Loading...
HomeMy WebLinkAbout14-15318 r` , r CITY OF ZEPHYRHILLS 5335-8TH STREET (8is)�so-oozo 5318 FIRE ALARM SYSTEM PERMIT , �=a3=�::���:�:��:.�` =,.�PERMIT-INFORMATION ' ' LOCATION INFORMATION.� _'-��=°F� "� ��:"� Permit Number: 15318 Address: 7346 7348 GALL BLVD Permit Type: FIRE ALARM SYSTEM ZEPHYRHILLS, FL. Class of Work: FIRE ALARM SYSTEM Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 35-25-21-0010-08800-0000 Improv. Cost: 2,300.00 ' -w,�01NNER�INFO:RMATION�,_��:�=����>r�����`��`.3' Date Issued: 5/30/2014 Name: TOWNVIEW RETAIL LLC/CO STOLTZ Total Fees: 150.00 Address: 725 CONSHOHOCKEN STATE RD Amount Paid: 150.00 BALA CYNWYD PA 19004-2102 Date Paid: 5/30/2014 Phone: 610-667-5800 Work Desc: INSTALL FIRE ALARM- ROSS STORE n�:��CO'NTRACTOR S I`' ` APPLICATION FEES �. ' " �SPECIALTY ELECTRONIC S TEMS.IN FIRE ALARM 50.00 FIRE INSPECTION FEES 50.00 FIRE PLAN REVIEW FEES 50.00 � �p I ��� `-r t — / ` ' ' Ins ections Re ired �_` .=" FIRE ACCEPTANCE Final FIRE ELEVATOR RECALL Chapter 633, Florida Statutes,authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review, administrative fees,and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final � inspection shall be charged double permit fee per day of operation or a minimum of$100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." �� � • ���a.,:�..,� �. , �,;� CONTRACTOR SIGNATURE PERMIT OFFICER PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECIION CALL FOR INSPECTION - 8 HOURS NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT- 813-780-0041 ,/ 813-780-0020 Ciry of Zephyrhills Fire Fax-813-780-0021 � � Permit Application Date Received Phone Contact for Permit z - - - - -- �� �lo �-�___�__-.._.�_.�_,____..�._._.__�__._..�....z_.__-r.._=�_�.__�.��_�_�__:�_.�._:__�..__�_...�. ,�,�..�__�__,�.__�_._.__-----�.,.o..._ __�_r�,,.,�_..�.__.. Owner's Name (,�Z cvi✓ta ivitN Owner's Phone Number � � � Owner's Address Fee Simple Titleholder Name Titleholder Phone Number � � � Fee Simple Titleholder Address ��--•�_.._...-t-_.._. ---�_w._.__��_.__---._,.__._�..._..w......__.._.____..._�__..______��.,._-..-,.._---_.�___-..-___.___..,___....,. - � _W_____ ____._„.� _s, Job Address �J �� Y DL./� d',�6L� � '�`�L�°A � --�p�/�-��� P Lot# � � Sub Division Parcel# t��..=.._..._,.�....- - ��__�.V.....___ --...____��..,,.m,�_._._�..,�.w...w.._�_.�,��_�._.�.�_a_.___�__,�_..«....:�.�._.____,_��..._._.._........�__.._�---.�..�,-_.,...___.��.�.-..w._.�....._„__=.ti=.V, � Bio-Hazard Waste Storage-ANNUAL � Fumigation Tent � Comm Exhaust Kitchen HoodlDuct � Hazardous Material(Tier II or RQ Facility)AMNUAL � Controlled Burn � Hood Installation � Emergency Generator<30 kw � LP/Natural Gas-Installation � Emergency Generator>30 kw � LP/Natural Gas-AtdNUAL Sale � Fire Protection Maintenance-ANNUAL � Places of Assembly-ANNUAL t y emi �n t er Sprinkler � ❑ ❑ ❑ � Recreational Burn Fire Alarm � ❑ ❑ O � � Sparklers Hood Cleaning � ❑ ❑ ❑ � � Sprinkler System Installations Hood Suppression � ❑ ❑ ❑ � � Standpipes(Sprinkler Sys) � Fire Alarm Installation � Torch Roofing/Tar Kettle � � Fire Pumps � Waste Tire Storage ANNUAL � Fire Works � Flammable Application-ANNUAL L9� Valuation of Project � Fuel Tanks 0 Other: P'^':=�__�.._......_.....__"°._ _�..a....,a........m.�..,... �._..�.:—_..�...�..,y.....v......_....,....,..w.._�-:_,_,__..........._-«,...._.�_W._ ----._._.__.�...e..:... '-�..�_._e�...,....��... _- Contractor � Company Signature Registered Y/N Fee Current Y/N IAddress License# ELECTRICIAN Company Signature Registered Y/N Fee Current Y/N Address License# IIPLUMBER Company Signature Registered Y/N Fee Current Y/N Address License# MECHANICAL Company ' Signature Registered Y/N Fee Current Y/N Address License# OTHER r Company S �GJGi �' CL �2.1i�,1'c: t�s � Signature Registered Y/N Fee Current Y/N � Address / �/,rR, Z G,� Cr� G License# ��Q a Q �p t--- --_.w_�..,._----- -- _ __.._,_._.._ ------___--� ----- - --°--�- - ._� __..,�.._-....____.:�_,��.-�._-�_°--- ---.�..�___.,,�___..__.-__-- ----- _.._---..t_�.._�-- - Directions: Fill out application completely Owner 8 Contractor sign back of application,notarized(Or,copy of signed contract with owner) If over$2500,a Notice of Commencement is required(Mechanical work over$5000) Supply two(2)sets of drawings with applicable documentation Allow 10-14 days for review after submittal date. Parcel#-obtained from Property Tax Notice(http://appraiser.pascogov.com) 1� � � t�OTICE OF pEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restricilons" , which may be more restrictive fhan County reguEations. The t�ndersigned assumes responsibility for compliance with any r applicable deed restrictions, UNI.ICEMSED COMTFt�4CTdRS AMD CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contracfors ta undettake work,ihey may be required to be licensed fn accordance with state and local regula#ions. 1f the contractor is not►icensed as required by faw, both the owner and contractar may be cited for a misdemeanor vialation under state law. if the owner or intended contractor are uncertain as to what licensing requirements may apply for the intendsd work,they are advised to contaof fhe Pasco Coun#y Huilding Inspection I}ivisian—Licensing Section af 727-847- 8009. Furthermore, if the owner has hired a confractor or contractors, he is advised to have the contractor(s) sign portlons of the"contractor Block"of this application for which they will be responsible. If you, as the owner sign as the con#ractor,that may be an indicatian fhat he is no#properly{icensed and is not ent3fied ta permittEng priviieges !n Pasco County. TRI4MSPORTATIOPC IAflPAGT/UTILITIES ENiPR,CT A(dD RESOURCE RECOl/EftY FEES: The undersigned understands fhat Ttansportation fmpact Feas and Recourse Recovery Fees may apply to the constrttctian of new buildings,change af use in existing buildings, or expansiun of existing buiidings, as specified in F'asco County Ordinance number 89-07 and 90-Oy, as amended. The undersigned also understands,that such fees,as may be due,will be identfied at the time of permitting. lt is fctrther undetstoad that Tsansportation lmpact Fees and Resource Ftecovery Fees must be pa�d prlor to receiving a°certificate of occ�pancy"or final power re(ease. tf the ptojecf does not involve a certiflcete of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, ff Pasco County Water/Sewer Impact fees are due,they must be paid priar to permit issuance in accordance with app8cable Pasca Caunty ordinances. CfltdSTRiICTiON!.lEid U1t1N(Chapter 713,Ftor[da Sfafutes,as amendedj: tf ualuation of work is$2,5dQ.d0 ar more,i certify that I, the applicant, have been provided with a copy of the "Florida Canstruation Lien Law—Momeowner's Proteciion Guide°prepared by the Florida 17epartment of Agricuilure and Cansumer Affairs. If fhe applicant is someone other tfian tfie"owner",i certify fhat 1 have obtainec!a capy of the above rfescribed cincument and promise in good faith to deliver it to the"owner"prior to commencement. COh�T92ACTOR'S!OlflftNEit'S AFFlDAVlT: l certffy that a!1 the infatmatlon In thls applicatian is aacurate and that al!work will be done 3n compliance with all applicable laws regulating canstruction,zoning and land developtnenf. Application is hereby made to obtain a permit to do work and installatian as indicated. I ceriPfy that no wark or installation has commenced prlor to issuance of a permit and that all work will be perFormed to meet standards of all laws regulating construcfion, County and City codes, zoning regulafions, and land developmenf regulations in fhe jurisdlcfion. 1 aEso certify that I understand that the regulations of otFier government agencies may apply to the intended work, and that it is my responslbilfty to iden#ify what actions!must fake to 6e i�compliance. Such agencles inolude but are not limited ta: - Departmenf of Environmentat Protection-Gypress Bayheads, 1Netland Ateas and Environmentally Sensitive Lands,WatedWastewater Treatment. - Southwest Florida Water Management Distrlct-Wells, Cypress Bayheads, WeUand Areas, Altering Watercourses. - Army Corps of Engineers-Seawalis,Docks,tJavigable Waterways. - bepartment of Health & Rehabllitatfve Services/Environmentel Health Unit-Welis, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-P�sbestos abatemenf. - Federal Aviation Authority-Runways. t understand thaf the foilauving restricfions appty Eo fhe use of fiEl:- - Use of fill is not allowed in Ffood Zone°V°unless expressly permitted. - If the flll material is to be used in Flaod Zone "A", ft is understood that a drainage plan addressing a "compensa#ing voiume"wif[be submittsd af time af permitting which is prepared by a professionai enginesr licensed by the Sfate of Florida. - If the fill material is to be used in Flood Zone°A° in connection with a permitted building using stem wall consfrucfion,1 certiiSyy#hat fill wil!be used anly to f:l!fhe area within the stert�waEi. - If fllt material is to be used in any area, 1 eertlfy tfiat use of such fill will not adversely affec# adjacent properties. If use of fill is found to adversely aftect adjecent properties,the owner may be cited for vialating the condltions af the 6u1lding permit issued under the attached perrr�it applicafton,for lots less than one(1) acre which are etevated by fill,an engineered drainage pian is required. If I am the IsaGENT FOR T�VE OVN@dEIR,I promise in good faith to inform the owner a#the permitting conditions set farth in this affidavtt priar to commenc(ng construction. !understand that a separate permit may be required for electrical work, plumbing, signs, wells, poois, air conditioning, gas, ar other instatlations not speaitically inciuded in the appCicafion. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provistans of the techntca!cades,nor shati issuance of a permlt prevent the Buildirig Official from thereafter requiring a correction of errots in plans,consfruction or v�olatians af any codes. Every pem►It issued sfiall become invalld unless the work authorized by such permit is commenced within six months of permlt issuance,or if work authorixed by #he permit Is suspended or ataandoned for a period of six(6)months after the time the work is commenced. An extension may be requesfed, in writing,from the Building Offiiclai#ar a period not to exceed nlnety{90)days and will demonstrate just�iable cause for the extensian. If work ceases far ninety(90)consecutive days,the job is considered abandoned. �i/Ri�t�tl�iG TO OWt�ER: YOtiR F�4iLURE TQ RECORU A RlOTiCE QF CONf�iti!llEtdGETVlEtdT�HAY RESULT 1PI YOUR PI�YIIdG TWICE FQR IAflPROVEfWEPlTS TO YOUR PROPEffTY. IF YOU INTEPdD TO OBTAIiV FIidANCING,COPdSULT NUiT@�YOUR LEtdDER 042�td ATT MEY EFO E RECLfl2DIRlG YOUR OTICE OF C AAMEi�G MEPdT. FLORIDA JURAT(F:5.1S7. 3 t OVVNER OR AGENT CONYRAC70R � - Stt6scdbed and swam to{ affirsned}before me thts Su}�scxibed and swom to{or a rme )before me this by �Y Who is/are personally knawn to me or haslhave produced Who Is/are persanaily knavm to me or has/have produced asidentlficaBon. asldentification. Notary Public Natary Publia Commission No. CammSsslon No. Name of Notary typed,ptinted or stamped �Name at NoYary typed,printed or stamped a / , � �EE��l�R�ILL.� FIi�E E3�P��E�ff��[�T 6907 Dairy Road,Zephyrhills, FL 33542 FIRE SERVICE USER FEES � Occupancy No.• - Plan No.: Contractor: Business Name: Billing Address: Business Address: � O � , �� Tew �, s Business Phone No.: Billing Phone No.: Business Fax No.: Billing Fax No.: � Contact: Contact: PLAN REVIEW FEES INSPECTION FEES PERMIT FEE FALSE ALARM FEE 8 SitePlan WC Mnual ' N/C Sprinkler $50 1stAlarm N/C Muki-Family/Commeroial .06 sf 1st Re-inspection WC Standpipes 550 2nd A1ann 1�/C (Minimum Charge$25.00 2nd Re-inspection $100 Fire Pump $50 �3rd Alartn N/C � Plan Revisions DBL 3rd Re-inspection =.�250 oods �50 4th Alarm �100 4th Re-Inspection �500 're Alartn 350 5fh Alartn E150 SPRINKLER SYSTEMS (Business dosed untit LP Gas S50 6th Alarm $2pp 8 0-25 Heads $50 violado�s coReded) Natural Gas S50 noN c�wwcE a150 26 pius Heads $100 SPRINKLER SYSTEMS Fuel Tanks- Perracdc $50 STANDPIPE SYSTEM Hydro Undergrounds �45 Sparklers 5100 �Per Riser S50 Hydrost-atic Test �65 Persynem Fre Worfcs S500 FIREPUMP AcceptanceTest a45 persystem CampFire a25� � Per Pump a100 Hydrant Flow. $75 Controlled Bum �100 FlRE A1�1RM SYSTEM Hood/Dud $50 �0-25 Devices $50 IRE ALARM SYS1'EM Place of Assembly $50 �,nua� - 26 plus Devices $1 System Acceptance $ Fre Protec�io� $25 SUPPRESSION SYSTEMS ecalt Acxeptan �50 Flammable Application S50 �nnuat Wet $50 OTHER Waste Tife Storage �50 �,ua� Dry a50 Fire WaIVSmoke Watl �15 �wau Ge�erator<KW 5100 CO2 $50 LP Gas $25 Per�anic Generator>30 KW 150 Other $50 Naturat Gas $25 persysiem B'w-Hazard Waste 5100 � KITCHEN DCHAUST Fumigation Tenting $50 �Hood/Duds �50 Tent 10k10'orgreater $15 perter,t Torch PoUApplied S50 , OTHER FUe Pump . �45 Haz Materials 5100 �nnuai 8 LP Installauon pe�tank �550 Fire Suppression �30 � Fuel Tank Inshaliation a50 System Acoeptance (Per Tank) S50 E�aust Hood/Duct �30 �Natural Gas InsG�liation S50 Re-inspection DBL {Per System) (other than annual) �Spray Booth �50 �Inspedion scheduled DBL a and pncelled less than 24 hours Construction Insp. N/C � Emergency Vehicle A� $50 FALSE ALARM ----Pti4i�iS Ttj��-�—iNSP�Ci16N�{���11.�-------PERMi�-i�� fiAt--�•------._._ . GRAND TOTAL � Comments: Date:`('tb�.�� a2�_ .__.._..lnspecto�` - --� ..___...- --.�^_,_.___O .__..___n... __ _._. ... _.__..__,----.__.._. ._.� _� __ _ ,.._ _._...---.--__._. .___.�._�_.. _.,_..�....�__._...__. ...__.�.._..__....__.----------- nm �� : � � � • ' .,��'"��� - �:. ���C��...�'Y . � �:. .� r,... ��C�'�O1�IC ,=' ��. � _ `; — v3r� d �������,�IVC� LIC.# �F0001046 ������������` 37919 6�Aeat�er 11�����D�E CIY�� �A..�RID� �i3��l5 -��C 3a�-��1-60�5 S lJ�Illl I1'TAL: �I RE ALARIVe SY�T�f4/I � � SPRINKLER RISER� For: Tov►�n �/ie� Square 7330 l"own 0/iev� �quare Zephyrhill�, �L AC���COI�TR�L��A.JRITaI.�I2 AL�i�-CC�/�Fd��R►�N9-�A°i� OPEI�TOIZ� f � ' I •.•• � I3iaa1� e.e� ����� � �� • � ����� ���� :f :dR;_� ���lt�,��qgl�lCm �LIC.# EF0001046 �� �� �� � �'��1� �e�it�'uer PO�z�-D��ICAI'�', E�A.,O�I�� �ii�!S�5���C �5�-�2�1-60�5 Please be �c����E :l �'�'�t��G�"d'�'��`:���,su��+�t��i��� 5 i'n��f���2 /��5�6�5 �� �V:1.��'�(`�.�a�G cursory reviev� io ���s�:,r ,���.: c�r�tractor i� com�Tance with ' applicable fCN Sc`31E:ti1: ��i�I�J, !��I� il,��ie��J is not intended to ue a ir;al �up�;r;�val t�� k��e �:!bm;�t�d pians !1 �s the contracfor's sole r�� �ons�b°'��; lO EPnSU�E. '��i! �;�e ��iar��are in �� r i�i'C�lntc�i CE(1t i�Cili����' , complete cor��pii�nce �:�iii� �II app�ic�:��c: �l�F���,:A�es and /— � local ordinances. In ��,e ev�r�� t+��t �_. =i�er �xam�nat�on or site inspection reve��ls aTeas ofi ru�;-�.�:���ip±i7nce, it snalf be the contractor's sole responsiuili'ty, a:their so�e expen �to ���'� bring those areas in compiiance. The Cify assumes no responsibifity for the contractor's failure to be in compl an • ' with aU applicable NFPA Cades and local ordinan s. �r�,-rr�� 5f�.;� -----.-���� �. j,. �t��� _ /�9i�zt�.�d F�35c� ,�--- � .� P ,�,• .-- ��1�'��G� .�' `�, � � � — l=/a;.�.�t��� "� y .�.��`I �',�,c�� �_1 � . � a � I � �� j _ sy5��,,� s'�N�� ��z/'�' � ���� ������� S�5�n-� J�c,sS�_ i"7 Z. !'� v1 T3 In L�'J °� /t5 i.� ��i��!��sJ-{��vN v --�_ ��� —� /)')+/�„Gr�'` ��} �� •� �� , _ --� '�' --- /v���.L�r-'r>n-t !�'l! sC 1C'�/� a �"s C ��f�� -- ��"�e����,�� r���;� l � � ��ivll'�'I'Eb�"I.AI�1�S)Alt1.i���"sEIV!.�'�!',:'Jd'� .r /f'lt i�C.��� 1�1r`� .3��� ��nG lt� � ��d ZEP�-iYRHII,LS FIRE 1VdP,RSHAL'S�F'�ICE � I�at�: G � ^�ri���*,r: � e�CC CO ��L��� ���/-�°AF� -�A►°�'� ��EI��°��� I ; / � 9N1'�LLIG�NI' FIRE A►L�RIVI COI�TROL PAN�LS FX�350 SERIES �e��ur�� • Listed to UL 864, 9th edition , � Single Addressable SLC Loop that supports�60 or 126 addressable points � �� Points can be any combination of Addressable � � Sensors or Modules • Supports lonization Sensors, Photoelectric Sensors, -- Uariable Heat Sensors and Multi--Sensor(Heat/Photo) _ � Equipped with.a 2 line by 20 character backlit LCD display,numerical keypad and an integrated UDACT/ II Digital Communicator � Digital Communicator can be configured for DACT or UDACT mode of operation � Configurable via the front panel,PC Configurator,or remote dial up through the built-in modem • Sensors can be configured asAlarm,VerifiedAlarm, II Latching or Non-Latching Supervisory, Monitor and Trouble-Only ' .. - ^ Modules can be configured as Alarm, Latching �I Supervisory,Non-Latching Supervisory,Water Flow, Monitor, Trouble, Fire Drill Switch, Signal Silence �escriQ�tion Switch,Aux Disconnect Switch and Buuer Silence The FX-350 Series Intelligent FireAlarm Control Panels Switch are single loop addressable panels with support for up to ' Base panel is equipped with Four Class"B"(Style"B") . indicatin circuitswhichma b e confi ured as Class A 60 or 126 addressable points. The FX-350 Series panels � y � are equipped with a finro line by 20 character backlit LCD (Style"Z") using a Class"A"-signal converter module ^ Indicating Circuits may be configured as Silenceable display, numerical keypad and an integrated UDACT/ or Non-Silenceable for both signals and strobes 'I Digital Communicator. The FX-350 Series family also . guilt-in sync protocols for the following strobe includes remote LED and LCD annunciators. manufacturers: Mircom, Amseco, System Sensor, ' The FX-350 Series panels are ideal for both new and Gentex, Faraday and Wheelock ' retrofit applications. Designed for small to m,edium ° Relay contacts for Common Alarm,Auxiliary/Alarm ' commercial, institutional and industrial occupancies, (Disconnectable), Common Supervisory and these panels are powerful enough to meet today's Common Trouble installation demands. The FX-350 Series panels are ° Configurable Signal Silence Inhibit, Auto Signal � configurable by the keypad for onsite programming or by Silence and One-Man Walk Test ' a PC for both onsite and remote programming. Easy to ° SubsequentAlarm,Supervisory,andTroubleoperation install and simple to operate and configure,the FX-350 ' RS-��85 Interface for Remote LED and LCD Series panels enable the installerto configure the system Annunciators, to meet their specific requirements. • Interface for a Remote Trouble Indicator(RTI-1) • Two event history logs comprised of a 200 event The FX-350 Series panels are equipped with a 5.5 alarm log for alarm related events and a 200 event Amp power supply, auxiliary resettable smoke power general log for all other events supply(300mA max.),an interFace for a Remote Trouble ° 5.5 Amp Power Supply Indicator(RTI-1)and an RS-485 interface for remote LCD • Optional modules for additional intemal relay circuits and LED annunciators. and City Tie/Polarity Reversal • Optional trim rings for semi-flush mounting All FX-350 Series panels come complete with a red door, ,�. black enclosure,durable CAT 30 lock and key and space to mount up to 12 AH batteries. Optional trim rings are U` ���••<.. ��A available for"semi-flush mounting. aPP�o�ea S7010 ��65-1477'156 313-97-E CATALOG NlJN9BER e670 od NOT TO BE USED FOR INSTALLATION PURPOSES. � Mircom reserves the right to make changes at any time without notice in prices,colours,materials,components,equipment,specifications and models and also to discontinue models. . , ,, ' �ptional Adder E9llodules � , ',.... � •r�.�""� ��F .�-� ..v� . -' 4 � � ..I��►w, _ OCAC-304 Faur lndicating Cim.uiE C1ass"A"Canvertier Module PR�00 Polarit)+Reversal�City Tie Modute � The OCAC-304 cbnverts four Class "B" (Style "Y") output The PR-300 provides outputs for city box and polarity reversal c'srcuits on the FX-350 ta Class "A° (Sty}e"Z") circuits. The appiications.As a city 6e module the PR-346 provides an intet�ace C1CAC-304 is equipped with wire ieads ta connect to the FX- between the cantrol panel indicating circuits and a master box. 350 main board. . As a polarity reversal module the PFt-300 provides an intetf�ace betvreen the controi panel and a reverse polarity receiver. R�rnote Anr�tar�ci�$ors� . I , I , , , RAM-300LCDR Remote L.CD Annunciatar RAM-1016lRAM-1032 Remote LED Annunciatars The RAM-300LCDR provides LCD remote annunciation through The RAM-1016 and R,4M-1032 Remote LEDAnnunciatorprovide a 2 fine by 2Q character �CD dispiay. The RAM-304�.CQR ��Qr 32 points respectively af LED annunciatian. Both rr�odels � pravides cantrol switches for Sysfem Reset,Signa)Silence,Fire come standard with bi-coloured LECts which are automaticaliy Drill and Acknowledge as well as a numeric keyp�d to access configured far eitherAlarm(Fted)or Supervisory(Amber). The , the menu funcfions. The comman control functions can be annunciatars have inclicators forA.C.4n,Common Trouble and disabied on a per function basis. The RAM-300LGDR has LED Signal Silence and controls for System Reset, Lamp Test, Fire indicators forA.0 (Jn,Alarrn,Supervisory,Trouble and CPU Fail. Drill,Buzzer Silence and Signal Silence. In addition both models � The RAM-30QLGD cames complete with a red enciosure and a allow for the controi switches ta be dssabled on a per fianction CAT 30 Lock and key. basis. Both models mount in a BB-1001 R enclosure. �_�.. RAM-208RtFYAM-216R Remote LED Annunciatars The RAM-208R and RAM-216R provida 8 or 16 points respectively of LED annunciation. Both models feature bi-colaured LEDs which are auto-configurable for either Alarm(red)or Supervisary{amber}. The�ED annunciatars have indicators forA.C.On,Common Trouble and Signal Silence and control switches for System Reset, 5ignal Silence, Lamp Test and Buzzer Silence. The RAM-208R and RAM-216R are equipped with a keyswitch which allows for enabling and disabling af the Comrrzon Cantra2 functions.Bath madels are available in a red finish and mount in a 4-gang electrical box. �¢�derit�g Infc�rmatio� � Model ,Description FX-354 Series inteiligent Fire Alarm Gontrol Panels FX-350-60-DR Single Laap 60 Point Intelli ent Fire Alarm Contral Pane1 with buiit-in UC3ACT/Digital Communicator i FX-350-126-DR Single Loop 126 Point Intel�gent Fire Alarm Control Fanel with built-in UDACT/Digital Communicator - '� FA-300TR8 Black semi-flush trim ring for FX-35Q Series enclosures i Optionat Adder Moclules - OCAC-304 Four Indicating Circuit Class"A°Converter Module PR-300 Polarity Reversal/City Tie Module Remote Annunciatars FtAM-300LCDR Remote LCD Annunciator RAM-1016 16 Zone Remote LED Annunciator RAM-9632 32 Zone Remate�.ED Annunciator BB-1001R Enclasure far RAM-1016&RAM-1032 Annunciators I RAM-208R 8 Zane Remote LED Annunciator RANf-216R 16 Zone Remote LED Annunciatar NOT TO BE USEO FOR INS7ALLATIQN PURP6SES. /����`/ ��._ ,,�y,���, � Distributedby �� �l��.�� Canada U.S.A. 25 Interchange Way 4575 Witmer Industrial Estates Vaugha�,f}�taria L4K 5W3 Niagara Falls,NY 14345 . Telephone:(9d5)660-4655 Toli Free:(888)660-4655. Fax:(9p5)660-4113 Fax Toll Free.(888)660-4113 I I Web page: http://www.mircom.com Email: mail@mircom.com cqT.58�0 I iso 9oa�:z000 ;��: Rev.� REGl5TERED ��! c . , , �:� , o MET�4L FIF�E ALARIVI STATION . iViS-700 SERIES Feafiures _ • Single or Dual Action models . : • Single Stage or Dual Stage models • Key resettable � • Terminal connectors • Gold plated SPST contacts ' � - Optional auxiliary contacts ;�__:PULL-ITIREZ:�� PUSH;�BAR . - • High-gloss red enamel finish pU�l HANDLE-� • Plastic breakrod �� � Mounts on standard single gang box,Mircom's BB- � �i� 700 sur�ace metal backbox or BB-700WP weather ��' proof backbox MS-701 � �� ° Available in English and Bilingual versions Single Action Manual Station MS-710U Operation Dual Action Manual Station The MS-700 Series is operated by pulling the handle on DeSCrlp$lon the front of the station.The unit is reset by opening the , station with the key, placing the handle in the normal Mircom's MS-700 Series Manual Stations provide upright posi�tion and re-locking the station.On the dual manual fire reporting. These high quality, die-cast action models,the push bar rotates inward allowing the metal manual stations are available in either single Manual handle to be grasped in a one handed motion. or dual action configurations with SPST contacts and The MS-702 (two stage version) also provides a key terminal strip connections.The normally open contact, switch which is accessible after the handle has been which closes when the manual station is activated, is pulled. Operation of the key switch,when connected rated for 1 amp,30 VDC.The contacts are gold plated to a separate general alarm circuit, will initiate the to avoid the risk of corrosion. 2"d stage of a two stage alarm signalling system. The MS-700 Series Manual Stations are available in Spe�iflC2�tions many different configurations as either single or dual- The manual station shall be Mircom's MS-700 Series. action devices. Operating instructions shall be in raised English or The MS-701 is a single action, single stage manual English and French lettering and the unit shall be station. Model MS-710 is a single stage, dual action constructed of high quality die-cast metal and finished � manual station. The MS-702 (two stage) is similar in red enamel paint to provide quick identification. to the MS- 701 (single stage) except it contains an Pulling the handle shall initiate immediate operation of additional GeneralAlarm(G.A.)N.O.switch.Forsafety the alarm detection circuit. In addition, those stations reasons, the G.A. switch is only accessible after the installed in a two stage system shall come equipped with handle has been pulled. A special key is supplied an internal key switch designed to operate the 2"'stage with each unit. - alarm initiating circuit. All manual fire alarm stations shall be installed to comply with the Canadian Electrical All models are available with key resets, terminal Code(CSA22.1)and CAN/ULC-S524-01 Standard for connectors, SPST gold contacts and CAT-30 lock Installation of Fire Alarm Systems. Final acceptance and keys. The units mount on a standard single gang is subject to the local authority having jurisdiction. backbox, Mircom's BB-700 surFace metal backbox or BB-700WP weather proof backbox. ti� The MS-700U Series Manual Stations are listed for U` �IC' .,`�.,,�0,,...•; outdoor applications when used with the BB-700UVP. ` , S7005 S7005 7150-1477•1zs c�►-r-��.�c �unn�E� 515� NOT TO BE U5ED FOR INSTALLATION PURPOSES. Mircom reserves the right to make changes at any time without notice in prices,colours,materials,components,equipment,specifications and models and also to discontinue models. E � , ' Speci�i�atior�s � ° Switch Rating: 1 Amp @ 30 VDG,0.1 Amp @ 125 VAC , Manuai Station Dimensions: 4.9"H x 3.5"W x 2.0"D ' Calour: Red with r7ised white Ietters,white manua(bar with raised black letters. , 1'ypica6 YN6ri�� Diagrams . MS-701,MS-702 and MS-710 ��_7Q5 and MS-715 �� � . '�TO FIEXt STA770N PREVIpUS �ORENDOFIJNE STA710N DEVICE SPDTSwitch Terminal Block FROM {r TONBXi'SZATtQN R2CI � � t Prt�vtovs ��OR£(VOOFI.INE COM NO Q� STATION DEVICE Black � (MS-7020NLY) (h1S-7020NLY) N�� a� SEE NOTES. Q� White N.O.KEYSWlTCH �� �5a02 ONtr SEE NOTES. _L �. , N.o.swircH ' NO Switch MS-747 and MS-70$ �Ui"f�C@ �OUIi� BaC{CbOX�S 5PDTSwitch#7 Terminal Block COM NO. .... Red ���.. Black ���� II+ BB-700 5urface Mount Backbax NC �� �� Dtmensions: White 5"M x 3.6"W x 2.0"D SPDT Switch#2 �� {OM NO Red SEE NOTES. �N� Black White . N,O.Keyswitch(MS-708 Mbdel Only) � � Black � , Black I J �� Na�s: BB-700WP Weatherproof � • Wire as shown so that supervision of connections is maintained Surtace Mount Backbox • Mount station to 2"x 4"x 2%<"ouHet box • Ma7cimum size:No.12 AWG Dimensions: • For Normally Open operatian,cut the NC wire 5"H X 3.6"W x 2.2"D • For Normslly Closed operation,cut the NO wire • Switches shown in the Station Ciosed position Ordering Inforimation � � Model Description MS-7q1 Single Stage Single Actian Manual Station (Bilingual) MS-702 Dual S#age Singie Action Manual S#ation(Bil3nguaf} MS-705 ` Single Stage Single Actian Manual Statian Gw one additional Farm"C"(SPD�Contact(Bilingual) MS-710 Single Stage Dual Action Manual Station(Bilingual) MS-715 Single Stage Dual Rcfion Manual Staiian ctw one additianal Form"C"{SPDT}Cantact(Bilinguat} Note.Add su�x"U"for English only models. MS-707 Singfe Stage Single Action Manual Station c/w 2 Form"C"Contaets MS-708 Dual Stage Single Action Manual Station c/w 2 Form"C"Contacts and Key Switch BB-7q0 Series 7p0 Interior Surface Maunt Backbox, Red Finish BB-700WP Series 7Q4 Weatherpraoi Surface Maunt Backbox, Red�inish NOT TO BE USBA FOR INSTALLATlON PURPOSES. �� ���m� pisTributedby� ��/�, � Canada U.S.A. 25 Interchange Way 4575 Witmer Industrial Estates Vaughan,Ontario L4K 5W3 Niagara Falls,NY 143Q5 Te[ephane:{905}660-46�5 Tal)Free.{$88}660-4655 Fax:(905)660-4113 Fax Toll Free:(888)660-4113 Web page: http:!/www.mircom.com Email: mail@mircom.00m CAT.5156 ' I50 9007:2000 ;i�� Rav.S REGI5TERED �? ; � �4��HA IN�'EL.�,IC�NT�►DC�RE�SAB�E NICl�UL.E� N�IX-1 t�0 S�RI�� � Featur�� �}~'����r;£,="'��� � Designed to meet a wide range of applicafians � '��::�;`M��,:...:'��'�' �. � � ��'� ���` For use with the FX-350 Series FireAlarm Control M..�...: ., • � :_.. - ,.��;� -- -— - - Panels .._ _ �'' ,u� e �,.�,�...�, • ^ Fast response time '%'Ri�yl,'1��,:��p':;�{: i�t. ',z t�' • Priority[nterrupt feature on monitor mociules MIX-1o1 P MIX-100P Monitor modules can be wired as a Class A(Style . e D}or Class B(Style B) �N� ,:: .,;4 � Each module can be addressed from 1 to 126 � ` "�� �'"'�� ° Eight position dip switch for address setting �y � �„�, ���.�» . �;=`=� � '_`�'#�� • Red light indicator ��-�: , �t: d.`F���.w ..._,.,.� �'��� a • Modules mount,in standard 4"junction box � M IX-'[QOS M IX-'t OOX �@SC 8'1�J$IOiI Mircom's Aipha Series lnte(ligent Addressab(e 9ntelligentAddressable Priority Bl�ini-iV�anitor Madules are designed to meet a wide range of �llodule(MIX-101�) applications. The monitor and control modules can The IntelligentAddressable Priority Mini Monitor Module be used#a supervise and activate sounders,strobes, provides an address for a group of UUULC �isted doar closers, pull .stations, waterflow switches, Normally Open (N.O.) initiating devices, such as heat conventional smoke detectors and more. An eight detectors, prajected beam smoke de#ectors; 4•wire pasition dip switch allows forthe address setting ofthe smake detectors, waterffow switches, manual pufl device and #he vviring class/style of the devices that stations, etc. wired in a Class A{Style D) or Class B � are connected fia the module. All modules mount in tSfY�� �) initiating circuit. The MIX-101 R is equipped a standard 4"x 4"x 2 1/8"junction box. wi#h a priority interrupt to provide a fast response to emergency canditions. The MIX-101 P has an In#elligentAddressable Priarity Monitor Module activated red LED. � {M!X-900t�} . The lntelligent Addressa�le Priority Monitor Module �ntelligent Atldressable Retay Modute(iUitX-100R) (MIX-100P) provides an address for a graup of UL/ The IntelligentAddressable Relay Module cannects to , ULC Listed narmally open {N.O.} initiating devices, the same[oop as the initiating devices and provides such as heat detectors, beam smoke detectors, 4- �� �solated sets of F'arm-C contacts ta control a wire smoke det�ctors, wate�'law switches, manual variety ofi narmally open ar normally closed cantact pull stations, etc. wired in a Class A (Style Q) or aPp�ications cuch as fan operation and door closures. � Class 8 (Style 8) ini#iating circuit. The M{X-1QOP The MIX-100R has an activated red LED which is equipped with a priority interrupt to provide a fast fotlows the state of the relay cantac#s. ; response to emergency conditions. The MIX-100P .:Tt�y has an activa#ecl red �ED. ��� :� U� ,°,.U�....� � ..�� S5434 55434 7150-1477�156 - GATA��G t�U119I�EF2 ���� NOT TO BE USEQ FOR INSTALLATION PURPpSES. Mircom reseives the righi to make cha�ges at any time withoui nafice in�rices,calours,materials,cornponents,equipmeni,speciftcations and models and also to discontinue models. (ntelligent AdcQressable Supervised Control Fault Isolator IVlodule (f�ilX-'100X) Module(M!X-100S) The M!X-100X Fault !solator Madule is used to The M1X-100S Contro( module provides supenrised pratect the systern against wire-to-wire shart circuits monitoring of wiring to signal devices that require on the analog loap. The modules should be spaced � an external power supply to pperate, such as horns, between groups of sensars or modules in a ioop to strobes, bells or speaker isalators. Canventional pratect the res# of the laop. In the event of a short signais wiD require a 24 VDG power source and circuit between any two fault Esolator modules, speakers wil(require an audia input. The red LEq wi(I both modules immediately switch to an open circuit illuminate when#he module is activated.The module condition ant! isolate any group of sensors between is capable af Class A (Styie Z} or Class B {Style Y} #hem. ihe remaining units on the circuit will continue supervision. to operate in a narmal fashion(must be wired in Class `A'or Style 6) Sp�cificatior�s General speci�icat9ons Operating Voltage 1G-28 VDC Operating Communication G1ass A(Sty(e D}or C(ass B(Styie B} Temperature 4°F tfl+155°F{-20°C to+70°G} switch selectable Hausing/Cover �hite Polycarbonate Relative Humidity 0°lo ta 95°l0(No condensation or icing} ���te Finish �IX-'i OOP and 6Ut1X-'101 P �IItX-100X Current Consumption 600 uA Current Consumptian 35�A at 24V Atarm Current 4 6 mA(LED on} Max.Line Current 1 Amp MiX-100P 4.0"W x 4.0"H x 1.3"D Lirte Resistance 0.2 ohm D�mensians M(X-101P 3.0"Wx2.0"Hx0.75"D Dimensions 4.0"Wx4.0"Hx1.3"D MIX-100P 3.0 oz.(85.8g) Vyteight 3.4 oz.{85.8g} Weight �v1IX-1d9P 1.5 oz.(42,6g.} ��x-�ao� �i�-�oo� Current Cqnsumption 1 mA Current Cansumption 250 NA Signals 24 VdG reguisted Ratings 2A�a 24VDC,4.5A @ 30VAC Saurce Pawer Speakers 70.7 V RMS Dimensions 4.0"W x 4 0"H x 1.3"D Ratings 2A�a 30VDG,0.6A @ 125VAG Weight 3.0 oz.(85.8g} Dimensions 4 0"W x 4.0"H x 1.3"D Weight 3.0 oz.(85.8g} �e�r�ering I�f¢�rma�i�r� Model Description - M(X-1ddP lnte((igentAddressable Priority Rlianitor Module MIX-101 P Intelligent Addressable Priority Mini Monitor Module M1X-1dOR (ntelligenfAddressable Retay Module M!X-100S IntelligentAddressable Supervised Control Module MIX-idOX �ault Isolator Module NOT TO BE USED FOR INS7ALLATION PURPOSES. � Distributed by �!�!�`, ���Q����o .,: Canada U.S.A. 25 interchange Way 4575 Witmer Industrial Estates Vaughan,Ontario L4K 5W3 Niagara FalEs,NY 143Q5 Teiephone:(905}860-4655 Tolt Free:(888)660-4855 Fax:(905)660-4113 Fax Toll Free.(888)660-4113 Web page: http://www.mircom.com Email: mail a�mircom,com ��` CAT.5675 ISO 9QQ1.20Q$ (a�s Rev.2 4EGISTEftED `�� ; � ALPH�4 INl°ELLIGENT�ADDRES��4�LE DEl°�CTORS MIX,3000 SERIES Fea$ures "��' '���'��_" Low profile design � ��� 0 =�F�=�'w -�:�:��`�"° • For use with the FX-350 Series FireAlarm Control • �-� �,� P=,.:��.. Panels �� • - �,�;����` =( ���,`� ' � ���:;f �;' r , � -���h • Fast response time `�<�,._ ���i" - - .•�; `_ ,;�:v P��:.._ � Automatic addressing with the MIX ADD card MIX-3000 MIX-3100 lonization Smoke Detector Photoelectric Smoke Detector ' o Variety of mounting bases �"�;� d �;° �=�' Ease of installation �;::�s�;���,� e=. _'_rx, itasf; <�^ :,sr; �.t:r,;:,z��%»,y�� • a`:.i-.-.Y'• �;: �,Xi".. I � l -- ^ Elegant, unobtrusive design �a ��6,v, y_._—_. ..,�y�9�<d•��ti �i='�!,^ - �1 �� ' rf5 Digital communications �� ��qr, 4 �� �� ...' o :: �?- J�' ���" � ;.�,5*.�F?��Iktiµa��� � � a;4-� ,iu��fi, � ' �� �r�,�' MIX-3200 MIX-3300 � Multi-Sensor Detector Thermal Detector Descri�tion Mircom's Alpha Series Intelligent Addressable Intellige¢�t Multi-Sensor Detector(MIX-3200) Detectors are designed to meet a wide range The Intelligent Multi-Sensor Detector is a photoelectric of applications. The detector's address is set in smoke detector with a supplementary thermal sensor. its base providing a convenient and trouble free TheMulti-Sensordetectorcombinesphotoelectricsmoke maintenance procedure. The detectors mount into a andthermalsensorvaluestoprovideenhanceddetection selection of base styles to accommodate installation performance and reduction of false alarms. Information requirements. from each sensing element is processed and conditioned , by an on-board advanced technologyASIC and digitally Intelligent lonization Srvioke Detector(MIX-3000) transmitted to the FACP as a single analog value The lonization smoke detector incorporates a comprised of the combined responses from both the unique duai chamber design to respond quickly and photoelectric smoke and thermal detection elements. dependably to a broad range of fires. The ionization detector is equipped with a red LED which flashes Intelligent Thermal Detector(MIX-3300) when the detector is polled and turns on steady when The Intelligent Thermal Detector utilizes state of the art the detector goes into alarm. (UL Listed} electronictemperaturesensetoprovidefastandaccurate temperature monitoring. The thermal detector features Intelligent Photo�electric Smoke Detector(MIX-3100) an adjustable termperature range that is configured from The Intelligent photoelectric smoke sensor utilizes the FX-350.Series fire alarm control panel. a unique optical sensing chamber that is designed ,_,,^: to sense smoke produced by a wide range of � I�('' combustion sources. The photoelectric detector ,-.0'. �� `" �+ ��.k`'�.� is equipped with a clear LED which flashes when ss2s5 S6965 the detector is polled and turns on steady when the �2��-�4���,3a (MIX-3000,MIX-3'00 rM�X-�,00 (MIX-3000J B MIX-3200) 8 MIX-3200) detector goes infio alarm. 'z'z-'4"�'3' ss2ss S7498 (MIX-3f00) MIX-3300) (MIX-3300J 7272-1477�142 ( (MIX-3200) CATAL�G �V U 1911B E R 7270-1477'139 �6 7 6 (MIX-3300) NOT TO BE USED FOR INSTALLATION PURPOSES. Mircom reserves the right to make changes at any time without notice in p�ices,colours,materials,components,equipment,specifications and models and also to discontinue models. i + � z' Ilr11X-ADD Atldress Card ,K��. �� A unique, patented addressing method provides simple, user friendly and accurate :,.. . ��t=;G,i.�. Fb"-1,�-� identification of the detector beation.A coded MIX AQD card is inserted in the base.This ��`�i`' � � �`:�=;'��� can then be read by anyAlpha Series detector once it is plugged in. Using this method, ��;��=::. � � � " `V��� all the electronic components are in the detector but the location information is held in 1�,;:�<1� _:;;':,��'. - ��.'�.,:.y . ���., .. r_ ;„t;-: the base.The N[IX-ADD card simpiifies and speeds up installatian and commissioning. � ;t�•.,-=':• „r . -�,:�w:lr. '.:';'•r;� 6^t� � ';.;£..��, Addressing errars during maintenance and service are eliminated. _ -�� ���� - x �pecificatio�s General �pecifica�ions Operating Voltage I6-28 UDC Operating C4mmunication Class A(Style D)or Class B(Style B) Temperature d°F to+155°F{-20°C to+7p°C} switch selectable Hpusing/Cover White Po(ycarbanate Retative Humidity 0%to 95°l0(No condensatian or icing) P�ate Fin9sh �iilX-3000 lonization Detector iVIIX-3200 Multi-Sensar Detector Standby Current 5Q0 uA Standhy Current 50Q}tA Atarm Current LED 3.5 mA Alarm Current LED 3.5 mA MIX-3100 Photaetectic �etector MI)C-3300 Thermal Detector Standby Current 400 UA i� Standby Current 5dd{�A Alarm Current LED 3.4 mA Alarm LED Current 3 4 mA Operating 131°F ta 194°F{>5°C to 80°G} Temperature Range �rdering Inf��ma�io� .Mode! Description MIX-3000 Inte�ligentAddressabie lonization Smoke Detector(UL Listed) M!X-3100 lntelligent Addressable PhofoeleCtric Smoke Detector MIX-3200 Intelligent Addressable Multi-Sensor Detector MIX-3340 intef(igentAddressable Thermai Detector MIX-ADD Address Card for MIX-3000 Series Intelligent Detectors NOT TO 8E USED FOR INSFALLATION PURPOSES. � Distributed by ���1l, ������,:., Canada U.S.A. 25 Interchange Way 4575 Witmer Industrial Estates Vaughan,Ontario l4K 5W3 Niagara Fa31s,NY 14305 Telaphone:(905)680-4&55 Toli Free:(888}660-4655 Fax:(9p5)660-4113 Fax Toll Free:(888)660-4113 Web page: http://www.mircom.com Email: mail�n mircom.com CAT.567s I50 900'1.2005 r'°`� Rev.1 REGISTERED 1',�;� � , ��1 ��� � _�x�� 1� � � Iiar� � �r j;�F .::==�;,, C: `"' ��° �, / �� ��.`y�j"yi�•,_s+��� �„ ( � ri.:,.; ���,? � d�,t��. `�, � � _ � �1��'���!.:'�-"F,V � '���'x ".I..:y�i:�?-y.__ .�}.- �r�c�c��►r ��lectalaie� �:�'; - � . rc;� � - � `� - 1'°�'��"'.5''�:!�� .{��yta� }. , � 7:." , ti,>''^" �i. �t,�,;j��� _ ��1'��ii�1'� 1'��►�'1'1;�9 � ���;=:�>�-�'`_ .-s._ �� 'wyz, �c:; �" �, "'�;,�`"a� `� 'S?:"1Y�} �~1 :��r+�be��, �r�� � f `��:��f��- :�' �� , ���, ��=�;�J ��.�.- -:� /i fN�►r� St�r�b�s for ��` - � � - .� ��� �,��.���,t� R , r'y/ 0 � (� � ��~�� - ���� ��i���l��tl�►�"1S ����rY.��Y:-==_ _ Y"���'�`�,,a.. _.,� SpectrAlert�Advar�ce audible visible notificatian products SPECT � are rich wifh featr�res gUaranfeed�Q cut insfal�afion times � � � �a � � � and maximize profits. �@�t1,11'@a - The apectrAiert Advae�ce s�ries affers ihe most versatile and � Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry. With white and red plastic housings,wail and ceiling mounting � Tamper-resistant construction options,and piain and F1RE-printed devices,SpectrAlert Advance p Automatic selection of 12-or 24-voit operation at 15 and can meet virtually any application requirement. 15175 candela � Field-selectable candela settings on wal!units: 15,15l75,30,75, Like the entire SpectrAlert Advance praduct line,wall-mount harns, p 95,1 i 0,115. 135, 150,177,and 185 strabes,and horn strobes include a variety of feafures that increase their application versatility while simplifying ins#aliation.All devices iI p Horn rated at 88+dBA at 16 volts feature plug-in designs with minimal intrusion into the back box, I o Rotary switch for hom tone and three volume selections � making insta8ations fast and foalproof while virtually eliminating , � Universai mounting pfate for wall units costly and time-consuming ground faults. • Mounting plate shorting spring checks wiring continuity before To further simpiify installation and protect devices from construction device i�stallation damage,SpecirAlert Advance utiiizes a universa{maunii�g plate , � Electrically Compatible with legacy SpectrAlert devices with an onboard shorting spring,so installers can test wiring o Gompatible with MD�sync module continuity before the device is installed. � Listed for ceiling or well mounting Installers can also easily adapt devices to a suit a wide range of _ application requirements using fie(d-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rokary swikch for horn tones with ihree voiume selections. Agency Listing� SIGNALING :�t �L FM `�'EA .O• , a roved 7125-165?:786(indo9r,tiobes) LISTEA arraove0 Pp �t25-1fiS3:188(no�^slrobes. S4074{cNmes.ham ilo:es,^,orns) 3625572 McAd62-05•E chime strcbee; E55f2{st'CbeS} 7'3b•16$3'S&4(hR'n5,ph��-CS} � SpectrAt�rt�clv�nce�pecificatio�� i - , General SpectrAlert Advance horns,strobes,and horn strobes shall mount ta a standard 4 x 4 x 1�/-inch back box,4-inch octagon back box,or double-gang back box.Two-wire products shal!also mount to a single-gang 2 x 4 x 1718-inch back box.A unlversai maunting piate shall t�e used for mounting ceiling and wa11 products.The notificatian appliance circuit wiring sha(I terminate at the universal mounting p(ate. Also,SpectrAlert Advance products,when used with the Sync•CircuiY"Module accessory,shall be po�vered from a non-coded notification appliance circuit output and shal!operate on a nomina!12 or 24 volts.When used wiih tt,s Syne•Gircuit Module,12-volt-rated notification appiiance eircuit outputs shal(aperate between 8 and 17.5 volts;24-vait-rated notification appliance circuit outputs shal�operate between 16 and 33 volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DG or full-wave rectified unfiitered poever supp}y Strabes and horn sirobes shail have field-selectabie candeia settings includ3ng 15,1517b,30,75,95,110, 115, 135. 150, 177,and�85. Strobe The strobe shaii be a System Sensor SpectrAlert Advance Madel listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for vlsibie signaling app(iances,flashing at 1 Hz over the strobe's entire operating voEtage range.The strobe light sna(1 consist af a xenon f(ash tube and associated lens/reflector system. Horn Strobe Cambination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed ta UL 1971 and UL 464 and shall be approved for fire protective service.The harn strobe shall be wlred as a primary-signalir�g notificatian appliance and compiy with the Americans with Disabilities Act requirements#or visible signaling appliances,flashing at 1 Hz over the strobe's entire operaiing voltage range.The strobe light shall consist of a xenan flash tube and associated lenslreflector system.The horn shall have three audibility options and an option to switch between a temporal three pattem and a non-tempora!(continuous)pattern.These options are set by a multiple pasitit�n switch.On#aur-wire products,the strobe sha((be powered independently of the sounder.The hom on horn strobe models shail operate on a coded or non-coded power supply, . Synchronization Module The module shall be a System Sensar Sync•Circuit madel MC1L listed to UL 464 and shall be approved for fire protective service.The module sha0 synchronize SpectrAlert sirobes at 1 Hx and homs at temparal three.Also,whi[e operating ti�e strobes,the module shall silence the horns on horn strobe models over a singie pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize muitiple zones.Daisy chaining two or more synchronization moduies together wiEl syr�chro�ize all the zanes they car�trol.The madule shali not operate on a coded power supply. 3 Standard Operating Temperature 32°F io 120°F{d°C to 49°C} Humidity Range 10 to 93%nan-condensing Strobe F[ash Rate 1 flash per second Nominal Valtage Regulated 12 DC/FWR or regulated 24 DC/FWR' Operating Voltage h�angez 8 ta 17.5 V(i2 V nomir�a!}or 16 to 33 V{24 V�ominai} InputTerminat Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(inciuding lens) 5.6"L x 4 7"'W x 2.5"D(142 mm L x 119 mm W x 64 mm D) Horn Dimensians 5.6`�x 4 7`"W x 1.3"'D{142 mm L x 119 mm W x 33 mm D) Wall-Mount Back Bax Skirt Dimensipns(BBS-2,BBSW-2) 5.9"L.x 5.0"W x 2.2"'D(151 mm L x 128 mm W x 56 mm D) Wafl-MoecntTrim Riu�g Dimensians(sold as a 5 pactc}{TR-HS,i'RYV- 5.7"�x 4.8"W x 4.35"'D{145 mm L x 122 r�m W x 9 mm D) HS} Nates: 1.Fuli Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only fpr 15 and 15/75 cd. .�V�500'o0t � -- I UL Current Draw Dat� ea- 0 � � 8-17.5 Volts 16--33 Volts 8-17.5 Volts 16-33 Volts Canclela DC I�WR DC FWR Sound Pattern dB DG FWR DC FWR I Standard 15 123 128 66 - 71 Temparal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 � Range 30 NA NA 94 96 Temporal �ow 38 44 44 48 I 75 NA NA 158 153 Non-temporal High 57 56 69 75 �� 95 NA NA 181 1?6 Non-temparaf Medium 42 50 60 69 �i 110 NA NA 202 195 Non-temporal Low 41 44 50 50 �15 NA NA 210 20� Coded High 57 55 69 75 � High �35 NA NA 228 207 Goded Medium 4A 59 56 69 Candela 150 NA NA 246 22Q Coded Low 40 46 52 50 �a��� 177 NA NA 281 251 185 NA NA 286 258 � � Q.- o. .• . 8—i7.5 Voits 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 710 115 Tempora!High 137 147 79 90 107 1�6 '!94 212 218 Temparal Medium 132 144 69 BO 97 157 182 207 270 Temporal�ow 132 143 66 77 93 i54 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Niedium ' 133 145 75 85 102 163 �87 247 216 Nan-Temparai L'ow 13i 144 68 79 96 156 182 20i 214 FWR Input Temparal Nigh 136 155 88 97 112 168 790 210 218 Temparal Medium 129 152 78 88 103 160 �84 202 206 I Temparal Low 129 151 76 86 i01 160 184 194 201 I Non-Temporal Nigh 142 18i 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 . 95 110 166 189 208 216 ' Nan-Temporal Law 132 154 8d 90 105 161 184 202 2i 1 � e .,- .- 16-33 Vatts 76-33 Volts DC lnput 135 150 177 185 FWR Input 135 150 177 185 � Temporal High 245 259 290 297 Temporal High 215 231 258 265 , Temporei�4ediurn 235 253 288 297 Temporal Medwm 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal Nigh 265 27d 303 3d9 Nan-'femparal High 233 248 27b 281 � Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporai low 238 25� 291 295 Nan-Temporal�ow 214 229 256 262 �iorn To�es andl �o�nd {�utput �ata ea- 0 � 8-17.5 i6-33 24-Voit Nomtnat Switch Vol4s Volts Reverberant Anechoic Positlpn Sound Pattern +3B DC FWR DC �1NR DG FWR DC FWR 1 Temporai High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temparal �ow 71 73 76 78 83 80 94 89 4 Non-Temparal High 82 82 88 88 93 92 100 100 5 Non-Temporal Msdium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 i01 101 8t Caded Medium 78 78 85 85 90 90 97 98 , 9t Coded Low 75 75 81 81 88 85 96 92 �Seitings 7,8,and 9 are not available on 2-wire horn strobes. AVDS�O607