors in plans, construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension
may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate
justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINAMENT.� CONSULT
WITH OUtz L NDER OR AN ATTORNEY EFORE RECORDING Y UR NOTIC F
FLORIDA JURAT(F.S. 117.03) � 1�.����t`l/"
OWNER OR AGENT CONTRACTOR S
Subscribed and s afftrm�� ��
Subscrtbed a�d swom to(or affirmed)before me this . .�
b by
y
Who is/are personally known to me or has/have produced Who personall n wn`tirmeoc aslhhave oduced
_ ._. ag�ntlfication.
as identlflcaBon.
�.... .
t�ry Public
Notary Public ,, �
��'� ';:� Commission#EE 140709
Commission
CommissionNo. '?� F��.�• �wncledThruTroyFainlnsurance800385-7�79
R,,,
ed, rfnted or stamped Name of Notary lyped,Printed or stamped
Name of Notary typ P
f
City of Zephyrhills
BUILDING PLAN REVIEW COMMENTS
,
� tr omeowner:
C � � o
Date Received: '� � �
Site: �/J�� � ,�Q� � m
Permit Type: ` _
� �'� �� o
Approved w/no comments: Approved w/the below comments: LJ D ed /the below comments: ❑
This comment sheet shall be kept with the permit and/or plans.
�ia,��r�v;� ' FEB � �+ 2014
Kalvin Switzer—Plans Examiner Date Contractor and/or Homeowner
(Required when comments are present)
�1—
_
— - -
--- — —��,—_
_-- ,—
_ —
-- — --
_-- ,- 1 ► _ _ _�—_—
��;:.--- ,� � �--
� ;' l'"�
i ,' .
� i
L� Force Engineering& Testing Inc. M �
19530 Ramblrwood Drivc V
Humble,TX 77338
Product Evaluation Report
GULF COAST StlPPLY& MANUFACTUR/NG, tlC.
29 Ga. Tuff Rib Roof Panel over 1x4 Wood Purlins
Florida Product Approval # 11651.27 R1
Florida Building Code 2010
Per Rule 9N-3
Method: 1—D
Category:Roofing
Subcategory:Metal Roofing
Compiiance Method:9N3.005(i)(d)
NON HVHZ
Product Manufadurer:
GULF COAST SUPPLY&MANUFACTURING,LLC.
4020S.W.449�'Street ALL���I)I'.1C51-1i�1 Ct ����='LY�'Yii���I�:LL
Horseshoe Beach,Florida 32648 pRFVAILING C'�:��:5. t LORID;�13U1LUING
COI�L,��I:,i it�;�;'-�:L�.L,`_:��'�IC COD�AND
EneineerEvaluator: �:l-,,`'�� 'c=;'i�` ;'t� � `;t.�?I?i�'%a;v(��S
Terrence E.Wolfe,P.E.#44923
Florida Evaluation ANE ID:1920
Valida or:
Locke Bowden,P.E.,FL#49704 p �. .�
9450 Alysbury Place ��'�l������- FEp � 1�
..� ._ ,,--. ,__,._•�►+►�i
Montgomery,AL 36117 �•�` ��� �'�}�}.������! �
`';-;�NS ±=,�,+� n�� �
ntentr �L'cLhiyi._ •
Evaluation Report Pages 1-4
,`���Itt�f��<<`'
♦�� ��.0 E• �.ry ��i
�t�,4:��, � � E N s F �'�`�,,
- : �t. _ •<^,,�r, -
� ' - No.4�9�F' . 1'�►^ `''�,
� � � ., �
. "rr ��"f----'
+ ��,�.�;%'-?�".� 7-_: *�`_ . '�jk� �'
. L.. � ..._ � ..
V � A� �A�� � .
.4�'
i ��, �
���: FLORI �4' •�``'��•
sr»ar„m � s;.,. ,G•�,,��
OAA I� S
��snr ��I��k 1 1�t�����
FL#11651.27 Rl
February 22, 2012
�
_-�/�..`__�
--- — ,�`.-,.
�--``�--''' ,.� _.-,._�. -_._, ���_
_ I' � ` _
�f�-- � �'_`_
i�' '� ��_' _\�;
� � C '
' I
�? Force Engineeting& Testing Inc. �, i
19530 Ramblewuod Drive LJ
Humble,TX 77338
Compliance Statement: The product as described in this report has demonstrated compliance with the
Florida Building Code 2010,Sections 1504.3.2,1504.7.
Product Description: Tuff Rib, '/." Rib Roof Panel, Min. 29 Ga. Steel, 36" Wide,through fastened roof
panel over 1x4 wood purlins over one layer of asphalt shingles (optional) over
min.7/16"OSB or 15/32"Plywood decking. Non-Structural Application.
Panel Material/Standards: Material: Minimum 29 Ga.Steel,ASTM A792 or ASTM A653 G90 conforming to
Florida Building Code 2010 Section 1507.4.3. Paint finish optional.
Yield Strength: Min.80.0 ksi
Corrosion Resistance: Panel Material shall comply with Florida Building Code
2010,Section 1507.4.3.
Panel Dimension(sj: Thickness: 0.014"min.
Width: 36"
Rib Height: �:"major rib at 9"O.C.
Panel Rollformer: MRS Metal Rollforming Systems
Panel Fastener: #9-15 x 1-1/2"HWH Woodgrip with sealing washing or approved equal
'/."minimum penetration through plywood
Corrosion Resistance: Per Florida Building Code 2010,Section 1506.6, 1507.4.4
Substrate Description: Min.lx4 No.2 SYP wood purlins over maximum one layer of asphaft shingles
(optional)over min.7/16"OSB or min. 15/32"thick over supports at maximum
24"O.C. The 1x4 wood purlins shall be fastened to the wood rafters(24"O.C.
Max)with(2)9 x 2'/:"Deck Screws per rafter(Minimum 1 7/8"embedment into
wood rafiter). Design of lx4 wood purlins,05B, plywood and OSB/plywood
supports are outside the scope of this evaluation. Must be designed in
accordance w/Florida Building Code 2010.
Design Uplift Pressures:
Table"A"
Maximum Total Uplift Design Pressure: 101.0 psf
Fastener Pattern: g�_g�_g•_g��
Fastener Spacing: 24"O.C.
'Design Pressure Includes a Safety Factor=2.0.
',��{f{11/���',
�
���, �N�C E� ��`0,��
;�Q.Q'� ` CENS� ,C,��.
� �c.. _. .d►�,�r, _.
: No.M9� • � �-�'yr
� ' ;� ,� '�
(I�, �•, �4 ��'-_. „ •�*, �,. __
`'.,�. ti%1^uc.-y-_- . -
• �a' STATE OF :a� ,,
.l
. P'.
♦
s.r��ra� %�i^ FL O R 1 V P' �4'`":�
� .G�.�.,�
i� �ii'41'' • ' �1 a
,���O►f111�►`,`'
FL#11651.2�x1 February 22, 2012
�—�T��_
— � -
- —' , �-�
__ , __
--� - ' ► �
��-' � {, `'-�i�i
� � ;
iI ; ,� ;
� Forcc Engineering&Testing Inc. �
� 79530 Ramblemoud Dtive ,�--'
Humble,TX 77338
Code Compiiance: The produd described herein has demonstrated compliance with
The Florida Building Code 2010,Section 1504.32,1504.7.
Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load
requirements of the Fiorida Building Code 2010,as relates to Rule 9N-3.
Performance Standards: The product described herein has demonstrated compliance with:
■ UL 580-06-Test for Uplift Resistance of Roof Assemblies
■ UL 1897-04-Uplift Test for Roof Covering Systems
■ FM 4471,Section 5.4-Foot Traffic Resistance Test
Reference Data: 1. UL 580-94/1897-98 Uplift Test
Force Engineering&Testing, Inc.(FBC Organization#TST-5328)
Report No. 117-00407T-09,Dated 11/16/09
2. FM 4471-95,Section 5.4 Foot Traffic Resistance Test
Force Engineering&Testing,Inc.(FBC Organization#TST-5328)
Report No. 117-0238T-09E,Dated 07/21/2009
3. Certificate of Independence
By Terrence E.Wolfe,P.E.(No.44923)@ Force Engineering&Testing,Inc.
(FBC Organization#ANE ID:1920)
Test Standard Equivalency: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard.
2. The UL 1897-98 test standard is equivalent to the UL 1897-04 test standard.
Quality Assurance Entity: The manufacturer has established compliance of roof panel products in
accordance with the Florida Building Code and Rule 9N-3.005(3)for
manufacturing under a quality assurance program audited by an approved
quality assurance entity.
Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2010,including Section
1507.4.2 and in accordance with Manufacturers recommendations. For slopes
less than 3:12,lap sealant must be used in the panel side laps.
Installation: Install per manufacturer's recommended details.
Underlayment: Per Manufacturer's installation guidelines per Florida Building Code 2010 Section
1507.4.5.
,��ti{itlf���j',
♦ �
��� �N.0 E, �. � ���
.`��Q'y � C � NS���%,
: 4r, �
- � �. _. •,tn�r, _
t "' No.�4�9�� • r• �-''y,
.
� .� �� i� ,y� '�-E
� �'1 ���.' ` ;'�'
�,'�u�r o � —
' ' r f'-:� 9-' *�
�� �_ . _ , y,,
� 'O' STA7L'Of :Q,•'
. p'.
.
�'�`t:�'L 4 RI V?► �4.�:
i �1,��
�ic`�rn ��i SI� ' •-• ''�1 ♦
FL#11651.27 Rl '�`,Q�������,`,
February 22, 2012
_--- �;—�'�\�
i4-_ ��' � _.�T ' \`_= `�`�
I � � i
� ' , Ij
��� Forcc Engincenng&Testing Inc. ! I
19530 Ramblewuod Drive �`�
Hun�ble,TX 77338
Roof Panel Fire Classification: fire classification is not part of this acceptance.
Shear Diaphragm: Shear diaphragm values are outside the scope of this report.
Design Procedure: Based on the dimensions of the structure,appropriate wind loads are
determined using Chapter 16 of the Florida Building Code 2010 for roof cladding
wind loads.These component wind loads for roof cladding are compared to the
allowable pressure listed above.The design professional shall setect the
appropriate erection details to reference in his drawings for proper fastener
attachment to his structure and analyze the panel fasteners for pullout and
pullover.Support framing must be in compliance with Florida Building Code 2010
Chapter 22 for steel,Chapter 23 for wood and Chapter 16 for structural loading.
,'��{If11lf(lf
♦��, ft,�•�E• �•,�1,r'��i
��
♦
� Q�Q"� � C E N/S •l �i
� � fi �
t �~�• I+la.419�`� '�`!�1 � •'�,
r � �� • �+ '�F
� !i � *f` . .. {�*�.r _
. ,��k-,��_c 7- _. - �' _...
y--. " " r
v �� �A�� .Q`•=,,,
• ��.
♦
;,�'`•�:?AL 4 R 1 �A.•�4'``'�
�� ���;S`. - � �G;,+�
�i� �kAl � ���
FL#11b51.27 Rl February+LL,�2012
� - __.._
29 ya_rianl�+wm Tuff Fb6�"W#19 O1KH'T M 4 WQtX/Ftlrli[IS . __ .__.____._--_._._...�.,
` TUF�-R!B EXRQSED FAST�NER SYSTEM .
. i
;
�...,..._._�.�.._..___._........._...._--- . _........�.--- 36"O.C.
; , NOMENAL COVERAGE_._..._...__._.. . .._.__.... .
'� �, +a-------9" —r't--_._.._._.__g�= _,�._ __ .._........... ...�, ;
j ___ _ -9" --�►�-_-_—_._._.._y4_....- - ...__iy i
;._._____.-.._..__ '� � ` ; , ;
. :1 �'--• �-----'-,.._.�.��,.�„_,_,____�.�___— j'\ .�. ,_,�_f�,-.,_._...._...
.� ��,�_s.,
� � ,
a � ��� '� �9-15 X 1:5"aVOfl� �CRE4'U
� f ...— ' T1'P1C�l. FASI'ENER PATTEf�N WlWASNER ;
,� ~•,
'�_'!,x 14-7t8 tAP't'E!C ,." rc:• ;�,'• `:
�% �,. .
j � j V11/WASt�ER 24".O.C,ANR - V ;
� _ °''COhI't'lNUOUS 1'AP�SERt i
j �• REQUIRED IF LESS THAN �
_ _ ��2P�T�H ,
i
� "�—��fa'..p,,,4_,..:_....��f�n..,_.__—a` .-2+j2",y:,l....... �e..... � '
�
, o �
, i � ''a 7 -2/s �:•v�- --5Ya" t �
. � . _._►�<-2h"-1.�t-- ..__5'lx"_.._..y�.2/a"r's
� —���� � � i r-�' ,
} i ` � � � �----�`^-----" �
� i
� � -TYPE 2 + i' �
! a���av;9sasag�r �ASTFlUER PATTER� t�}a PANEL END$� LAPS f
Q� ��,�1��'. �p.
1 _q�. y i - Lt���d r
� M
� �a�,��'�;.w�C lil��.v !r tl fi�ttouee�a�a :
t
m s - t t A.4�9�23j., A oa�is�e i
� :'�S'a �` t,� ���a
.e � �. k'
( w
f 9� tr � j� . ,.
�``o• jC,����A« �r4�' . / � .'� . ..
... 'pa °,� _�^ �� . .�' GUt� 5 •
. �g',� ° .. .. �^� .��_;�..«\ : � �: . COAST StlP. ..Y&Wt�G. !N ,
. '�•O. . F✓ .,..Y_...r.:._.. 1
; � ��p�le4a,o= _-- .�.. 4020 SW 44� BTREET � ,
� , �
" HORSESNOE B��.CH, FL 32648 ;
; ��8...�_9__�p1.�._�.__�_.-----..._.._
88&39��•J335
i iiiiii iiiii iiiii i�iii iiiii iiiii iii�i uui iiiii uiii iiii iui
2014016301
Permk No. Pucd ID No :37'a J�—��—�09��QQ�fQ�—/oZ'�
NOTiCE OF COMMENCEMENT
��of Fr,o2�oa- ��,�,�,o< <P�sco
.
THE UNDERSIONED hereby pivac notice that ImprovemeM wIY be made W cerfein rc�property,and In accordance wfth Chapter 713,Floride Stah�tes,
1he followinp Intamatlan fe prowded in tlde No11ca of Commanf,fement: '`-,,
i. Dacafptfon o�Praperty: ParcalldenlMcatlon No. IIQAM�{�X/204JS-�AS�D,u�- ����s�ica��a�oRl��
sne�naa�: 3'I�02 L.oi2��✓A A�✓f 7_�PM'/�-l�LS �C. 335�!/ �
z. Oeneral Deacriptlon ot lmprovemerrt ��—(�CXJ� 1C�SI�A�
I �
3. Owner Infortnatlon or Lasaee Mform�tlon if the Leesee ca�traded for tl�e improvanent•
1�liD A-DA�.S
�Q�-1�ou�mcA� �Sr°2rN1�5 �oA-O 5� W�-2.et'1(/ O�H: yy�
Addresc ����� City State
I Interest In Property:
, Name oi Fee Simple TlUahdder. /�
Qf dllfarent from WYt�x Ysted above)
R Co��a: T�ic� C2owN 20oF•�+/� C�Y State
�SG�� ,���� cS�'t� ZE`/NY2f�/cGf /CL ,3,�5��0
��� 8i3�3.3-?"l�o °i� �°
Contreda's Talephane No.:
5. surety: Rept:1B788�4 Rsc: 10.00
iName �. D5: 0.00 IT: 0.00 J`.` � *
i 01/31/14 E. Munyuia, Dply Cle�k
, Aed►ess �Y - � �b� `Q.G • ' '• *
AmouM of Bond: S Telephone No.: � 6
8. lendx: � � �
Name � � .� �
Addreea Cily Sfete � •. !S � � �
Lenders Telephone No.: � • �, "' • �
� �� ' �A
7. Peraons witldn the SYate ot Flo�ida desi�eted by the owner upon whom noticea a other doeuments may ba served as proNded by t 3
Sectlon 713.13(1)(aH�,Florida StaLrtes: -�� ° �,�`�'
. � _ _ .�j� , . * r
Name /� * *
PRULR 5.0'NEIL,Ph.D.Pq5C0 CLERK 6 CONPTROLLEF
01/31/14���� 1 of 1
A�'"B8 �' OR BK
Tdephone Numbu of Desipnated Person: _ � 3319
8, In edd�tlon lo himsdf,the owner desipnates °�— � W Y
to roceiva a copy of ihe Uenors Notice p prouldsd In Sectlon 71 J.13(1Nb),Florida StaUrtes. Q z U �
Tdephone Number oi Pe�aon or Entily Desipnated by Ownar: � � �� � � U
8. ExpfraUon date oi Notice�,Commenceme�rt(the explraUon date mey not ba beforc 1ha complelton of constructlon and Msl payment to the � Z V�� � �
contrador,but wip be one year from the date oT roeordinp unlese a dNferant date k speelfed): a �Q� Q N� a
WARNINO TO ONMER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT 4. W W � a W
RESULT�IN YOUR PAYINOPNNCE F�ORNIMPR01/EMEPITH�ORYOIIRPPROP�RTY.nA NOTICE� OF COMMENCEMEN'F MUST 8E � O = z —� O
RECORDEO AND POSTED ON THE JOB SITE BEFORE THE FIRST IN3PECTION. IF YOU INTEND TO OBTWN FINANGN(i,CONSULT � u- ~ � Q O '
1MTH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING VYORK OR RECORDIN(3 YOIAt NOT CE OF COMMENCEMENT. Z =O O� V
Undu penedty oi pe�ury,I dedaro that i have read Ihe forepofnp notice of commencement end that the fada st�ed tlie►dn are true to the baet � F— } U �y, °�
of my knowledpe and bdlef. 0 F— Q- �O Y
STATE OF FLORIDA �/ � // � �UO U �W ���
COUNTY OF PASCO �� �.Z. �r.i1s�.�
'Q �' F— JQ
, SlpnaNre of Owner a Leases,or Ow�a's ar Lessaa's Aulh¢rizad � l}i_. kk! � � tt_
' Oflfca/Diredor/Pat4ier/Manape► � Z O J
o'U[ � l.� S QW
J �y 0 0 � Z
Sl�atory's Tltle/Oflfee � �1 p � � O
The torepofnp inatummt was eclaiowled d beiwe me 1hk�day o� ,20�,,by�y�• 0 IH � C� `
zW (n� ' n
'', as (type of ulhodty,e.p.,ol6cer,trua ,aqomay in fact)fa ��w � Z —�
(name a beh o me w c execute�. �a� � f-- � � ~,�
Personaly Known�Q$Produ Identlfieetlon Notary Signehire
mH— F— OS' a m
Type of IdenlMcetlon Produced Name(Print) �
MNIYIlf1�
MY Cqlht$SION 1 FFQ28817
EXPNE&Jin!12,2017
' ead�a nw warr Pwee u�rr.w
i wpdatsJbcslnoticecommencement�c053048
. ��i ��� • ��'B
•
� � �
TRIPLE CROWN ROOFING INC.
37625 STATE ROAD 54
ZEPHYRHILLS,FL 33542
813-833-7720
STATE LICENSE CCC049370
SPECIALIZING INALL TY�ES OF METAL ROOF SYSTEMS
We hereby submit specification and work description:
NAME PHONE DATE
�;�: : �'i�.�����r�a �'�,� .��; _ , .��, ,� _ �.�, �
STREET CITY STATE y ZIP
_.�°r' . ;�--',
, r' „��`` ,c:_, :� �'L. .Lrr`l` f ' : r.. �'� f..;,. f X,;. . . ,/`�`�' _
SALESMAN , �, ��
, , , ,
� �!
�_f_,,�/Z,�1 .fE,i,<t c��, i
� : , a
: , ,
�`"��/ ft! t��t.. r!_= ,�:>..�,(:?; � , ';.r. , �;�;`<' i�'!"%!.r r2'� i /'_/
.. � . � . ,� ,. ..l .��'' � < �J
d;`f°.�,�"; : 4 °��.. .
f 4:..t d'r't /'i;//%',Iid:I.I rr " ' •: r' ,,�' / > ' -
. V :.'� ,,1� . -,/�'� " r..< ' r'- ..if.�y C� C___;
.,� ,
;
�.� ,- � � _ . . -� ,�� , .� , �, � .(�t: ,�:,'����.�.' .'��/'�. ..'� ff�. . .. �..�/�;� ��.
/L
, , _ y ., ..., . �.
< . ' .r. •, : ..
. , �
f�/' f _. ! f. �- { � 'l�I / .: !., .�/�(� �r'C.. c,_.+'f � /, %'r�
� , . ;'
• _ ,
.
� � '
.
'�,' ! ,.'.. .. �' ... ,.'/r' /. ,,, : .0 ,s ;:+ : ' �r✓f t.f:�. .. ,/�i � � ... �
f . � ''�'��✓�.l�E.. �f.,;�f l
�'^ . __
THE ABOVE DESCRIBED WORK WILL BE COMPLETED ACCORDING TO SPECIFICATIONS, FOR THE SUM OF
($ (,;. ���c� ). PAYMENT TO BE MADE AS FOLL�WS:$ 3 �7 AS DOWN PAYMENT �
BALANCE OF$ ,: i�� DUE UPON COMPLETION.
***ANY ROTTED WOOD DISCOVERED WILL BE AN EXTRA CHARGE AT A COST OF$ PER 1/2"SHEET OF
PLYWOOD$ Lin. Ft. Lumber.
NO ORAL AGREEMENTS HAVE BEEN GIVEN OR ACCEPTED. THIS WRITTEN CONTRACT IS THE
ENTIRE AGREEMENT�COVERING ALL THE WORK TO BE PERFORMED AND/OR MATERIALS TO
BE FURNISHED. THE WRITTEN PORTION ABOVE IS THE ENTIRE CONSIDERATION FOR THE
AMOUNT OF THE CONTRACT. PURCHASER MAY CANCEL THIS CONTRACT ANY TIME PRIOR TO
MIDNIGHT OF THE THIRD BUSINESS DAY AFTER THE DATE PURCHASER SIGNED THIS
CONTRACT.
IT IS AGREED:
Contractor will do all said work in a good and workmanlike manner and in strict accordance with the ordinances, rules and requirements of the city,
Town or Viilage,wherein the above mentioned property is located. If purchaser should cancel this contact after time stated above, the Purchaser
agrees to forfeit down payment paid. In the event it becomes necessary for Contractor to employ an attorney to collect any sums due the
Contractor pursuant to this contract, then the Purchaser shail pay all reasonable attorney's fees incurred by the Contractor. This contract shall not
be binding upon Contractor until accepted by them. Upon such acceptance by said company, this contract shall be binding on me/us without any
further notification to melus. The undersigned property owner agrees that this contract may be assigned for the performance of the work and labor
required by the description of the work to be performed. Upon assigned the parties hereto consent to the pertormance of the work by and payment
to such assignee of the amount of this contract. Any Alteration or deviation from above specifications involving extra costs will be executed only
upon written orders and will become an extra charge over and above the stated contract amount.
NOTICE TO THE BUYER : (1) Do not sign this contract before you read it or if it contains any blank spaces. (2) You are
entitled to an exact copy of the contract you sign. (3)Under the law you have the right to pay off in advance the full amount
due and under certain circumstances to obtain a partial refund of the time charge. Owner acknowledges receipt of a true
copy of this CONTRACT.
; ,
r�� � !: �.� ,�'� ; PURCHASER DATE
,�"i, � „� �`, ,. , l�,f� F�
� BY:Triple Cr�wn Roofing, Inc. DATE PURCHASER DATE
This contract is enforceable only when accepted by management of Triple Crown Roofing,Inc.