Loading...
HomeMy WebLinkAbout14-14834 CITY OF ZEPHYRHILLS 5335,.—8TH STREET (si3)�so-oozo 14834 FIRE ALARM SYSTEM PERMIT Permit Number: 14834 Address: 7350 DAIRY RD Permit Type: FIRE ALARM SYSTEM ZEPHYRHILLS, FL. Class of Work: FIRE ALARM SYSTEM Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 35-25-21-0010-06900-0020 Improv. Cost: 49,500.00 Date Issued: 1/02/2014 Name: ADVENTIST HEALTH SYSTEM Total Fees: 150.00 Address: 7050 GALL BLVD Amount Paid: 150.00 ZEPHYRHILLS, FL. 33542 Date Paid: 1/02/2014 Phone: (407)975-3000 Work Desc: REPLACE FACP 8� BRING TO CODE 5 . . r �. � �/ , �� -- I � � ina FIRE ELEVATOR RECALL Chapter 633, Florida Statutes,authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activides such as inspections, plan review,administrative fees,and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Acrnmpany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of$100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." "�` �1 � � �,�� `' � ),�,d CONT,RAC OR SIGNATURE - PERMIT OFFICE � PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOURS NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT-813-780-0041 s�saso-oo2o City of Zephyrhills Fire Fax-813-790-0021 Permit Application ate Received �—� Phone Contact for Pertnit � y(�� � wner's Name , —}- c.,E.h�� Owners Phone Number ��� [-1-� , � , �.7="J wner's Address �' � ''� 33 f :e Simple Titleholder Name '� -- Titleholder Phone Number � �� � :e Simple Titleholder Address �b Address 3 S� z2 h o�(-s � �3 S�� Lot tF � �b Division Parcel# _ _ , _. � Bio-Hazard Waste Storage-ANNUAL � Fumigation Tent � Comm Exhaust Kitchen Hood/Duct � Hazardous Material�er II or RQ Facility)ANNUAL � Controlled Bum � Hood InstallaUon � Emergency Generator<30 kw � LP/Natural Gas-Installation � Emergency Generator>30 kw � LP/Natural Gas-ANNUAL Sale � Fire Protection Maintenance-ANNUAL � Places of Assembly-ANNUAL , � �y emi �n r I ��� Sprinkler � ❑ � ❑ � � Recreational Bum �! Fire Alartn � ❑ ❑ ❑ � � Sparklers Hood Cleaning � O ❑ � � a Sprinkler System Installations Hood Suppression � ❑ ❑ ❑ � � Standpipes(Sprinkler Sys) � Fire Alarm Installation � Torch Roofinglfar Kettle � Fire Pumps a Waste Tire Storage ANNUAL � Fire Works a Flammable Application-ANNUAL - S'r�-- Valuation of Project � Fuel Tanks Other. n A� � ,� mtractor Lr_c..0 Company gnature 'f�J.�^^"— �1 dW`T(�(, /nJ I��c� �� Registered Y/N Fee Current Y/N Address License# _ECTRICIAN Company gnature Registered Y/N Fee Current Y/N Address License# _UMBER Company gnature Registered Y/N Fee Current Y/N Address License# =CHANICAL Company �nature Registered Y/N Fee Current Y/N Address License# fHER Company �nature Registered Y/N Fee Current Y/N Address License# rections: Fill out application completely. Owner 8 Contractor sign back of application,notarized(Or,copy of signed contract with owner) If over$2500,a Notice of Commencement is required(Mechanical work over$5000) Supply two(2)sets of drawings with appiicable documentation Allow 10-14 days for review after submittal date. Paroel#-obtained from Property Tax Notice(http://appraiser.pascogov.com) NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The �ndersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILiTIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. CONSTRUCTION LIEN�.AW�Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owne�", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. - CONTRACTOR'SIOWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do wo�k and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be perFormed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S. 117.03) 4��'Jv- OWNER OR AGENT CONTRACTOR " _'� Subscribed and swom to(or affirtned)before me this Subscribed and swor to(or r ed) fore me this by by��������c f�� Who is/are personally known to me or has/have produced Who is/are personally known to or has/have produced as identification. as identification. Notary Public Notary Public Commission No. Commission No. Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped !Illill Illll INiI lllll IIIII IIIII IIIII IIIII IIIII Illil IIII IIII aeiaeeeas2 NOTICE OF COD�F'MENCEMENT Permit No. Rcpt,:1372727 Rse: 50.00 Property Idcntificatian No. DS: 0.00 ET: 0.00 01/02/19 D. Bonilla, Dply Clsrk 1'F[E l3NDERSfGNED hereby gives notice that improvements will be made to certain real property,and in accordance with Scction 713.13 of the Clorida Statutes,the following information is provided in the NOTICE OF COMMENCEMENT. 1. Description of property(legaJ descripllon:� �PHYRHILLS COLONY COMPANY LANDS PB 2 PG 8 A PORTION OF TRACTS 75 76 85 3 86 IN SEC 35 a) Street Address: 7350 Dai Road,Zephyrhills,FL 3354 2. General description of improvements 3, Owner Int'armation ' a) Name and add�a5s: ZephYrhills Health 8 Rehab Center,Inc.,7350 Dafry Road,Zephyrhills,FL 33540 b} Name and address of fee simple titleholder(if othcr than owner) N/A � � c} Mterest in property NIA f4. Contractor Information � �i a) Name and address: 'S�p nn P.v�.S .tnd�S� �1.lUj �s.a'�e.,M.n ��Q 'Tf�m�R- FL .33���/ b) Telephone No.: �j����,'�r L��G� Fa o.(Opt.) $'13• 4 D--�"�'raT 5. Surety Information —" 8� Name and address: N!A PqULA S.0'NEIL,Ph.D.PA5C0 CLERK $ COMPTROLL�R b) Amount of Bond:NIA 01/02/14 c) 7'e(ephane No.: NIA pR BK '�2Ag�� 1 of 1 G. Lcndcr �� �� 3364 a) Name and address: N/A 7. Identity of person within tfie State of Ftorida designated by owner upon whom aotices or other documcnts may be scrvcd; a) Name and address: Kevan Evans.VP.Adventtst Care Centers,602 Courtland St.,Ste 200,Orlando,FL 32804 b) Telephone No.: 407-975-3000 Fax No.(Opt.) 8. In addition to hirnself,owner designates the following person to receive a copy of the Lienor's Notice as provided in Scction 713.]3(1)(b),FloRda Statute,c: a) Name and address: Kevan Evans,VP,Adventfst Care Centers,602 Courtland St.,Ste 200,Orlando,FL 32804 b) Telephone No.: 407-975-3000 � Fax No.(Opt.) _ 9. Expiration dale of Notice of Commencement(thC expiration date is one year from the date of recording unless a different date is specified}: 01f0212015 III -- — � WARNiNG TO OWNER:ANY PAYMENTS MADE BX THE OWNER AFTER THE EXPIRATION OF 7'HE NOTICF.OF I COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713,PART I,SECTlON 713.13, i F�,ORIDA STATUTES AND CAN RESULT IN YOUR PAYING TWICE FOR IPROVEMENTS TD YOUR PROPERTY.A 1VOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE REFORE THF,FTRST INSPECTION.IF YOU INTEND TO OB'I'AiIV FINANCING,CONSUI.,T YOUR LEIVD�R OR AN ATTORNF,Y BEFORF, COMMENCING WORK OR RECORDING YOU NOTICE OMMENC NT. sTA'CE o ' JEANNIE GALLOWAY i COUN'TY �.t: Not�ry PuDlie•Staro ot Florida Sign re OF Owner or Owner s Authorized Uificer/DircctodPartncr/Managcr •i My Comm.Expires Jul 21,2015 � Commission#EE 114788 April Doherty,Administrator �����'�,'BondeA TAtouph Nationai Notup b=n. Print Name 'ihe k>regoing instrument was acknowledged before me this o� day of �G �- ___ ,20 I`7,by. /���. �s�'/"' as e of euthori �— �..•----��--- _` (typ ry,e.g.officer,trustce,attorncy in fact)for _ (nartee of party on bchalf of whom insttvment was •utu!). Pcrsonally Known �/OR Produccd Identifecation` Notary Signature _ "�ype of[dcntiRcation Produced /�k7�.�/� Name(print) � rilv► C C�'� �� Vcrification pursuant to Scction 92.525,Florida Statutes.Under penalties of cry'ury,f declare that I have rcad the fr�regoing anJ that thc facts statcd in it are true to the best of my knowladge and belief. � FORMS/NCX:n[dI00' . ___"'_`_ � N�tunl Pmen. STATE OF FLORIDA,COUNTY OF PASCO ` THIS IS TO CERTIFY THAT THE FOREGOING IS A .��I►� � w �'I,Q TRUE AND CORRECT COPY OF THE DOCUMENT �� ON FILE OR OF PUBL{C RECORD IN THIS OFFICE ,� WITNESS MY HAND AND OFFICIAL SEAL THIS ,�t . . ��DAY OF r� 2�1 y I�•r��,�r-,<<,' . # PAULA .,_O'N�1 , K& MPTROLLER * � �'�'`�, � - --- - _ * � . # BY <-�--�_�_DEPUTY CLERK • 188� * _.____..___. � • ���'^��.r��.oa'�Op` �E�HYRE�ILL� F[RE aEP/�Rfi�Ef�T 6907 Dairy Road, Zephyrhills, FL 33542 FIRE SERVICE USER FEES Occupancy No.: Pian No.: - Contractor: 8usiness Name: .� Billing Address: Business Address: Business Phone No.: Bitling Phone No.: Business Fax No.: Billing Fax No.: Contact: Contact: PLAN REVIEW FEES INSPECTION FEES PERMIT FEE FALSE ALARM FEE Site Plan NIC Annual N/C Sprinkler $50 1st Alarm N/C Iti-Family/Commercial .06 sf 1 st Re-inspection WC Standpipes S50 2nd Alarm N!C Minimum Charge$25.00 2nd Re-inspection 5100 Fire Pump $50 3rd Alartn N/C � Plan Revisions DBL 3rcJ Re-inspection 5250 Hoods �50 4th/Uarm 5100 4th Re-Inspection 5500 Fire Alarm $50 5th Alann $150 SPRINKIER SYSTEMS (Business dosed until LP Gas S50 6th Alam► S200 0-25 Heads �50 violatio�s corrected) Natural Gas $50 NON COMPLtANCE a150 26 plus Heads $100 SPRINKLER SYSTEMS Fuel Tanks- Per�ank $50 STANDPIPE SYSTEM Hydro Undergrounds a45 Sparklers 5100 � Per Riser 350 HydrostaUc Test $65 per sy�em Fire Works 3500 FIRE PUMP Acceptance Test a45 per system Camp Fire S25 � Per Pump a100 Hydrant Flow $75 Controlled Bum $100 FIRE ALARM SYSTEM Hood/Duct �50 �0-25 Devices $50 FIRE ALARM SYSTEM Place of Assembly $50 amuai 26 plus Devices 5100 System Acceptance $50 Fire ProtecGo� $25 SUPPRESSION SYSTEMS Recall Acceptance S50 Flammable Application S50 �nnuai Wet $50 OTHER Waste Tire Storage a50 nnn� Dry S50 Rre WaIVSmoke wau �15 Perwau Generator<KW 5100 CO2 $50 LP Gas S25 Per�k Generator>30 KW 150 Other $50 Natural Gas $25 �sys�em Bio-Hazard Waste 5100 �nnuai KlTCHEN EXHAUST Fumigation Tenting S50 �Hood/Ducts S50 Tent 10k10'or greater $15 per tent Torch PoUApplied a50 OTHER Fire Pump S45 Haz.Materiafs 5100 �nrn,ai BLp Installation per tank a50 Fire Suppression $30 Fuel Tank Installation S50 System Acceptance (Per Tank) �50 E�aust HoodlDuct S30 �Natural Gas Insallation �50 Re-inspection DBL (Per System) (other than annual) � Spray Booth 350 � InspecNon scheduled DBL a and canoelled less than 24 hours Construction Insp. WC Emergency Vehicle A� $50 FALSE ALARM __ _ --PLiWS TtjT�1t�--1irSPEt`TiBN-�t�i'AL� _ PfRMii'-i'O��1t� _-----ifl�f�t�_ ___ GRAND TOTAL Comments• Date: r� � � _ Inspector: �"'�/��0-QQ nin Submittals For: Fire Alarm System Upgrade Zephyrhills Healthcare & Rehab 7350 Dairy Rd Tampa, F133541 Cataloq Cut Sheets & Calculations ■ Date Submitted: December 10, 2013 Svstem Installed bv: Siemens Fire Safety 8403 Benjamin Rd. Suite F Tampa, FL 33634 Ph (813) 261-8700 Fax (813) 890-8055 SI EM ENS Building Technologies 8403 Benjamin Rd. Suite F Tampa, FL 33634 Phone (813)261-8700 Fax (813)890-8055 TABLE OF CONTENTS PREPARED FOR: PREPARED BY: Zephyrhills SIEMENS Building Technologies 7356 Dairy Rd 8403 Benjamin Rd., Suite F Tampa , Florida 33541 Tampa, FL 33634 FIRE ALARM SYSTEM TABLE OF CONTENTS INDEX BY MODEL NUMBER MODEL CATALOG NUMBER DESCRIPTION NUMBER MXL LINE CARD FireFinde XLS 6354 FDOT PhotoElectric Detector 6150 SSD System Status Displayr 6326 Pad-4 Power Supply 3363 CH Series Chime/strobe 2572 Z Series Strobes 2584 Anixter Various Wire Types SI EM ENS �ata sheet Fire Safety&Security Products FireFinder� XLS MXL Line Card Model MLC ARCHITECT AND ENGINEER SPECIFICATIONS � ,� • Alarm,Trouble,Supervisory,Security and Status reporting � • Two(2)intelligent analog device circuits ' • 60intelligentdevicespercircuit : • Accepts remote conventional-zone modules ��'" • Degrade mode F�.� • Supports audible bases • On-board microprocessor �� • On-Board,ground-fault detection , ' • Programmable Input/Output module f s • Short-circuit isolation with Model LIM-1 r, t� • Remote smoke-detector-sensitivity adjustor ' ` ._... ' • Independent control of detector relays �,,, � � • Up to 60 relays per dreuit �.�� � ��{�, • Intelligent contact monitoring devices Esrdsv�v7 ; tF�ontr�ew> • 'Class B'(Style 4)or'Class A'(Style 6)wiring position • �UL 864 9�'Edition Listed; • SupportsT-Tapwiringfor'dassB'circuits CSFMApproved Product Overview Specifications — (continued) The MXL Line Card (Model MLC)is an optional card Sensitivity of certain smoke detectors can be queried and for the FireFinder XLS fire alarm control panel (FACP) adjusted at the FireFinder XLS control panel. Further, that supplies two(2) intelligent analog circuits, sensitivity 1 obscuration,as well— as other device utilizing the Model'I'-series;Model'ID'-series; Model information—can be displayed and printed at the 'IL'-series or Model'FP'-series type intelligent devices. FireFinder XLS. Model MLC occupies two(2)addresses on the HNET Model MLC supports the use of relay bases and audible bases network,and—through the use of a unique (independently controllable). To provide analog-loop,short- communications protocol—devices connected circuit isolation,the Model LIM-1 module can be used to to the Model MLC circuits are dynamically prevent a single short circuit from interrupting loop-device supervised by FireFinder XLS. communication. Smoke detectors are monitored for sensitivity 1 Each Model MLC circuit can be wired in either a'Class B' obscuration,and notification is given when the (Style 4)or'Class A'(Style 6)configuration. When using sensitivity 1 obscuration is outside normal parameters. the(Style 4) method,T-Tap wiring is permitted with no loss Specifications of supervision. Each of the Model MLC circuits supports the use Model MLC has an on-board microprocessor,which provides of up to 60 Alorm; Trouble;security;status,and the ability to function in a degrade mode and initiate alarm supervisory-type devices. Further, remote conditions,even if the FireFinder XLS main central- conventional initiating-device zone modules(Model processing unit(CPU)fails. Model MLC plugs into one(1) CZM-1 B6); intelligent monitoring devices(Model TRI), card slot in the Model CC-5 or Model CC-2 card cage. and intelligent control points(Model ICP-66)are also supported by Model MLC circuits. MXL Line Card for FireFinder XLS 6354 SIEMENS Industry, Inc. Building Technologies Division Temperature and Humidity Range Related Documentation Model MLC is�UL 864 9th Edition Listed for indoor '" ` ` ' "�, z�����'� 1 � �"��� dry locations within a temperature range of FireFinder XLS Overview 6300 120+1-3°F(49+1-2°C)to 32+1-3°F(0+1-2°C)and a relative humidity of 93+1-2%at a temperature of 90+1-3°F(32+/-2�c�. Details for Ordering r �:� ;��� �,,,<: ,��s � w � � e,. :��4���� }���� �� ,, �' ,rr�$ '�� MLC 554431-64-A1 MXL Addressable Line Card for FireFinder XLS Notice: This marketing data sheet is not intended to be used for system design or installation purposes. For the most up-to-date information,refer to each producCs installation instructions. Fire Safety Fire Safety 8 Fernwood Road 2 Kenview Boulevard SIEMENS Industry, If1C. Florham Park,NJ 07932 Brempton,Orrtario pugust 2012 Building Technologies Division Tel:(973)593-2600 (su•FS� L6T 5E4/Canada s�p<n�a�:n���a.«a:i�z FAX:(908)547-6877 Printed in U.S.A. Tel:(905)799-9937 �ae�.z> URL:www.usa.5iemens.com/Fire FAX:(905)799-9858 SIEMENS �ata sheet Fire Safety&Security Products I ntel I i ent Detection Devices g Multi-Criteria Fire Detector Model FDOT421 ARCHITECT AND ENGINEER SPECIFICATIONS • Multi-criteria addressable fire detector that incorporates photoelectric and thermal sensors • Utilizes advanced signal processing with proven detection algorithms • Differentiates between deceptive phenomena and an actual fire(nuisance-alarm avoidance) • Compatible with Model DPU(device programmer/loop tester) • Responds to both flaming and smoldering-fire signatures ��` ,,� y • Field selectable application profiles � • Superior EMI immunity �h' ' � • Remote sensitivity-measurement capability � • Tri-color detector status LED with 360°viewing "` "� • Each detector is self-testing: ��� • complete diagnostics performed every 10 seconds �/ • self monitored for sensitivity within 6�UL Listed limits ,.�, ~ ��• Polarity insensitive utilizing SureWireT""technology • Compatible with DB-11 series mounting bases - • Compatible with FireFinderT""XLS control panels(with Siemens Model'H'-series devices on the same loop) • RoHS compliant • Listed and approved as heat detector • Automatic environment compensation • Rate-of-Rise Detection: 15°F/min.(8.3°C/min), • AUL Listed and�ULC Pending; and fixed 735°F(57°C) CSFM Approved Product Overview The Model FDOT421 photoelectric detector Model FDOT421 is compatible with the Siemens Fire incorporates both optical and thermal sensors,and Safety field-device programmer 1 test unit(Model DPU), uses advanced software algorithms to combine the which is a compact,portable,menu-driven accessory for signals into a neural network to create an intelligent electronically programming and testing detectors,easily multi-criteria detector. The encompassing result is a and reliably. detector that provides enhanced detection to a wide Model DPU eliminates the need for cumbersome, range of products of combustion,while offering unreliable mechanical programming methods,such as superior rejection to nuisance-alarm sources. dials or switches,and reduces installation and service Model FDOT421 utilizes advanced multi-criteria costs by electronically programming and testing the detection technology that allows the detector to detector prior to installation. distinguish non-threatening deceptive phenomena Model FDOT421 is a plug-in,addressable,two-wire and (i.e.—cigarette smoke)while optimizing detection for multi-criteria detector(with both photoelectricand thermal the area. Model FDOT421 uses state-of-the-art inputs)that is compatible with FYreFSnderXLS control microprocessor circuitry with error check,detector panels. self-diagnostics and supervision programs. Multi-Criteria Fire Detector 6150 SIEMENS Industry, Inc. Building Technologies Division Product Overview— (continued) Profile overview Each detector consists of a dust-resistant photoelectric Model FDOT421 provides two(2)different alarm sources chamber;a solid state,non-mechanical thermal sensor,and that can be selected individually(ON or OF�by the control microprocessor-based electronics with a low-profile plastic panel. housing. Every Model FDOT421 fire detector is shipped with Alarm Source 1 (Neural Network)—Combines smoke—heat a protective dust cover: with the following selectable profiles: • Sensitive •Standard • Robust 1 Sensitive: This parameter set is practically suitable for areas where few misleading sources of false alarm are present,and is appropriate where priority is given to � detecting open fires as soon as possible(e.g.—typical ly a Z clean application with controlled environmental ��r�oa�Fnar+��a�c� conditions.) z)nuse aoo�er �������> Robust:This parameter set offers improved resistance to false alarms in areas where misleading sources, Operation such as cigarette smoke or exhaust fumes, may cause Model FDOT421 utilizes an infrared lightemitting diode a nuisance alarm. (IRLED),and infrared light-sensing photodiode. Under Standard•This parameter set is practically apt for normal conditions,lighttransmitted bythe LED is directed normal office, hotel lobby type applications and is the away from the photodiode and scattered through the smoke default setti ng. chamber in a controlled pattern. The smoke chamber is designed to manage light dissipation Alarm source 2(Thermistor)—Heat only,provides the and extraneous reflections from dust particles or other non- following: •Static 1 fixed at 135°F(57°C),default setting smoke,airborne contaminants in such a way as to maintain . Rate-of-Rise Detection: 15°F I min. (8.3°C 1 min) stable,consistent detector operation. When smoke enters the detector chamber,light emitted from the IRLED is If the detector is not programmed,Model FDOT421 will scattered by the smoke particles,and is received by the default to a'standard'profile setting,which allows operation photodiode. for a normal office-type environment. Model FDOT421 also utilizes a modern,accurate and shock- Model FDOT421 contains a tri-color LED indicator,capable of resistant thermistor to sense temperature changes. flashing any one(1)of three(3)distinct colors: Green, 'r'� ��:�.,or Red. During each flash interval,the The signal processing with detection algorithms allows the microprocessor-based detector monitors the following: detector to first gather smoke and thermat data,and then .Smoke in its sensing chamber analyze this information in the detector's'neural network.' . Smoke sensitivity is within the range indicated By comparing data received with the common on the nameplate label characteristics of fires orfire signatures,Model FDOT421 can . Internal sensors and electronics compare these signals to those of deceptive phenomena that cause other detectors to false alarm. Based on the results of the monitoring,the LED indicator flashes the following: 3 ��85�1 Flash Car�iti�c� t� 1 N���` �O�Of 5�L1f�i i , ��%xs��, ; Normal supervisory operation. p � ' � Smoke sensitivity is within 7 0 � ��,,,� � .,�,`��.�,�wa rated limits. Detector is in trouble and Yellow: needs replacement. 4 � �''�'""�' � ��"� Alarm condition. 1 2 OgGnl LrartamieEer � �"�'iO�"'�` No Flash: Detector is not powered. -- Each Model FDOT421 detector provides three(3)pre- *LED can be turned OFF. programmed parameter sets that can be selected by the fire Please follow the corresponding description of the panel used. alarm control panel. SIEMENS Industry, Inc. Building Technologies Division Installation All Model FDOT421 detectors use a surface-mounting Model FDOT421 fire detectors can be applied within base, Model DB-11 or Model DB-11 E, which mounts the maximum 30-feet center spacing(900 sq.ft. on a 4-inch octagonal, square or single gang areas,)as referenced in NFPA 72. This application electrical box. The base utilizes screw-clamp contacts guideline is based on ideal conditions,specifically, for electrical connections and self-wiping contacts for smooth ceiling surfaces, minimal air movement,and increased reliability. no physical obstructions between potential fire The Model DB-11 base can be used with the optional sources and the actual detector. Do not mount Model LK-11 detector locking kit,which contains 50 detectors in close proximity to ventilation or heating detector locks and an installation tool to prevent and air conditioning outlets. Exposed joints or unauthorized removal of the detector head. Model beamed ceilings may also affect safe spacing DB-11 has decorative plugs to cover the outer limitations for detectors. mounting screw holes. Should questions arise regarding detector placement, Model FDOT421 may be installed on the same observe NFPA 72 guidelines. Good fire-protection initiating circuit with the Siemens Model'H'-series system engineering and common sense dictate how detectors (Models HFP-11 and HFPT-11); Model and when fire detectors are installed and used. 'HMS'-series manual stations; Model'HTRI'-series Contactyour local Siemens Industry—Fire Safety interfaces; Model HCP output-control devices, or distributor or sales office whenever you need Model'HZM'-series of addressable, conventional assistance applying Model FDOT421 in unusual zone modules for FireFinder XLS control panels. applications. Be sure to follow NFPA guidelines and �UL Listed 1�ULC Pending installation instructions— All Model FDOT421 detectors are approved for included with every Siemens—Fire Safety detector— operation within the�UL-specified temperature and local codes as for all fire protection equipment. range of 32 to 100°F(0 to 38°C). Model DPU Technical Data The Device Program 1 Test Unit accessory is used to Operating program and verify the address of the detector. The Temperatures: +32°F (0°C) to 100°F (38°C) technician selects the accessory's program mode, Relative Humidity: 0-95°�; non-condensing and enters the desired address. Model DPU automatically sets and verifies the address and tests Air Velocity: 0-4,000 ft. 1 min (0-20m I sec) the detector. Model DPU operates on AC power or rechargeable Air Pressure: No effect batteries, providing flexibility and convenience in Maximum Spacing: 30-foot centers (900 sq. ft.), programmer and testing equipment from practically per NFPA 72 and�l.1LC-5524 any location. pending When in the test mode, Model DPU will perform a Input Voltage Range: 16VDC— 30VDC series of diagnostic tests without altering the address or other stored data,allowing technicians to Alarm Current: 410uA, max. determine if the detector is operating properly. Standby Current: 250uA, max. Application Data (average> Installation of the Model FDOT421 series of fire Detector Sensitivity Range: aUL: 1.10°�to 2.62%1 ft. detectors requires a two-wire circuit. In many retrofit �ULC: 1.44 to 3.06�01 ft. cases,existing wiring may be used. T-tapping'is Pending permitted only for Style 4(Class B)wiring. Model FDOT421 is polarity insensitive,which can greatly Thermal Rating: reduce installation and debugging time. • Fixed-temperature set point: 135°F(57°C) ■ Rate-of-Rise Detection: 15°F/min. (8.3°C/min) Detector Weight: 0.317 Ibs. (0.144 kg.) Mechanical Protection Guard: 4UL Listed I�ULC Pending with STI Guard Model STI-9604 SIEMENS Industry, Inc. Building Technologies Division Mounting Diagram Details for Ordering Dimensions � KK� ``'` "` y�+ ��#v, fr�$L{ �i ¢��N 4_73" [10_3 cm_]-� N�� ���y� FDOT421 554320-F6-A1 Addressable Mu�ti-Criteria Fire Detector � � � DB-11 500-094151 Detector Mounting Base for Series 11 t.93•' a.s cw.: DB-11 E 500-094151 E Detector Base{small} ,.aE�� RL-HC 500-033230 Remote Alarm Indicator:4"octagon- 3_TCr.? � box mount, red Rl-HW 500-033310 Remote Alarm Indicator:single-gang box mount, red LK-11 500-695350 Base Locking Kit for Series 11 Detectors In Canada, order: � 4� �, �^x , �� ����. �±�, 9* .��"�i�'W., DB-11 C 500-095687 Detector Mounting Base for Series 11 Detectors(�ULC pending) Notice: This marketing data sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product's installation instructions. Fire Safery Fire Safety 8 Femwood Road 2 Kenview Boulevard SIEMENS Industry, It1C. Florham Park,NJ 07932 Brampton,Ontario pugust 2011 Building Technologies Division Tel:(973)593-2600 (SiHFS) L6T 5E4/Canada Supersedessheetdated 7/11 FAX:(908)547-6877 Printed in U.S.A. Tel:(905)799-9937 (Rev.2) URL:www.SBT.Siemens.com/F15 FAX:(905)799-9858 S 1 E M E N S F�re Sa��, SSD S stem Status Displa y y For the FireFinder XLS System ENGINEER AND ARCHITECT SPECIFICATIONS • 4 x 40 Backlit LCD display • Event and Audible status LEDs � Scroll buttons to view additional events • Localsounder • Supports Style 4 or Style 7 wiring • Built-in transient protection • Provided in its own enclosure • Downloadable firmware • � U L, U LC Listed Introduction The Model SSD System Status Display is a remote A local sounder is included with the SSD that operates LED/LCD display that shows the local status of a when any events are displayed on the system. The FireFinder XLS system. An LED illuminates when sounder can be optionally disabled through software alarm, supervisory, trouble, and security events occur or hardware programming. When an event is present, on the system. A four-line LCD will give details of the pressing any operator buttons will silence the local event in alphanumeric form. The display can be sounder. toggled to display additional events. The SSD has two display control buttons that are used to display the next or the previous event information Description in the sequence, and a local sounder silence button. The SSD has separate LEDs for alarm, supervisory, Programming for the SSD display is done with the trouble, and security events on the system. Each LED Zeus programming tool. will flash when unacknowledged events of that type The SSD is remotely connected to the H-Net communi- are present on the system. The LED will change to cation bus from any NIC-C interface in a FireFinder XLS steady upon acknowledgment of the event. Also, system enclosure using Style 4 or Style 7 wiring. there are two LEDs that indicate the state of audible 24VDC is required to run the SSD, and it can be circuits on the system; one LED to indicate that the provided from a Model PSC-12 Power Supply or circuits are active, and one to indicate that the circuits PSX-12 Power Supply Extender in the FireFinder XLS have been silenced. system enclosure. Power from other UL Listed 24VDC The LCD display on the SSD has four lines of forty power sources is also acceptable. The SSD has screw characters each. When the FireFinder XLS system terminals capable of supporting 12 to 22 gage wires. is in its normal supervisory state with no events The H-Net communication from the FireFinder XLS present, the display will annunciate the system ID system can be terminated on the SSD, or may pass information along with the date and time. When an through for communication with other modules. event occurs on the system, the LCD display will Diagnostic LEDs on the SSD indicate power and show the event type and address, the time of the communication status. event, the custom message for that address, the The SSD can be mounted in a 2-gang electrical box usage of the device, and whether the event is acknowl- or a 4-inch square electrical box. No flush trim kit is edged or not. Additionally, the display will show the re uired. The unit is a total number of all types of events present on the q pproximately 10-1/2" wide, 6-1/8" system. The display has a backlight feature that high, and 1-1/2" deep. operates upon receiving any event information or when any operator buttons are pressed. CATALOG N U M B E R �+��� V�7 Ordering Information Mod�l Pan Nambsr Ds:criptio� N�wber SSD System Status Oisplay 50D-034170 Electrical Ratings 24V Back Plane Current: 0 ScrewTerminal 24V Current: 200mA 6.2V Back Plane Current: 0 24V Standby Current: 200mA NOTICl:The use of other than Fire Safety detectors and bases with Fire Safety equipment will be considered a misapplication of Fire Safery equipment and as such void all wartanties either e�ressed or implied with regard to loss,damage,liabilities and/or service problems. Fire Safety Fire Safety 8 Fernwood Road 2 Kenview Boulevard Florham Park, NJ 07932 1/03 Brampton, Ontario Siemens Buildin Technolo I@S Tel: (973) 5932600 5M Canada L6T 5E4 9 9 FAX: (973)5936670 SFS-IG Tel: (905)799-9937 January 2008 Fire Safety Website: www.sbt.siemens.com/fis Printed in U.S.A. FAX: (905)7939858 SUPBf9BGB99hBBLC31BE1ZY11 51 EM ENS �ata sheet Fire Safety&Security Products FACP Accessories PAD-4 Distributed Power Supply Unit Notification Appliance Circuit Extender Models PAD-4-ENCL, PAD-4-MB (with FP2011-U1, FP2012-U1 power supplies) ARCHITECT AND ENGINEER SPECIFICATIONS • Four(4)'Class B',power-limited notification appliance circuits(NACs) � • 'Class A',field-selectable wiring • Each unit can support an optional module(Model PAD-4{LSA)that converts two(2)built-in'Class A'NACs into four(4)'Class A'NACs 'CI855 A' • Up to 3 Amps of auxiliary-power output Adapter Card • Optional built-in strobe synchronization [ModeIPAD4CLSA] • Supports coded audible signals,including Temporal 3,Temporal 4 patterns • Battery supervision and control • 'Form C'general Trouble/AC Fail monitoring contact • Power supplies support NAC power Main Board Unit Enclosure • Up to 6A used with Model FP2011-U1 [Model PAD-4-MB] [Model PAD-4-ENCL] ■ U to 9A used with Model FP2012-U 1 • 24VDC output voltage • Multi-module mounting in System 3TM'enclosures • Ground-fault detection • Multiple modules share battery set • Advanced microprocessor control • ADA Compliant • Uses Flash memory-based system firmware • mUL 864 9th Edition Listed; • Optional system-diagnostic and firmware-upgrade tool �IJL 1481 Listed(for power supplies) Product Overview Used with Siemens—Fire Safety fire alarm control The PAD-4 unit provides consistent 24VDC output panels(FACPs),the Distributed Power Supply PAD-4 voltage to each NAC—independent of voltage Unit is a NAC expander with a built-in,auxiliary- fluctuations on the primary or secondary power power output. Each PAD-4 unit distributes source. As a result,a larger voltage drop and a additional power in buildings for audible and visual greater wire length for each NAC are supported by indicators that conform to the Americans with each PAD-4. Disabilities Act(ADA). PAD-4 also has the following features: Specifications • NACs This version of the Siemens Distributed Power Supply • Signal-input circuits Unit can be configured in the following manner that • Battery-charging circuit makes the outputs easily programmable: • Trouble relays for remote monitoring • Diagnostic light-emitting diodes(LEDs) • 'STEADY'outputs • Synchronized strobe outputs • Alternating Current(AC)power connection . American National Standards Institute(ANSn Temporal 3 The Siemens NACs,which connect with alarm • ANSi Temporal 4[for carbon monoxide(CO)alarm signal] signaling devices, have been designed to provide There are also two(2)inputs used to control the the highest level of reliability and performance. activation of the four(4)outputs. Programming can Signal coding on the circuits is accomplished be set so one(1) input will silence the audible signal through integrated circuits(rather than relays), on Siemens Models'AS'-series,'NS'-series,or'ZH'- which eliminates mechanical wear on the output series horn and horn-strobes while the strobes circuits. remain active. Distributed Power Supply—NAC Extender(Model PAD-4 series) 3363 SIEMENS Industry,Inc. Building Technologies Division Specifications — (continued) Operation of each PAD-4 unit is controlled by Each unit is packaged in its own sheet-metal firmware stored in Flash memory on the main board, enclosure with sufficient space to house up to 7AH as well as the storage of a 10-event log,which can battery sets.The enclosure(Model PAD-4-ENCL) is be viewed via Model PAD-4-FDT. In the event that available in red. an upgrade to the system firmware is required,the The battery charger used in each unit can energize firmware can be transferred to the system without batteries of up to 18AH. Though,when battery sets the replacement of firmware chips. greater than 7AH are required,the battery set must An optional firmware-download software tool, be housed in a System 3 enclosure or a separate Model PAD-4-FDT,can be used for system diagnostic m�UL Listed battery enclosure. testing of the following: System 3 enclosures may also be used to house • Primary-powervoltage readouts multiple Model PAD-4 units in a single enclosure,via • Current draw for power charger • Configuration switch settings the Model S3AP Adapter Plate.Two(2)units are ■ Firmware version capable of sharing the same battery set when • Batteryvoltage mounted in the same enclosure. Model S3AP can When the tool is in communication with Model PAD- also be used to mount the PAD-4 main board and 4-MB,the'Test Mode'LED is illuminated. Model 170-Watt power supply(Model FP2011-U1)into a PAD-4-LUA is a USB serial port adapter that is PAD-3 enclosure. required for tool-kit operation. Each Model PAD-4-series unit complies with seismic Each NAC extender supervises a variety of functions certification, pursuant to ASC/SEi 7-05,Section including: 13.2.2,when used with the PAD-4 battery bracket • �ow Ac power (Model PAD4-BATT-BRKT). • Battery-voltage level • Earth ground-fault conditions All power can be directed to two(2)'Class A'or four Configuration Options (4)'Class B'power-limited NACs. Each NAC supports 0 � .� �� � up to 3 Amps per circuit. Either one(1)or two(2) � ����'� ' inputs can control four(4)outputs,which are � In �c i All outputs 'Class B•������ts compatible with all Siemens—Fire Safety 24VDC 2 Input 1 All outputs 'Class B•��r���u alarm signaling devices. In �t z• Silences horns on Output 1 — Input 1 Outputs 1 and 2 'Class B'circuits In cases where'Class A'circuits are used,an optional 3 In �t 2 Outputs 3 and 4 'Class B���r���cs Model PAD-4-CLSA module can be added, providing 4 Input 1 o�tP�t i 'Class B���r���ts two(2)additional'Class A'outputs to each PAD-4 I� �t z o�tPuu z,3 and 4 'Class B�c�rc��ts U Il It. 'Class A' 5 Input 1 Outputs 1 through 4 �ircuit pairs Each NAC extender is also capable of operating other parts of a Siemens fire alarm system,such as door Input 1 Outputs 1 through 4 "Class A• holders,via 3 Amps @ 24VDC max of power-limited 6 circuit pairs auxiliary output. When the output activated,the In �t z• Silences horns on Outputl Input 1 Outputs 1 and 2 "Class A' total power available cannot exceed 6 Amps when � circuit pairs used with Models FP2011-U1 or 9 Amps when used 'Class A• wlth FP2012-U1. Input 2 Outputs 3 and 4 p rs circuit ai Trouble conditions are monitored through each Input 1 Outputs 1 and 2 �Class A• 8 circuit pairs unit's two(2) inputs. In addition,one(1)'Form C' Ir, �cz Outputs3 and4 'ClassB���r���u Trouble contact is provided for monitoring each unit *denotes when used with Siemens Model:45;'NS'or7H'-series that is connected through the input of a Siemens horn/strobedevices FACP. Therefore,the user has the option of connecting a PAD-4 NAC extender unit into a NAC of a Siemens FACP,or the unit may be monitored with a Model TRI-series monitoring module on a Siemens intelligent fire system. A separate'Form C'Trouble contact is used exclusively with each NAC extender to indicate AC Fail Trouble events on the NAC extender. SIEMENS Industry, Inc. Building Technologies Division Indicator Lights Temperature and Humidity Range AC Power ON• Each PAD-4 Distributed Power Supply Unit is oUL 864 aux/P5: 9th Edition Listed for indoor dry locations within a Ground Fault: temperature range of 120+1-3°F(49+1-2°C)to out ut� 'rrouble: � 32+1-3°F(0+1-2°C)and a relative humidity of 93+/-2% out utZ trouble: �, at a temperature of 90+1-3°F(32+1-2°C). Out ut 3 Trouble: : o�t ut4Trouble: ;::;.,��,,., Details for Ordering � '���. Test Mode: �.,� ri�"'� � ��l�> .. �, . , ., _... . PAD-4ENCL 500-050081 PAD-unit enclosure PAD-4-MB 500-650217 PAD-unit main board FP2017-U1 500-450222 170-Watt ower su I Technical Data FP2012-U1 554400-Z60-A1 300-Watt owersu I �' 2.OA @ 30VDC,max. [MSt:et�.� —System Kits— 2.OA @ 30VDC max. '� ��*� +'' [nslstlwl � �` � s`.� ,t ;� ��,c... �, . . "'"�� '�:" "'��a• *� 3.OA er circuit,max. � �� � � r s Complete 6A PAD-4 kit wlth: .�,' k` " � e�,max.{via Modd Fvzoit-ut} -One(1)Unit Enclosure,PAD-4-ENCL --- ----------- PAD4-6A 554339-A1-A1 � s�,max.{v�a Mod�i Frzata-ut} —One(1)Main Board,PAD-4-MB —One(1)170W powersupply,FP2011-U7 `� � ,». ,�a'�°! '4 32°—120°F Complate 6A PAD-4 kit wlth: ��'+� ' �i (0°—49°C) —One(1)Unit Enclosure,PAD-4-ENCL �sr�4. Up to 93%@ 86°F(30°C); PAD4-6A-CLSA 554339-A2-A1 —One(1)Main Board,PAD-4-MB �"t'� ��,. —One(1)170W powersupply,FP2011-U1 ,_• non-condensin —one�i�'Class A'Adapter Card,PAD-4-CLSA One(1)circuit @ 3A max. Complete 9A PAD-4 kit w)th: '{"� 18AH PAD4-9A 554339-A3-A7 -One(1)Unit Enclosure,PAD-4-ENCL �' Two(2)'Class B'supervised —One(1)Main Board,PAD-4-MB ° `,� _ —One(1)300W power supply,FP2012-U1 � or �;,� � +' Two(2)'Class A'su ervised Complete 9A PAD-4 kit wlth: -One(1)Unit Enclosure,PAD-4-ENCL �• �x ` 7.OmA,max. PAD4-9A-CLSA 554339-A4-A1 -One(1)Main Board,PAD-4-MB 16—33VDC 1 VFW —One(1)300W power supply,FP2012-U1 — One(1)'ClassA'AdapterCard,PAD-0-CLSA Indoor,dry ':'x', ;j, 7 � ': oSupervised,power-limited —OPt1011a1ACC@SSO�I@S— x � 0 1.OmAstandby "� �;�;y��� � ,, -�:�. �°�� � � � current,max. �' � �`� � � ' �`'��"° �,, �,. ��� � �.�� � �,����,`i �' o Four(4)circuits PAD4-BATT-BRKT 554430-64-A1 Battery bracket for NAC expander ,� ` ! ��.� `�'`� 0 2K ohms(+),SK ohms(-) pAD-4-LUA 554389-C1-A1 PAD-4 Laptop-Upload Adapter � 1 ��� -; 24VDC @ 6 Amps PAD-4-CLSA 500-850254 'Class A'Adapter Card (with Model FP2011-U1); 4 � � �� � w�' �� ---------------- S3AP 500-650257 PAD-4 NAC expander adapter plate " .P �s �;�, � 24VDC @ 9 Amps (for use with PAD-3 and S stem 3 encbsures) � ��z=,��, �.w�` ^ uv:n ' "' ` (with Model FP2012-U1) ;F a � '�` o Two(2)'Class A'; � ����.:r'��' r —Up to four(4)'Class A' �'� .� �"� � - �' :; .`-—(via bfodel PAD-4-CLSA�----- "`` ' o Four(4)'Class B'; �. � . ' -— -------------------------- k � :. "' a:� x, o One(1)Class A, ,�*�, , �a�°=.,a� Two(2)Class B; ",�,= z�""`' ��.}%;y ` ' 13.5"-x-18J5"-x-3.25„ � (343 cm.-x-47.6 cm.-x-8.3 cm.) 1;4�. Red SIEMENS Industry, Inc. Building Technologies Division Notice: This marketing data sheet is not intended to be used for system design or installation purposes. For the most up-to-date information,refer to each product's installation instructions. Fire Safety Fire Safety 8 Fernwood Road 2 Kenview Boulevard SIEMENS Industry, If1C. Florham Park,NJ 07932 Brampton,Ontario Building Technologies Division Tel:(973)593-2600 (sll-FS� L6T SE4/Canada A�Bust 2015 FAX: 908 547-6877 Printed in U.S.A. Tel: 905 799-9937 s��rs�a�,n��ea.e<a si�a ( ) ( ) iR��.,i URL:www.usa.Siemens.com/Fire FAX:(905)79&9858 SI EM ENS Catalog Sheet Fire Safety&Security Products `08 Series Notification Appliances CH — Chimes and Chime Strobes � � ' � ` , ��c��r � "T rr .?:�'�f-�si ' '"�"+'i�?'~':*�� .. .. .- .-• . '�-.-.�_.-ti`"-'� �' 1 R E . . CH-CW CH-R CH-MC-R GH-MGCW Chime Chime Chime Strobe Chime Strobe Product Overview — Low current draw with temperature compensation to reduce power consumption and wiring costs — Wall-mount models are available with field selectable Candela settings of 1 513 017 511 1 0cd — Ceiling-mount models are available with field selectable candela settings of 15130l75195cd or 115I177cd — Strobes produce one(1)flash per second over the regulated input voltage range — Strobes can be synchronized using the Siemens DSC sync modules, FS-250 panel,XLS panel, or PAD-3 power supply with built-in sync protocol — Adjustable volume and tone control — Single stroke or vibrating operation — Fast Installation with In 1 Out screw terminals using #12 to#18 AWG wires — �UL Listed &�ULC Listed; FM,CSFM&NYMEAApproved — Meets OSHA 29 Part 1910.165 — ADAINFPAIUFCIANSI compliant Specifications — Chime appliances shall be Siemens Series CH Chimes,and the chime-strobe appliances shall be Siemens Series CH Chime Strobes or approved equals — The chime shall be AUL Listed under Standard 464 for Audible Signal Appliances,and chimes equipped with strobes shall be listed under aUL Standard 1971 for Emergency Devices for the Hearing-Impaired — Strobes shall incorporate low-temperature compensation to ensure the lowest possible current consumption — All chimes shall use solid state components, and shall provide field-selectable,single-stroke or vibrating operation with volume and tone control — All models shall have a peak sound output of 83 dBA Anechoic at 10 feet, and an adjustable frequency range of 800 to 1200 Hz. — All inputs shall employ terminals that accept#12 to#18 AWG wire sizes — Strobe portion of the appliance shall produce a flash rate of one(1)flash per second over the Regulated Input Voltage Range,and shall incorporate a Xenon flashtube enclosed in a rugged Lexan�lens — Strobe shall be of low-current design,and where multi-Candela Chime Strobes are specified, the strobe intensity shall have field-selectable settings and shall be rated per t9UL Standard 1971 at: ■ 1 5/3017511 1 0cd for wall mount ■ 15l30175195cd or 1151177cd for ceiling mount `08 Series Notification Appliances 2572 SIEMENS Industry, Inc. Building Technologies Division Specifications — (continued) — The selector switch for se�ecting the candela shall be tamper resistant and not accessible from the front of the app�iance — Synchronization is possible when using the Siemens DSC sync modules, FS-250 panel,XLS panel, or PAD-3 power supply with built-in sync protocol — The strobes shall not drift out of synchronization at any time during operation—If the sync module or Power Supply fails to operate, (i.e.,contacts remain closed),the strobe shall revert to a non-synchronized flash rate — The chime and the chime-strobe appliances shall be designed for indoor surface or flush mounting — The chime and chime strobe shall incorporate a chime mounting plate with a grille cover which is secured with two screws for a level,finish and shall mount to standard electrical hardware requiring no additional trim plate or adapter — All notification appliances shall be listed for°Special Applications" General Notes — Strobes are designed to flash at one(1)flash per second minimum over their"Regulated Input Voltage Range" ➢ Note: ** NFPA-72 specifies a flash rate of 1 to 2 flashes per second,while ADA Guidelines specify a flash rate of 1 to 3 flashes per second ** — All candela ratings represent minimum effective Strobe intensity based on�UL Standard 1971 Mounting Diagram � SK • 17 +s • �..r Flf� (Shown In Inches) w � � Mountins� Options � � ��...� ..,. � ���, + � P <��TROBE:SREAIi�` { <3TPCBE SPEAK6R�, 3lJF:FACE BACltBOX .__����\.` ...._.4'`^-.�0.X�176" i^�6Gt BACKB0�7t d-:c,.x y-�r_-. � �I63.�" -- •�� EXTEi^Yc.`�ON F�Na .^-..t'.+RE1lMY. . � ` � 1', '^'�_,c�vua � � VOLUME E f i � � �/�'� �O� .. �,�so / . �.�, Lo((�1H� , , ..� � �Y ,F/ � �� `�/ `^�1FRE OR f r�oUno c�m� �e,r✓� ��c��E�4 _ -��'°� 55 � �uc�ax o:co..wneu�enn,.vu�.+a�a an�cowe�uir w.wvnv: � TONE �.� FQIJ':ARC'dR:M�CdY.GCNCA GOUb.A:.M`C.1":H7.}l:Y S�' x�fALif �art�OF - r^T^r•s � OCT.Ibc;01r.dt�HGtt TRYS:. A:✓J+OiR18 ALV77�t8 A4Y{"sI4 A4Ve3att_ ...Y..�:�.,�,► p oc _ ,.•T •, �-�r_'•: s s a a � MB LO � HI awos+i .w+noR�a �uvo.s�s ww�os�x ae,s.. ar.ro�a nHnos�e �:�a xwos�2 s e e a e e a a SIEMENS Industry, Inc. Building Technologies Division Technical Data �UL tisted Maders and Ratings �����VO�� Maximum RMS Current dBA at 1 D Feet E�����`�����d�} (Chime Only) Reverberant Mo�is �Per�UL 4641 (1/DCNRMS} Max Min Max CH' 16-33.0 Q.022 52 58 CH-CW 16-33_U U.022 52 58 •Available in red and white Note: These notification appliances are OUL Listed as"Special Application,°and are intended to be used only with Siemens notification-appliance circuits. NOTES: 1.The chime must be set at maximum volume for Private Mode Fire Protective Service per f►11.11464 listing requirements. 2.The chime produces a brief inrush current of 0.100 Amps with filtered DC input[0.140 Amps with full-wave-rectified (VRMS)input]with a duration of 100 milliseconds. �t!L tiated Maiets e�d Ratirrgs (� �PP��+�1 �irKm Rt� �A at 1Q Fxt Modd [Per�UL 1971] ������ R�� (Well Mot+�t) �v��sr r� tia► � CH-M�C' 16.0-33.0 O.d24 52 58 1513N75J110 •Available in red and white NOTES: 1.The strobe will produce 1 flash per second over the Input Voltage range. 2.The strobes meet the required light distribution patterns defined in�UL 1971. 3.The chime must be set at maximum volume for Private Mode Fire Protective Service per QUL 464 listing requirements. 4.The chime produces a brief inrush current of 0.100 Amps with filtered DC input[0.140 Amps with full-wave-rectified (VRMS)input]with a duration of 100 milliseconds. f :`WARNING:CANDELA SETTING WILL DETERMINE THE CURRENT DRAW OF THE PRODUCT b�UL Suobe Gurt�tr Rar�ngs Only Maximum RMS Current CM�pa) V 15cd 30cd 75cd 140Cd DG 1 fi-33VDC 0.064 0_09B Q_175 0_233 FWR 16-33VRMS 0.1Q8 Q.164 0258 0_388 Details for Ordering — (Including Mounting Options & Agency Approvals) Agency Approvals „� . � A "v *'�i � a k �F #.'i�t r�. � �� u�:� {.� CH-MC-R 500-636017 Chime:Multi Candela,Red P,Q,R,U,Y X X X X CH-MC-W 500-636018 Chime:Multi Candela,White P,Q,R,U,Y X X X X CH-MC-CR 500-636021 Chime:Multi Candela,Ceilin /Red ,U X X X X CH-MC-CW 500-636022 Chime:Multi Candela,Ceilin /White Q,U X X X X CH-HMC-CW 500-636023 Chime:Hi Multi Candela,Ceilin /White Q,U X X X X CH-R 500-636019 Chime:Red P,Q,R,U,Y X X X X CH-W 500-636020 Chime:White P,Q,R,U,Y X X X X CH-CW 500-636024 Chime:Ceilin /White Q,U X X X X X =listed I approved *=Refer to catalog sheet#:2585 for detailed mounting options Notice: This marketing catalog sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each producYs installation instructions. Fire Safety Fire Safety 8 Femwood Road 2 Kenview Boulevard SIEMENS Industry, If1C. Florham Park,NJ 07932 Brampton,Ontario ��S� Building Technologies Division Tel:(973)593-2600 (Sn) L6T 5E4/Canada Supersedes sheet dated 7/07 FAX:(908)547-6877 Printed in U.S.A. Tel:(905)799-9937 (Rev.1� URL:www.SBT.Siemens.com/FIS FAX:(905)799-9858 SI EM ENS �ata sheet Fire Safety& Security Products `08 Series Notification A liances ZH & ZR — Strobes, Horns, & Horn / Strobes : :or _���..,,��..a. � -- ��F'.R� �� ., « y .. ~ � i ...,.. , � � ... �/= M+.s'�8�. .`� � � y N � � ` � . (ZR & ZH ZH Series ZR Series Mountin ) Product Overview — Strobes can be synchronized using the Siemens DSC sync modules, FS-250 panel, XLS panel, or PAD-3 power supply with built-in sync protocol — Selectable Continuous Horn or Temporal (Code-3)Tones with 90 or 95 dBA selectable setting (ZH) — Ceiling-mount models feature field-selectable Candela settings of 15130175195cd and 1151177cd — Wall-mount models feature field-selectable Candela settings of 151301751110cd and 1351185cd — Base plate is protected by a disposable cover, and the appliances can quickly snap onto the base after the walls are painted — Strobes produce 1 flash per second — "Special Applications"listed with Siemens panels — EZ Mount Universal Mounting Plate (ZBB)— uses single plate for ceiling and wall mount installations — EZ Mount design—with separate base plate— provides ability to pre-wire the base and test the circuit wiring before the walls are covered — BUL Listed &�ULC Listed; FM, CSFM & NYMEA Approved — ADA 1 NFPA compliant Specifications • General — AudiblelVisual notification appliances shall be listed for indoor use only — Appliances shall be listed under eUL Standard 1971 (Standard for Safety Signaling Devices for Hearing Impaired) and 6}UL Standard 464(Fire Protective Signaling) — Appliances shall use a universal back plate,which shall allow mounting to a single-gang, double-gang,4-inch-square, 4"-octal, or a 3-112"-octal backbox — Two-wire appliance wiring shall be capable of directly connecting to the mounting back plate — Continuity check shall occur for entire NAC circuit prior to attaching any audible/visual-notification appliances — Dust cover shall fit and protect the mounting plate — Dust cover shall be easily removed when the appliance is installed over the back plate — Removal of an appliance shall result in a trouble condition by the Fire Alarm Control Panel (FACP) `08 Series Notification Appliances 2584 SIEMENS Industry, Inc. Building Technologies Division Specifications — (continued) . Strobes — Strobe appliances shall produce a minimum flash rate of 60 flashes per minute (1 flash per second)over the Regulated Input Voltage Range, and shall incorporate a Xenon flashtube enclosed in a rugged Lexan� lens — Strobes shall be available with two or four field-selectable settings in one unit, and shall be rated —per BUL 1971 —for up to: . 15130I751110cd for wall mounted . 1351185cd for wall mounted • 1 513 017 519 5cd for ceiling mounted . 1151177cd for ceiling mounted — Strobes shall operate over an extended temperature range of 32°F to 120°F (0°C to 49°C), and be listed for maximum humidity of 95% RH — Strobe inputs shall be polarized for compatibility with standard reverse-polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) . Audibles and Audible/Strobe Combinations — Horns and horn 1 strobes shall be listed for Indoor use under 6�UL Standard 464 — Horns shall be able to produce continuous synchronized output or a temporal code-3 synchronized output — Horns shall have at least 2 sound-level settings of 90 and 95 dBA • Svnchronization Modules — The strobe portion,when synchronization is required, shall be compatible with DSC sync modules, FS-250 panel, XLS panel, or PAD-3 power supply with built-in sync protocol — The strobes shall not drift out of synchronization at any time during operation — Audibles and strobes shall be able to synchronize on a 2-wire circuit with the capability to silence the audible, if required — Strobes shall revert to a non-synchronized flash-rate, if the sync module or Power Supply should fail to operate (i.e. —contacts remain closed) — All notification appliances shall be listed for Special Applications: ■ Strobes are designed to flash at 1-flash-per-second minimum over their "Regulated Input Voltage Range" ➢ Note: NFPA-72 specifies a flash rate of 1-to-2 flashes per second, and ADA Guidelines specify a flash rate of 1-to-3 flashes per second ■ All candela ratings represent minimum-effective Strobe intensity, based on AUL Standard 1971 ■ Series ZH Strobe products are listed under BUL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C)and maximum humidity of 930�0 �+20�� ■ Series ZH horns are listed under 0UL Standard 464 for audible signal appliances (Indoor use only) SIEMENS Industry, Inc. Building Technologies Division Mounting Diagram a.as �.ss� �.es Z�J aes ��� I m � � � e o p � t � + p � 0 � (Shown In Inches) Mountins� Oations � . „ �"� . � �.,�� � BECl�tM6 � � y SCIIEY+S � SIOE.DPENMG� � FiAT SCIIEYfDRIYF�R Fiare 3:�taa F�e4:�d(See my'S Ddo�r) 1. I�mwurt�pa�e a5 strown�fip�a+e 1 b a 9nple�arq, v:. Imporfart:Derice or�r has one riowetinp orierrtatnn.Mae�h the daubk-pxq.4"square.�`oc9apon.or a 3 h"oc�apan backbwc tap ailx base to d�e 1ap of the de�rice. wi&�tFx psovWed p�head screws. To remare dc�t corer. 7. If�a desred to ltrf�er seare the device to tlae base.then eiw ptxe tt�u�and ir�c Tr�per a�t e s d cove�and pull df aption�serews are provided.'o insaaM tl�ese saews pund�aA carer. tt�e scae�r itioks lacaled at dx top and botmm at�e dewce. 2 Canned tield wirin4 Per fipwes 2 areo 3. 2. To remove the appliance,Push a sm�t�al-Eladed screwdriver 3. Addrcss wires badc�to backhnx. imo the side openinp. The screwdmrer m�t r�e�r f�e snap 4. Plaae dust oorer ov�er mouMinp pes�r Fo praees the termius rekase oQaw�p by'.;'ta disengaQe tkee snap. Do not pry oU wnde peAormo�p wRirp c�ninuay check.. Nausinp witn f,e s�ew drwer.apply press�re,ri�s«ew�kiver. 5. RemoMe�hrst cover hefore snap�ep ar insnlling the applimce inserted'n eith¢t side aQeninp.as sFwwn m Fig 4 ta re�ease the aarto tAe mourKnp paa�r per fi�3. housir�. Technical Data zr��d z�c Ho.,r Rewereeraar dsa ztf xom curren[vrsw P��EfL�64 [ZH-MC and ZH at 24V] (�1 � �s-33�dts i6.OV 24V 33_OV H;yh* o.pqq Cor�tinuous H�9h 83 $7 90 � �ow� 0.0�8 Hom Low 77 8f 83 Fy� Higr►* o.oTS Code 3 Hom ar H� h 79 ffi 86 < <ow� a.oas Mkarch Trr�e" Low 72 76 79 �c.oa°""r a���r�. 'Ava�abke�syrtc mode orrly SIEMENS Industry, Inc. Building Technologies Division Technical Data - (continued) U� Listed Mode►s and Ratings qaerat:g vokage ��Gd aPPNc�ion) [per��� Str�obe [Per(9 U11971] S52602] Fbm MOtl�Itifx� Candda Models' (VDClVRMS} {VDCNRMS) (cd) ZR-AAC 16.0-33.0 20.0-31.0 - WaM 15J30I75/11Q ZR-HMC 16.0-33.0 20.d-31.0 - W� 135J185 ZR-MGC 16.0-33.0 2f1.0-31.0 - Ce�g 15/30lT5195 ZR�-IMC-C 16.d-33.0 ZO.Q-31.0 - Ce�g 115/177 ZH-MC 16.0-33.0 20.0-31.0 X Wal 1513Q/T5l110 ZH-diMC 16.D-33.0 2U.0-31.0 X Wal 13�/185 ZH-MGC 16.0-33.0 Z0.0-31.0 X Ce�ng 15l30/T5J95 ZH-HMGC 16.U-33.0 20.0-31.0 X 115J177 ZH 16.0-33.0 2d.d-31.0 X WaN or Ceiti - - *a.�r.�,�.a�d,�,� �UL Current Rating� (ZR Strobe On►y) Maximum RM8 Cc�re�(AAfPS) MC HAitC MC-C HMC-C 15cd 30a! 75cd 110cd 135od 185cd 15c�d 3Ucd 75cd 95cd 115cd 177cd DC 18-33VDC 0.084 0�096 0.'i75 0.233 0.318 Q.445 0.0� 0.111 d.20d 0.284 0.316 0.445 FWR 16-33VRM5 0.108 0.164 0.288 0_368 0.482 a.684 0.117 �.180 0.29T 0.398 d.48Z 0.884 �UL Cument Ratln�s ZH Hcrr►r/Strobe Maximurn RMS C�rent(AMPS) Ewrn h/C FIMC MC-C ti�AC-C Seldng 15cd 3dcd 75cd 110cd 13.5cd 1S.5cd 15cd 30cd 75cd 95cd 115cd 17Ta! DC 16-33VDC �* Q-�8 0_113 0.195 0.258 a.371 0_506 Q_067 0_731 0.222 0_292 0.371 0� �aw 0.070 0_107 0.185 0.2�6 0.3e24 D.455 O.Q75 0_121 0.213 0_277 Q324 0_455 FWR 16-33VRMS FGgh* 0.141 0�00 0.302 0.406 0.521 0_72? 0.149 0316 0�331 0_436 D.521 0_722 low 0.123 D_179 0.290 0.391 Q.497 0.899 0.131 0.195 0.319 0.421 0.497 0_6S9 *CtrrerMt Drew"ss�e ssnie br Ihc Condntiaus Hom; Cade 3 Han and Merch Time Settings Details for Ordering - (Including Mounting Options � Agency Approvals) Agency Approvals � � ,, •��"'��'��+. E a�,,w ��' . � s ��. '" � ZH-R 500-636159 Z Horn: Red B,D,E,F X X X X ZH-W 500-636160 Z Horn: White B,D,E,F X X X X ZH-MC-R 500-636161 Z Horn: Multi Candela(Wall),Red B,D,E,F X X X X ZH-MC-W 500-636162 Z Horn: Multi Candela all,White B,D,E,F X X X X ZH-HMC-R 500-636163 Z Horn: Hi Multi Candela all,Red B D E,F X X X X ZH-HMC-W 500-636164 Z Horn: Hi Multi Candela(Wall),White B,D,E,F X X X X ZH-MC{R 500-636165 Z Horn: Multi Candela Ceilin ),Red B,D,E,F X X X X ZH-MC-CW 500-636166 Z Horn: Multi Candela Ceilin ,White B,D,E,F X X X X ZH-HMC-CR 500-636167 Z Horn: Hi Multi Candela Ceilin ,Red B,D,E,F X X X X 2H-HMC-CW 500-636168 Z Horn: Hi Multi Candela(Ceilin ),White B,D,E,F X X X X ZR-MC-R 500-636769 Z Strobe:Multi Candela all,Red B,D,E,F X X X X ZR-MC-W 500-636170 Z Strobe:Multi Candela(Wall),White B,D,E,F X X X X ZR-HMC-R 500-636171 Z Strobe:Hi Multi{andela(Wall),Red B,D,E,F X X X X ZR-HMC-W 500-636172 Z Strobe:Hi Multi-Candela all),White B,D,E,F X X X X ZR-MC-CR 500�36173 Z Strobe:Multi Candela Ceilin ,Red B,D,E,F X X X X ZR-MC-CW 500-636174 Z Strobe:Multi Candela(Ceilin ),White B,D,E,F X X X X ZR-HMC-CR 500-636175 Z Strobe:Hi Multi Candela(Ceilin ,Red B,D,E,F X X X X ZR-HMC-CW 500-636176 Z Strobe:Hi Multi Candela(Ceilin ,White B,D,E,F X X X X ZBB-R 500-636193 Accessory-(Includes base,dustcover,mounting screws and installation sheet) ZBB-W 500-636194 Accessory-(Includes base,dustcover,mounting screws and installation sheet) X =listed/approved *=Refer to data sheet#:2585 for detailed mounting options Nolfc+�: This marketing data sheet is not intended to be used for system design or instal{ation purposes. for the most up-to-date information,refer to each pr�uct's installatiarr instructions, Fire Safety Fire Safety 8 Femwood Road 2 Kenview Boulevard SIEMENS Industry, If1C. Florham Park,NJ 07932 Brampton,Ontario March 2010 Building Technologies Division Tel:(973)593-2600 (su) L6T 5E4/Canada FAX:(908)547-6877 Printed in U.S.A. Tel:(905)799-9937 SuDersedes sheet dated 12/09 (Rev.2) URL:www.SBT.Siemens.comlFlS FAX:(905)799-9858 PA hcar U10l't hyrhillb Healt e & Rehab GENERAL NOTES 1, ALL SMOKE DETECTOR LOCATIONS ARE DIAGRAMMATIC. THE FOLLOWING RULES MUST BE OBSERVED FOR SMOKE DETECTOR PLACEMENT. A. SMOKE DETECTORS SHALL NOT BE INSTALLED CLOSER THAN 3' FROM AN AIR CONDITIONING VENT PER NFPA 72 (2007 EDITION). B. IN ROOMS SMALLER THAN 30'x30' THE DETECTOR SHALL BE CENTERED IN THE ROOM IF POSSIBLE BY OBSERVING THE ABOVE RULE. C. IN ROOMS WHERE MULTIPLE DETECTORS ARE SHOWN, ONE OF THE FOLLOWING SHALL APPLY PER NFPA 72 (2007 EDITION): 1) THE DISTANCE BETWEEN DETECTORS SHALL NOT EXCEED THEIR LISTED SPACING, AND THERE SHALL BE DETECTORS WITHIN A DISTANCE OF ONE -HALF THE LISTED SPACING, MEASURED AT A RIGHT ANGLE, FROM ALL WALLS OR PARTITIONS EXTENDING TO WITHIN 460MM (18 IN.) OF THE CEILING. 2) ALL POINTS ON THE CEILING SHALL HAVE A DETECTOR WITHIN A DISTANCE EQUAL TO 0.7 TIMES THE LISTED SPACING. 2. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NEC ARTICLE 760, LOCAL CODES, NFPA 72 (2007 EDITION), AND /OR AUTHORITY HAVING JURISDICTION, ALL EQUIPMENT SHALL BE UL LISTED ALL DEVICES SHALL BE COMPATIBLE WITH THE CONTROL PANELS, SYSTEM IS POWER LIMITED PER NEC 760 AND UL 864 REQUIREMENTS. 3. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES BEFORE COMPLETION OF THEIR INSTALLATION. 4. ELECTRICAL CONTRACTOR MUST SET ADDRESSES FOR ADDRESSABLE DEVICES PRIOR TO INSTALLING THE DEVICE. FOR SMOKE DETECTORS, DO NOT MARK ID NUMBERS ON DEVICES LABEL BASE ONLY 5. THE DESIGN INSTALLATION COMPLIES WITH FBC11 -4 -28.3, REFER TO SPECIFICATION SHEETS AND /OR INSTALLATION MANUALS. 6. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. AUDIBLE /VISUAL AND INITIATING CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE. 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE AND TYPE, CONDUCTORS SHALL BE PERMANENTLY AND UNIQUELY MARKED AT FACP, JUNCTION BOXES, POWER EXTENDERS AND DEVICES FOR FUTURE IDENTIFICATION. 8. MINIMUM CONDUIT SIZE WILL BE 3/4 ". CONDUIT SHALL BE NO MORE THAN 40% FILLED PER NEC REQUIREMENTS. 9. ALL 'WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM, 10. UNDERGROUND WIRING IS ACCEPTABLE PROVIDED N.E.C. REQUIREMENTS FOR UNDERGROUND WIRING IS MET, 11, INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES TO SIEMENS. 12. THE 120voc POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70 (2008 EDITION), N.E.C. AND NFPA 72; IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. SEQUENCE OF OPERATION 13. THE FIRE ALARM CONTROL PANEL SHALL NOT BE USED TO POWER ANY UNAUTHORIZED EXTERNAL DEVICE PER NFPA 72; DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN -UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. 14. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN -UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 (2007 EDITION) CHAPTER 7. FAILURE TO COMPLY WITH THIS NOTE WILL VOID ALL WARRANTIES. 15. FIRE ALARM COMPONENTS AND DEVICES MUST BE RATED FOR TEMPERATURE AND HUMIDITY IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 16, DAMPER MOTOR AND FAN SHUTDOWN CONNECTIONS (IF ANY) ARE TO BE COORDINATED IN FIELD WITH HVAC CONTRACTOR. 17. FIRE ALARM POWER SUPPLIES AND ALL REMOTE SUPPLIES MUST BE CONNECTED TO BUILDING POWER OR COLD -WATER GROUND VIA 1 GREEN #12 THHN OR EQUIVALENT. 18. ALL SURGE /TRANSIENT SUPPRESSORS MUST BE CONNECTED TO BUILDING COLD -WATER GROUND. USE SURGE SUPPRESSION ON ALL CIRCUIT CONDUCTORS LEAVING AND ENTERING THE BUILDING. SURGE SUPPRESSION SHALL BE SUITABLE FOR THE INTENDED USE. CIRCUITS SHALL BE PROTECTED FROM INDUCED TRANSIENT VOLTAGE. 19. VERIFY MOUNTING LOCATIONS FOR THE FIRE ALARM CONTROL PANEL, REMOTE PANEL, SIGNAL EXTENDER, AND ANNUNCIATOR PANEL WITH ELECTRICAL CONTRACTOR. 20. THE TRI -D IS A DUAL INPUT MODULE WITH A SINGLE ADDRESS. THE FACP ANNUNCIATES EACH INPUT SEPARATELY. 21. HEAT DETECTORS MUST BE WITHIN 24" OF SPRINKLER HEAD IN ELEVATOR MACHINE ROOM. SMOKE DETECTORS IN THE ELEVATOR MACHINE ROOM SHALL RECALL THE ELEVATOR TO THE DESIGNATED LANDING. IF THE ELEVATOR MACHINE ROOM IS AT THE DESIGNATED LANDING THEN THE ELEVATOR SHALL BE RECALLED TO AN ALTERNATE LANDING. 22. WHERE AUDIBLE APPLIANCE ARE INSTALLED TO PROVIDE SIGNALS FOR SLEEPING AREAS, THEY SHALL HAVE A SOUND LEVEL OF AT LEAST 15 dB ABOVE THE AVERAGE AMBIENT SOUND LEVEL OR 5 dB ABOVE THE MAXIMUM SOUND LEVEL HAVING A DURATION OF AT LEAST 60 SECONDS OR A LEVEL OF AT LEAST 75 dBA, WHICHEVER IS GREATER, U E P L W L E I O G PI D S EPIN F, SING THE A- WEIGHTED SCALE (dBA). rA SOUND LEVEL OF 75dBA SHALL BE ACHIEVED AT ALL SLEEPING AREAS. Q 23. CIRCU'TS LEAVING THE FIRE ALARM CONTROL AND ANY REMOTE PANELS MUST BE INSTALLED TO BE PROTECTED FROM PHYSICAL DAMAGE, AS WELL AS ATTACK FROM FIRE BY PROVIDING AS ATTACK FROM FIRE BY PROVIDING 2 HOUR RATED PROTECTION AS PER NFPA 72 6.9.4.3. (2007 EDITION). 24. THE 20 VAC CIRCUIT NUMBER FOR THE FIRE ALARM PANELS SHALL BE CONFIRMED IN THE FIELD, USING THE FOLLCENING INFORMATION: A. PER NFPA 72 SECTION 4.4.1.4 (2007 ED.) 1) THE CIRCUIT BREAKER SHALL HAVE A RED MARKING, SHALL BE ACCESSIBLE ONLY BY AUTHORIZED PERSONNEL, AND SHALL BE IDENTIFIED AS "FIRE ALARM CIRCUIT ", 2) THE LOCATION OF THE CIRCUIT DISCONNECT MEANS (CIRCUIT BREAKER) SHALL BE PERMANENTLY IDENTIFIED ON THE FIRE ALARM PANEL, B. THE MAIN FIRE ALARM PANEL REQUIRES AN AC INPUT CURRENT OF 3.5 AMPS PER EACH PSC -12 AND EACH PSX -12 POWER SUPPLY. C THE PAD -3 POWER EXTENDER PANELS REQUIRE AN AC INPUT CURRENT OF 2.5 AMPS. D. 1*HE BREAKER FOR THE FIRE ALARM CIRCUIT SHALL NOT BE GREATER THAN 20 AMPS AND NOT LOADED ABOVE 80% OF ITS VALUE. E. ALL A.C. POWER FOR THE FIRE ALARM PANELS SHALL BE PROVIDED FROM LIFE SAFETY (EMERGENCY) BRANCH CIRCUITS. INFORMATION REGARDING THE CORRECT BRANCH CIRCUIT SHALL BE PROVIDED BY THE INSTALLER SHALL BE INCLUDED IN THE AS -BUILT DRAWING SET, 1. ACTIVATION OF ANY AUTOMATIC SMOKE DETECTOR, AUTOMATIC HEAT DETECTOR, OR SPRINKLER WATER -FLOW SWITCH SHALL CAUSE THE FOLLOWING EVENTS, ACTIONS, AND INDICATIONS: A. DISPLAY A CUSTOM MESSAGE DESCRIBING THE DEVICE ORIGINATING THE ALARM CONDITION AT THE FIRE ALARM CONTROL PANEL AND STORE THE EVENT IN THE HISTORY LOG OF THE PANEL. B. SOUND AN ALERT TONE AT THE FIRE ALARM CONTROL PANEL UNTIL THE ALARM CONDITION IS ACKNOWLEDGED. D. ACTIVATE AUDION /VISUAL ALARM CIRCUITS AS PROGRAMMED, UNTIL PANEL IS RESET. E. ACTIVATE RELAYS TO PERFORM THE FOLLOWING ACTIONS: F. ACTIVATE DIALER TO CALL OFF -SITE MONITORING STATION. 2. ACTIVATION OF ANY MANUAL PULL STATION SHALL CAUSE THE EVENTS, ACTIONS, AND INDICATIONS; AS DESCRIBED NUMBER 1 ABOVE, EXCEPT FOR THE ACTIONS AS DESCRIBED IN NOTE (E). 3. ACTIVATION OF ANY SUPERVISORY DEVICE WITHIN THE SYSTEM SHALL CAUSE THE FOLLOWING ACTIONS AND INDICATIONS: A. ACTIVATE THE SUPERVISORY LIGHT AND SOUNDER AT THE FIRE ALARM CONTROL PANEL AND ANNUNCIATORS, IF ANY. B. DISPLAY A CUSTOM MESSAGE DESCRIBING THE LOCATION OF THE DEVICE INITIATING THE EVENT. C. ANY DUCT MOUNTED SMOKE DETECTORS SHALL, CAUSE THE SHUTDOWN OF THE ASSOCIATED AIR HANDLER OR CLOSURE OF THE ASSOCIATED DAMPER. SYSTEM WILL SHOW A SUPERVISORY ALARM. D. ACTIVATE DIALER TO CALL OFF -SITE MONITORING STATION. 4. ACTIVATION OF ANY TROUBLE CONDITION SHALL CAUSE THE FOLLOWING EVENTS, ACTIONS AND INDICATIONS. A. DISPLAY A CUSTOM MESSAGE DESCRIBING THE TROUBLE CONDITION AT THE FIRE ALARM CONTROL CONTROL PANEL AND STORE THE EVENT IN THE HISTORY LOG OF THE PANEL. B. SOUND AN ALERT TONE AT THE FIRE ALARM CONTROL PANEL UNTIL THE TROUBLE CONDITION IS ACKNOWLEDGED, C. ACTIVATE THE COMMON TROUBLE RELAY FOR OFF -SITE MONITORING STATION. SYMBOL LEGEND SYM DESCRIPTION MODEL NOTES FACP FIRE ALARM CONTROL PANEL XLS (SUPPLIED BY SIEMENS) PWR AUXILIARY SIGNAL POWER BOOSTER FIRE ALARM (SUPPLIED BY SIEMENS) FA_N_N1 REMOTE ANNUNCIATOR PANEL AUDIBLE /VISUAL DEVICE (SUPPLIED BY SIEMENS) 7' -0" AFF PHOTOELECTRIC DETECTOR WYITH STANDARD BASE FDOT (SUPPLIED BY SIEMENS) © DUAL ACTION MANUAL PULL 'STATION MSI - LOB EXISTING TO REMAIN DM ADDRESSABLE INTERFACE MOUDULE W/ RELAY TRI -R EXISTING TO REMAIN T CHIME /STROBE SELECT CD MALL MOUNT CH -MZ (SUPPLIED BY SIEMENS) 48" AFF STROBE SELECT CD ZR -MC (SUPPLIED BY SIEMENS) TO TOP OF FLOW SWITCH BY OTHERS EXISTING TO REMAIN ACTIVATION TAMPER SWITCH BY OTHERS EXISTING TO REMAIN FINISHED FLOOR DUCT DETECTOR AD2 -P EXISTING TO REMAIN ® HEAT DETECTOR FPT -11 EXISTING TO REMAIN TYPICAL ELEVATION DETAIL TYPICAL ELEVATION DETAIL OF AUDIBLE /VISUAL ALARM DEVICE OF VISUAL ALARM DEVICE OF MANUAL PULL STATION OF AUIDIBLE DEVICE NOTE: SEE PRODUCT INSTALL - ATION INSTRUCTIONS FOR SPECIFIC MOUNTING, WIRING AND SETTINGS DETAILS FOR EACH DEVICE. A.Js;vil7'fE:l FtANOIS) 11AVE)1EEN RE4?`EW' )'f Z1 PIT`S Hl LS TARE MARSHAL, S OFFICE ('lease be advised this review of plans submitted is a CJJ(Sory review to assist the contractor in compliance with applicable fire safety codes. This review is not intended to bra a final approval of the submitted plans, It is the contractor's sole responsibility to ensure that the plans are in complete compliance with all applicable NFPA codes and local ordinances, In the event that further examination or site inspection reveals areas of non - compliance, it shall be the contractor's sale responsibility, at their sole expense to bring those areas in compliance, The City assumes no responsibility for the contractor's failure to be in compliance with all applicable NFPA Codes and local ordinances, WIRE LEGEND MOUNTING HEIGHTS SUGGESTED WIRE TYPE COLOR CODE NOTES: 1. USE FPLP TYPE WIRE FOR RUNS IN PLENUM SPACE. 2. USE FPLR TYPE WIRE FOR VERTICAL THRU -FLOOR RUNS, 3. USE FPL WIRE WHICH IS RATED FOR WET LOCATIONS, FOR ALL UNDERGROUND RUNS; OR AS REQUIRED BY CODE NFPA 70. 4. THHN WIRE IS ACCEPTABLE FOR USE AS SHOWN ON LEGEND. A I 18/2 TWISTED PAIR FPL YELLOW FIRE ALARM FIRE ALARM FIRE ALARM MUST BE IN CONDUIT AUDIBLE DEVICE OPNLY AUDIBLE /VISUAL DEVICE VISUAL DEVICE ONLY UP TO 7' -0" AFF TS 80" AFF 80" AFF ` 90" AFF TO BOTTOM TO BOTTOM MANUAL STATION TO TOP OF STROBE OF STROBE T OF DEVICE 48" AFF TO TOP OF ACTIVATION FINISHED FLOOR FINISHED FLOOR FINISHED FLOOR FINISHED (FLOOR e TYPICAL ELEVATION DETAIL TYPICAL ELEVATION DETAIL TYPICAL ELEVATION DETAIL TYPICAL ELEVATION DETAIL OF AUDIBLE /VISUAL ALARM DEVICE OF VISUAL ALARM DEVICE OF MANUAL PULL STATION OF AUIDIBLE DEVICE A.Js;vil7'fE:l FtANOIS) 11AVE)1EEN RE4?`EW' )'f Z1 PIT`S Hl LS TARE MARSHAL, S OFFICE ('lease be advised this review of plans submitted is a CJJ(Sory review to assist the contractor in compliance with applicable fire safety codes. This review is not intended to bra a final approval of the submitted plans, It is the contractor's sole responsibility to ensure that the plans are in complete compliance with all applicable NFPA codes and local ordinances, In the event that further examination or site inspection reveals areas of non - compliance, it shall be the contractor's sale responsibility, at their sole expense to bring those areas in compliance, The City assumes no responsibility for the contractor's failure to be in compliance with all applicable NFPA Codes and local ordinances, WIRE LEGEND SYM DESCRIPTION SUGGESTED WIRE TYPE COLOR CODE NOTES: 1. USE FPLP TYPE WIRE FOR RUNS IN PLENUM SPACE. 2. USE FPLR TYPE WIRE FOR VERTICAL THRU -FLOOR RUNS, 3. USE FPL WIRE WHICH IS RATED FOR WET LOCATIONS, FOR ALL UNDERGROUND RUNS; OR AS REQUIRED BY CODE NFPA 70. 4. THHN WIRE IS ACCEPTABLE FOR USE AS SHOWN ON LEGEND. A SLC (ANALOG LOOP) 18/2 TWISTED PAIR FPL YELLOW C STROBE ONLY or CHIME /STROBE CIRCUIT 14/2 FPL / THHN RED NAC NOTIFICATION APPLIANCE CIRCUIT FS FLOW SWITCH TS TAMPER SWITCH CODE REFERENCES THE FOLLOWING CODES HAVE BEEN REFERENCED, AND APPLIED WHEREAF NECESSARY: NFPA 72 (2007) NATIONAL FIRE ALARM CODE NFPA 70 (2008) NATIONAL ELECTRIC CODE (NEC) NFPA 13 (2007) STANDARD ON SPRINKLER SYSTEMS NFPA 101 (2009) LIFE SAFETY CODE NFPA 92A (2009) STANDARD FOR SMOKE CONTROL SYSTEMS UTILIZING BARRIERS AND PRESSURE DIFFERENCES. NFPA 92B (2009) STANDARD FOR SMOKE MANAGEMENT SYSTEMS IN MALLS, ATRIA AND LARGE SPACES FBC (2010) FLORIDA BUILDING CODE FFPC (2010) FLORIDA FIRE PROTECTION CODE SCOPE OF WORK 1. REPLACING AN EXISTING MXL FIRE ALARM PANEL TO AN XLS FIRE ALARM PANEL, REPLACING IONIZATOIN SMOKE DETECTORS TO PHOTOELECTRIC SMOKE DETECTORS, AND REPLACING EXISTING NOTIFICATION DEVICES WITH NEW NOTIFICATION DEVICES. 2. PROGRAM, TEST, AND CERTIFY THE COMPLETED FIRE ALARM SYSTEM, ABBREVIATIONS F.B.O. FURNISHED BY OTHERS WP WEATHERPROOF H.O. HIGH OUTPUT FPL FIRE POWER LIMITED CD CANDELA AFF ABOVE FINISHED FLOOR SLC SIGNALING LINE CIRCUIT NAC NOTIFICATION APPLIANCE CIRCUIT FS FLOW SWITCH TS TAMPER SWITCH THE DRAWING AND DESIGN HEREIN SHALL NOT BE DUPLICATED, USED OR DISCLOSED TO OTHERS FOR PROCUREMENT OR OTHER PURPOSE (EXCEPT AS OTHERWISE AUTHORIZED BY CONTRACT) WITHOUT WRITTEN PERMISSION OF SIEMENS BUILDING TECHNO- LOGIE3, INC.. FIRE SAFETY DIVISION. ALL OTHER REPRODUCTIONS SHALL BEAR THIS NOTICE, R E V I S I O N S No. I Revision I By I Cate OSHPO NUMBER: PROFESSIONAL ENGINEERS APPROVAL STAMP: FREUD ENTERPRISES CONSULTINC,£Nc Nu // 880 PEEP LS Voke 9"��jy95Q ��FC }� Jyi No 32578 sA .�, CEQRCE FRED P,E. r 1e7��i/��\ G� J I -/I Il DESIGN ENGINEERS: CONTRACTOR'S NAME & ADDRESS: Siemens Industries, Inc. Building Technologies Division TAMPA BRANCH 8403 Benjamin Road Tampa, Florida 33634 Tel (813) 261 -8700 Fax (813) 890 -8055 Florida State EF License No EF2000416 U L. Certificate ID No 603961 -030 PRODUCT MANUFACTURER: SIEMENS Siemens Indusifies, Inc, Building Technologies Division TAMPA BRANCH 8403 Benjamin Road Tampa, Florida 33634 Tel(813)261 -8700 Fax(813)890 -8055 Florida State EF License No. EF2000416 U.L. Certificate ID No. 603961 -030 JOB NAME & LOCATION (STREET ADDRESS) Zephyrhills Healthcare and Rehab 7350 Dairy Rd. Zephyrhills, FI 33541 SHEET CONTENTS: INSTALLATION TYPE 3 NEW INSTALLATION [3 DESIGN/BUILD 0 PER CONTRACT DOCUMENT 0 EXISTING BASE JOB # N/A 0 OTHERS SYSTEM SALES REP.: John Bourdeau PROJECT MANAGER: DRAWN BY: Guillermo Grande CAD FILENAME: SCALE. DATE DRAWN: PLOT DATE: December 10. 2013 SHEET OF 1 5 JOB NUMBER 5200368848 • 75CD V5 -1 P 1.013 0 2.012 CORRIDOR COURTYARD 2.011 2.010 STOR. 27 V3 -5 2.013 ILI O OFFICE JAN. 75CD V3 -1 CORR. 75CD 278 .014 RECEIVING P 75CD z7s P • V3 -6 EOUCq.002 2.003 2.015 15C 0 V3 -7 >ERVIC 15CD )URTY V3 -2 V3 -4 15CD 5CD MECH. EQUIP, SOIL 290 2.004 Ll,,EN CLEAN V3 -8 COOLER LINEN V2 -2 STAFF 280 3::( LOUNGE L RY 75CDC 2.017 277 2018 . EMERG. 283 O O SERVIC ELEC. 15CD DRYERS 2.005 V3 -3 75CD FREEZEf 289 `2.006 V2 -3 2.016 038 � O COURTYARD 75CD V2 -4 P 037 281 2.036 KITCHEN 271 P V7 75CD 4 .020 - -- LL V7 -5 15CO BEAUTY SH OR �? V7 -6 192 2.021 DINING ROOM 110 STOR 193 STOR 75CD 194 0 V7 -7 15CD 2.023 -g t9s P 2.019 75CD V4 -1 15CD 0 CHAPEL O tog 2.022 V7 -9 75CD 2.024 V7 -10 CONF. PVT. DINING 195 FACP FIRE ALARM CONTROL PANEL O tot 2.025 2.026 0 XWASHi L088Y 0,2 75CD P 2.027 V4 -9 ADMIN ADMISSION OFFICE SOC. Q V4 -8 103 269 2.028 15CD j29 5CD 15CD V4 -3 RECEPTION 105 V4 -2 D.D.N. OFFICE VV4-( -4 104 �-C 75CDC 2.030 O tRKRM KEEPER DINING ROOM 75CD 106 268 V4 -^ 2.034 2.032 UViNG O ROOM 2.033 201 2,031 a 75CD V4 -7 75CD 3.014 3.013 MECH 2 2 2 2 BR BR gR BR SPECIAL 3.016 DINING CL/ ROOM RECEPTfON 2 SLIPPLJES O SPECIAL V2 -10 SOAR JAN ROOM BR 3.015 CARE nY-(C 2.035 15CDO 0 17 VV 2---��� -5 15C 3 ACTIVITIES 75CD VV22 -9 DIR STOR V2 3 021 03.033 75CD 3.040 32 75CD P V2 -8 3.024 V1 -7 018 NURSE75CD STATION 042 501 L UTII TR TCH CHART' SCDO ELEC LC 3 pT 1 3.041 3.022 3.0023 V1 0z o, un sO OFFICE Dz 2 Dz z z 2 �' 3.025 MEO REC 3.026 STORAGE BR BR BR BR O WORK O 75CDC V1 -2 MED STORAGE 15CD PREP a-Q 3.030 BA, 3.027 �3 0 029 S70R 3.0028 0 115CD 61 PVT BR PVT BR H1 PVT BR PVT BR HI PVT BR PVT BR G1 PVT 31 BR 75CD V1 -4 F2 PVT BR t 3.047 06 O J Ua -a r F2 PVT BR 3.048 5CD 0 QV1 -5 31.049 PVT SR G1 PARTIAL FIRE AUUM SYSTEM SCALE: 1/8" = 1' -0" PVT BR H1 PVT BR D 0 D 8 PVT BR I I I I PBR F2 PVT PVT PVT BR BR BR fBR PVT O O Ir 0 1043 1.095 V1 -9 O 75CD 3.044 P 3.045 0 PVT PVT PVT BR I I BR I n / 1 I BR BR II II BR THE DRAWING AND DESIGN HERFJN SHALL NOT BE DUPLICATED, USED OR DISCLOSED TO OTHERS FOR PROCUREMENT OR OTHER PURPOSE (EXCEPT AS OTHERWISE AUTHORIZED BY CONTRACT) WITHOUT WRITTEN PERMISSION OF SIEMENS BUILDING TECHNO- 001 ELEC. EQUIP. O STOR. 28 HSKG STOR{2 009 Revision By tMECH 2.00 JAN. 279 O PWR PWR • 75CD V5 -1 P 1.013 0 2.012 CORRIDOR COURTYARD 2.011 2.010 STOR. 27 V3 -5 2.013 ILI O OFFICE JAN. 75CD V3 -1 CORR. 75CD 278 .014 RECEIVING P 75CD z7s P • V3 -6 EOUCq.002 2.003 2.015 15C 0 V3 -7 >ERVIC 15CD )URTY V3 -2 V3 -4 15CD 5CD MECH. EQUIP, SOIL 290 2.004 Ll,,EN CLEAN V3 -8 COOLER LINEN V2 -2 STAFF 280 3::( LOUNGE L RY 75CDC 2.017 277 2018 . EMERG. 283 O O SERVIC ELEC. 15CD DRYERS 2.005 V3 -3 75CD FREEZEf 289 `2.006 V2 -3 2.016 038 � O COURTYARD 75CD V2 -4 P 037 281 2.036 KITCHEN 271 P V7 75CD 4 .020 - -- LL V7 -5 15CO BEAUTY SH OR �? V7 -6 192 2.021 DINING ROOM 110 STOR 193 STOR 75CD 194 0 V7 -7 15CD 2.023 -g t9s P 2.019 75CD V4 -1 15CD 0 CHAPEL O tog 2.022 V7 -9 75CD 2.024 V7 -10 CONF. PVT. DINING 195 FACP FIRE ALARM CONTROL PANEL O tot 2.025 2.026 0 XWASHi L088Y 0,2 75CD P 2.027 V4 -9 ADMIN ADMISSION OFFICE SOC. Q V4 -8 103 269 2.028 15CD j29 5CD 15CD V4 -3 RECEPTION 105 V4 -2 D.D.N. OFFICE VV4-( -4 104 �-C 75CDC 2.030 O tRKRM KEEPER DINING ROOM 75CD 106 268 V4 -^ 2.034 2.032 UViNG O ROOM 2.033 201 2,031 a 75CD V4 -7 75CD 3.014 3.013 MECH 2 2 2 2 BR BR gR BR SPECIAL 3.016 DINING CL/ ROOM RECEPTfON 2 SLIPPLJES O SPECIAL V2 -10 SOAR JAN ROOM BR 3.015 CARE nY-(C 2.035 15CDO 0 17 VV 2---��� -5 15C 3 ACTIVITIES 75CD VV22 -9 DIR STOR V2 3 021 03.033 75CD 3.040 32 75CD P V2 -8 3.024 V1 -7 018 NURSE75CD STATION 042 501 L UTII TR TCH CHART' SCDO ELEC LC 3 pT 1 3.041 3.022 3.0023 V1 0z o, un sO OFFICE Dz 2 Dz z z 2 �' 3.025 MEO REC 3.026 STORAGE BR BR BR BR O WORK O 75CDC V1 -2 MED STORAGE 15CD PREP a-Q 3.030 BA, 3.027 �3 0 029 S70R 3.0028 0 115CD 61 PVT BR PVT BR H1 PVT BR PVT BR HI PVT BR PVT BR G1 PVT 31 BR 75CD V1 -4 F2 PVT BR t 3.047 06 O J Ua -a r F2 PVT BR 3.048 5CD 0 QV1 -5 31.049 PVT SR G1 PARTIAL FIRE AUUM SYSTEM SCALE: 1/8" = 1' -0" PVT BR H1 PVT BR D 0 D 8 PVT BR I I I I PBR F2 PVT PVT PVT BR BR BR fBR PVT O O Ir 0 1043 1.095 V1 -9 O 75CD 3.044 P 3.045 0 PVT PVT PVT BR I I BR I n / 1 I BR BR II II BR THE DRAWING AND DESIGN HERFJN SHALL NOT BE DUPLICATED, USED OR DISCLOSED TO OTHERS FOR PROCUREMENT OR OTHER PURPOSE (EXCEPT AS OTHERWISE AUTHORIZED BY CONTRACT) WITHOUT WRITTEN PERMISSION OF SIEMENS BUILDING TECHNO- LOGIES, INC.. FIRE SAFETY DIVISION, ALL OTHER REPRODUCTIONS SHALL BEAR THIS NOTICE, R E V I S I O N S No. Revision By Date OSHPO NUMBER: PROFESSIONAL ENGINEERS APPROVAL STAMP: FREIJO,,F,NTEPV�,RISES CON 330 P�EP' fR� - AT A1i�CF 3 5 W lce. 45 -Fax. 6 6)iI 7 �U78 E- ryail'. f�e�jog mnet / No 32578 '. _ = �Q, STI E OF '� d+aHF�7e' o. 0 \. OA DESIGN ENGINEERS: CONTRACTOR'S WE & ADDRESS: Siemens Industries, Inc. Building Technologies Division TAMPA BRANCH 8403 Benjamin Road Tampa, Florida 33634 Tel (813) 261 -8700 Fax (813) 890 -8055 Florida State EF License No EF2000416 U L Certificate ID No 603961 -030 PRODUCT MANUFACTURER: SIEMENS Siemens Industries, Inc, Building Technologies Division TAMPA BRANCH 8403 Benjamin Road Tampa, Florida 33634 Tel(813)261 -8700 Fax(813)890 -8055 Florida State EF License No. EF2000416 U.L. Certificate ID No 603961 -030 JOB NAME & LOCATION (STREET ADDRESS) Zephyrhills Healthcare and Rehab 7350 Dairy Rd. Zephyrhills, Fl 33541 SHEET CONTENTS: INSTALLATION TYPE El NEW INSTALLATION O DESIGN /BUILD PER CONTRACT DOCUMENT 0 EXISTING BASE JOB # N/A E3 OTHERS SYSTEM SALES REP.: John Bourdeau PROJECT MANAGER: DRAWN BY: Guillermo Grande CAD FILENAME: SCALE: DATE DRAWN: PLOT DATE: December 10, 2013 SHEET Of JOB NUMBER 2 5 5200368848 PARTIAL FIRE ALARM SYSTEM SCALE: 1/8" = 1' -0" THE DRAWING AND DESIGN HEREIN SHALL NOT BE DOPUCATED, USED OR DISCLOSED TO OTHERS FOR PROCUREMENT OR OTHER PURPOSE (EXCEPT AS OTHERWISE AUTHORIZED BY CONTRACT) WITHOUT WRITTEN PERMISSION OF SIEMENS BUILDING TECHNO- LDC!ES, INC.. FIRE SAFETY DMSION, ALL OTHER REPRODUCTIONS SHALL BEAR THIS NOTICE. R E V I S I O N S No. Revision By Date OSHPD NUMBER: PROFESSIONAL ENGINEERS APPROVAL STAMP: FREIJO ENTERPRISES C ,VSUL q-fNu K6feEERS � htt 880 PE F GSA ��I 8 L 3341 5 � �` 5 Eit 'E 675". '5�, � -mid fie ��)og�att, net Q -� � 1 * No 32578 � §TAT�q C. O �,. E'r ( It FREIJOnP,E. f0 6Mipr�y�tf - y7 r, DESIGN ENGINEERS: CONTRACTOR'S NAME & ADDRESS: Siemens Industries, Inc. Building Technologies Division TAMPA BRANCH 8403 Benjamin Road Tampa, Florida 33634 Tel (813) 261 -8700 Fax (813) 890 -8055 Florida State EF License No. EF2000416 U . Certificate ID No 603961 -030 PRODUCT MANUFACTURER: SIEMENS Siemens Industries, Inc, Building Technologies Division TAMPA BRANCH 8403 Benjamin Road Tampa, Florida 33634 Tel(813)261 -8700 Fax(813)890 -8055 Florida State EF License No EF2000416 U.L. Certificate ID No. 603961 -030 JOB NAME & LOCATION (STREET ADDRESS) Zephyrhills Healthcare and Rehab 7350 Dairy Rd. Zephyrhills, Fl 33541 SHEET CONTENTS: INSTALLATION TYPE O NEW INSTALLATION E3 DESIGN /BUILD PER CONTRACT DOCUMENT E3 EXISTING BASE JOB # N/A E3 OTHERS SYSTEM SALES REP.: John Bourdeau PROJECT MANAGER: DRAWN BY: Guillermo Grande CAD FILENAME: SCALE. DATE DRAWN: PLOT DATE: December 10, 2013 SHEET OF JOB NUMBER 3 5 5200368848 TO TELCO RM. 2 DEDICATED PHONE LINES 1Y POWER INPUT A (TYP) A (TYP) A (TYP) 120VAC -60 HZ C (Ty P) C (Ty P) 10 AWG GRN THHN GROUND WIRE 6 Amps Max, 20 AM1PS MAX. C PANEL CKT# POWER INPUT 120VAC -60 HZ 10 AWG GRN THHN GROUND WIRE 6 Ar 20 AMPS MAX. POWER INPUT 120VAC -60 HZ 10 AWG GRN THHN GROUND WIRE 20 AMPS MAX. FIRE ALARM RISER SCALE. ./8 - 1'-0" 3.049 3.048 3.047 3.046 3.045 3.044 3.043 3.042 3.041 3.040 3.033 3.032 3.031 3.030 3.029 3.028 3.013 3.014 3.015 3.016 3.017 3.018 3.019 3.020 3.021 3.022 3.023 3.024 3.025 3.026 3.027 2.030 2.031 2.032 2.033 2.034 2.035 2.036 2.037 2.038 2.029 2.028 2.027 2.026 2.025 2.024 2.023 2.022 2.021 2.020 2,019 2.018 2.017 2.016 2.015 2.001 2.002 2.003 2.004 2.005 2.006 2.007 2.008 2.009 2.010 2.011 2.012 2.013 2.014 2.015 4� 1.031 1.032 1.033 1.034 1.035 1.036 1.037 1.038 1.039 1.040 1.055 1.095 1.030 1.029 1.028 1.027 1.026 1.025 1.024 1.023 1.022 1.021 1,020 1.019 1.018 1.017 1.016 1.001 1.003 1.004 1.005 1.006 1.007 1.008 1.009 1.010 1.011 1.012 1.013 1.013 1.014 1.015 C (Ty P) C (TYP) C (Ty P) p-' o Ln p Ln I-- Lr) r\ Ln � Ln l� > - > � > r- > - > Q 7 p N Ln (D CO I- > > � N � > � > Ln cDD Ln (o UC) cD -> •-> r--> 0 p p co C:) C)-) p r-_ > -> �> I-> p(0 00 Ln CD Lr) CD li CD r- > r-- > > p rn CD d p Ln c0 U I U I U I U I - > � > - > � > p� pN on p-' pUn pcD U U I U I U I U I U I Ln --:I- Ln �- Ln �r Ln � Ln � Ln �s- I \ > r-- > > I \ > I \ > r- > C (Ty P) o U I r- > C (Ty P) C (1-y P) C (Ty P) p CN p rn p� p Ln p (.0 U I U I U I U I U I p N U LO r-> �> un > Ln > p- pN pLn L Ln I I i-n I Ln I s PURPOSE (EXCEPT AS OTHERWISE AUTHORIZED BY CONTRACT) V6 CAB -3 v®7v SHALL BEAR THIS NOTICE. R E V I S I O N S o_ Q11 00 CC-) I FACP A (TYP) A (TYP) A (TYP) 120VAC -60 HZ C (Ty P) C (Ty P) 10 AWG GRN THHN GROUND WIRE 6 Amps Max, 20 AM1PS MAX. C PANEL CKT# POWER INPUT 120VAC -60 HZ 10 AWG GRN THHN GROUND WIRE 6 Ar 20 AMPS MAX. POWER INPUT 120VAC -60 HZ 10 AWG GRN THHN GROUND WIRE 20 AMPS MAX. FIRE ALARM RISER SCALE. ./8 - 1'-0" 3.049 3.048 3.047 3.046 3.045 3.044 3.043 3.042 3.041 3.040 3.033 3.032 3.031 3.030 3.029 3.028 3.013 3.014 3.015 3.016 3.017 3.018 3.019 3.020 3.021 3.022 3.023 3.024 3.025 3.026 3.027 2.030 2.031 2.032 2.033 2.034 2.035 2.036 2.037 2.038 2.029 2.028 2.027 2.026 2.025 2.024 2.023 2.022 2.021 2.020 2,019 2.018 2.017 2.016 2.015 2.001 2.002 2.003 2.004 2.005 2.006 2.007 2.008 2.009 2.010 2.011 2.012 2.013 2.014 2.015 4� 1.031 1.032 1.033 1.034 1.035 1.036 1.037 1.038 1.039 1.040 1.055 1.095 1.030 1.029 1.028 1.027 1.026 1.025 1.024 1.023 1.022 1.021 1,020 1.019 1.018 1.017 1.016 1.001 1.003 1.004 1.005 1.006 1.007 1.008 1.009 1.010 1.011 1.012 1.013 1.013 1.014 1.015 C (Ty P) C (TYP) C (Ty P) p-' o Ln p Ln I-- Lr) r\ Ln � Ln l� > - > � > r- > - > Q 7 p N Ln (D CO I- > > � N � > � > Ln cDD Ln (o UC) cD -> •-> r--> 0 p p co C:) C)-) p r-_ > -> �> I-> p(0 00 Ln CD Lr) CD li CD r- > r-- > > p rn CD d p Ln c0 U I U I U I U I - > � > - > � > p� pN on p-' pUn pcD U U I U I U I U I U I Ln --:I- Ln �- Ln �r Ln � Ln � Ln �s- I \ > r-- > > I \ > I \ > r- > C (Ty P) o U I r- > C (Ty P) C (1-y P) C (Ty P) p CN p rn p� p Ln p (.0 U I U I U I U I U I p N U LO r-> �> un > Ln > p- pN pLn L Ln I I i-n I Ln I U I I U 0I n M Un d- Ln �t Ln d- r- > > r- > U rl U 00 j Ln j s PURPOSE (EXCEPT AS OTHERWISE AUTHORIZED BY CONTRACT) V6 LOGIES, INC.. FIRE SAFETY DIVISION, ALL OTHER REPRODUCTIONS SHALL BEAR THIS NOTICE. R E V I S I O N S o_ Q11 00 CC-) n0 I - - n > > _ > > U I I U 0I n M Un d- Ln �t Ln d- r- > > r- > U rl U 00 j Ln j THE DRAWING AND DESIGN HEREIN SHALL NOT BE DUPLICATED, USED OR DISCLOSED TO OTHERS FOR PROCUREMENT OR OTHER PURPOSE (EXCEPT AS OTHERWISE AUTHORIZED BY CONTRACT) V3 LOGIES, INC.. FIRE SAFETY DIVISION, ALL OTHER REPRODUCTIONS SHALL BEAR THIS NOTICE. R E V I S I O N S 0 �II 3y Date UPI OSHPO NUMBER: PROFESSIONAL ENGINEERS APPROVAL STAMP: FREIJO ENTERPRISES CONSULT,N;\ /// C 880 PEEPL V Mlffff4o fL - 15 C C V2 I �I �J �\ U I U I U U I Ln Ln Ln Ln Tel(813)261 -8700 Fax(813)890 -8055 Florida State EF License No EF2000416 U.L. Certificate ID No. 603961 -030 PRODUCT MANUFACTURER: SIEMENS THE DRAWING AND DESIGN HEREIN SHALL NOT BE DUPLICATED, USED OR DISCLOSED TO OTHERS FOR PROCUREMENT OR OTHER PURPOSE (EXCEPT AS OTHERWISE AUTHORIZED BY CONTRACT) WITHOUT 'WRITTEN PERMISSION Of SIEMENS BUILDING TECHNO- LOGIES, INC.. FIRE SAFETY DIVISION, ALL OTHER REPRODUCTIONS SHALL BEAR THIS NOTICE. R E V I S I O N S No Revision 3y Date OSHPO NUMBER: PROFESSIONAL ENGINEERS APPROVAL STAMP: FREIJO ENTERPRISES CONSULT,N;\ /// 880 PEEPL V Mlffff4o fL - 15 ' - No 32578 OF W- FORCE FREUD P E. ,' 4 �J �\ DESIGN ENGINEERS: CONTRACTOR'S WE & ADDRESS, Siemens Industries, Inc, Building Technologies Division TAMPA BRANCH 8403 Benjamin Road Tampa, Florida 33634 Tel(813)261 -8700 Fax(813)890 -8055 Florida State EF License No EF2000416 U.L. Certificate ID No. 603961 -030 PRODUCT MANUFACTURER: SIEMENS Siemens Industries, Inc, Building Technologies Division TAMPA BRANCH 8403 Benjamin Road Tampa, Florida 33634 Tel(813)261 -8700 Fax(813)890 -8055 Florida State EF License No. EF2000416 U L Certificate ID No. 603961 -030 JOB NAME & LOCATION (STREET ADDRESS) Zephyrhills Healthcare and Rehab 7350 Dairy Rd. Zephyrhills, FI 33541 SHEET CONTENTS: INSTALLATION TYPE E3 NEW INSTALLATION 0 DESIGN /BUILD PER CONTRACT DOCUMENT 0 EXISTING BASE JOB # N/A 0 OTHERS SYSTEM SALES REP: John Bourdeau PROJECT MANAGER: DRAWN BY: Guillermo Grande CAD FILENAME: SCALE: DATE DRAWN: PLOT DATE: December 10, 2013 SHEET OF JOB NUMBER 4 5 5200368848 Panel Power Calculations - PAD -4 Panel ID: P #1 NAC ID --- > V1 Project: Milliamp Units V2 Part Number Description QTY Unit Sup Unit Alarm Total Supervisory Total Alarm PMI Person Machine Interface 1 230 230.0 230.0 230.0 2 PSC-12 Power Supply /Battery Charger 1 150 150.0 150.0 150.0 2 5 Active Relays 0 20 20.0 0.0 0.0 1 PSX 12 Power Supply Extender 0 170 170.0 0 0 0.0 2 MLC Device Loop Card 3 145 145.0 435.0 435.0 2 NIC-C Network Interface Card 1 120 120.0 1200 120.0 Rehab RPM Remote Printer Module 0 150 150.0 0.0 0.0 EXISTING BASE JOB # N/A ZJC-4A Zone Indicating Card 0 153 153.0 0.0 0.0 PLOT DATE: ZJC-8B Zone Indicating Card 2 155 155.0 310.0 310.0 9 ZAC -40 Zone Amplifier Card 40 Watts 0 150 150.0 0.0 0.0 0.981 ZAM -180 Zone Amplifier Module 180 Watts 0 280 280.0 0.0 0.0 14 14 Speaker Load Watts 0 0 0.0 0.0 0.0 3.07 AIC Audio Interface Card (External Input) 0 150 30.0 0.0 0.0 Voltage Drop DAC Digital Audio Card 0 100 100.0 0.0 0.0 Voltage Drop % DAC-NET Digital Audio Card with Network 0 230 230.0 0.0 0.0 Module Type LVM Live Voice Microphone 0 25 25.0 0.0 0.0 0.035 LPB Local Page Board 0 100 100.0 0.0 0.0 0.000 FMT Firefighter Master Telephone 0 150 150.0 0.0 0.0 0.000 0.000 Active Handsets 0 0 30.0 0.0 0.0 IYES TZC-8 Telephone Zone Card 0 280 280.0 0.0 0.0 Total Alarm Current 5,234 15 Minutes = 1,31 AH FCM-6 Fan Control Module 0 14 14.0 0.0 0.0 Acti\,e LEDs 0 0 1.0 0.0 0.0 LCM-8 LED Control Module 0 14 14.0 0.0 0.0 Active LEDs 0 0 1.0 0.0 0.0 SCM -8 Switch Control Module 0 14 14.0 0.0 0.0 ACtive LEDs 0 0 1.0 0.0 0.0 OCM -16 Output Control Module 0 14 14.0 0.0 0.0 Active LEDs 0 1 0 10.0 0.0 0.0 SIM -16 Supervised Input Module 0 20 20.0 0.0 0.0 Active Outputs 0 0 10.0 0.0 0.0 Active Relays 0 0 1.2 0.0 0.0 RNI Remote Network Interface 0 75 75.0 0.0 0.0 SSD System Status Display 0 200 200.0 0.0 0.0 FP -11 Smoke Det 93 0.00075 0.00075 006975 0.1 HFPT -11 Heat Det 4 0.00075 0.00075 000300 0.0 MSI -20B Pull Station 17 0.00100 0.00100 1 0.01700 0.0 TRI -86M Mini Module 0 0.00150 0.00150 0.00000 0.0 TRI -S Single Mod 0 0.00150 0.00075 0.00000 0.0 TRI -D Dual Module 1 0.00150 0.00075 0.00150 0.0 TRI -R Single Relay 0 0.00150 0.00075 000000 0.0 HCP Control Mod 0 0.00150 0.00075 0.00000 0.0 DFC -5128 DIGITAL DALER 1 0.08400 0.15400 008400 0.2 RCC-1F REMOTE ANNUCATOR 1 0.07500 0.30000 O C7500 0.3 Total Milliamps 1245.3 1245.5 PB -1191 Beam Detector 0 2.80 75.0 0.0 0.0 Total ZIC Cktst Speaker Outputs (in Amps) 0 0.00 0.0 0.0 0.0 Total ZIC Cktst 24 Volt Outputs (In Amps) 0 0.00 0.0 0.0 0.0 Total ZAC Ckts ZAC Audio Outputs (in Amps) 0 0.00 0.0 0.0 0.0 AUX in Supervisory Active only in supervisory (in Amps) 0 0.00 0.0 0.0 AUX in Alarm lActive only in alarm (in Amps) 0 0.0 0.0 0.0 Total Amps 1 1 245 1.246 Total Standby Current 1.2 x 24 Hours = 29.89 AH Total Alarm Current 1.2 5 Minutes = 0.10 AH Module Current Available 12.00 Total A -H Requirement 29.99 AH Module Current Required 1.25 Derating Factor 1.20 Module Current Remaining 10.75 Equals Min Battery AH 35.99 AH Minimum Batt Size 55 BAH CIRCUIT VOLTAGE DROP CALCULATIONS - PAD -4 Panel ID: P #1 NAC ID --- > V1 Start Voltage 20.40 Volts Mn Voltage 16.00 Volts Max Voltage Drop 4.40 Volts V6 V2 V3 V4 Aux AV Device Type AV Device Type Amps Total Total ZR -MC (75od) Strobe Wall 0.175 2 1 3 2 6 ZR -MC (15cd) Strobe Wall 0.064 2 5 4 2 8 8 ZR -MC -C (75od) Strobe Ceiling 0.200 1 4 1 1 3 7 ZR -MC -C (15od) Strobe Ceiling 0.069 2 1 U.L. Certificate ID No. 603961 -030 PRODUCT MANUFACTURER: SIEMENS 3 3 CH -MC (75 CD) Chime /Strobe j 0.175 2 3 3 3 13 11 NOT USED 0.000 Rehab 7350 Dairy Rd. Zephyrhills, Fl 33541 SHEET CONTENTS: 0 0 NOT USED 0.000 EXISTING BASE JOB # N/A E3 OTHERS SYSTEM SALES REP.: John Bourdeau PROJECT MANAGER: 0 0 NOT USED 0,000 PLOT DATE: December 10. 2013 SHEET OF 0 0 TOTAL DEVICES ON CKT 9 9 8 9 0 NAC Current (Amps) NAC Current (Amps) 1.166 1,569 0.981 1.378 1000 5.094 Wire Guage (awg) 14 14 14 14 14 I Resistance (Ohm /1000 ft) ** 3,07 3,07 3,07 107 3.07 I Estimated one way wire length (ft)* 150 165 180 200 0 Voltage Drop Voltage Drop 1 07 1.59 1 08 1.69 0 00 Voltage Drop °/z Voltage Drop % 5% 8% 5% 8% 0% V BATTERY CALCULATIONS - PAD Panel ID, P #1 Module Type Module Quantity Current Draw Standby Current Draw Alarm Standby Current Alarm Current Internal Power 1 0.035 0.140 0.035 0.140 lAmps Amps Total NAC Current 1 0.000 5.094 0.000 5.094 Amps < AUX not included above 1 0.000 0.000 1 0.000 1 0.000 I Am ps Am s p Does AUX drop out with no AC? YES IYES Total 1 0,035 1 5.234 JArrps Am ps Total Standby Current 0,035 x 24 Hours = 0,84 AH Total Standby Current 0.035 x 24 Hours = 034 AH Total Alarm Current 5,234 15 Minutes = 1,31 AH Total Alarm Current 4.084 15 Mnutes = 1.02 AH Module Current Available 9,00 Total AH Requirement 2.15 AH Module Current Required 5.23 Derating Factor 1.20 Module Current Remaining 3.77 Equals Mn Battery AH 2.58 AH Max Current per NAC 3.00 Minimum Batt Size 7 AH Module Current Available 9.00 Total A,H Requirement 1.86 AH Module Current Required 4 08 Derating Factor 1.20 Nodule Current Remaining 4 92 Equals Mn BatteryAH 2.23 AH Max Current per NAC 3.00 Mnimum Batt Size 7 BAH * Estimated wire length is from panel to end of line device ` Resistance for copper wire based on NEC Chapter 9, Table B. * ** Assign current draw for Auwllary output based on attached devices (relays etc,) If installed, configure door holders to drop out during loss of A/C (no load on AUX) BATTERY CALCULATIONS NOT TO SCALE NAC ID V1 Current Allowed (Amps) 3.00 Current Calculated (Amps) 1.17 Voltage Drop 1.07 NAC ID V2 Current Allowed (Amps) 3.00 Current Calculated (Amps) 1.57 Voltage Drop 1.59 1 NAC ID V3 l Current Allowed (Amps) 3.00 i Current Calculated (Amps) 0,98 Voltage Drop 1,08 NAC ID V4 Current Allowed (Amps) 3.00 Current Calculated (Amps) 1.38 Voltage Drop 1.69 NAC ID Aux Current Allowed (Amps) 3,00 Current Calculated (Amps) 0.00 Voltage Drop 0.00 CIRCUIT VOLTAGE DROP CALCULATIONS - PAD -4 Panel ID: P #2 NAC ID --- > V5 Start Voltage 20.40 Volts Mn Voltage 16.00 Volts Max Voltage Drop 4.40 Volts WITHOUT WRITTEN PERMISSION OF SIEMENS BUILDING TECHNO- V6 V7 SPARE Aux Revision AV Device Type Amps Total ZR -MC (75cd) Strobe Wall 0.175 1 PROFESSIONAL ENGINEERS APPROVAL STAMP. 1 N LTO r;v,EERS 2 ZR -MC (15od) Strobe Wall 0.064 3 5 * No 32578 8 ZR -MC -C (75cd) Strobe Ceiling 0200 1 2 DESIGN ENGINEERS: CONTRACTOR'S NAME & ADDRESS: Siemens Industries, Inc, 3 ZR -MC -C (15od) Strobe Ceiling 0,069 1 3 Tel(813)261 -8700 Fax(813)890 -8055 Florida State EF License No. EF2000416 U.L. Certificate ID No. 603961 -030 PRODUCT MANUFACTURER: SIEMENS 3 CH -MC (75 CD) Chime /Strobe 0.175 5 4 4 Florida State EF License No EF2000416 U L Certificate ID No 603961 -030 13 NOT USED 0.000 and Rehab 7350 Dairy Rd. Zephyrhills, Fl 33541 SHEET CONTENTS: 0 NOT USED 0.000 El PER CONTRACT DOCUMENT EXISTING BASE JOB # N/A E3 OTHERS SYSTEM SALES REP.: John Bourdeau PROJECT MANAGER: 0 NOT USED 0,000 DATE DRA'NN: PLOT DATE: December 10. 2013 SHEET OF 0 TOTAL DEVICES ON CKT 10 9 10 0 0 NAC Current (Amps) 1.457 1,292 1.195 0,000 0.000 3,944 Wire Guage (awg) 14 14 14 14 14 1 Resistance (Ohm /1000 ft) ** 307 3.07 3.07 3.07 3.07 1 Estimated one way wire length (ft)* 150 165 180 200 0 1 Voltage Drop 1.34 1,31 1.32 0.00 0,00 I Voltage Drop °/z 1 7% 6% 1 6% 0% 0% 1 V BATTERY CALCULATIONS - PAD Panel ID: P #2 Module Type Module Quantity Current Draw Standby Current Draw Alarm Standby Current Alarm Current Internal Power 1 0.035 0.140 0035 0.140 Amps I Total NAC Current 1 0.000 3 944 0.000 3.944 Amps « AUX not included above 1 0.000 0.000 0 000 0.000 Am s p Does AUX drop out with no AC? IYES Total: 0.035 4.084 Am ps Total Standby Current 0.035 x 24 Hours = 034 AH Total Alarm Current 4.084 15 Mnutes = 1.02 AH Module Current Available 9.00 Total A,H Requirement 1.86 AH Module Current Required 4 08 Derating Factor 1.20 Nodule Current Remaining 4 92 Equals Mn BatteryAH 2.23 AH Max Current per NAC 3.00 Mnimum Batt Size 7 BAH ` Estimated wire length is from panel to end of line device * Resistance for copper wire based on NEC Chapter 9, Table 8. -Assign current draw for Aubllary output based on attached devices (relays etc) If installed, configure door holders to drop out during loss of A/C (no load on AUX) NAC ID V5 Current Allowed (Amps) 100 Current Calculated (Amps) 1.46 Voltage Drop 1.34 NAC ID V5 Current Allowed (Amps) 3.00 Current Calculated (Amps) 1.29 Voltage Drop 1.31 NAC ID V7 Current Allowed (Amps) 3.00 Current Calculated (Amps) 1.20 Voltage Drop 1 32 NAC ID SPARE Current Allowed (Amps) 3.00 Current Calculated (Am ps) 0.00 Voltage Drop 0.00 NAC ID Aux CurrentAll owe d (Amps) 3.00 Current Calculated (Amps) 000 Voltage Drop 0.00 THE DRAWING AND DESIGN HEREIN SHAD- NOT BE DUPUCATED, USED OR DISCLOSED TO OTHERS FOR PROCUREMENT OR OTHER PURPOSE (EXCEPT AS OTHERWISE AUTHORIZED BY CONTRACT) WITHOUT WRITTEN PERMISSION OF SIEMENS BUILDING TECHNO- LDGIES, INC.. FIRE SAFETY DMWN. ALL OTHER REPRODUCTIONS SHALL BEAR THIS NOTICE. R E V I S 1 0 N S No. Revision By Date OSHPD NUMBER: PROFESSIONAL ENGINEERS APPROVAL STAMP. FREIJO ENTERPRISES N LTO r;v,EERS as? S T/ "yp�'A CH FL 3341 5 - V4 f5� Vej � V ,E -mal. frel;og eatt.nT * No 32578 E RCC'E EnRFIJO„P.F�� tt^^NFER N .'2370. �� /S.RE�ED�6�q (�J l DESIGN ENGINEERS: CONTRACTOR'S NAME & ADDRESS: Siemens Industries, Inc, Building Technologies Division TAMPA BRANCH 8403 Benjamin Road Tampa, Florida 33634 Tel(813)261 -8700 Fax(813)890 -8055 Florida State EF License No. EF2000416 U.L. Certificate ID No. 603961 -030 PRODUCT MANUFACTURER: SIEMENS Siemens Indusliies, Inc, Building Technologies Division TAMPA BRANCH 8403 Benjamin Road Tampa, Florida 33634 Tel (813) 261 -8700 Fax (813) 890 -8055 Florida State EF License No EF2000416 U L Certificate ID No 603961 -030 J08 NAME & LOCATION (STREET ADDRESS) Zephyrhills Healthcare and Rehab 7350 Dairy Rd. Zephyrhills, Fl 33541 SHEET CONTENTS: INSTALLATION TYPE O NEW INSTALLATION 0 DESIGN /BUILD El PER CONTRACT DOCUMENT EXISTING BASE JOB # N/A E3 OTHERS SYSTEM SALES REP.: John Bourdeau PROJECT MANAGER: DRAWN BY: Guillermo Grande CAD FLENAME: SCALE: DATE DRA'NN: PLOT DATE: December 10. 2013 SHEET OF JOB NUMBER 5 5 5200368848