HomeMy WebLinkAbout14-15336 !�
!�
CITY OF ZEPHYRHILLS
; `' ,. 5335-8TH STREET
�si3)�so-oozo • 153 6
BUILDING PERMIT '
°'�` apERMIT INFORMATION ` LOCATION`INFORMATION � �� � � �' - `
Permit Number: 15336/15337 Address: 7331 GALL BLVD
Permit Type: COMMERCIAL ZEPHYRHILLS, FL.
Class of Work: ADD/ALT COMMERCIAL Township: Range: Book:
Proposed Use: COMMERCIAL Lot(s): Block: Section:
Square Feet: Subdivision: CITY OF ZEPHYRHILLS
Est. Value: Parcel Number: 34-25-21-0000-00300-0020
� Improv. Cost: 10,600.00 ' OWNER INFORMATION " `� .."
Date Issued: 6/03/2014 Name: MERCHANTS STATION c/o PHILLIPS
Total Fees: 135.00 Address: 7331 GALL BLVD
Amount Paid: 135.00 ZEPHYRHILLS, FL. 33542
Date Paid: 6/03/2014 Phone:
Work Desc: INSTALLATION OF WALK IN COOLER & EQUIP-BREAKFAST STATION
CONTRACTOR S APPLICATION FEES
MAIN COMMERCIAL COOKI &REFRID MECHANICAL FEE 135.00
� � v
� ov
� b
� �1
� l
�
Ins ections Re uired
FOOTER 2ND ROUGH PLUMB MISC INSULATION CEILING
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80 (2)(c) when extra inspection
trips are necessary due to any one of the following reasons: a) wrong address b) condemned work resulting
from faulty construction c) repairs or corrections not made when inspections called d) work not ready for
inspection when called e) permit not posted on job site� plans not at job site g)work not accessible.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications Must Accompany Application.All work shall be performed in accordance with
City Codes and Ordinances. NO OCCUPANCY BEFO C.O.
�
ON CTOR SIGNATURE PERMIT OFFI R
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION — 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
�- — —
813-780-0020 City of Zephyrhills Permit Application Fax-a��-�so-oo2�
Building Department
'Date Recefved —� 2 �
Phone Contact for Permittin
Owner's Name � .� � �S Owner Phone Number
Ownel's Address (/ Q / L G Owner Phone Number
Fea Simple Titleholder Name Owner Phone Number
Fee Slmple Titleholder Address
JOB ADDRESS � L v LOT# �
5UBDIVISION PARCEL ID# 1� ��� DW'�C/D OG'�ii'/
(OBTAINEO FROM PROPERTY TAX NOTiCE)
WORK PROPOSED � N TALL�R REPAIR � SIGN Q Q DEMOLISH
PROPOSED USE SFR COMM Q OTHER
TYPE OF CONSTRUCTION Q BLOCK FRAME 0 STEEL Q
DESCRIPTION OF WORK I T GG I�O C/N /7 J G'V'
BUILDING SIZE SQ FOOTAGE� HEIGHT �
QBUILDING $ VALUATION OF TOTAL CONSTRUCTION
DELECTRICAL $ AMP SERVICE Q PROGRESS ENERGY Q W.R.E.C. ��y/j��j
� �r
QPLUMBING $ � � I
i(�
�MECHANICAL $ O. VALUATION OF MECHANICAL INSTALLATION ;�% i� IC�1-
QGAS Q ROOFING Q SPECIALTY Q OTHER a ���
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA QYES NO � Z' `S��P � 5�����
� n
/L�tdJ
�.y
BUILDER COMPAMY
SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N
Address License#
ELECTRICIAN COMPANY
SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N
Address License#
PLUMBER COMPANY
SIGNATURE REGISTER� Y/ N FEE CURRE� Y/N
Address � License#
MECHANICAL � OMPANY 'y � � F �/�f��/Jd� ��G,
SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N
Address License# � O�
OTHER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N
Address License#
Illllllltlllllllllllllllllllllllllllllllllltlllllllllllllllltllllll
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Fortns;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanilary Facilities 8 1 dumpster;Site Work Permit for subdivisionsAarge projects
COMMERCIAL Attach(3)complete sets of Building Plans plus a Life Safety Page;(7)set of Energy Fortns.R-0-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stortnwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
""PROPERTY SURVEY required for all NEW consVUCtion.
Directions:•
Fill out application completely
Owner 8 Contractor sign back of application,notarized
If over$2500,a Notice of Commencement is required. (A!C upgredes over$7500)
" Agent(for the contractor)or Power of Attomey(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (Front of Application Only)
Reroofs ii shingles Sewers Service Upgrades A/C Fences(PlotlSurvey/Footage)
Drlveways-Not over Counter if on public roadways..needs ROW
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions"
, which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the"contractor Block"of this application for which they will be responsible. If you, as the owner sign as the
contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IAflPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of
use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and
90-07,as amended. The undersigned also understands,that such fees,as may be due,will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or
final power release,the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713,Florfda Statutes,as amended): If valuation of work is$2,500.00 or more,I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the"owner',I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner'prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT. I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is
hereby made to obtain a permit to do work and instailation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
- Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands,Water/Wastewater Treatment.
- Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers-Seawalls,Docks,Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authoriry-Runways.
I understand that the following restrictions apply to the use of fill:
- Use of fill is not allowed in Flood Zone"V"unless expressly permitted.
- If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume"will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction,I certify that fill will be used only to fill the area within the stem wall.
- if fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one(1)
acre which are elevated by fill,an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,
� plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or
set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by
the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension
may be requested, in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate
justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF CO ME E ENT.
FLORIDA JURAT(F.S.117.03)
OWNER OR AGENT CONTRACTOR
' Subscribed and swom to(or affirmed)before me this Subscribed end swom to i ed be me thi
bY �'Z..�'�� by
� Who is/are personally known to me or has/have produced Who is/a ona y r has/have produced
as identification. as identiTicati
�
Notary Public
Commissian No. Commission No.
Name of Notary typed,printed or stamped Name of Notary ty d,�t � �r,ta�BEFiLY ANN STONE
:_� �! MY COMMISSION#FF081570
'''�'oFtio°''� EXPIRES January 25,2018
' (40�)3ge.p153 FloridallotaryServiCe.com
, --- _ .
� � Illlllllllllllllllllilllllllllllffllllllllllllllillllillllll �
2014058589 `
� 34-25=21=0000—.00300-0420
Pertnit No. Parcef iD No �O�
� - .A N�
NOTiCE OF COMM�WCE611ENT ..• .e•
State oi A�••
Florida c�,�tyar Pasco �m�
� .p s�o-
THE UNpERSIGNEO hereby gives notice that improVement wi�6a made to certsin reel propeRy,end"m saordance.with Chapter 713,FMrida Slafufes, �
the foQovdnB infocmatlon ia provlded Pn this Moece af CaaenenamenC � �
1. o��;puo�or�,op�cy:aa.�ia�„ar��n ro�4-2S�21-0000-�0300-0020 ' o~o
s+reetaadreu: 7331 Gall Ave. �
W�
2. 6eneral DesalpiEon at Improvement Replace roof top A/C Units,Perform Interior Builcl Out of Restaurant � ;i n
�..
v•
�o m�•
3. Owner Infotma�n or Lessee i�orcrtation if the Lessee mntratled Tor Ihe�nprovement: �!m O
Phillips Edison � `� a
� a
19501 Northi��C`�`Drive. Cincinnati OH �
Addcess �er cty sce�e �,
Interest In Property:
�
Neme ot Fee Shnple TiilehNder.
qt ddfetcnt irom Oxmer 9sfed sbove)
Address Ciiy State_
a, contrerinr._P�ObuIItU.S. IrtC -
- - _ ._ 4530-C��Ri�'nercia!_Way ___. . _.._..—SPrin9 Hilt_._.__ _____.._ �-� {_.. .. _- ---.•---- -
�`� 352.835.7995 �'h �e� 3��-a �
Coiitractors Tetephb�a No.:
• 5. Surery:
' Name
Address Clry - Stete �a`-
AmouMOf Bond:$ Telephone No.: O'�r�-
,�t.a
6. Lender: �in
Name W�"
��.a o
A
Address Ciry Shate f� m
Lenders Telephone No.: - �ii/N r
7. Parsons withfi tl�e State of Flodda.desigpated by the owmer upon whom notices w olher doaanents may be served as prnvfded_by �W 7
' Sectinn 713.13(1j(s)(7),Eloiida Stalutes ���
3 �
Neme � �
c�
�F.►o
Address G'ry State � �
TMephOna Number of Qesignated Person: .�y��
X
8. In eddi0on ta himself,the owner designates � ��+AO
tn receive e capy of the Uena's NoUce as Fuovided in Secdore.713.13�11(b),Floride Statutes. 3
7elephone Numbu of Person or En Desi ted Owner, � �
�Y B� bY �
� �
0
9, E�Iradon date W Notice of Canmencement(the expfratien date may not 6e before ihe canpletion ot constsuctio�and final payment to ihe �
conLactor,but�r'fl be one year[ran lhe date of recoM'ng unless,�g difterent date is spedfledj: �
WARNING TO OWNER: ANY PAYMENTS MADE BY 7HE OWNER AFTER THE EXPIRATION QF THE NOTICE OF COMh1ENCEMENT
ARE CONSIDEREp IMPROPER PAYMENTS UNDER CHFlPTER 713, PART 1, SECTION 713_13, FLORIDA STAN7ES, AND CAN
RESULT IN YOUR PAYfNG TWICE FOR 1NIPROVEMENTS TO YOUR PROPEftTY. A N0710E OF COMMENCEMENT MUST BE
RECOkDED AND POSTED ON THE JOB SlTE BEFO}2E THE FtRST INSPECTION, IF.YQU INTEND 70 OBTqIN FlMANGNG,•CONSULT-- —__.. _,,. .---_-- .
' ---- - -- - .,,.WITH YOUR LENDER OR`AN ATtORNEY BEFORE COMMENCINGWORK OR RECORDING YOUR NOTICE OF COMMENCEh1ENT.
Under pene�ry a(petjury,l dedare tAat I heVa tead ihe forogoing notice ut eommencement qr�d that the fads stated therain are true ta the bes!
of my knm�ledge and beGet
S7ATE OF FLORIOA !��/r l/'� �h "�.
COUNTY OF 1?RSCO �r y��/ c7�fYJ4�'�7
, Si �or l e , er's�Lessea's Authosized �
icetlDiredor/Parmer ger
�-7 Si s T
The faregoing insWmentwas adcnowledged belaa me thls!dey oi f i� 2Q��by �"�� �l/�` '
es /r�1.�9i��2 (type of euthaity.C.g..officet;trusteB.attomey in ied)for
( ot parry a ehalf oi whom instn�ment vras e0�ed)..
Person Knovm ! 1. i
Nty ❑gg Produced IdenUIIcaBon❑J Nahmy Signature � Ct �i
Type of Identilleadon Produced_ J J�'�1)PS� 1 +CQ�lS{�Namo(Pri�t)- �Y ICJI n� T'i�j�� �
.� .��;:��;"��, 81EPHANtE HALL
* * MY COS�,MlSSION#Ff 02d028
• EXPIRES:June4,2�17
ur''FOrrld�'�� BabedTlwBtdgetNoiaryServites
, wpdatelbr_�Jnoticecammencemen(„p W 53048
U �r
���,�;���,
�,, �,�a..�s���
.�„�'"'�'�:
L
City of Zephyrhills
BUILDTNG PLAN REVIEW COMMENTS
� � �ContractorJHameowner: ,f�``�� ����
Date Received: � 'Zt,��
Szte: � �`.�t ��~��j R�1 t��
Pezmit Type: L���'7�-�1 ����r n CG�j�''" l t�t tSjG"`�.`_ -
Approved w/no comments: Approved w/the below cornments: ❑ Denied w/the below comments: ❑
This comment sheet shall be kept with the permit andlor plans.
,����!� •
t����� �.���14
Kalvin Switzer—Pl xaminer Date Contractor and/or Homeawner
(Required when comments are present)
., � .� ,-
r. .
� - i • r
. � - � - � - -
SERVICE&INSTALLATION OF COMMERCIAL COOKING AND REFRIGERATION
PROPOSED CONTRACT
April 14, 2014
. Breakfast Station#6 LLC Quote#1411
7331 Gall Blvd. Walk In Cooler
Zephyrhills,FL
Main Commercial Cooking&Refrigeration Service will furnish and install one complete Walk In
Cooler as detailed below.
SCOPE OF WORK REFRIGERATION
Pull permit not to exceed $250.00 for installation of Walk In Cooler.
Provide and del�iver 1 American Panel Walk-in Cooler for outdoor use,without floor, including
refrigeration equipment,to job site measuring 5'10"x 7'9"x 7'2"high.
Refrigeration system will include 1 Pre-assembled outside refrigeration system:
1 medium temp, 1 phase, 1/2 hp,208/230 volt condensing unit
1 evaporator
Thermostatic expansion valve, sight glass, drier, solenoid valve,thermostat,winter controls, 35 degree
operation, five year compressor warranty.
1 30"x 75"flush mount infitting door
Cam-rise hinges,padlockable deadbolt handle, door closer, brushed hardware,programmable
monitoring system 100 with digital thermometer, door frame heater, vapor proof light and switch with
pilot light.
Receive unload, inspect and erect walk-in panels for outdoor use at job site.
Hang evaporator coils,provide and install drain line to outside of box.
Set remote air cooled refrigeration equipment on provided level slab.
1 REFRIGERATION PIPING SYSTEM INSTALL
Provide and install refrigeration piping, insulation,traps, fittings and hangers to provide a complete and
operational system per all plans and specification's provided to MAIN Commercial at the time of this
proposal.
This proposal is based on a total amount of feet per line run for 1 system, (both liquid and suction lines will
be defined as "1 run") and the total line runs for a112 systems shall not ezceed 25ft per run. "Runs" will be
calculated by measuring from the condensing unit to each evaporator and additional "runs" going to any
additional evaporators attached to a systems line run.
Perform nitrogen leak test at 300 PSIG.
Evacuate and Charge system. Start up and test for proper operation
SCOPE OF WORK PROVIDED BY OTHERS:
Any building roof, floor, and wall penetrations if reyuired.
Any required pitch pockets/gooseneck need for these penetrations will not be provided by Main Commercial
All required electrical work.
Any fire sprinkler work, if required by code.
Cont....
16705 Sc/:eer Blvd.Hudsoi:,FL 34667
Toll Free: 877-868-8660 Pl:one: (727) 868-8586 Fnx: (727) 868-8650
- r �, — s
�
I — 1 • I
. " a • -
SERVICE&INSTALLATION OF COMMERCIAL COOKING AND REFRIGERATION
This quote is based solely on information provided to Main Commercial as of this date. Any work not
listed in the scope of this quote is not covered under this quote and will require additional pricing.
All work to be performed during normal business hours
This proposal does not include overtime hours.
Overtime hours subject hours subject to additional billing
Differences in scheduling or unforeseen job site conditions may affect the quoted price.
Work is quoted to be installed in clean,prepared areas.
Purchase order accepting this proposed work must show quote# on paperwork.
INSTALLATION OF WALK-IN,PIPING FOR 1 REFRIGERATION SYSTEMS....$10,600.00
ALL INSTALLATION OF WALK-IN COMPARTMENTS AND REFRIGERATION SYSTEMS MUST
BE PERFORMED BY A FLORIDA STATE LICENSED CONTRACTOR#CMC1249884
Due to scheduling,Main Commercial must have approved and signed proposal returned to our office at a
minimum of 30 days prior to start date.
PAYMENT TERMS: 40%deposit
40% upon delivery
20%upon completion
Accepted By:
Title:
Date:
Main Commercial Cooking&Refrigeration Service
Bud Costello
President
bud.costello@maincomm.com
Thanks for this opportunity!
MAIN COMMERCIAL
visit our website at www.maincomm.com
16705 Sc/:eer Blvd.Hudson,FL 34667
Toll Free: 877-868-8660 Pleo�ie: (727) 868-8586 Fnx: (727)868-8650
er►ryhux,4 IT
GROUP A, SPRINKLED ALLOWED PROPOSED
COMMON PATH OF TRAVEL 75' 75 OR LESS
DEAD END CORRIDOR 50' 50' OR LESS
TRAVEL DISTANCE MAX. 250' 250' OR LESS
r fl' oo
k 1 36'TRI-
F - TEA'IALE TREYflJo
flftJft1LthUll
CN. ffl!LHLL! fl
3C RANGE W.LC. -1 \
29'-6 n� 1 I 45''0' 1 / ' � e
9cl �I Wu�
MDP Pkcn?aF�E w II t' 'i7'r Q
SINK S�J^>-27" ,,.1� 1 �� \� (�' ... ..�t-,
® ® Cb 11 �� �< �' �� T �'4 �� w- T2"JO
£ Q DISH '1
11 _____
V II
II
$ ®RAG!G c' I III o� III 5 oI III F III F
I I EXIT/EMERfi it x I �'+� i t u o 4.�
11 L1GNT LINJ� � v w� .o w I ` ml
II I I a I •I I �
cq
Q
e�J
W �W
4m T �h
TAR.
LIFE SAFETY PLAN
SCALE:1/4"=f'—O"
5 Zfl
BT
EL74L T FAN
LrFE
EEI4um FAN&LITE
BSCf,5'g '11N 47S
FAN Pm-om
FAN s LIT!PR!-WIRE
AOWT BETIC'TOR
O• RON MO ouD!
o
ffo OUTLET
Erao ounrr
$ mff
(3It4rIJTL
�$L, (4)WAr$''Flt
VY WAFER PROOF GVTLRf
W.P.
F1DOR LIT!
as -�•< e �� I' x-- , 14Qoxca JL�2 x3+ 'I 1 i �� 1 �1frfCACCCS'$
36.31• r - - � �I I ��- � I ���
r 4 i
I.� r � E1pCATEO'I ELOCA7EDI LOCATE I T �
� I
N(P NEP igBLE m
AIR AUO rR C'r;Gg
rc� INK AIN �AOTI j �' � J F W.N. WdTiR HUM
iLDGNT I
rm
1 — TELIEPHONE✓ACE
It EXIP/EMERG. a
S`+
tiN h
EXISTD G PANEL SCHMLE
3 ROOF TOP MIT M1 4 ROOF TIP UNIT►2
FREEZER 1� Ct, ti
TOASTER OVEN 4
WATER HEATER
A.R
3 2 2014
NOTE,ALL ELECTRIC EXISTOVO UNLESS 1 =1 —o
tpTED ANO CLOUDED.
ELECTRIC PLAN
SCALE:f/4"=f'—D"
Dr
a
EXITLVG SUPPLY EXISTING S'MAIN SP[<➢?ARI IRAE-- �.E
EI O CAP E%iTING MAIN
`CONNLCT'.INN'. TO ELS'1HG
�\ �AN]?ARt .!NE ANT TUPPLT
CONNECT TO EOISTI`.G SUPPLY
6=v IIl
[UT SLAG F, MOP
"UT 'L v LINE SIF
O 5REAl-E TRA". U ASHE
ST K FC
73_0•
T�^ 'w
A.R.
3/472014
1/41'—0
PLUMBING PLAN
SCALE:1/4"=1'-O'
or 5
ArroloMp' Jr
�!N I
�M.N I MIN.
m '
ZiI
CLEAR FLOOR &:
TUR?VING RADIUS
(FOR HANDICAP RESTROOMS)
SCALE: f,:1 1' O'
gti
� va
FTae
2-acv�coa ..
EDA RACK l NN L'O❑R 1 36•TRI g �� �LRID'uLE5 TEAId TAE:ES FEP IC7LI ! L
STM Q
'3 6u>T23' 3 NAKE MACH. L!i1L !LIILL _____
.. , ' s ,
_ G� I k,
If
I� of
11 a
r - PREP CABLE _N�
s�K if
�i` yi (. C/ �1
T AR ONN CT ❑ ISH r P. B "F II :• ,APP.pv ED�EXI TING n
R J) 0' ASNE d "- I I 1 II r \I If _'�
0
'06z+ SINKI1..I`z " l� < .�+. /��
DRAIN i �_ I I I iQ —�:•--
...___DLL
,a
--
FA-S-NR I �
NEW WALLS
NOTE.FIVAC PERMIT BEING FULLED
SEPARATELT BY BUILDING OWINE?
DROP GRIT CEILING
STEEL TOP CHgNNEL O
^Y V
x Cam'
km V1 '
Ti
y0
❑TE
DP`WALL %1 /:2'DIAMETER 1 O
L 66'MIN Y.IRR❑R F
SA'M1N. / GRAB SAES 1'-F' I.
t DG AB BAE NWALL
AfiT GRAN BAR- M1N
O —26 GAUGE 3 1/2'STEEL SUDS
STEE'- B➢TTDM CHAfMCL
CONL'LEAD 'I
-T.P H�L PER
PROPOSED INTERIOR T ALL SECTION iTh ! /
SCALE.
1U
1j2"=1'-0' °
—,� �rU�k Y.
BATHROOM DETAILS
FLOOR PLAN SCALE.f 2"=1'-0"
SCALE:1/4"=1'-O"
or 5 ,-r#
- ar
I !
E.,
rrar cz*rx te
'r1
317
ti
lttR
yry�.a ____
O
EMh
I C
Lx m t
i w o
a F
A.R.
3/2V20 14
1 =1'-0"
EXISTING FLOOR PLAN
SCALE.:1/4 = '—O"
0r 5 r
Breakfast S . .
7331 Gall Ave. Drafting, Inc.
Zephyrhills, FL 33541 12527 Spring Hill Drive Spring Hill,FL,34609
Phone-(352)688-2348 Fax-(352)688-1662
W W W.pardrafti ngi nc.com
CODE DATA BUILDING DATA
APPLICABLE CODES BUILDING USE :1uJ I I c
1. EXISTING FLORIDA BUILDING CUBE 2010
LEVEL 2 ALTERATION
EXIS11`�G MIXEDEPJANTS bUS:IvE:;S, '•1ER;=AI�JTILE. ASSEMBLY ,l
2. FLORIDA FIRE PREVENTION CODE, 2010 PROPOSED A-SEHBLY
3, NATIONAL ELECTRIC CODE, 2008
4. NFPA 101 (CHAPTER 13 EXIST. ASSEMBLY OCCUPANCIES) - �� a" - I/
OCCUPANCY CLASSIFICATION REg HYk. �"
'
GROUP A ASSEr•1BL° ✓'"'
PLUMBING FIXTURE CALCUALTIONS CONSTRUCTION TYPE
TYPE WE CDN--T �I,���
EXISTING SPRINKL EP SYSTEM 3 4 s L3
A—c ❑C CUP�PvI-Y rON—� P-RATE RJILII'�iCi 1U
FIXTURE COJI�T 58 MAX;.L OwEO RCO=LE) - ! I cC,
FAN, RE TAI RA" CONSTRUCTION DESCRIPTION ;,�.: N.
<r5 PLOP<E WATE.CLO ETE A 4'Op1ET GRIWING COUNTA,N �qy `R.
MAI E 2. f PER I PEP 20J- ; _ 'Y
FF MPL_ 2I 1 COF 1 I PER 206=1 N A ',CR+iC[SINK FLOOR T1 _
FRO VIGEG 2 ER PROVIL_L' 1 r LOOR EXIL\ TI,�I] I-DNCPETE SLAP }�Y
TO PATRMN
INTERIOR WALLS Ex,ST �`1 r
T .IN�ifvIE STEEL STUDS
L
EXTERIOR WALLS° EXISTINGBLOCK CONCRETE
ROOF: STEEL BAR JOISTS
+EXI'STI"d' F3UILDING SHELL
LOCATIONMAP *ALTERATION TYPE. LEVEL 2
SQUARE FOOTAGE CALCULATIONS
N.T.S.
TOTAL APEA CGFOSS' 1.5P2sgft
ASSEMBLY AREA, 1 '56EsgF't
- - SHEET I OF 5 - EXISTING FLOOR PLAN
LIFE SAFETY DATA SHEET 2 OF 5 - PROPOSED FLOOR PLAN
2010 FBC CHAPTER 8-TABLE,803.5 511EET 3 OF 5 PLUMBING PLAN
T- - SHEET 4 OF 5 - ELECTRIC PLAN
INTERIOR FINISH REDUIREMENTS BY OCCUPANT
GRDUP A SPRINKLED SH�K,a,:N
EET 5 OF 5 LIFE SAFETY PLAN
VERTICAL EXITS AND PASSAGEWAYS ^B"
EXIT ACCECS CORRIDORS AND EXITWAYS B"
ROOMS AND ENCLOSED SPACES 'C"
r
m 2010 FBC-TABLE, 1004.1.1
MAXIMLIM FLOOR AREA ALLOWANCES PER OCCUPANT
T:�croi suuAly rmnv�v s;,m rbr>rrr ON sl«r AS".EMBLY READ 784s +t.15grross - 53 PEOPLE
ITCHE`J AND PESTRLTNPI AREA 74r,y}+ 1�Sr cs= = 4 PEOPLE
STORAGE AREA 37sa}ti30Og,oss = 1 PERSON
`-'L PEOPLE = S�
2010 FBC-CHAPTER 10
k+�.,rl,aslc,,I.r MEANS OF EGRESS RECUIFEMENTS
tirx41Pd Jtl5cph,l MO n
GROUP N. SPRINKLED ALLOWED PROPOSED JOB#-
N+i:xl m
COMMON PATH OF TRA`✓EL 75' 75' DP _ES _ City of Zephyrhills
PERMIT#
'a.ce.ra� lse�i, _,..mom. -�.e F� DEAD END CORRIDOR 50' 50' OR LESS
TRAVEL DITANCE MAX. ?50' .
�l OR LE:S
50x0.2" PEP OCCUPANT = 10.6° REQUIRED CONT.: ProBuilt U.S.
TOTAL EGRESS PROVIDED = 3dr_.v.34"=i0c
BUILDING WALL
GENERAL CONTRACTOR TO EXTERIOR
FURNISH AND INSTALL WALL PANEL
COUNTER FLASHING AND TO
PROVIDE ROOFING CEMENT
BEHIND AND OVER JOINTS.
UI 4'-2"W . SILICONE BEAD
x 7'-O"H #8 x 1" SM SCREWS •
tMEMI
JI RECOMMENDED 4" " GA. TRIM ROOF
x 6 1/4 x 14
BUILDING WALL STEEL ANGLE CONT. r MEMBRANE RAINROOF METAL STRIP
OPENING i(4*0 x 1 3/4"TAPCONS !9 #8x3/4 PPH TEK SCREW
24 O.C. WITH 1 5 8' EMBED°
IN CMU WALL (OR EQUIVALENT)
TRIM ANGLE
TEK SCREWS NEL DETAIL #2
10 sMs x z' 0 11 t/z" o.c. ROOF PANEL
BUILDING WALLWALL PANEL
HURRICANE ANGLE
DOOR ELEVATION MEMBRANE RAINROOF MEMBRANE RAINROOF 1/4" x 1 3/4"
FLASHED UP FLASHED DOWN 4"� ®TAPCOO.C.NS r-
-10" 12"-}-12"
--}
12"
(6) 3/8"0 THRU BOLTS
___ I ® 5 3/4" O.C. I I 9"�9I"-1
ISnNG CMU WALL I I
O O O O O
4'x 01/4'x 14 GA.
...- srEEL ANCLE caNr. ,
3/4'TAPCONS 0
W111 1 5/B°EMBED. o]" O
IN CMU WALL(OR EQUWALENT) �4 4„L
Q O O
:' 10 5Ms x 2"0 111/2'D.C. L O2 1/2" x 1 1/2' x
14 GA STEEL ANGLE
WALL PANEL 5 1/ (FLOORLESS)
J
3' x 1 1/2" x
14 GA STEEL ANGLE
2 1/2"x 1 1/2" s ROOF PANEL O *9" O (FLOOR)
3/8"a THRU BOLT 14 GA STEEL ANGLE 12*
IIJ ® CORNERS 6„ 2 WALL
PANEL CONS O 12" O.C. (FLOORLESS - AS SHOWN)
DOOR EMI O OR #12 TEK SCREWS O 9' O.C. (W/FLOOR - NOT SHOWN)
*9" OR
THRESHOLD 1 5/8" EMBED. I - - I�__
r 6 MESH WIRE 10 i41GAAxsEEi/AZNGLE O
3" MINIMUM REINFORCED 12 TEE SCREWS 91 9 a,C.
CONCRETE SLAB COMPACTED FILL
d e' ,' 1/4'P x 1 3/4°TAPCONS
EXISTING FLOOR k•" . 0 12^o.C.
O•
SECTION B - B SECTION M - MI X12 TEK SCREWS
9 O.C.
THESE PLANS CONFORM TO THE FBC 2010 ED.
El APPROVED SIGNATURE HURRICANE FASTENERS
THIS STRUCTURE HAS BEEN DESIGNED TO RESIST THE FORCES
❑ APPROVED AS NOTED PRINT NAME WITHOUT FLOOR AT BUILDING WALL O GENERATED BY 170MPH WINDS,EXPOSURE'C',CATEGORY I
rREDA
14 REVISED DOOR HINGING & REMOVE EVAP SECTION RB
El REVISE & RESUBMIT DATE
E DESCRIPTION REV. BY APP. BY
1) Please verify that door swing and location are correct. _ -
a AMERICAN PANEL CORPORATION
2) If this walk—in is to be installed in a depression, or quarry tile is to be applied to the interior, depression depths or tile I rAfFO'!JS! � rican Pan@I 58OO S.E. 78th St. Ocala, Florida 34472
thickness must be specified to insure proper door height. p Ph. (352) 245-7O55 Fax (352) 245-0726
3) All site preparation, floor or slab construction, plumbing, electrical connections (including control wiring) by others. iii ENGINEERING
4) &Electrical: 115-6O-1 required above latch side of each door, through ceiling, to operate frame heater and light. COMMERCIAL REFRIGERATION
5) Special note to General Contractor and his Sub Contractor for quarry tile or concrete wearing floors: the sheet metal panel C.T. TARNOWSKI PE #50662
facings may be susceptible. to staining due to excessive moisture created by hydration of concrete type materials- Therefore,
it is absolutely necessary that each room be properly ventilated. Also note that special precautions must be taken when using Engineering Business CA 00009677 ! BREAKFAST STATION - ZEPHYRHILLS, FL
muriatic acid due to effects hydrochloric acid fumes have on aluminum and stainless steel. DRAWN BY:
6) This drawing and information contained herein are the exclusive property of American Panel Corporation. It shall be returned , 7360 N.W. 5th Street Phone (954) 727 — 20271 4 RB DMM
to American Panel Corporation upon demand and shall not be reproduced in whole or part, disclosed to anyone else, or us c1 FOX 954 727 — 9644 PROPOSAL# JOB# SHEETwithout the written consent of American Panel Corporation. i Plantation, FL. 33317 ( ) =1 —0 227938 44054 2 of 2
-SPECIFICATIONS-
BOX HEIGHT: 7'-2" OVERALL (6'-10" INTERIOR)
CONSTRUCTION: FOAMED IN PLACE
NSF LISTED, STANDARD NO. 7
7'-9" INSULATION: 4";URETHANE, FINISHED PANEL
J
J UL CLASSIFIED FLAME SPREAD 20
_ CORE SMOKE DEVELOPED 350
co INSTALLATION: OUTDOOR
wc�
4" TYP. 7'-1" = z FLOOR: FLOORLESS W/HURRICANE CODE FLOOR ANGLE
J 0 (SEE DETAILS)
m DOOR HARDWARE DEADBOLT HANDLE W/KEYED CYLINDER LOCK, PADLOCK
M R/R DOWN & ACCESSORIES: PROVISION &
WIREINSIDE RELEASE
HYDRAULIC DOOR CLOSER
APC SYSTEM 100 TEMP. ALARM INCLUDING:
7 I 4 71,
10" DIRECT LINE VOLTAGE SYSTEM: 115Vac, 60Hz, 1 Ph
_ C OR F TEMPERATURE SELECTION
T 1'- " 5 DIGITS DIGITAL DISPLAY
AIR PROBE & DOOR HEATER PROBE, NTC SENSOR
o Z z LIGHT SWITCH & DOOR HEATER CONTROL
z 35 _ = Q z J PROGRAMMABLE AIR CAVITY HIGH & LOW TEMPERATURE ALARMS
O N a C 00 L E R I n 1E Q Z UJ
a PROGRAMMABLE AUTOMATIC LIGHT SHUT OFF
EXTERNAL ALARM RELAY
W/HURRICANE ANGLE B I B cfl � j O (115Vac, 60Hz, 1Ph 150W DIRECT POWER CONNECTION)
0 J INTEGRAL BUZZER ALARM
EA SON 0 < SON SCREW-IN FLUORESCENT VAPOR PROOF LIGHT FIXTURE
_________jw STRIP CURTAIN
0 - IY m 2 - STD. CAM RISE HINGES
.oI < _1'-4" ACCESSORIES: 5 - PCS. TRIM ANGLE
FLAT VINYL MEMBRANE RAINROOF
I 1 Z 10" METAL FINISHES: INTERIOR WALLS & CEILING - 26 GA STUCCO ACRYLUME
Q EXPOSED EXTERIOR - 26 GA STUCCO ACRYLUME
UNEXPOSED EXTERIOR - 26 GA STUCCO ACRYLUME
R/R DOWN Q EXTERIOR CEILING - 26 GA STUCCO ACRYLUME
ova REFRIGERATION: BY OTHERS LARG
EST THE DOOR PANEL ON THIS JOB IS 46" x 82".
NOTE: THE LARGEST ROOF PANEL ON THIS JOB IS 46.5" x 70",
CUSTOMER IS TO VERIFY THAT THIS PANEL SIZE
WILL NOT CONFLICT WITH ANY JOB SITE RESTRICTIONS.
8'-5" (MINIMUM SLAB) NOTE: CUSTOMER IS TO VERIFY ALL DIMENSIONS,
SECTIONS, DETAILS AND SPECIFICATIONS
ELECTRICAL DATA
= POINT OF ELECTRICAL CONNECTIONS. O
NSF
WALK-IN DOORS: 115v/10 - 350w*
*NOTE: ADD WATTAGE FOR EACH ADDITIONAL LIGHT FIXTURE IN ACCESSORIES.
THESE PLANS CONFORM TO THE IBC 2010 ED.
❑ APPROVED SIGNATURE
THIS STRUCTURE HAS BEEN DESIGNED TO RESIST THE FORCES
❑ APPROVED AS NOTED PRINT NAME GENERATED BY 170MPH WINDS,EXPOSURE 'C',CATEGORY I
❑ REVISE & RESUBMIT DATE
A I 5/9/14 REVISED DOOR HINGING & DELETED REFRIGERATION RB
R . DATE DESCRIPTION REV. BY'APP. BY
1) Please verify that door swing and location are correct. -'
AMERICAN PANEL CORPORATION
2) If this walk—in is to be installed in a depression, or quarry tile is ₹o be applied to the interior, depression depths or tile .r _ TNO!AS ' 1meClcan Panel 5800 S.E. 78th St. Ocala, Florida 34472
thickness must be specified to insure proper door height.
3) All site preparation, floor or slab construction, plumbing, electrical connections (including control wiring) by others. Ph. (352) 245-7055 Fax (352) 245-0726
ENGINEERING CUSTOMER:
4) 19Electrical; 115-60-1 required above latch side of each door, through ceiling, to operate frame heater and light. MAIN COMMERCIAL REFRIGERATION
5) Special note to General Contractor and his Sub Contractor for quarry tile or concrete wearing floors; the sheet metal panel PROJECT:
facings may be susceptible to staining due to excessive moisture created by hydration of concrete type materials. Therefore, C.T. TARNOWSKI PE #50662
it is absolutely necessary that each room be properly ventilated. Also note that special precautions must be taken when using THE BREAKFAST STATION - ZEPHYRHILLS, FL
muriatic acid due to effects hydrochloric acid fumes have on aluminum and stainless steel. Engineering Business CA 00009677 i DATE: I DRAWN BY: P.O.#:
6) This drawing and information contained herein are the exclusive property of American Panel Corporation. It shall be returned
5/7/14 RB/DMM
to American Panel Corporation upon demand and shall not be reproduced in whole or part, disclosed to anyone else, or used 7360 N.W. 5th Street Phone (954) 727 — 2027 SCALE:without the written consent of American Panel Corporation. Plantation, FL. 33317 Fax (954) 727 — 9644 PROPOSAL#: JOB : SHEET
3/8"=1 '-0" 22793B 44054 1 of 2