Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
14-15356
CITY OF ZEPHYRHILLS - 5335-8TH STREET (si3)�so-oozo 15356 BUILDING PERMIT � �`�PERMIT�=INFORMATION '�`��- � "�:���.�:: '� `.'P-. � Y�LO.CATION�INFO.RMATI;ON��"�����`���:����`� Permit Number: 15356 Address: 6520 FORT KING RD t.Q.r� Permit Type: COMMERCIAL ZEPHYRHILLS, FL. Class of Work: NEW CONST/COMM Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 03-26-21-0000-01000-0000 � .;,. _.,,.:.�,;-..-;��-- -- --- �- �� - , �.. Improv. Cost: 362,000.00 -.,=<.��.}-�-r,,OWNER�INFORMA��ION���� � - - �. Date Issued: 6/09/2014 } Name: SUNRISE PROPERTIES OF ZPH INC Total Fees: 4,267.65 Address: 6520 FORT KING RD Amount Paid: 4,267.65 ZEPHYRHILLS, FL. 33542 Date Paid: 6/09/2014 Phone: (813)788-1910 Work Desc: BUILD OUT (5 UNITS) -3 COMBINE/2 SEP- SEE SHEET CREDITS 9,275 sq ft • - t • �:- .� . - : . - � _ ,. . . _ _ �.,, . ..; �N��_;CONTRACTOR S �� - APPLICATION'FEES�� ._ -.. �� �`' _ � W�°��x� : : RYMAN CONSTRUCTION O LORIDA IN BUILDING FEE 1,138.50 ELECTRICAL FEE 260.00 MARTIN ELECTRIC PLUMBING FEE ` 0 MECHANICAL FEE 170.00 CHRIS BAHR PLUMBING W�ATF�R���R RES�4° 2,285.'90 FIRE PLAN REVIEW FEES 278.25 BAHR'S PROPANE GAS&A/C, INC. P�.z et�GJ %t�v2 a�.``�'_.� �� �F. . �� / �f \ v ` '�( ° / - 1 � �V� S,l't�- � � / � 1 ;�=�� b° - ; • Ins`ections Re uirecl� ,_J. , - .��£ x�"- _� ,�� �FOOTER 2NDf ROUGH PLUMB MISC INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80 (2)(c)when extra inspection trips are necessary due to any one of the following reasons: a)wrong address b) condemned work resulting from fauity construction c) repairs or corrections not made when inspections calied d)work not ready for inspection when called e) permit not posted on job site� plans not at job site g)work not accessible. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the.public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications Must Accompany Application. All work shall be pertormed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFO C.O. C NTRA OR I PERMIT OFFI R P IT E S 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER ► Y \ �.1�°`� ��iYr�, jG ' ����'� - PURCIiASE ORDER . ��- �•�°`� No. 00024243 ��� City �f �ephyrhills �.;`' ..��-t.� VENDOR: SHIP TO: BILL TO: Ryman Construction Inc City Hall � City of Zephyrhills 36413 State Road 54 5335 8th St 5335 8th St. Zephyrhills,FL 33541-2275 Zephyrhills,FL 33542- Zephyrhills,FL 33542 VENDOR NO. VENDOR PHONE NUMBER TERMS DATE REQUIRED DELIVERY DATE Ryman (813)782-0825 0 08/O1/2014 SHIPPING INSTRUCTIONS � (none) ITEM QTY U/M� DESCRIPTION/TASK PRD CODE ACCOUNT UNIT PRICE AMOUNT ] 5.00 ' ie 041-0000-343-3010 _ - 457.1800 2,285.90 �2e. urol, M��lez �) � � � ���- �1�3s� SUBTOTAL: 2,285.90 TAX: 0.00 SHIPPING: 0.00 TOTAL: 2,285.90- - TAXABLE: - No CONFIRMING: No 5����- -� .'. . . �� ' AUTHORIZED SIGNATURE SPECIAL INSTRUCTIONS: � i '� �v�e. �,�e.clL��r�-�.� e� ( r ��" ,V ZI \� � � IMPORTANT: OUR ORDER NUMBER MUST APPEAR ON EVERY INVOICE AND PACKAGE This order is given upon the representation and guaranty of the manufacturer or seller that no breach of any State or Federal Law or Regulation has occucred in connection with the manufacturing,processing,bianding,labeling or transportation of the merchandise herein mentioned. If such breach occurs or is charged by any legally constituted State or Federal authority,the buyer shall be entitled to rescind the order and retum the unused merchandise and shall also be held harmless by the manufacturer or seller against any penalty incurred and/or the cost of defense of any proceeding designed to penalize the buyer therefor. , 6520 Ft King Rd-9,275 sq ft build out 5 units o umn SQ. FEET PRICE MAIN OR LIVING: 9,275 $ 101.90 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 270,000.00 FEE SHEET $ 998.00 I ADDRESS $ 30.00 DRIVEWAY $ 30.00 BUILDING: $ 1,138.50 ELECTRICAL: $ 260.00 PLUMBING: $ 135.00 MECHANICAL: $ 170.00 �- -- SUB-TOTAL $ 1,703.50 TOTAL $ 1,703.50 SEWER: credits given — WATER: credits given IRRIGATION: $ - TOTAL: $ - WATER,METER:y$�"� 2,285.90 (5 meter @$457. ���'�-�!'�`��� IRRIGATI -IV METER $ - �L�.--�� vL�°�-�� � �- — - -DG� ,��f,��e��, ;�d` FIRE DEPARTMENT FEES �VI�,C�.Q,aS � PLANS TOTAL: $ 278.25 INSPECTION TOTAL: ' PERMIT TOTAL TOTAL: $ 278.25 PUBLIC SAFETY IMPACT FEES POLICE n/a FIRE 5% $ - TOTAL: $ � - SUB-TOTAL $ 4,267.65 PARK IMPACT FEES n/a SIF'S: n/a 100.0% $ - 1.0% $ - TOTAL: $ - T I F'S: credits given 99% $ - 1% $ - TOTAL: $ 4,267.65 Print Form CITY OF ZEPHYRHILLS UTILITIES WORK ORDER WATER ACCOUNT NO.: DATE: Jun 9,2014 OWNER/RENTER/BUSINESS:Sunrise MFG Int.Inc CONTACT PERSON: Ryman Roofing inc MAILING ADDRESS: 6520 Fort king Rd ��.{i.� pHONE NUMBER: 813-385-1322 Zephyrhills, FL 33542 EMAIL ADDRESS: SERVICE ADDRESS: 6520 FORT KING RD T OFF S�$1CIC ❑X WATER - ❑ SEWER INSTALL MEfER X❑ ❑ GARBAGE READ MEfER ❑ ❑X IN CITY � CHECK MEfER ❑ ❑ OUT CITY OTHER ❑ DESCRIBE OTHER: 3/4 WATER NUMBER OF UNITS DEPOSIT AMOUNT AMOUNT LAST BILL DATE MISC. CHARGE � �� p ' r Ci�����-` �i N' , Y�� METER: FULL 3/4 - �_ ,. , ?iv � IRRIGATION � � ' I I WORK COMPLETED BY&DATE ORDER TAKEN BY: JACKIE BOGES COMPLEfED ORDER GIVEN BY: � Revised 9/2010 � Print Form , CITY OF ZEPHYRHILLS UTILITIES WORK ORDER WATER ACCOUNT NO.: DATE: Jun 9,2014 OWNER/RENTER/BUSINESS:Sunrise MFG Int.Inc CONTACT PERSON: Ryman Roofing inc , MAILING ADDRESS: 6520 Fort king Rd (�(,rl�+--� PHONE NUMBER: 813-385-1322 Zephyrhills, FL 33542 EMAIL ADDRESS: SERVICE ADDRESS: 6520 FORT KING RD SHUT OFF SERVICE ❑X WATER - , ❑ SEWER INSTALL MEfER XO ❑ GARBAGE �' READ MEfER ❑ ❑X IN CIlY I CHECK METER ❑ ❑ OUT CITY I OTHER ❑ DESCRIBE OTHER: 3/4 WATER NUMBER OF UNITS DEPOSIT AMOUNT I AMOUNT LAST BILL �� DATE i � MISC. CHARGE vI` `��� , �f MEfER: FULL 3/4 / IIRRIGATION I WORK COMPLETED BY&DATE ORDER TAKEN BY: JACKIE BOGES COMPLEfED ORDER GIVEN BY: � Revised 9/2010 Print Form CITY OF ZEPHYRHILLS UTILITIES WORK ORDER WATER ACCOUNT NO.: DATE: Jun 9,2014 OWNER/RENTER/BUSINESS:Sunrise MFG Int.Inc CONTACT PERSON: Ryman Roofing inc MAILING ADDRESS: 6520 Fort king Rd �y���-(e PHONE NUMBER: 813-385-1322 Zephyrhills, FL 33542 EMAIL ADDRESS: SERVICE ADDRESS: 6520 FORT KING RD SHUT OFF SERVICE ❑X WATER ❑ SEWER INSTALL MEfER ❑X ❑ GARBAGE READ MEfER ❑ ❑X IN CITY CHECK MEfER ❑ ❑ OUT CITY OTHER ❑ DESCRIBE OTHER: 3/4 WATER NUMBER OF UNITS DEPOSIT AMOUNT AMOUNT LAST BILL DATE /! ; ��(.� I/ / � � MISC. CHARGE �` �� � v METER: FULL 3/4 IIRRIGATION WORK COMPLETED BY&DATE ORDER TAKEN BY: JACKIE BOGES COMPLETED ORDER GIVEN BY: Revised 9/2010 Print Form CITY OF ZEPHYRHILLS UTILITIES WORK ORDER WATER ACCOUNT NO.: DATE: Jun 9,2014 OWNER/RENTER/BUSINESS:Sunrise MFG Int.Inc CONTACT PERSON: Ryman Roofing inc MAILING ADDRESS: 6520 Fort king Rd j,Q;,�,-4—�� PHONE NUMBER: 813-385-1322 Zephyrhills, FL 33542 EMAIL ADDRESS: SERVICE ADDRESS: 6520 FORT KING RD SHUT OFF S RVICE ❑X WATER N SERVICE [� ❑ SEWER INSTALL MEfER X❑ ❑ GARBAGE READ MEfER ❑ ❑X IN CITY CHECK MEfER ❑ ❑ OUT CITY OTHER ❑ DESCRIBE OTHER: 3/4 WATER NUMBER OF UNITS DEPOSIT AMOUNT AMOUNT LAST BILL � i '���/ DATE � .� MISC. CHARGE � METER: FULL 3/4 IIRRIGATION I WORK COMPLETED BY&DATE ORDER TAKEN BY: JACKIE BOGES COMPLEfED ORDER GIVEN BY: Revised 9/2010 '� Print Form CITY OF ZEPHYRHILLS UTILITIES WORK ORDER WATER ACCOUNT NO.: DATE: 1un 9,2014 OWNER/RENTER/BUSINESS:Sunrise MFG Int.Inc CONTACT PERSON: Ryman Roofing inc MAILING ADDRESS: 6520 Fort king Rd �.(.�+� � PHONE NUMBER: 813-385-1322 Zephyrhills, FL 33542 EMAIL ADDRESS: SERVICE ADDRESS: 6520 FORT KING RD SHUT OFF ERVICE ^��` XD WATER TURN ON SERVICE C] ❑ SEWER INSTALL MEfER ❑X ❑ GARBAGE READ MEfER ❑ OX IN CITY , CHECK MEfER ❑ ❑ OUT CITY OTHER ❑ DESCRIBE OTHER: 3/4 WATER — NUMBER OF UNITS DEPOSIT AMOUNT AMOUNT LAST BILL G�� ; DATE �` r �t� � �• v MISC. CHARGE �/J �� V METER: FULL 3/4 IRRIGATION I WORK COMPLETED BY&DATE ORDER TAKEN BY: JACKIE BOGES COMPLETED ORDER GIVEN BY: Revised 9/2010 BXUV.U495-Fire-resistance RaUngs-ANSW L 263 __ � � 'AFJIIIJF f:FRTIFIC�TIRNC 1��REGT�RV U` ` �� �( �j� Design No. U495 \ BXUV.U495 Fire-resistance Ratings - ANSI/UL 263 Pa9a Rnttnm Design/System/Construction/Assembly Usage Disclaimer ■ Authorities Having Jurisdictlo,n should be consulted,in all cases as to the particular requirements covering the, installa.tion and use of UL Certified producEs, equipment, system, devices, and materials. ■ Authorities Having ]urisdiction should be consulted before construction. ■ Fire resistance assemblies and proilucts are developed by the deslgn submitter and have 6een investigated by UL for compliance with applicable requfrements. The published information cannot.always address every constcuction nuance encountered in the field. ■ W.hen field issues arise,, it is recommended the first contacC for assistance be the technical service staff pmvided by the product manufacturer noted for the design. Users of fire resi'stance assemblies are advised to consult the general Guide Information for each product category and eacfi grou,p of assemblles. The Gulde Information includes specifics conceming altemate materials and altemate methods of construction. ■ Only products which bear UL's Mark are considered Certffied. BXUV - Fire Resistance Ratings - ANSI/UL 263 BXUV7 - Fire Resistance Ratings - CAN/ULC-5101 Certified for Canada Caa C�r naral Tnfnrmatirin fnr Fiir-raaicYanrP Ratingc - ANSTfIII 7F,� Spa GPnpral Tnfnrmatinn fnr Fira Ra�tanrP Ratingc - C'A III G-S1 f11 C'r+rtifiarl fnr('anwrla - Desig n No. U495 March 19, 2014 Nonbearing Wall Rating—i or 2 HR. (See Items 5 and 7) When used in Canada it is required that a��matnr�a�c�ncluded witfiin the UL design.are also cUL certified. :°� i� i ��� ;�� - �.,� �.� `�_�� _ ......_... , .�_......._ �„-" ..,�..�......_... � _ .___.... .. :. _._=__..._..�_.__...`w�...._....:_......�__.__...._..�_.� �:.�...._.... , ........�:�: .'.'' .._..... ............__.... � - -._._�.�__.._..:.:.._�..�_�,' �........::,�:_:::,:..:.:�::.:.;.:�,.>� .�;. ,..::y.:.: . - ,. & . � . � � � �- . ... � - ... . �:_::._.,.,;:.:.�_... ......_.�:.:�' ..w���:� `.� �...:;..w.' _.__. ��a:�::.o,:�:�;�_:-° ���� ;:'. ��: �� - I . . , :F' . I . _. . .... . ..,_• ,,. ;_. ... i . .::.:... .. . .. •:::., .:.:•:... : .. :�^ ; � � - . � •` ;;+'�j.............}� .�``. - ....� .:. ...._.. ` .. ..\ ;� '� � `��I :< , � ; ., . : • : �,j ,; .�� ; ; ; '• : •. ; - -�• ,�.... -- -- --- - - ;.<,. - _ _ M����• � < -����_ ��__w.._..w�____.�..___ �.»l��iv. Yi.4frtii�J:'����n._.�_�_�i3���wA�Jnf'�w�nR�O�L�I� ��i � . -_. . - ..K>ilYi� .__�.�uw_._�_�w.r��.__�alri+� �• . • • • .. . . _ .. . . .... -• • ' - . ." . . .:..�' " • . . ' '" . . . . . . . . l ._ .. ". .: � . ' � .. . i.w.�w..._.�_w�_.u.._..._._ ..�n�..r—:.�..�.�:.� w�wnm�........w�n�._....�.. , .�. _ ........ __�._.._ ...��.u...��.._���w�.... w�.�M . .... . . ' . •�� •• ' ' .•I _._..___.__��.���.:.. .................�.........___..__.�........ �.�........�....'"'..._._._.....�::»•1�A'..:..._�'..::_[...��.Y.�.�....�..6.:i �-1�+��-Y� ■ L�JL �if�R A V A� http:l/dafabase.ul.com/cgi-binlXYV/template/LISEXT/1 FRAME/&howpage.html?name=BXUV.U495&ccnshorttitle=Fire�resistancetl��ti��$��.4 BXUV.U495-Fir�resistance Ratings-ANSUUL 263 ,: 1. Floor and Ceiling Runners- {Not Shown) - Channei-shaped runners, 3-5/8 in. wide (min), 1-1/4 in. legs, formed from No. 25 MSG (min) galv steel, attached to floor and ceiling with fasteners spaced 24 in. OC, � max. 1A. Framing Members*-Ftoor and Ceiling Runners- Not shown -.In lieu of Item 1 - For use with Item 2A, proprietary channel.shaped runners, 1-1/4 in. deep by min 3-5%8 in. wide fabricated from min O.OZO in, thick galv steel, attached to floor and ceiling with fasteners spaced 24 in. OC max. CALIFORNIA EXPANDED METAL PRODUCTS CO -Viper20ip9 Track MARINO/WARE,DIV OF WARE INDUSTRIES INC-Viper20TM'"frack PHILLIPS MFG CO L L C-Viper20T'"Track 16. Framing Members*-Floor and Ceiling Runners-Not shown - In lieu of Item 1 -For use with Item 26, channel shaped runners, 1-1%4 in. deep by min 3-5/8 in. wide fabricated from min 0.018 in. thick galv steel, attached to floor and ceiling w(th fasteners spaced 24 in. OC max. CLARKDIETRICH BUILDING SYSTEMS-CD ProTRAK DMFCWBS L L C- ProTRAK � MBA BUILDING SUPPLIES INC-,ProTRAK RAMSALESLLC- Ram ProTRAK SOUTHEASTERN STUD&COMPONENiS INC- ProTRAK STEEL STRUCTURAL SYSTEMS L L C-Tri-S ProTRAK 1C. Framing Members*-Floor and Ceiling Runners.- Not shown - In lieu of Item 1 - For use with Item 2C, proprietary channel shaped runners, 1=1%4 in. deep by min 3=5/8 in. wide fabricated from min 0.020 In. thlck, galv steel, attached to floorand ceiling with fasteners spaced 24"in. OC max. - TELLING INDUSTRIES L L C-V1per20TM Track 1D. Fr,aming Members*-Floor and Ceiling Runners= Not shown - In lieu of Item 1 -For use with Item 2D, channel shaped runners, 1-1/4 in. deep by min 3-5/8 in. wide fabricated from min 0.018 in. thick galv steel, attached to floor and ceiling with fasteners spaced 24 in. OC max. TELLING INDUSTRIES L L C-TRUE-TRACKT'" 2. SteelStuds-Channel-shaped 3-5/8 ln. wide (min), 1-1/4 fn. legs, 3/8 in. folded back retums,formed . from No. 25 MSG (min) galv steel, spaced 24 In. OC maz. 2A.,Framing 4Nembers*-Steel Studs- Not shown - In lieu of Item 2 - For use with Item 1A, proprietary. channel shaped steel studs, 1-1/4 in-. deep by min 3-5/8 in. wide fabricated from min 0.020 in. thick galv steel. Studs cut 3/8 in. less in length than assembly helght. Spaced 24 in. OC max. CALIFORNIA EXPANDED METALPRODUGTSCO -Viper20T'" MARINO/WARE,DIV OF WARE INDUSTRIES INC-Viper20T" PHILLIPS MFG CO L L C-Viper20'" 2B.,Framing Members*-Steel S#uds-Not shown -In lieu of Item 2 = For use with Item 18;.channel shaped steel studs, 1-1/4 in. deep by min 3-5/8�in. wide fabricated from mtn 0.018 in.thick galv steel. Studs cut 3%8 in. less in length than assembly height. Spaced 24 in. OC max. CLARKDIETRiCH BUiLD=NG SYSTEMS- CD ProSTUD http://database.ul.com/cgi-bin/XYV/template/LISEXT/i FRAME/showpage.html?name=BXUV.U495&ccnshortiide=Fire-resistancetl�ti@�g��14 ' — - - --� - ---------•- - ----- ------ ---- -- - -�--- --------------- r--- BXUV.U495-Fire-resistance Ra6ngs-ANSI/UL 263 ` DMFCW BS L L G—P'roSTUD , MBA BUILDTNG SUPPLIES INC— ProSTUD RAM SALES L L C— Ram ProSTUD' SOUTHEASTERN STUD&COMPONENTS INC=ProSTUD STEEL STRUCTURA L SY5fEM5 L L C—Tri-S PrbSTUD 2C. Framing Members*-Steel Studs— Not shown - In lieu of Item 2 — For use vuith Item 1C, proprietary channel sliaped steel studs, 1-1/4 in, deep by min 3=5/8 in. wide fabricated from min.0.020 in. thick galy steel. Studs cut 3/8 in. less in length than assembly height. Spaced 24 in. OC max. TELLING INDUSTRIES L LC—Viper20T"' 2D. Framing,Members*—Steel Studs— Not shown -In Ileu of Item 2 — For use with Item 1D, channel shaped steel studs, 1-1/4 in. deep by min 3-5/8 in. wfde fatirlcated from min 0.018 (n. thick gaiv steel. Studs cut 3/8 in. less in length than assembly height. Spaced 24 in. OC max. TELLING INDUSTRIES L L C—TRUE-STUDT" 3..Batts and-Blankets*— (Optional, not shown) — Mineral wool or glass fiber batts partially or completely I filling stud cavity. See Batts and Blankets (BZJZ) category for names of Classified companles. 3A. Fiber,Spray,ed*—As ari alternate to Batts and Blankets (Item 3) — (100% Borate Formulation) —Spray applied cellulose materiaL The fi6er is applied with water to completely flll the enclosed cavlty in accordanc'e , with the application instructions supplied with the product with a nominal dry density of 2J Ib/ft3. Alternate Application Method: The fiber is applied without water or adhes.ive a.t a nominal dry density of 3.5 Ib/ft3, in accordance with tfie application Instructfons supplled wi#h the product. U S GREENFIBER L LC— IN5735 &INS745 for use witfi wet or dry application. IN5765LD and INS770LD are to be used for dry application only. 3B. Fiber,Sprayed*—As an alternate to Batts and Blankets (Item 3) and Item.3A- Spray applied cellulose insulation material.The fiber is applied with water to interior surtaces in accordance with the application instructions supplied with the product. Applied to com.pletely fill the enclosed cavity. Minimum dry density of 4.3 Pounds per-cublc ft. NU-WOOL CO INC—Cellulose Insulatfon 3C. Fiber,Sprayed*—As an alternate to Batts and Blankets (Item.3) - Spray applied celiulo"se fibe�: The . fiber is applied with water to completely fill the enclosed cavity in accordance with the application iristructions supplied with the product.The minimum dry density shall b.e 4,30 Ibs/ft3. INTERNATIO{IVALCELWLOSE CORP —Celbar-RL 4: Screws—Type 5 self-tapping screws, 1-1/4 or 2 in. long, {1 Hr) and 2-1/2 in. long (2 Hr). 5. Building Units*— For 1 Hr Rating— Nom 5/8 or 3/4 in. thick, 4 ft wlde, faced gypsum board panels with the faced side on the interiorwall cavity. Panels attached to studs and floorand ceiling runners with screws spaced 8 in, OC along the edges of the panel and 12 in. OC in the field of the panel. Joints oriented vertically and staggered on opposite sides of the assembly. MOMENTIVE PERFORMANCE MATERIAlS—Type CoreGuard. � 6. ]oint Tape and Compound— (Not Shown) —Vinyl, dry or premixed joint compound, applied in two coats to joints-and screw heads; paper tape, 2 in. wide, embedded in first la_yer of compound over all joi�ts. 7. Gypsum Board*— For 2 Hr Rating —Any 5/8 in.thick UL Classified Gypsum Board that Is eligible for use in Design Nos:L501;G512 or U305, Nom. 5/8 fn. thlck, 4 ft wide, gypsum board applied over exterior face of http:!/database.ul.com/cgi-bin/XYVftemplatefLISEXT/1 FRAME/showpage.html?name=6XUV.U495&ccnshorttitle=Fire-resistancetF�ti��g�'F�i..4 BXUV.U495-Fiie-resistance Ratings=ANSUUL 263 ., „_ . _ _ 1 Buildirig Unit(Item.5). Gypsum board to be applied vertically with joints staggered 24 in. from Building Unit (Item 5) and attached'to studs a'nd floor and ceiling ninners with screws spaced B tn. OC. ACADIA DRYWALLSUPPLIES LTD (Viaw C'IacaiFlratinnl —CKNX.R25370 AMERICAN GYPSUM CO(viaw Clacsifiratinnl —CKNX:R14196 ' BEI7ING NEW BUILDING MATERIALS PUBLIC LTD CO'���iPW�'laccifiratinnl —CKNX.R19374 CERTAIMEED GYPSUM INC�vtPw rlaccifirarinnl —CKNX.R3.660 C6CINC��/�Pw�'laccifiratinn�—GKNX.R19751 CODITINENTAL BUILDING PRODUCTS OPERATING CO�L L C 1����PW�'IacciFrahinnl —CKNX.R18482 GEORGIA-PACIFIC GYPSUM L L C K�/�Pw�'laeeifira+innl — CKNX.R2717 LOADMASTER SYSTEMS INC p��eu�����s���+���; —CKNX.R11809 NATIONALGYPSUM CO i�/�Pw C'IaSeifiratinT—CKNX.R3501 P.ABCO BUILDING PRODUCTS L LC�DBA PABCO GYPSUM��/�PW�'laccifiratinnl —CKNX.R7094 PANEL REY SA �vtPw C'lacs�f�rar�nnl —CKNX.R21796 SIAM GYPSUM INDUSTRY(SARABURI)CO LTD t���PW�'�accifiratinnl — CKNX.R19262 GEORGIA-PACIFIC GYPSUM L L C�UPw Glacciflrat�nnl — CKNX.R6937 THAI GYPSUM PRODUCTS PCL(�/�Pw�'laaalfiratinnr— CKNX.ft27517 I UNITED STATES GYPSUM CO (ViPw rlaeeifi�aHnnl —CKNX.R1319 ' USG MEXICO 5 A DE C V t���Pw�'IaccifiraFinnl —CKNX.R16089 *Bearing the UL Classification Mark I act u ri�tPr1 on 2014-03 19 ` 7 TPI'TTIG nf I IGP P."i9P�f1I1 OO 2014 UL LLC When ,the UL Leaf Mark is on the product;or when the word "EnVironment" is included in the UL Mark, piease search the L1L FnvimnmPnt riatahaca for additional information regarding this product's certificatlon. The appearance of a company's name or product In this database does not in itself assure that products so identified have be.en manufactured under UL's Follow-Up'Service. Ohly those products bearing the UL Mark should be mnsidered to be Certified and cove�ed under UL's Follow-Up Service. Always look for the Mark on the product, UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Informatlori, Assemblies, Construdions, Designs, Systems, and/or Certifications (files) must be presented in their enYirety and In a non-misleading manner, without any manipulatiori of the data (or drawings). 2. The statement°Reprinted from the Online Certiftcations Directory with permis§lon from UL" must appear ad�acent to the extracted materiaL In addition; the ranrintPtl materlal must include a mnvrinht notir.e in the follnWlnn forrri'at: "(c1 7'014 UI I I C"_ http://database.ui.com/cgHbin/XYV/template/LISEXT/1 FRAMEIshowpage.html?name=6XUV.U4958�ccnshorttitie=Fire-resistance-tfe'�ti��$�E�1.4 r � Jacqueline Boges From: Jacqueline Boges Sent: Monday,June 09, 2094 4:11 PM To: 'Holly Hopper' Subject: HENRI PC?HJOLAlNEN BP 6520 FORT KlNG Hey Holly. Let Kevin knaw he wil{ need to get with owner at 6S20 Fort king to get the address for this new built out {wili hold up the meters until that is turned in. Because the 5520#ort king address is not the correct address. Thanks Haily .lackie Boges-SCSS 813-780-0020 ext 3513 Faith makes things possible...Love makes all things easy Dwight L. Moody I � � � � � ADDRESSING DEPARTMENT GIS /ADDRESSING PASCO COUNTY GOVT. CENTER ' 8731 CITIZENS DRIVE, SUITE 310 � NEW PORT RICHEY, FL 34654 • � � Phone: (727)815-7154 http://www.pascocou ntvfl.net/ July 18, 2014 - To Whom It May Concern: F2e: Parcel ID # 03 26 21 0000 01000 0000 This is to confirm that the correct address for the above mentioned parcel ID# is: 6520 Fort King Road, Units 1-8, Zephyrhills, FL 33542 , Should you have any questions, please do not hesitate to contact this office. Sincerely, J a�n 2Uc�cPt�sn Pam Walton � GIS/Addressing Analyst �iry or�epnyrtuiis BUILDING PLA1�T REVIEW COMMEI�TTS Contractor/Homeowner: � /9�1�"Yl � Date Received: '�'� Site: �C� /� �Permit Type: ���-�..�<<�,�. i`� CrZ.L� Approved w/no comments:O Approved w/the below comments: ��- Denied w/the below comments: ❑ �`�J'�� 6�i �� Gc�� �1�'��'���'=a� 1�> � �, - - This coanment sheet shall be kept with the p�mit andlor plans. L� ,.. � � ��E� � � Bill urgess—Build' fficial Date Contractor d/or Hom (Required w comment present) 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received �('� �=�,� __ ���� Phone Contact for Permittin a f Owner's Name � U �F�- Owner Phone Mumber ���� �g��'��� Owrner's Address ls7�c�-� �"�' lJ�} �(� Owmer Phone fdumber Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address � JOB ADDRESS �� � �"�' �1//l� h� LOT# � SUBDIVISION PARCEL ID# �'� `"2� 'Z(,—ODC� � d 1 U DO � (��C��O (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW CONSTR e ADD/ALT 0 SIGN Q C] DEMOLISH �\� INSTALL REPAIR PROPOSED USE Q SFR Q COMM 0 OTHER TYPE OF CONSTRUCTIOfd Q BLOCK Q FRAME Q STEEL Q DESCRIPTION OF WORK ��fL= ���`C%��-� ��V11 (,(� 3 l•,�rvv 1/1'�' BUILDIPIG 51ZE SQ FOOTAGE "f��� HEIGHT � C v�� UILDING $ �Q a� VALUATION OF TOTAL CONSTRUCTION ELECTRICAL $ � D�� AMP SERVICE Q/PROGRESS ENERGY Q W.R.E.C. dLUMBING $ ' � J�� ZC� f�ll� -�� ` �S��s �-1 5�1� MECHAIVICAL $ VALUATION OF MECHANICAL INSTALLATION � 2� �� ,� 2 /l�D�- OGAS Q ROOFING Q SPECIALTY 0 OTHER � Z"�I ! ��\ �` FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA QYES N�� ��'^� ��� s-3b-�� BUILDER COMPANY b`�d.i�vJ C��S""C�(�.C�`l���� SIGtdATIDEtE REGISTERED / N FEE CURRE� Y/N Address � �' �j�� � ' (i�, �2 License# ELECTRICI N COfUIPANY ��`��f� ��CC.'�C,�� SIGNATUR REGISTERED Y/ N FEE CURRE� Y/N Address �, a � � License# �-�3 bal3'�3 PLUMIBER �C�G� COMPANY ��(�.,d� ��2 �l��i N SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N Address � � ��i-1,` ��D r � �!. `Ul l License# �� ����b 7' MECHANICAL COMPANY �A-�2 S l`�P-�S �! �' SIGNATUEtE REGISTERED � Y/ N FEE CURRE� Y/N Address License# C>Q � � �j OYHER COMPANY SIGMAYURE REGISTERED Y/ N FEE CURRE� Y/N Address License# RESIDEPITIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence instalied, Sanitary Facflities 8 1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(3)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Pians w/Siit Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compiiance SIGN PERflA1T Attach(2)sets of Engineered Plans. •'"'PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over 52500,a Notice of Commencement is required. (A/C upgrades over�7500) " Agent(for the contractor)or Power of Attomey(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTlNG V` �.(Front{of Application Only) - Reroofs if shingles Sewers ! Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW • . .._ � NOTICE OF DEED RESTRICTIO�lS: The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any appiicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILI�IES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as_required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions.of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pascb County. TRAYVSPORTATION IMPACT/UTILITIES.IMPACT AND RESOURCE RECOi/ERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery F�es may apply to the construction of new buildings, change of ��.,�ase in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable_Pasco County ordinances. CONSl'RUCTION LIEfV LAVII(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Floricla Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'SIOWNER'S�►FFID�►VIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. 1 certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill:� - Use of fill is not allowed in Flood Zone"V"unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. � - If the fill material is to be used in Flood Zone "A" in connectiori with a permifted building using stem wall construction, I certify that fill will be used only to fill the area within the stem�wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent ' properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE O1nINER, I promise in gvod faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically_included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to.violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A IdOTICE OF COMMENCEMENT MAY ItESULT IN YOUR PAYING TWICE FOR INIPROVEMENTS TO YOUR F'ROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT VNITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YO NOTICE OF COMII�ENCEMENT. FLORIDA JURAT(F.S.117.03) � - — _ __ OWNER OR AGENT CONTRACTOR Subscribed and swom to(or affirmed)before me th(s Subscribed and swom to(or afflr e e re this by Who ls/are personally known to me or haslhave produced Who Islar �cserrat�to or h /have produced as IdenUfication. � as identification. Notary Public U"�- '� " Notary Public ""' JACQUELINE BO Commission No. Com issi P(e�;"•"•� '•. :.: ommis o :;=. �'-��;a; Expires December 12,2018 Name of Notary typed,printed or stamped Name of No "' `�tl nrt �° , , _ Sunrise Properties Proposed Impact Fees(new addition) Based on 4977 total sq.ft.addition (Retail) 3318 sq.ft. Conditioned Water/Sewer Impact fee=$813.79 Public Safety Fee=$1,900.00 Transportation Impact Fee=$9,885.36 (Transportation Impact fee was based on 1,862 square feet,taking in consideration that portion that is exempt based on an accessory use to main use and square footage removed for back exit.). Proposed Impact Fees(if existing specialty retail building is removed) Existing building square feet=4852 Water/Sewer Impact Fee=$0 �f Public Safety Impact Fee=$45.00 '4` Transportation Impact Fee=$0 i� - Water Meters will be $309.70 per%inch meter required. Existing building would be required to be removed prior to build-out of any,unit in phase II to receive impact fee credits. (Public safety impact fee credit is only applicable if building is removed prior to Phase I construction). Yotal impact fees due during phase I construction would be$2,356.69 ��� :-b L�=�M-���-��, These fees are a close estimate and could be more or less at time of final plan approval/permitting. Y Q ■ o . f t[flt11H �r. f�i ���v � � ' %' , I � FEE SHEET COMM REs �. , .�_.� �.�z� t� �.`�� �.;� . iS�S�T� �.•S� �,� � , � Square Feet: ��"�s Rate Computed At: � '� � ���-��►�s �,� �t i j Valuation: �-��i"`a (Use System Calc for Fees) � Radon: � I� ����: �'���i' °-j iR;��, Connection Fees: _ r?'�`'�'�• �b���� •�i.,.��� i ���� Sewer: .� n i► � V. fl 1�,2fo�� � '7���r� 5� I� r i�-�4� �.. � Water: j���� �`���� ���9.j� Water Meter: Size 10/01/10(update 6/1/14) � �, 3/4" 457.18 All Residential � 1" 835.09 � � �� P�c. 1.5" 1 ,369.14 ���1'i 6� ���i�� 2" 1,687.35 3" & 4" $Get w/Utilities Superintendent Irrigation Connection: 266.00 Plus Meter Charge Above Based on size , Impact Fees: School: ti�l � Transportation: � ��'�r 5'��1�'�� Park: � I�S Public Safety: N-/� —�R�� +��' 5•�-�� � °( � -�-� � �- -� � � ��`� � �� ��-�- �-��'-��-- W�17=�� �- t���� n�,-� �_ � Z.��'!��(RHlLL�� �I�� ��P����fi�P�f 6907 Dairy Road, Zephyrhills, FL 33542 FIf2E �ER�E�� U�E� FEES Occupancy No.: , �. Pla� fVo.: Contractor: ��,�1�'�N �=-'(.ti;'"-�"� Business Name: Billing Address: Business Address: (���- �+t��J (L�; Business Phone No.: ��� "��� � 1�Z=Z- Billing Phone No.: Business Fax No.: Billing Fax No.: Contact: ��1}E. ;��;�-��.rL�,ti rs��.f Contact: PLAfd REVIEIW FEES INSPECTIOk FEES PERRAIT FEE FALSE ALIlRhA FEE Site Plan.•-�'"J��� y N/C - Annual N1C Sprinkler $50 1st�Alarm N/C ` Mulii-Family/Commercial .06 sf =�1st Re-inspection N/C Standpipes $50 2nd Alarm N/C ='� (Minimum Charge$25:00 �� 2nd Re-inspection $100 Fire Pump $50 3rd Alarm N/C � Plan Revisions DBL 3rd Re-inspection $250 Hoods $50 4th Alarm $100 4th Re-InspecGon $500 Fire Alarm $50 5th Alarm $150 SPRIkKLER SYSTE�RS (Business closed until LP Gas $50 6th Alarm $200 0-25 Heads $50 violations corrected) Natural Gas $50 NON COMPLIANCE $150 26 plus Heads $100 SPRINKLER SYSTERAS Fuel Tanks- pertank $50 STPJVDPIPE SYSTE�V Hydro Undergrounds $45 Sparklers $100 � Per Riser $50 Hydrostatic Test $65 per system Fire Works $500 FIRE PUMP Acceptance Test $45 persystem Camp Fire $25 � Per Pump $100 Hydrant Flow $75 Controlled Bum $100 FIRE AUlRRA SYSTEhA Hood/Duct $50 0-25 Devices $50 FIRE ALA,RM SYSTEAA Place of Assembly $50 Mnual 26 plus Devices $100 B System Acceptance $50 Fire Protection $25 SUPPRESSIOfY SYSTEARS Recall Acceptance $50 Flammable Application $50 Annual Wet $50 OTF9ER Waste Tire Storage $50 Mnual Dry $50 Flre walUSmoke Wall $15 per wall Generator<KW $100 CO2 $50 LP Gas $25 per tank Generator>30 KW 150 Other $50 Natural Gas $25 per system Bio-Hazard Waste $100 a,nuai iCIYCHEf�EXH/lUST Fumigation Tenting $50 � Hood/Ducts $50 Tent 10'x10'or greater $15 per tent Torch Pot/Applied $50 OTkER Fire Pump $45 Haz.Materials $100 Annual LP InstallaHon per tank $50 Fire Suppression $30 Fuel Tank Installation $50 System Acceptance ❑ (Per Tank) $50 � Exhaust Hood/Duct $30 Natural Gas Installation $50 Re-inspection DBL (Per System) (other than annual) �Spray Booth $50 ❑ Inspection scheduled DBL � and cancelled less than 24 hours Construction Insp. N/C Emergency Vehicle Ai $50 FALSE ALARAA �P S TOTAL� IMSPECTIOt�TOTAL� � PERfl91T TOTAL� TOTAL� ��� ,�� 1�� � ' �� GRAtdD TOTAL Comments: p7�TC� I��'�i'1 la-t,� i � ��-�,ns� c�,�'� 3'�t'��:. '�'f�5�\�-i� C�� �1 r�'��:�(i��`^. �— ��\�� :O.�S� 1!��1 C7d\� ��4- 'r��l ( �E3 e t.. _ I Jf�� 1���i a�� � Date: �v � ??��•"F Inspector: ! i' ��� nin i iiiiii iiiii uiii iiii�iiiii iiiii iiiii iiiii iiiii iiiii iiii iai 20140B5923 Ropl:1606242 Reo: 10.00 . , ._ DS: 0.00 IT: 0.00 . 0B/29/!4 T. Sline, Dply Cle�k Pertnit No. Parcei ID No NOTICE OF COMMENCEMENT State of ��' County uf�p1r� �� THE UNDERSIGNED hereby gives nolice that impravement tirill be made to certain real property,and in accordance with Chapter 713,Florida Stalutes, the fotlowing in/artnation is pravided fn this Notice of Commencement: 1 Descriptian of PropeAy: Parcel Identification No. 0� 'Z� •�� 'Q'�� ��DO�����/) Slreet Address: �5�� �` �i N r �� — LC p h C.921�l��s ��' 2. Generel Description of Impravement �AI �f1'f7 �(�...(.,lC]L��CA"t' 3. Owner Infortnatlon or Lessee fnformatlon if the Lessee contracted(or the improvement: Suacz�ge 1��zo�-ez-E-�es o� ZcaF►4�zh�l�s .i�J • bSZO �ame ��n�� t�cQ,_ �a 7eQhU�h�ll� � Address Ciry �—' Slate Interest in Property: �1.17 Att �z U � � Name ot Fee Simple Tilleholder. , W Li.. � w (If diHerent from Owner lisled above) '�(,� � � -1 J U Address �'y r ' City State '�'z U O ~ 4 Q F— Cantredor. ��LV1ti6x� �,OtJSr�2ltiF�td� dsr'�L^ SA�C �Ur � 2 Q N � a 3641_Z"ams2. S4� 1�.9�S�E �hW r t h�(�C_ � L-� W z uWi a Address ��� —��� O�2S City � Stat :�� � Q ¢ � Contractors Telephane No.• . �� O O D U 5. Surety: � Name �� a W Y Address Cily Stale (�Q O � 0 � 2 U U z W Amount af Bond: 3 Telephone No.: Q�. � J Q J 6. Lender. �� w � � � U Name �� � � _ �_1 Address Ciry Stale �� Q z � � _ Lenders Telephone No. �Q Q� � 7 Persons wilhin lhe Stale of Florida designated by lhe owner upon whom notices or olher documents may be served as pravided 6y �F— Z � ' (n Seclion 713.13(1)(a)(7),Florida Statutes: �q(n Q J Q 1—� W � z _1 Name ;�� �z }= � u�t- r0 � a m Address Ciry State Telephane Number of Designated Person: 8. In addition to himself,the owner designales of_ � � � to receive�a copy of lhe Lienafs Notice as proNded in Secllan 713.13(7)(b),Florida Slatules. _`� .o � Telephone Number of Person or Entity Designaled by Owner. Gv o Ca��' m, 9. Expiratian dale of Notice of Commencement(lhe e�iration date may nol be befare the completion of construdion and final payment to the {i� contraCOr,but will be one year Gom the date of recording unless a diHerent date Is specified): � , WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AF7ER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT �•o ' L` '� �� ^ •C� ARE CONSIOERED IMPROPER PAYMEN7S UNDER CHAPTER 713, PART 1, SECTION 773.13, FLORIDA STATUTES, AND CAN � � � � RESULT IN YOUR PAYING TMCE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE ' � . � RECORDED ANO POSTEO ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT � v " ° WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. e� � Y . �.�q Under penalty of perjury,I dedare lhat I have read the foregoing notica of commencement and thal the fads slaled lherein ere true lo lhe besl �_ ',J�'3 of my knowledge and heliet. �� " ca STATE OF FLORIDA � u'� t '�� A }� COUNTY OF PASCO � •� Signature of Owner or Lessee,or Owners or Lessee's Authorized OKcerfDirectorlPartner/Manage r �Signatory's TitlelOmce I �_l__ �_. � Si—Llf�u � ♦ h�Q 1/l�_ � 7he(aregoing instrument was ecknowledged before me lhis day of 20 by ! as (type of authority,e.g.,oKcer�,Wstee,attomey in(act)for (name t pa o behat of whom fnstrument was exewted). Personatly Known[]�Praduced Identificalion❑ Notary Signature {�► Type af Identific ti Praduced Name(Prinq \\CrJ (� ;�eh�� HOLLY HOPPER - - : MYCOMMISSIONt�EE070468 PQULR S 0'NEIL,Ph.D.PR5C0 CLERK 6 COMPTROLLER � �� 08/29/14 04:1 1 of 1 � ,,' EXPIRES May 18,2015 OR BK 90�� P� 2929 , �07)�s8.pt53 FlorldaNOm arvlos,00m wpdata/bcs/noticecammencemenl�c053048 i June 19, 2012 Henri Pohjolainen 6250 Fort King Road Zephyrhills Florida, 33542 ' RE: Expansion and Improvements (Sunrise Properties) i ' Dear Henri, � This letter is a follow up of our meeting June 19th 2012 . In attendance were you, me, Todd Vandeberg, Kalvin Switzer and Bill Back. Items discussed and agreed upon are as follows . On August 9th 2005 you requested and were granted a variance to make improvements to your existing eastern non-conforming building. Phase one will be an addition to the eastern building (approximately 21 feet to the west) and other incidental exterior improvements . Phase 2 will be the build-out of three bays for Sunrise Properties accessory use. Phase 3 will be the start of the build-out of individual retail/office spaces for lease. It is at the time of permit of phase 3 that .it was agreed upon that the demolition of the west non- • conforming building will commence. � Credits for required impact fees (see attached) , will be applicable on a square feet basis as discussed and shown in previous correspondence. The city will receive at time of final inspection , of phase 1; an as-built site plan showing the addition, the future demolition of the west non- conforming building and an overlay of proposed parking for the complete project. Sincerely, . Bill Burgess Building Official � City of Zephyrhills , CC: Todd Vandeberg - ---- i 4` ` Fl�rida �nergy �ffeci��cy �od� For �uild��g �ons�ructior� EnergyGaug� SummitC� Fla/Com-2010, Effective Glate: March 15, 2012 -- Form 506-2010 Prescriptive Compliance foe Renovations, Occupa��cy Change, efic. PROJ�CT �UMMA�V �hart�esc: C0514153 �3eseY-�p�iou: Sunrise Manufacturing Inc Owa�er: Stmrise Manufacturing Inc Addres��: Fart I�ing&Eiland Blvd �fty: Zephyrhills Address2: S�a�e: FL �g�: 0 '�'�Tpe: Office Cl�ss: Renovation to existing buildi �oza�asdictia�t: ZEPI�3Y'RIIILLS,PASCO COITNTY,FL(611640} �or�di�oned Aa�e�: 9275 SF �oadataa�ed<nCond'a�oned flrea: 9275 SF I�To af��ories: 1 Area entered froffi PI�ns 9275 5F �'erm�t No: 0 Max Tonnage 4.1 If d°afferen�,wr��e�a�, (5)-a Ton Units EnergyGauge Summit0 FlalCom-2010.Section 5�6.4 Gompliant Software.Effective Date:March 15,2b12 5/29/2014 Page 1 of 7 ��ar�pli�aa�� Suxnrn��� C�rm�a��.e�at Ae�ig� �ri��°i� Res�l� RENOVATED ENVELOPE PRESCRIl'TNE 1'A�SE� LIGHTIl�TG POVJER 9,600.0 10,202.5 I'.�,.SSE� LIGIITIN�CC}NTR�I,S I�A���S E�iTERNAL LIGHTING N�ne E�atereti HVAC �YSTEM Pr�.�S�+� PLANT 1�Ione��a�ered WATER HEATIlVG SYSTEMS P�SSES PIPING SYSTEMS �1a����a�e�°�� Met all required coinpliance fioan Cl�eck Lis4? ��s/I��/Nr� IMPORTARIT MESSAGE info 54Q9 __ __ _m Ar� input report of this dasign building must be submitted aiong witi� this Compliance R�port � � EnergyGauge Summit0 FlatCom-2Q14.Sec#ion 506.4 Compliant Software.Effecfive Dafe:March 15,2012 5/19/2014 Page 2 of 7 � CEIZTI�"ICATIOlmTS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code �,f �J-�.c���E ` r Prepared By: Building Official: CONlYV1ERCIRL ENERGY RATER#749 Date: 05-19-14 Date: K� � '�"�� f certify that this building is in compliance with the FLorida Energy Efficiency Code Owner Agent: Date: If Required by Florida law, I hereby certify(�)that the system design is in compliance with the Florida Energy Efficiency Code Architect: Reg No: Electrical Designer: Reg No: Lighting Designer: Reg No: Mechanical Designer: P.eg No: Plumbing Designer: Reg No: (x) Signature is required where Florida La�n�requires design to be performed by regisiered design professionals. �'rojec�e �051415� 'I'itie:3u�ra§e DBanufact�rang Inc Type: �f�ice (�i'EA I'ile:FL_'I'E�1VI�'A_�t�EIa.NATIONAL, A�".t�3} Pres�rip�ive �nvel��e Co�pliance Itean Zo�e IDescripEion I)esign Criteraa Il�leet 12eq. Glass Unit 8-6 Percent glass Max allowed .004 50.000 Yes Slcylights Unit 8-6 Percent Slcylight Max allowed .060 5.000 Yes Glass Unit 5 Percent glass Max allowed .000 50.000 Yes Skylights Unit 5 Percent Sicylight Max allowed .000 5.000 Yes Glass Unit Percent glass tifax allowed .000 50.000 Yes Slcylights Unit Percent Slcylight Max allowed .Q00 S.OQO Yes I�eets Shell Envelope 12eq�irexnents--PASSES EnergyGauge Summit0 Fla/Com-2010.Section 506.4 Compliant Software. Effective Date:March 15,2012 Si19/2014 Page 3 of 7 E����°�nal :��g��i�� �o�tpli�n�� Descrip�aon Categoay TYadable? A19o�vance Ae-ea or Length�L�'A C]G�' {�1TJn�t} ar I�Ia.af TJnit� EtiV} (� (Sqft or ft) � 1�IOrae � Pro�ee�,C0514�58 Titie:Sun��nse 1VIaa�ufac�atring Inc `�Ae:{}ff�ee (WE�-1�'ile: FI, 'I'AMP�_YNT�I2NA'I'IO1�I�., A�'atrci3) Lightia�� I���vv�� ��rrl�li���� Space �-lshrae Descrapkaon Axea �ieighf IVa.mf �esagn Effective Allovvance ID (sq.f�} {f�) S��ce� (t�} (� (VV} O£�Cice 16 affice-Open Plan 5,677 16A 1 5848 5764 6,245 ' Office 16 Office-Open Plan 1,790 16.0 1 1936 1920 1,969 Qfftce 16 Office-Open Plan 1,308 16.0 l 1936 1920 1,9�9 �es��� a 96�4 (�i�} �I'�4S��S Ef.fec�ve: 960� �} Al�o�an��: 142Q�.���} Pa�sin��°�qaai�°�s I)esign�o be at�►os�100% of�ri�era� Pa-o,ject: �O�fl41�8 i 'I'itle: Sune�ise iVTanufac�urimg�nc 'I'ype: �ffiee (WEA I'�9e;�'L_'I'A.1VI�A IlVT��4NAT�PJI�AL �'.�att3) �igh�n� ��an�a c��s �t��aapl��.n�e �4.c�iaa�ym �is��•�e �:Descrgp�non rlx�ea I9esag� lYI� Ca�sp�- I�A (�q.f�} ��' CP' ance {)i�'zce 16 Qi�'"-tce-{?pea Pian 5,67'7 3 3 PA�SE� Oi�"ice 16 Of�"ice-Qpen Plan 1,790 1 1 �'ASSES 4fftce ]6 �f�ice-Open Plan 1,8�8 1 1 P�SSES ��PA�S�S � EnergyGauge SummitC�FlalCom-201� Sectian 506.4 Gompliasst Sofiware.Ef�ective Dafe:March 15,2012 Sf19/2014 Page 4 0£7 [ Proyect: C05141s8 �'a�le:�un�ise IVl�nufactiaza�an�Inc '1'ype:Offce (W�A File:�'L 'Y`��'c�Y1�TE12NATIONAL A.�atr�3} Syst�m ��p��t C�mplian�e ��Tl-� Syste�a ��5 C��s�a�t��l�arne��Cooled i'��.�f�J�a�� ��la't Sys�ern <65�00�t�(hr 5 Compaa�ent Category Capaefity 1Design Eff LBesign �'IsY Co�p- Eff Criterfia IPL'�' Criteria liance Cooling System Air Conditioners Air Cooled 13.00 12.23 8.00 PASS�S Split System<65p0€}BtuJh Cooling Capacrty Heating System Electric Furnace 1.Q0 1.00 �r�SSES Air Handling Air Handler(Supply)- 0.04 0.82 PA3S�� System-Supply Constant Uolume Air Handling Air IIandler(Return)- 0.00 4.82 t�A���S System-Retlun Consi�nt Volume �ASS�S � �1ant C€���li�n�� Descrip�eon 7f�sta�ed Size IDe�ngu I��i� Desig� IVIfln Category Ca�np l�To �ff �ff Il'LY IPI.v �ance �� NOr�e � P�oject: CQ514�53 T'itle;Sunri�e li�ar�a�fac�a�rpn�Ir�c '��pen �f�ce (W�A�'ile:�'L 'Tt`AIVII'� Il�'I'ERNAZ'��NA� AF.�3} 'V6�at���CI��.��� �ampli�.n�� �Bescri�t�io� '��pe �a�egofl°y �e�ign IVdi� Desag� Mfax Comp Eff �f£ Loss Lo�s ��nce Water Heater 1 Eleciric water heater <-12[IL`Nj 09� Q.97 PASSES �P�.S���" � EnergyGauge Summit0 FEaICam-2410.Section 5�6.4 Compliant Saftware. Effect�ve Dafe:March 15,2012 511912014 Page 5 of 7 � Piping System Coffipliance Categoey Pape Dia l� �perate�g Ins Comd Ims Req Ins Co�aplaance [�ches] ltunout? Te�p [�tu-in/9ir T�ick[i�J 'I'bick[�n] [F'l .SF.F'] �„ �ane � EnergyGauge Summit0 FlalCom-2010.Section 506.4 Compliant Software. Eifective Date:March 15,2012 ' Si 19/2014 Page 6 ai 7 PYOject: C051415� Title:Se��r�se Ma�ufactu�-a�g Inc 'I'ype: Office (iW�E1 F'ile;I`I,_TANda'A �I+dTE�NATIONAi� �'.t�n3) Otln�r �equired Cor��lianc� Category Secfion Itequfreffient(v��rite N/Aan box if not appifcable) Checl� Report 506.4.2 Input Report Print-Out from EnergyGauge F1aCom attached � Operations Manual 303.3.1, Operations manual provided to owner � 503.2.9.3, 'S65.7.4.2 Windows&Doors 502.3.2 Glazed swinging entrance&revolving doors:max. 1.0 cfm/ftz;all � other products:0.3 cfin/ft2 Joints/Cracks 502.33 To be caullced,gaslceted,weather-sfripped or otherwise sealed � Dropped Ceiling Cavity 502.3 Vented:seal&insulated ceiling.Unvented seal&insulate roof& � side walls HVAC Efticiency 563.23 Minimum efficiencies:Tables 503.2.3(1)-($) � HVAC Controls 503.2.4 Zone controls prevent reheat(exceptions};separate thermostafic � control per zone; Uentilation 5Q3.2.5 Outdoor air supply&e�chaust ducts shall have dampers that � automatically shut when systems or spaces served are not in us�. E7chaust air energy recovery required for cooling systems (Exceptions). �1DS 503.2.7.5 Duct sizing and Desib have been performed � HVAC Ducts SQ3.2.7 Air ducts,fittings,mechanical equipment&plenum chambers shall � be mechanically attached,seale�l,insulated&installed per TaUle 503.2.7.2.Fan pawer lin-utations. Balancing 503.2.9.1 HVAC dishibution system(s)tested&Ualanced.Report in � construction documents. Piping Insulation 503.2.8 HAC and seivice hot water.In accordance witti Table 503.2.8. � Water Heafers SQ4 Performance requirements in accordance u�th Table 504.2.Heat � trap requued. Swimnung Pools 504.7 Uapor-retardant or liquid cover or other means proven to reduce � heat loss on heated pools;Time switch(exceptions);readily accessible on./off switch. Motors 505.7.5 Motor efficiency criteria have been met � Lighting Cont�ols 505.2,502.3 4utomatic control required for interior lighting in buildings>5,000 � s.f.; Space control;Exterior photo sensor;Tandom wiring with 1 or 3 linear fluorescent lamps>30W EnergyGauge Summit0 Fla/Com-2010.Section 506.4 Compliant Sofiware. Effective Date:March 15,2012 5/19/2014 Page 7 of 7 V �ner Gaaa e Surnrr►at�v4o10 �I � � ���Z' �1,Z'������' Pr°o�ect Information Pa oject Naar�e: �0514158 Orienta�:non: West Pro,��cd'I'itle: Sunnse Manufacturing Inc Buil�ixi��ie: �¢�1Ce Address: Fort Y�in�&Eiland Blvd �uild'na�g Cbass��ic���:io�z: 1�enovation to existin�Uuilding State: � No.Of.S$i➢1 Y�S: j Zip: 0 GrossAaea: 9275 S�' Oe�va�ei c Sunrise 1VVianufacturing Inc �OII�S No Acroaaym Aescril��HOaa 'fl`yg�e Are� 19�Ienl�eplgex 'TmdalArea [5�7 [S�] 1 Unrt 8-6 Unit 8-6 CONDITIONED 5677 0 1 5677.0 ❑ 2 Umt 5 Unit 5 CONDITIONED 1790 0 1 1790 0 ❑ 3 Umt Unit CONDITTONED 1808.0 1 1808.0 ❑ 5l1�/2Q�b=& ��n�a•�YG�nn�e Sa�e�e�na�OO v4,1� 1 �pac�� 1�o t-lcrotayan I)escri�rntaa�n '�'g�g�e Del��h vVfcl�h EIeig1�C 1VV�aa�4r TotalAn•e� '�'ota➢�ce8ua�►e [ft] [��] [��] �ali�r [�� [cf� �aa Zan�: �.Tr�gt 8-C� I Office Office Office-Open Plan 119.26 �7,60 16 00 2 5677.0 90$32.1 � It�2o�aee Ilnit� 1 Office Office Office-Open Plan 37 61 47 66 16 OQ 1 1790 0 28640 0 � Ita�t��: TJnf� 1 Offioe Office Office-Open Plan 37 98 47,60 16.00 1 1808 0 2892$.0 ❑ Lp�gh��ng � li� '1'gge C�����ry T�t�.a�f Watts per I'o�vea• �on��•al'�`ype T�To,�f Luania►aiR•es 3,aan�ana�e [�] C�pE ys�s In Z�rae: �Iaeit g-� Zn Spacc: Office 1 LF�D General Lzgl�fing 60 96 5764 Occupancy sensor without 3 � Daylightzng 2 Conapzct�'luoresceut Exit Sign 6 8 4$ Security(continuous) 1 � Xtq 7JcAtae: Uanit S Yn S���c�: �?ffn�� 1 LED General Liglating 20 96 1920 t�ecupancy sensor�vithout 1 ❑ L7ayhglxtmg 2 Com�aet Fluorescent Exit Sib 2 8 16 Security{contm�.lous} i C] I�Zaqn�c TJu►i� � �xe Spe�ce: CA�'�a�:� 1 LF'D General Ligl�hng 20 96 1920 Occupa�zcy sexzsor witl�out 1 [] Dayhghtin� 2 Coxnpact Fluorescent Exit Si�� 2 8 16 Security(contna�ious) 1 [� 51�9120��8 �:���•g3'��a¢�;e S��r�iu�e�OO w=�.�4 2 lB4Ca I I� Nm I)�scrnp�h'on Type VV�cltl�H(�ffec) 1�1[ulti Area DirectfonCoaxductaaac� Heat I3eaes. la-Value [f�] [ft] plfer [sff [B4�a/ha•.sf. I+] Ca�a�cfty [lb/cffj [Ia.sf.F/�tu] [�tan/siF.l+]] �ta Zoaa�: UVI rtClovvs No Des�a•flg�tion �pe ShaQleQl U SFIGC Vas,Tr:� VV �I(Effee) MuYta TotmlAre� [Bhs/�u•sf F'] �f�� [}t] pliea� [S� Iaa�ne: Iaa�V:all: ❑ Doors l�m Desca•ip4eoaa 1'yg�� ShncleQl? �6'ic➢th �i(Effec) 11�Iulte Area Cond. D�ns, He�S Cap. 13-VaIlue [fl] [ft] pli�r [sfJ [Btu/hr. sf,F] [lb/cf� [�tu/sf.F] [h.sf.F/Btu] Ir��one: In W1ll: � �OO'�S No Descriptfon �gt� Width F�(�f�ea;) 1Vlulti ES�e� Tilt Conde Hea�Cap Dens. R-Yalue [ft] [ft] plier [sffj [deg] [Btu/lir. Sff. �] [Bt�a/�g T'] [ll�/�fj [h,s�FlB&u] Itn 2one: ❑ 5/Il°�/2�11�9 �+n�rgYG�awg�Sa�an�eaflg0 v4.fl� � 4 11 S�cy'Iv�ht� T°�o D�e�cn�aqrtu�ra T,y��e i.T S�IGC Vas.T'r�aas W �Y������ IVIAII�9�DIflC1• f4.a•�a 'Tot�fltSe•e� [�$�,i����rr� ���� ���1 (��6 [�fl � ��� ���n�: , �����e . � f�l�►�►�� j � �� l�T� TB�sex•fpti�aa 'I'g��ae WAC�tia �I��ffec} 1VIultf Aa��n Conci. I�eat C�p. I3es►s. R-�Rlue [��� Cft� �1��� t�� ��t��.��r� ������� C�ui�:ey �.S���t�l ����: � ��'S$�111� . „�.o. A�iU1-5 �ys�egn 1-5 Cons�aa�t Vcal�me t�aa��a�csl�d S�s�it I�to,�f�nAts 5 Syste��650Q0��:�lha• C€�m)sa��n�nt ��nt�gar�ry �apa�city Eftaeie�cy gl'A.� 1 Caolvag Systenl 490Q0.00 13.00 8.Q0 � 2 Heatulg System 34121.00 1.00 ❑ - 3 Air Handl'uig System-Supply 1633.00 0 00 � 4 Au-Handlmg System-Return 1633 00 0.00 ❑ �f��`1'� �c�unip�e�a�� ��f�g���y ���e Iaas�.l�Ta� �ff�: 1]PL� 5/19/249fl�9 �a�ea��YG�aaage Seaflnnaa�0 w�#.�0 4 � •� 6��9�6�� I��e��l�a�� �1V-I�eater I)�ss:�•ip�io�a Cn�acgd'Cap.LTnft I/P 12g. Effieien�y Loss 1 Electric water heater 1 [Gal] [1cW] 0 9700 [Ef] [Btu/h] � Ext—Lsghteng Deseriial�oea Cltegofl;y 1>To,of i�Vatts�en• l�a•e�/I�en/1°�o, of uxeet� Coratirol�pe Wattrag� ' Lumin�ires LaamunBire ��g/{t/�j�] �7] — � � ❑ I � �1�J1Y1� I 1�Tm Ty�e Operatinb Ia�sulll•ion 1�oenoIIial p�ipse Iresufation �s 13aanou�'? 'Tenapen•�etua�� Conc9uclivaty Di��n�ten� TkaicAai¢ss Lx'1 ���Q9—IR�fl.Sfl.� ��� ��� ❑ ��11CS�r��IOIQ �5�� N�aaae ��ass'.A�Iee 1�To, arf �i�nss S�IGC V�,� P�nes �onaluctanee [�du/�►.sf.I+'] ❑ 5/�9/B�➢�4 �fl��a•ayGBa�ge Suaaaeni����.fl� 5 �, J l�Zat�ria�� �7s�d � ��a�y Ii-Va�ue R�a�ve �'1ni�l�aess �,.'Q11Y(IQl��1Vfl�' $Pensify Spe�cificgleaB j 1,�l�n� 1�Tm Aeroaay� D��s�a•ig�ta�� YTsed [da.sff,I'l�du] [ft] [�3tu/dA<ft.F'] [Ib/et] [�tu/�b,I+� � � C�riStr°uc�s IT��ed Nm� l�at�e S�ey�le Massless Coneluc�t�ace II-Iea4�agracx�y �Densidg� Y�Ualue C�a�s�ru�t Con��iuct [Btna/�a.sf.]F"] [Bteal�f.F] [ilaleffJ [Ia.sf.FlBtu] ❑ I,�g�ea° 1�d�t�xnaaY IV�akea•a�u➢ �I'IflIl���d�SS I+'r�atu►agg l�Ia�a [�'t] �`ac��a� ❑ 5/19/�QDl� �neY•�J'Gaxag�Sueba�aaitOO v�6.10 6 f Job: C0514158 � V�/�,19��SOftW Equiprnent Surr�mary BYte: MMaN12,2014 � ��i/7 ` ' Randy 1�latson Designs Inc 13821 US Hwy 98,Dade City,FL 33523 Phone:352-523-2077 • • ' • • For: Sunrise Manufacturing Inc Fort King&Eiland Blvd, Zephyrhills, FL Base System: Cooling: Rheem or Eqv. Split AC 14AJM48 Coil Model: RHLL-HM4821++RCSL-H'`4821 , Total cooling capacity= 49000 Btuh, 12.5 EER, 14 SEER, Sound Level= 0 0 Heati ng: ` Input= 10 kW, Output= 34121 Btuh, 100 EFF Warranties: Featu res: Investment 1: Cooling: Coil Model: Total cooling capacity= 0 Btuh, 0 SEER, Sound Level = 0.0 Heati ng: Input= 0 Btuh, Output= 0 Btuh, 80 AFUE Water Heating: Gas conventional 40 gal tank, 36 MBtuh input, 0.60 EF Warranties: Featu res: -�1- wreghtsoft' - 2oia-May-�s�a:aa:zs I RightSuite�Universal 2013 13.0.11 RSU07440 Page 1 File\C0514158-Buildouts Typica�C0514158.rup Calc=MN5 Building Front faces: W 1 i , _ r 4 Job: C0514158 � ��,;9h����� Equiprnent Summary Date: IUlay 12,2014 �H�� By: TMN ` ' Randy Watson Designs Inc 13821 US Hwy 98,Dade City,FL 33523 Phone:352-523-2077 � � ' • i For: Sunrise Manufacturing Inc Fort King & Eiland Blvd, Zephyrhills, FL Base System: Cooling: Rheem or Eqv. Split AC 14AJM48 Coil Model: RHLL-HM4821++RCSL-H*4821 Total cooling capacity =49000 Btuh, 12.5 EER, 14 SEER, Sound Level= 0.0 Heati ng: Input= 10 kW, Output= 34121 Btuh, 100 EFF Warranties: Featu res: Investment 1: ' Cooling: Coil Model: Total cooling capacity= 0 Btuh, 0 SEER, Sound Level= 0.0 Heati ng: Input= 0 Btuh, Output= 0 Btuh, 80AFUE Water Heating: Gas conventional 40 gal tank, 36 MBtuh input, 0.60 EF Warranties: Featu res: -�- wrigh�soft'° Ri htSuite�Universal 2013 13.0.11 RSU07440 2014-May-19 74:34:26 9 Page 3 File1C0514158-8uildouts Typica�C0514158.rup Calc=MN5 Building Front faces: W � �Z Job: C0514158 �A/C19�'1�5��� Equipment Surr�mary Date: May 12,2014 /Q��;� By: TMN ` ' Randy Watson Designs Inc 13821 US Hwy 98,Dade City,FL 33523 Phone:352-523-2077 � • ' i • For: Sunrise Manufacturing Inc • Fort King& Eiland Blvd, Zephyrhills, FL Base System: Cooling: Rheem or Eqv. SpIitAC 14AJM48 Coil Model: RHLL-HM4821++RCSL-H*4821 Total cooling capacity= 49000 Btuh, 12.5 EER, 14 SEER, Sound Level= 0.0 Heating: Input= 10 kW, Output= 34121 Btuh, 100 EFF Warranties: Featu res: i Investment 1: Cooling: Coil Model: Total cooling capacity = 0 Btuh, 0 SEER, Sound Level= 0 0 Heati ng: Input= 0 Btuh, Output= 0 Btuh, 80AFUE Water Heating: Gas conventional 40 gal tank, 36 MBtuh input, 0.60 EF Warranties: Featu res: -�- ervrightsoft' 2014-May-1914:34:26 RightSuite�Universal 2013 13.0.11 RSU07440 Page 5 File\C0514158-Buildouts Typica11C0514158.rup Calc=MN5 Building Front faces: W E�f u�t1 ment Summa Job: C0514158 � V19r19�'1�SOfta q r � Date: May 12,2014 AHU4 ey: rnnr� ' ' Randy Watson Designs Inc 13821 US Hwy 98,Dade City,FL 33523 Phone:352-523-2077 ° • ' • • For: Sunrise Manufacturing Inc Fort King& Eiland Blvd, Zephyrhills, FL Base System: Cooling: Rheem or Eqv SpIitAC 14AJM48 Coil Model: RHLL-HM4821++RCSL-H*4821 Total cooling capacity =49000 Btuh, 12.5 EER, 14 SEER, Sound Level = 0.0 Heati ng: Input= 10 kW, Output= 34121 Btuh, 100 EFF Warranties: Featu res: Investment 1: Cooling: Coil Model: Total cooling capacity= 0 Btuh, 0 SEER, Sound Level= 0.0 Heati ng: Input= 0 Btuh, Output= 0 Btuh, 80AFUE Water Heating: Gas conventional 40 gal tank, 36 MBtuh input, 0.60 EF Warranties: Featu res: -�'�- wrightsoft° RightSuite�Universal 2073 13.0.11 RSU07440 2014-May-19 14:34:26 Page 7 File1C0514158-Buildouts Typica11C0514158.rup Calc=MN5 Building Front faces: W \ E�y 1,10�y ment Surr�ma�/ Job: C0514158 � W�'19ht�oft� �7 I� •l Date: May 12,2014 AHUJ'� By: TMN ' � Randy Watson Designs Inc 13821 US Hwy 98,Dade City,FL 33523 Phone:352-523-2077 ' s - • e For: Sunrise Manufacturing Inc Fort King& Eiland Bivd, Zephyrhills, FL Base System: Cooling: Rheem or Eqv Split AC 14AJM48 Coil Model: RHLL-HM4821++RCSL-H*4821 Total cooling capacity= 49000 Btuh, 12.5 EER, 14 SEER, Sound Level= 0.0 Heati ng: Input= 10 kW, Output= 34121 Btuh, 100 EFF Warranties: Featu res: Investment 1: Cooling: Coil Model: Total cooling capacity = 0 Btuh, 0 SEER, Sound Level = 0 0 Heati ng: Input= 0 Btuh, Output= 0 Btuh, 80AFUE Water Heating: Gas conventional 40 gal tank, 36 MBtuh input, 0.60 EF Warranties: Featu res: '�"}' WI'Igf'9tSOft" Ri htSuite�Universal 2013 13.0.11 RSU07440 2014-May-19 14:34:26 9 Page 9 File1C0514158-Buildouts Typical1C0514158.rup Calc=MN5 Building Front faces: W ° RigMt-Suite� Universai 2073 Load Summary Jab: C0514458 WI'1��'�SClft� �HU� Date: May 12,2014 By: TMN ' ' Ftandy Watson Clesigns Ina 13821!JS Hwy 98,Dade City,FE 33523 Phone:352-523-2077 ° 0 ° � 9 Far: Sunrise Manufacturing Inc Fort King&Eiland Blvd, Zephyrhills, F� . _ :. , _�. ; .. _ _ . __ ,Zone::. -AHU_1,. -':v_: � _�:,,,... _-;.._; >� _;; � , <..:.COOL.IN.G:'L4AD :: � .,: ;° __:.... -.- �:.- �_ :-,.�..,�, : � -:..i_..;, --... l. I9ESIGN C�ND�IONS at Aug 170Q LDT Peak laad at Aug'3700�DT Inside: 7� °F Outside: 92 °F' TD: 17 °F RH: 56 % MoistDiff: 60.1 gr/Ib Mult: 1.0 Ins.wb 63 °F Sensible Latent 2. SOLAR RADIATION THRCIUGH GLA5S 167$6 - 3. TRAN5NIISSIONGAINS Sensible 7666 - - Wa11s: 2878 - - Glass: 1648 - - Doars: 214 - _ Partitions. 0 .. _ Flaors 0 - - Ceilings: 2g26 _ _ _ 4. INTERIYALHEAT GAIN Sensible 1_atent 68Q2 2200 Occupants: 2613 2200 - - Lights: 4190 - - - Motars: 0 _ _ _ Appliances: 0 0 - - 5. INFII,TRATIdN: Outside air cfm: 0 Q 0 G. SUBTOTAL: Space laad Sensible �atent 31254 2200 Envelope 31254 2200 - - Less external 0 - _ _ � Redistribukion 0 tl _ _ 7. SUPPLYDiTC'I" 2t}pg _ 8. SUBTOTAL: Space load+supply duct 33662 - Actual cfm: 1633 at supply TD: 2Q - - 9. VENTII,ATION: Make-up air cfm: 156 2838 6366 l0. �2ETURNAdR,�.oA�: Lighting+plenum{net) 0 - 11. RETURNIDUCT 375 - 12. TOTAY..LOADS ON EQUIl'MENT 36876 1 Q059 .:�_. . � - -=-; :.-� . -_ _, _ < . . _. . _ � .;. - .� �:- _ �: �� �_.HEAT[NG �E3A� � -',�-�.:=:"�:`w-.� �- -s. 13. DESIGNCONDITIONS Mult: 1.Q lnside: 70 °F Outside: 43 °F TD' 28 °F 14. 'TRANSNIISSI4�N LOSSES 23212 Walls: 3733 _ Glass: 2920 - Doors: �g3 _ Partitions 0 _ F)aors: 3273 - Cellings: 13092 - 15. IIYFII,TRAT�CDN: Outside air c#m: Q 0 16. SUBTOTAI.: Space load 232�2 Envelope 23212 - Less external 0 _ Less transfer 0 - Redistribution 0 . - 17. SUPPLYDUCT: 3�g 18. VENTILATION: Make-up air cfm: 156 4709 19. :EIUMI�)IFICATION 1884 Piping p Z�. fl2�TURND�7�T 372 21. TOTA�.HEATING LOAD UN EQUIPMENT 33745 yjyp-j n�c,���� 2014May-1914:3d:26 � RightSaita�Universal 2013 13.Q.11 RSU07440 page 1 File\C0514158-Buildouts Typica11C0514158.rup Calc=MN5 Building Front faces: W c Job: C0514158 �es.W Right-Suite� llniversal 2013 Load Summary � Wr19htSO�` - Date: May 12,2014 AHUZ By: TMN ' ` Randy �1latson Designs Inc 13821 US Hwy 98,Dade City,FL 33523 Phone:352-523-2D77 � • ' ! 0 For: Sunrise Manufacturing Inc Fort King& Eiland Blvd, Zephyrhills, FL ,._ . �._ _ .. _ .. ... _ _- -- �:- �., :, . , ,.., _, Zone:;� ANU2= ....,,�.- �_: . .� _ � ` �� �.: � COOLING LOAD :- � _ .: . , - � _ _ -._ . 1. DESIGN CONDTTIONS at Aug 1700 LDT Peak load at Aug 1700 LDT Inside: 75 °F Outside: 92 °F TD: 17 °F RH: 56 % MoistDiff: 60.1 gr/Ib Mult: 1.0 Ins.wb 63 °F Sensible Latent 2. SOLAR RADIATION THROUGI�GLASS 16786 - 3. TRANSMLSSIONGAINS Sensible 6867 - Walls: 1892 - - Glass: 1648 - - Doors. 214 - - Partitions. 0 - - Floors: 0 - - Ceilings: 3114 - - 4. YN'TERNALHEAT GAIN Sensible Latent 7309 2400 Occupants: 2850 2400 - - Lights. 4459 - - - Motors. 0 - - - Appliances: 0 0 - - 5. INFILTRATION: Outside air cfm: 0 0 0 6. SUBTOTAL: Space load Sensible Latent 30962 2400 Envelope 30962 2400 - - Less external 0 - - - Redistribution 0 0 - - 7. SUPPLYDUCT 2436 - 8. SUBTOTAL: Space load+supply duct 33398 - Actual cfm: 1633 at supply TD: 20 - - 9. VENTILATION: Make-up air cfm: 170 3097 6945 10. RETURNAIRLOAD: Lighting+ plenum(net) 0 - 11. RETURNDUCT 387 - 12. TOTAL LOADS ON EQUIPMENT 36882 10805 .. _. _:.. __ : . ._., _ ._<..: .:: :. :. .... ..:�-. � -. .. _ _, ._.. __ ._.. . _ , - . . . ..:: _ _. _. -. - . , : - � . -.-= �_.`>>�: : _:. HEATING,LOAD:=';;: �: _.,_=;:_:<=.-::;..=,..,' , .,: -.``.^_,." __Y.__:.<.=:__._'.., _, .:. 13. 1)ESIGN COIVI3I'd'IONS Mult: 1.0 Inside: 70 °F Outside: 43 °F TD� 28 °F 14. TRANSMISSION LOSSES 20490 Wal Is: 1787 - i Glass� 2920 - Doors. 193 - Partitions. 0 - Floors 1849 - Ceilings: 13739 - ' 15. INFILTRATION: Outside air cfm: 0 0 16. SUBTOTAL: Space load 204�0 Envelope 20490 - Less external 0 - L�ss transfer 0 - Redistribution 0 - 17. SUPPLYDUCT: 3465 18. VENTIL,ATION: Make-up air cfm: 170 5138 19. HUIVIIDIFICATION 2056 Piping 0 20. RETURNDIICT 382 , 21. TOTALHEATING LOAD ON EQUIPMENT 31532 �"�'�' V1P6'Igol'�SO�" Right-Suite�Universal 2013 13.0.11 RSU0744D 2014-May-19 74:34:26 Page 2 File1C0514158-Buildouts Typical\C0514158.rup Calc=MN5 Building Front faces: W . Job: C0514158 +� wrightsoft� Right-SuiteO Universal 2013 Load Summary AHU3 Byte. TMN12,2014 � ' Randy Watson Designs Inc 13821 US Hwy 98,Dade City,FL 33523 Phone:352-523-2077 � 6 ' 6 • For: Sunrise Manufacturing Inc Fort King& Eiland Blvd, Zephyrhilis, FL ,. � _._ _ _ _ . __ _._ __. _ ... - _ _. ;=Zone: � ` AHU.3:': _._ =_: __,. •;:: ...;;=; :, -;_ _„..:. �- C.00LING:L0'AD �= :: .;. :�.=,:_= ,-'...._.,:=- '.��_�� `.^' .;_ _;;;:=._:- _: . - .: 1. DESIGN CONDTTIONS at Aug 1700 LDT Peak load at Aug 1700 LDT Inside: 75 °F Outside: 92 °F TD: 17 °F RH� 56 % MoistDiff� 60.1 gNlb Mult: 1.0 Ins.wb 63 °F Sensible Latent 2. SOLAR RADIATION THROUGH GLASS 16786 - 3. TRANSMISSIONGAINS Sensible 6971 - Walls: 1961 - - Glass: 1648 - - Doors. 214 - - Partitions: 0 - - Floors 0 - - Ceilings: 3148 - - 4. INTERNALHEAT GAIN Sensible Latent 7357 2400 Occupants� 2850 2400 - - Lights: 4507 - - - Motors 0 - - - Appliances 0 0 - - 5. INFILTRATION: Outside air cfm: 0 0 0 6. SUBTOTAL: Space load Sensible Latent 31115 2400 Envelope 31115 2400 - - Less external 0 - - - Redistribution 0 0 - - 7. SUPPLYDUCT 2444 - S. SUBTOTAL: Space load+supply duct 33559 - Actual cfm: 1633 at supply TD: 20 - - 9. VENTILATION: Make-up air cfm: 173 3150 7065 10. I2ETURNAIRLOAD: Lighting+ plenum(net) 0 - 11. RETUYtNDUCT 387 - 12. TOTALLOADS ON EQUIPMEN�' 37096 10929 .:. � , ;. :�_.-. ._.�:. :-� _- ..__ ,:.._.... ... .:.. . .�,, � . _ - -_ - ,_ '_ -: : _ .:... . .. :... . . .._:-. _ ,.� . ; .: ....... ___.,. -_;.::-_: _ _. . _-.�-,_, :;. -_:.,, ; ..-...=..�;_,:: _.-=„ .----HEATING,-LOAD-_:=�_,"-.��::-.:-_=�<.<.:;'-:=`:� _ ..=": ._:. ___:._ . 13. DESIGNCONY)ITIONS Mult: 10 Inside: 70 °F Outside: 43 °F TD� 28 °F 14. TRANSNIISSION LOSSES 20635 Walls: 1852 - Glass: 2920 - Doors� 193 - Partitions� 0 - Floors: 1904 - Ceilings: 13765 - 15. INFII,TRATION: Outside air cfm: 0 0 16. SUB'�OTAL: Space load 2�35 Envelope 20635 - Less external 0 - Less transfer 0 - Redistribution 0 - 17. SUPPLYDUCT: 3482 18. VENTII.ATION: Make-up air cfm: 173 5227 19. HUNII�IFYCATION 2092 Piping 0 20. RETURNDUCT 382 21. TOTALHEATINGY,OAD ONEQUIPMENT 31818 � 4Nr1 f1�50�` , 2014-May-1914:34:26 g RightSuite�Universal 2013 13.0.11 RSU07440 Page 3 File\C0514158-Buildouts Typical\C0514158.rup Calc=MN5 Building Front faces: W r t � Right-Suit�� Urtive�s�l 2013 Load �umt�t�ry Job: C0514158 -�- wrigh�soft AHU� Date: May 12,zo�a By: TMN � Randy Watson Designs Inc � 13821 US Nwy 88,Dade City,FL 33523 Pfione:352-523 2d77 I ° b ' a i For: Sunrise Manufacturing Inc Fort King&Eiland Blvd, Zephyrhills, F� �._,. . .. - :°°Zone:�.-_�.:�_AHU4 .-:.�.::-_ - ,�^:-_.�: :_,, _,_,,:>�Y:_=, _ . _ _ , -_ - : � .. - __ - -__- °_ �_- __- _ . _. - _ . ._. ,.� v.... . , _ .. _ .� .C.00�ING-L:OAD� - -. ._:.� � _;.-:-r ._ ;`. �.,:��:� .:�.::.:�, _- _.. 1. DES`�GN CONDITIONS at Aug 1700�DT Peak load at Aug'1740 LDT Inside: 75 °F Outside: 92 °F TD� 17 °F RH: 56 % MoistDiff� 60.1 gr/lb Mult: 1.0 Ins.wb 63 °F Sensible �atent 2. SOLAR I2AI)IA,TION THROUGH GLASS 167$6 - 3. TRANSMISSIi3NGAINS Sensible 6457 - Wa11s: 1698 - - Glass. 1648 - - Doars: 214 - - Partitions� 0 - - Floars: 0 - - Ceilings: ' 2897 _ _ 4. IN'I'ERNALHEAT GAIN Sensibie I..atent 7473 280(} Occupants: 3325 2800 - - Lights: 4148 - - - Motars� � - _ _ Appliances 0 0 - - 5. INFILTRATION: C7utside air cfm: 0 0 0 6. . S�7BTOTA�: Space load Sensible Latent 30716 2800 Envelope 30716 2800 - - Less external 0 - - - Redistributian 0 0 _ - 7. SUPPLYDUCT 2355 - 8. SUBTOTAL: Space load+supply duct 33073 - Actua! cfm: 1633 at suppiy TD: 20 - - 9. VENTIL.ATION: Make-up air cfm: 174 3175 7120 l0. RETU�tNAIR LOAID: Lighting+ plenum(net} 0 - Il. RETURNDUCT 375 - 12. TOTAL LOADS ON EQiJIPMENT 36621 11329 , -.- . � - - - • - _ �. � ;��:;�__y- _�_. _.... .. . ___ . � :-,,,.: :->;:.: ;,_ . :.::..:..:...:,�HE�TfNG;.LOAD�;::.,-_.:�:-.=-.:��-��.:°-: >�-;��_ „J=.:.;:-. �- -:�_, �. ,__,: .: ... 13. DESIGNCONDITIQNS Mult: 1.0 lnside: ?0 °F Outside: 43 °F TD: 28 °F 14. TRAN�MISSION LOSSES 19059 Waiis. 1597 - Glass. 2g2p _ D oors: 193 - Partitions. 0 - Floors 1704 - Ceilings: 12644 - 15. LNF`ILTRATION: tJutside air c#m: 4 0 16. SI7BTOTAL: Space ioad 19p59 Envelope 19059 - Less externai 0 _ Less transfer 0 .. Redistribution 0 17. SITPPLYI}UCT: 3337 18. VENTII.ATION: Make-up air cfm: 174 5268 19. L-Ii71V�IDIFICA'TION 2�pg Piping p Z0. RETURNDUCT 370 21. TOTALHEATINGLOADONEQUIPMENT 30142 yue-� ��.r���� 241d-May-t9 14:34:26 g RightSuite�Unive3sal 2013 13.0.11 RSU07440 Page 4 File\C0514158-Buildouts Typical1C0514158.rup Calc=MN5 Building Front faces: W Righ�-SuiteO Universal 2013 Load Summary Job: C0514158 '�`�' WI'!��'1#�O'�#" AHUS Byte: MaMy�12,2014 � � Randy UVatson Designs Inc 13821 US Hwy 98,Dade City,FL 33523 Phone:352-523-2077 ° i ° 0 9 For: Sunrise Manufacturing Inc Fort King& Eiland Blvd, Zephyrhills, FL <_Zone: ,AHU5 ': ;. :_ _-- " -,- -:._�_ �. _ - .CO:OLIN'G:L'O'AD=:_" : =;-_�- : �-_';-�='-.._:_..; ::=.,. .. . .-;�"",-_-.._:- ..,�::- 1. DESIGN CONDTTIONS at Aug 1700 LDT Peak load at Aug 1700 LDT Inside: 75 °F Outside: 92 °F TD: 17 °F RH. 56 % MoistDiff: 60.1 gr/Ib Mult: 1.0 Ins.wb 63 °F Sensible Latent 2. SOLAR RADIATION THROUGH GLAS5 16786 - 3. TRANSNIISSIONGAINS Sensible 652Q - Walls: 1731 - - Glass: 1648 - - Doors� 214 - - Partitions. 0 - - Floors: 0 - - Ceilings. 2926 4. IN'TERNALYI�AT GAIN Sensible Latent 7516 2800 Occupants. 3325 2800 - - Lights. 4191 - - - Motors� ' 0 - - - Appliances� 0 0 - - 5. INFIi�TRATIOIV: Outside air cfm: 13 230 516 6. SUBTOTAL: Space load Sensible Latent 31052 3316 Envelope 31052 3316 - - Less external 0 - - - Redistribution 0 0 - - 7. SUPPLYDUCT 2362 - 8. SUBaOTAL: Space load+supply duct 33414 - Actual cfm: 1633 at supply TD: 20 - - 9. VEIV�TILATION: Make-up air cfm: 175 3190 7154 10. RETiJRNAIdiLOAD: Lighting+ plenum(net) 0 - 11. Y�TUR1V DUCT 375 - 12. TOTALLOADS ON EQUIPMENT 36980 11882 - � _ , . .. ;� .__.:�.:--,:. _,::- - _ .�...._� :---� - - . .._ ,._ .. :_ _. :=::.:;_,_ -_- - _ - --_ - : .: :_�.�=..:_ :- . :-, , ; ' .�:� _ `-;":=°=_: ::-�_�HEATING LO__D=:��.<<` .: ::___ :__'-_:�.:•- =� - =_ 13. DESIGN CONDITIONS Mult: 1.0 Inside: 70 °F Outside: 43 °F TD: 28 °F 14. TRANSNILSSIONLOSSES 19262 Wal Is: 1627 - Glass: 2920 - Doors 193 - Partitions: 0 - Floors. 1732 - Ceilings. 12790 - 15. INFILTRATION: Outside air cfm: 0 0 16. SUBTOTAL: Space load 19262 Envelope 19262 - Less external 0 - Less transfer 0 - Redistribution 0 - 17. SUPPLYDUCT: 3350 18. VENTILATION: Make-up air cfm: 175 5293 19. HUlVdIDIFIC.�TION 2118 Piping 0 20. RETURNDUCT 370 21. TOTALI3EATINGLOADONEQUIPMENT 30394 "�' WCIg''1tS0'�'" RightSuRe�Universal 2013 13.0.11 RSU07440 2014-May-19 1 Pa4e 5 9 File1C0514158-Buildouts Typica11C0514158.rup Calc=MN5 Building Front faces: W � Right�uite0 Universal 2013 Load Sumrtnary Job: C0514158 '� W�'I���S�� Date: May 12,2014 CIOSet By: TMN ' Randy Watson Designs Inc 13821 US Hwy 98,Dade City,FL 33523 Phone:352-523-2077 ° • ' • i For: Sunrise Manufacturing Inc Fort King&Eiland Blvd, Zephyrhills, FL - �Zone:_-`� Closef::�;`� _=.:: _;�`-; -: �� °' - --_- = - __ - -_ - _ - _ __ - - .= _ � . - = __ -_-� _ _-_- , ,_ ` - _.. . ..,.. . .., ... . ,. . _ .. .� ,. ,. < :;.:, ._ , , -- �� = � :"COOLING:LOAD_��_:::�:_: ._::_ °. . �,:.:,-� `=" :_;_i:M1, , . 1. D�SIGN CONDTTIONS at Aug 1700 LDT Peak load at Aug 1200 LDT Inside: 75 °F Outside: 92 °F TD: 17 °F RH: 56 % MoistDiff� 60.1 gr/Ib Mult: 1.0 Ins.wb 63 °F � Sensible Latent 2. SOLAR RAIDIATION THROUGH GLASS 0 - 3. TRANSIVIISSYON GAINS Sensible 79 - Wal Is: 0 - - Glass. 0 - - Doors: 0 - - Partitions. 0 - - Floors. 0 - - Ceilings: 79 - - 4. YNTERI�TALHEAT GAIN Sensible Latent 113 0 Occupants: 0 0 - - Lights: 113 - - - Motors� 0 - - - Appliances� 0 0 - - 5. INFII,TRATION: Outside air cfm: 0 0 0 6. SUBTOTAL: Space load Sensible Latent 192 0 Envelope 192 0 - - Less external 0 - - - Redistribution 0 0 - - 7. SUPPLYDUCT 15 - S. SUBTOTAL: Space load+supply duct 207 - Actual cfm: 10 at supply TD: 20 - - 9. VENTILATION: Make-up air cfm: 0 0 0 10. RETURNAIRLOAD: Lighting+ plenum (net) 0 - 11. RETURNDUCT 2 - 12. TOTAL LOADS ON EQIIIPMENT 210 40 .- , .. ,. , . : - _ .,_ ._:. : . .. -..: . ..' .. - _ _=HEATIIVG`LOAD:=�-.�: -_=��-,:;�_;__-:�r=� �`; �-� -' - �--. _ -_- . _ 13. DESIGNCONY)ITIONS Mult: 1.0 Inside. 70 °F Outside: 43 °F TD: 28 °F 14. TRANSNIISSION LOSSES 549 Walls' 0 - Glass. 0 - Doors: 0 - Partitions. 0 - Floors. 0 - Ceilings. 549 - 15. INF`ILTRATION: Outside air cfm: 0 0 16. SUBTOTAL: Space load 549 Envelope 549 - Less external 0 - Less transfer 0 - Redistribution 0 - 17. SUPPLYDUCT: 84 18. VENTIY�ATION: Make-up air cfm: 0 0 19. HUNII�IFICATION 0 Piping 0 20. RETURN DUCT 9 21. TOTALHEATINGLOADONEQUIPMENT 642 l/li6'1 f'1'�SO'�" 2014-May-1914:34:26 - g RightSuite�Universal 2013 13.0.11 RSU07440 Page 6 File\C0514158-Buildouts Typica�C0514158.rup Calc=MN5 Building Front faces: W -� �nrri h�soft`� Right-Suite� Universal 2013 Load Summary Job: C0514158 - � R/�4 Byte: MMa N 12,2014 � ' Randy �llatson Designs Inc 13821 US Hwy 98,Dade City,FL 33523 Phone:352-523-2077 • i ' • 0 For: Sunrise Manufacturirlq Inc Fort King& Eiland Blvd, Zephyrhills, FL _:. -r .. . . .: -�.: , , .,. :, . _ . . -_ - _ _ ._. _. .= < °Zone; -;, ,RR4�. - :: :... . .. ....... _ _ ;_ : . _. :,,= ,._- .�:__;.:: ; ,, :___ coo�iN�::�oAD ::_ v==;-..,. �_.,_�, -. ,.,: _ 1. DESIGN COI�IIDYaIONS at Aug 1700 LDT Peak load at Aug 1500 LDT Inside: 75 °F Outside: 92 °F TD: 17 °F RH� 56 % MoistDiff: 60.1 gr/Ib Mult: 1.0 Ins.wb 63 °F Sensible Latent 2. SOLAR RADIATION THROUGH GLASS 0 - 3. TRANSMISSIONGAIN5 Sensible 306 - Walls: 213 - - Glass: 0 - - Doors: 0 - - Partitions: 0 - - Floors. 0 - - Ceilings. 93 - - 4. YNTERNALHEAT GAIN Sensible Latent 134 0 Occupants: 0 0 - - Lights: 134 - - - , Motors� 0 - - - Appliances: 0 0 - - 5. INF'II,TI�TION: Outside air cfm: 13 230 516 6. SiT�TOTAi.: Space load Sensible Latent 670 516 Envelope 670 516 - - Less external 0 - - - Redistribution 0 0 - - 7. SUPPL�'DUCT 51 - 8. SUBTOTAL: Space load+supply duct 721 - Actual cfm: 36 at supply TD: 20 - - 9. VENTILATION: Make-up air cfm: 0 0 0 10. RETiJYtNA1RLOAD: Lighting+ plenum(net) 0 - 11. RETURNDUCT 8 - 12. TOTALLOADSONEQUIPMENT 729 561 _ .._ . _.. .. _._.._- - : _. ,_ -_ -_ _ = . -- -=- -_ :->.HEATING-`LOAD-;.�::�:- � �:=;_._::�<;:�" :-<" - _. =--:_�-_ .._:' :_:=_::;:`:``� � `.- - .. . _ .:- > . _ , .:>,...,`. . ._ .. ,,. .. _ _ ; _ .� . . ... ..... . .....,� .,-r ,, , t.,. .__ ,_ :, :.._:_. �:,;. _ . - . -- ,- . ___.. . . 13. DESIGNCONDITIONS Mult: 10 Inside: 70 °F Outside: 43 °F TD: 28 °F 14. TRANSMLSSION LOSSES 1009 Walls� 190 - Glass: 0 - Doors: 0 - Partitions: 0 - Floors. 172 - Ceilings: 647 - 15. INFILTRATION: Outside air cfm: 0 0 16. SIJBTOTAL: Space load 1009 Envelope 1009 - Less external 0 - Less transfer 0 - Redistribution 0 - 17. SUPPLYDUCT: 175 18. VENTILAT�ON: Make-up air cfm: 0 0 19. HUNIIDIFICATION 0 Piping 0 20. RETURNI?UCT 19 21. TOTALHEATINGLOADONEQUIPMENi' 1204 � ���g�t���� RightSuite�Universal 2013 13.0.11 RSU07440 2014-May-19 1 Pa4:e 6 9 File\C0514158-Buildouts Typica�C0514158.rup Calc=MN5 Building Front faces: W � wrig11tS8'P�w ��ght�uite� Universal 20�3 Load Summar-y Job: C0514158 RR� Byte: MaMN12,2014 � ' Randy Watson Designs Inc 13821 US Hwy 98,Dade City,FL 33523 Phone:352-523-2077 o • ' � � ` For: Sunrise Manufacturing Inc Fort King& Eiland Blvd, Zephyrhills, FL Zone:-"�:;RRS�.-° _ ,. _.. : ,.COOLI�NG LOAD .- _ :';,,:-:: ..- �,_,_.-� .-:� _ , ,- . ; _ 1. DESIGN CONDTTIONS at Aug 1700 LDT Peak load at Aug 1400 LDT Inside: 75 °F Outside: 92 °F TD: 17 °F RH: 56 % MoistDiff: 60.1 gr/Ib Mult: 1.0 Ins.wb 63 °F • Sensible Latent 2. SOLAR RADIATION'�d3ROUGH GLASS 0 - 3. TRANSIVIISSIONGAINS Sensible 310 - Walls: � 224 - - Glass: 0 - - Doors. 0 - - Partitions. 0 - - Floors: 0 - - Ceilings: 86 - - 4. IlVTERNALflEAT GAIN Sensible Latent 124 0 Occupants 0 0 - - Lights. 124 - - - Motors. 0 - - - Appliances: 0 0 - - 5. INFILTRATION: Outside air cfm: 0 0 0 6. SUBTOTAY,: Space load Sensible Latent 434 0 Envelope 434 0 - - Less external 0 - - - Redistribution 0 0 - - 7. SUPPLYDUCT 33 - S. SUBTOTAL: Space load+supply duct 467 - Actual cfm: 25 at supply TD: 20 - - 9. VENTII.ATION: Make-up air cfm: 0 0 0 10. RETURNAIItLOAD: Lighting+ plenum(net) 0 - 11. RETURNDUCT 5 - 12. TOTAL LOADS ON EQUIPMENT 473 42 �� - - - - , ,,._.__ - . _: . � -- - - - _ . ,. : - . ' _,._,. � - - - � _ _.._HEATING tOAD- _. - ' _:--�:: :=;_:_� ` _ - „ �" 13. DESIGNCONDITIONS Mult: 1.0 Inside: 70 °F Outside: 43 °F TD: 28 °F 14. TRANSNIISSION LOSSES 979 , Walls. 199 - , Glass: 0 - Doors: 0 - Partitions: 0 � - Floors: 181 - Ceilings: 598 - 15. INFILTRATION: Outside air cfm: 0 0 16. SUBTOTAL: Space load � 979 Envelope 979 - Le.ss external 0 - Lesstransfer 0 - Redistribution 0 - 17. SUPPLYDUCT: 171 18. VENTIL,ATIOIV: Make-up air cfm: 0 0 19. I3U1d+�II'ICATION 0 Piping 0 20. RETURN DUCT 19 21. TOTAI,HEATING LOAD ON EQUIPMEN I' 1170 �0„� �.�5��� 2014-May-1914:34:26 - g RightSuite�Unlversal 2013 13.0.11 RSU07440 Page 8 File\C0514158-Buildouts Typica�C0514158.rup Calc=MN5 Building Front faces: W 1� Right-Suite� Universal 2013 Load Sumrrrary Job: C0514158 � M/�-19eltS0�" RRS Byte: MaMN12,2014 �t� � ' Ftandy UVatson Designs Inc 13821 US Hwy 98,Dade City,FL 33523 Phone:352-523-2077 � � ' • i For: Sunrise Manufacturing Inc Fort King& Eiland Blvd, Zephyrhills, FL _.. , , „ . � .,. � . __ _.._ : _ ._ .. .. . �._ .. _.. .. . _. � , �. .. .,..:. _ ._ - - - .Zqne: .. "=.RR6; , _ : • .�-._�,:_._ : : .:`:�COOL:ING°-LfJAD.�_.,_ . , _ ,-:.,,;.:,::_ `-:� �_:`-__ =_ ;=-: . _ -_ : - 1. DESYGN CO1vDTTIONS at Aug 1700 LDT Peak load at Aug 1400 LDT Inside: 75 °F Outside: 92 °F TD: 17 °F RH 56 % MoistDiff: 60.1 gr/Ib Mult: 1.0 Ins.wb 63 °F Sensible Latent 2. SOLAR RAD�ATION THROUGH GLASS 0 - 3. TRANSNIISSIONGA�TS Sensible 372 - Walls. 269 - - Glass: 0 - - Doors. 0 - - Partitions 0 - - Floors: 0 - - Ceilings: 104 4. INTERNALIiEAT GAIlY Sensible Latent 148 0 Occupants 0 0 - - Lights. 148 - - - Motors. ' 0 - - - Appliances 0 0 - - 5. INFILTRATYON: Outside air cfm: 0 0 0 6. SUBTOTAL: Space load Sensible Latent 521 0 Envelope 521 0 - - Less external 0 - - - Redistribution 0 0 - - � 7. SUPPLYDUCT 41 - S. SUBTOTAL: Space load+supply duct 562 - Actual cfm: 29 at supply TD: 20 - - 9. i�ENTILATION: Make-up air cfm: 0 0 0 10. RETURNAIRLOAID: Lighting+ plenum(net) 0 - 11. RETURNDUCT 6 - 12. TOTAL LOADS ON EQUIPMENT 568 48 ,-, _-- _-__ : -- _� - _. ____--_ _ _ - -- -D:==-:>=. _ _:: :__=-�-:.="_ = : _ - ,- - - . ., � ., ,. _ _ _ -.. �,� ;__ :,:.� . , _, � --::<.: -,_��.. :.. . _�,.:_. -_. =�H EATIIV;G'LOA_,. - -� _ ; . �� .. ,: . : :� . . : - _ . � �. , 13. DESIGNCONDITIONS Mult: 1.0 Inside: 70 °F Outside: 43 °F TD: 28 °F 14. TRt1N5MISSION LOSSES 1175 Wal Is. 239 - Glass. 0 - Doors 0 - Partitions 0 - Floors� 218 - Ceilings 718 - 15. INFILTRATION: Outside air cfm: 0 0 16. SUBTOTAL: Space load 1175 Envelope 1175 - Less external 0 - Less transfer 0 - Redistribution 0 - 17. SUPPLYDUCT: �9$ 18. VENTIL,ATION: Make-up air cfm: 0 0 19. HUNIIDIFICATION � Piping � 20. 12ETURN DUCT 22 21. TOTALHEATINGLO�ONEQUIPMENT 1395 -�- �vrigh�soft" 2014-May-1914:34:26 RightSuite�Universal 2013 13.0.11 RSU07440 Page 9 � File\C0514158-Buiidouts Typica�C0514158.rup Calc=MN5 Building Front faces: W Right-SuiteO Universal 2013 Load Summary Job: C0514158 �- wrightsoft� RR7 Byte: MMaN12,2014 � ' Randy 1lVatson Designs Inc 13821 US Hwy 98,Dade City,FL 33523 Phone:352-523-2077 ° i ' • i For: Sunrise Manufacturing Inc Fort King&Eiland Blvd, Zephyrhills, FL ��Zone: ,._,..:RR7: - �.� . °: �''-�`�.:.:_: ':=-:'�„- -:" � �.C.00LING;LOAD_: '";�._;�`--:�.: ;�-.;��:.-=;,; :_. - ,. ..-: __:,.-._ :. ; . . . .._ � 1. DESIGN CONDTTIONS at Aug 1700 LDT Peak load at Aug 1400 LDT Inside. 75 °F Outside: 92 °F TD: 17 °F RH� 56 % MoistDiff: 60.1 gr/Ib Mult: 1.0 Ins wb 63 °F Sensible Latent 2. SOLAR RAIDIA'PION'THItOUGH GLtLSS 0 - 3. TRANSMLSSIONGAINS Sensible 407 - Wal Is. 258 - - Glass: 0 - - Doors: 0 - - Partitions: 0 - - Floors 0 - - C eil i ngs: 149 4. IlvTERNALFIEAT GAIN Sensible Latent 213 0 Occupants: 0 0 - - Lights: 213 - - - Motors� 0 - - - Appliances 0 0 - - 5. INFILTRATION: Outside air cfm: 0 0 0 6. SUBTOTAL: Space load Sensible Latent 620 0 Envelope 620 0 - - Less external 0 - - - Redistribution 0 0 - - 7. SUPPLYDUCT 49 - 8. SUBTOTAL: Space load+supply duct 669 - Actual cfm: 34 at supply TD: 20 - - 9. VENTILATION: Make-up air cfm: 0 0 0 10. RETi7RKAIl2LOAD: Lighting+ plenum(net) 0 - 11. RETURI�TDUCT $ - 12. TOTAL LOAD5 ON EQUIPMENT 676 70 .., , _ _ :. _ =_.�__�.'..::�. : • _:. - � - -- - - - - - . ._ > ._ _ : =:, .,. . . _ , .; - -. -...:�..: � ,.__ . ;- - , ,.,-, , , . . .,, °- :... _:�HEATING;LOi4D�..;,:.; .,._--:_-.,---...;: '���:, :_ �. ���`_.; _.;: -_._. "� - 13. DESIGNCONDITIONS Mult: 10 Inside: 70 °F Outside: 43 °F TD: 28 °F 14. TRANSMISSION LOSSES 1470 Walls� 229 - Glass: 0 - Doors: 0 - Partitions. 0 - Floors: 209 - Ceilings: 1032 - 15. INFILTRATION: � Outside air cfm: 0 0 16. SiTBTOTAL: Space load 1470 Envelope 1470 - Less external 0 - Less transfer 0 - Redistribution 0 - 17. SUPPLYDUCT: 249 18. VENTILATION: Make-up air cfm: 0 0 19. HUA�II'ICATION 0 Piping � 20. RETURNDUCT 27 21. TOTAL HEATING LOAD ON EQUIl'MENT 1746 2Q74-May-19 14:34:26 '�?�' !A/i'I�fl'�SO'�" Ri htSUite�Universal 2013 13,0.11 RSU07440 g Page 10 File\C0514158-Buildouts Typica�C0514158.rup Calc=MN5 Building Front faces: W �" wrigkltS�ft� Right-Suite� Universal 2073 Load Surnro�ary Job: C0514158 Date: May 12,2014 /Zf�s By: TMN , � Randy Wa#son Designs inc 13821 US Hwy 98,Dade City,FL 33523 Phone:352-523-2077 �' � ' • @ For: Sunrise Manufacturing Inc Fort King& Eiland Blvd, Zephyrhilis, FL .. . ..- ._:-. - _ - - - _ .--_. _.:. -. . ,. . ... _. ,. . . .. . _ �_..Zone:� ,: RR"8_ . .:. .:,. .., : -.;--- ;>,:-`.COOLIf1tG`LOAD-... __.:_:= -: _. ..-:_. � :- _�:=L„ _ �_ _. �. -- 1. DESIGN CONDTTIONS at Aug 1700 LDT Peak load at Aug 1400 LDT Inside: 75 °F Outside: 92 °F TD: 17 °F RH: 56 % MoistDiff� 60.1 gr/Ib Mult: 1.0 Ins wb 63 °F , Sensible Latent 2. SOLAR RADIA�ION THROUGH GLASS 0 - 3. TRANSNIISSIONGAINS Sensible 354 - Wal Is: 224 - - Glass� 0 - - Doors. 0 - - Partitions: 0 - - Floors: 0 - - Ceilings. 129 4. INTERNAL�IEAT GAIlV Sensible Latent 185 0 Occupants: 0 0 - - Lights: 185 - - - Motors: 0 - - - Appliances 0 0 - - 5. INFII,TitATION: Outside air cfm: 0 0 0 6. SUBTOTAL: Space load Sensible Latent 539 0 Envelope 539 0 - - Less external 0 - - - Redistribution 0 0 - - 7. SUPPLYDUCT 42 - 8. SUBTOTAI.: Space load+supply duct 580 - Actual cfm: 30 at supply TD: 20 - - 9. VEN'TILATION: Make-up air cfm: 0 0 0 10. RET�7RNAIRLOAD: Lighting+ plenum(net) 0 - 11. RE TURN DUCT 6 - 12. TOTALLOADS ONEQUIPMENT 587 66 :, :, _ . . _._.._. .._....._.::_.. . . _ , _ �-_:=,.-:. . _ , _: : - , _,�:::_._,:.�. _. �, . . _ � _ _ _ _, ,. �. : . .:.. .: _ _.. .. .: , ;_;_,:,.. _.. _._ _.,.�;_ .:._�FiEATING_LOAD° _.` " _ 13. DESIGN CONDITIONS Mult: 1.0 Inside: 70 °F Outside: 43 °F TD: 28 °F 14. '�I2ANSMISSYON LOSSES 1278 Walls: 199 - Glass: 0 - Doors: 0 - Partitions: 0 - Floors: 181 - Ceilings. 898 - 15. INFII.TY2A'PION: Outside air cfm: 0 0 16. SUBTOTAL: Space load 1278 Envelope 1278 - Less external 0 - Less transfer 0 - Redistribution 0 - 17. SIJPPLYDiTCT: 197 f8. VENTII,ATION: Make-up air cfm: 0 0 19. IEIiTD'IIDIFICATION 0 Piping 0 20. RETURIVD�TCT 20 21. TOTALHEATIlOTGLOADONEQUIPMENT 1495 2014-May-19 14:34:26 1JV1'Ig�'t'CSS9'�" RightSuite�Universal 2013 13.0.11 RSU07440 Page 11 File1C0514158-Buildouts Typical\C0514158.rup Calc=MN5 Building Front faces: W � Right-Suite� Universal 2013 Load Sumrnary Job: C0514158 � �/NI°1��its�ft Date: May 12,2014 UniL'4 By: TMN � ' Randy Watson D�signs Inc 13821 US Hwy 98,Dade City,FL 33523 Phone:352-523-2077 • � ' • a For: Sunrise Manufacturing Inc Fort King&Eiland Blvd, Zephyrhills, FL __ _ ._... .. - ..,. - - - . : _ :._._ _. ,.. : - . .:: : ._- _ - _ _ = �:�:. ., .. .� ==_:-_ _ `_ . -,.;, >. :,-,Zone:- =_Unit.4:,:. ::,; ,:.:.:�:.._:;.��.:� _ .::: , ::._:-:_:.._:_:_::� COOLiNG:LOAD:, �. _ �::.�. :::_._; =,. :_.,: _ � .. 1. DESIGN CONDTTIONS at Aug 1700 LDT Peak load at Aug 1700 LDT Inside: 75 °F Outside: 92 °F TD: 17 °F RH: 56 % MoistDiff: 60.1 gr/Ib Mult: 1.0 Ins.wb 63 °F Sensible Latent 2. SOLAR 1�ADIATION THROUGH GLASS 16786 - 3. TRANSMLSSIONGAINS Sensible 6214 - Wal Is. 1518 - - Glass: 1648 - - Doors: 214 - - Partitions� 0 - - Floors. 0 - - Ceilings: 2833 4. YNTERNALgdEAT GAIN Sensible Latent 7382 2800 Occupants 3325 2800 - - Lights. 4057 - - - Motors: 0 - - - Appliances. 0 0 - - 5. INFILTRA'�ION: Outside air cfm: 0 0 0 6. SUBTOTAL: Space load Sensible Latent 30382 2800 Envelope 30382 2800 - - Less external 0 - - - ' Redistribution 0 0 - - 7. SUPPLYDUCT 2311 - 8. S�IBTO'�AL: Space load+supply duct 32693 - Actual cfm: 1597 at supply TD� 20 9. VENTII.ATION: Make-up air cfm: 175 3190 7154 10. RETURNAIlt LOAD:_ Lighting+ plenum(net) 0 - 11. RETLTRNDUCT 367 - 12. TOTAI,LOADS ON E QUIPMENT 36251 11321 �. - _� .- ,_.- ::--: .:_.... :...:.::. ;:.. , _.... .. . . , _. .. _ - . .- - -_- -- „ _ _ . _ . .._ ,. _ .. . _ _ � =-.. :- :�_:HEATtNG_tOAD_:- =° :-_:`___,�_:::-��;. ='=:<�;_�_ .: �-=� _ ._= 13. DESIGNCONDTTIONS Mult: 1.0 Inside: 70 °F Outside: 43 °F TD: 28 °F 14. TRANSIVIISSION LOSSES 18253 , Wal Is 1438 - Glass 2920 - Doors. 193 - Partitions: 0 - Floors: 1559 - Ceilings. 12143 - 15. INFILTRATION: Outside air cfm: 0 0 16. SUBTOTAL: Space load 18253 Envelope 18253 - Less external 0 - Less transfer 0 - Redistribution 0 - 17. SUPPLYDiTCT: 3175 18. VENTI�ATION: Make-up air cfm: 175 5293 19. �IUNIIDIFICATION 2118 Piping � 20. RETURNDUC'I' 351 21. TOTALHEA'I'INGLOADONEQUIPMENT 29190 2014-May-19 14:34:26 rrvm°ightso�it" RightSuite�Universal 2013 13.0.11 RSU07440 Page 12 File\C0514158-Buifdouts TypicallC0514158.rup Calc=MN5 Building Front faces: W �" wright�Oft� Right-Sui#e� Universal 2013 Load Summary Job: C0514158 Uni�5 Byte: MMaN12,2014 ' Randy Watson Designs Inc 13821 US Hwy 98,Dade City,FL 33523 Phone:352-523-2077 ° S ' • i For: Sunrise Manufacturing Inc Fort King& Eiland Blvd, Zephyrhills, FL - . _ . ... _.. �. . _ -.- - . ., -.--._ ....._. . = . - . Zone: .-.:;Unit�S._� �.:`.:.:._=:.__ _, ., _ -.;__:�;-.�_:.:=- :�`'::C.00LING"LOAD.:':.-_-=`-�-:':===-=,:_:=-::.�.'-.'- _:=-.. ._=_ ::- `.` _`:. ``=:-� -.;•_..� 1. DESIGN CONDTTIONS at Aug 1700 LDT Peak load at Aug 1700 LDT Inside: 75 °F Outside: 92 °F TD� 17 °F RH� 56 % MoistDiff: 60.1 gr/Ib Mult: 1.0 Ins wb 63 °F Sensible Latent 2. SOLAR RADIATION THROUGH GLASS 16786 - 3. TRANSNIIS5IONGAINS Sensible 6146 - Walls. 1473 - - Glass: 1648 - - Doors: 214 - - Partitions 0 - - Floors. 0 - - Ceilings: 2810 - - 4. INTERNALHEAT GAIN Sensible Latent 7350 2800 Occupants: 3325 2800 - - Lights: 4025 - - - Motors: 0 - - - Appliances 0 0 - - 5. INFII,TRATION: Outside air cfm: 0 0 0 6. SUBTOTAL: Space load Sensible Latent 30282 2800 Envelope 30282 2800 - - Less external 0 - - - Redistribution 0 0 - - 7. SUPPLYDUCT 2321 - 8. SUBTOTAL: Space load+supply duct 32603 - Actual cfm: 1608 at supply TD: 20 - - 9. VENTILATION: Make-up air cfm: 174 3175 7120 10. RETURNAIRLOAD: Lighting+ plenum(net) 0 - 11. RE TURN DUCT 370 - 12. TOTALLOADS ONEQUIPMENT 36148 11287 : � , :. _ - - -,: - - - -- - � _ -::HEATIIVG.LOA►D�`_=-� - :-_- - .. - - --- --. _ - - _ - ,_-_ :-- - 13. DESYGNCONDTTIONS Mult: 1.0 Inside: 70 °F Outside: 43 °F TD: 28 °F 14. TRANSNIISSION LOSSES 18080 Wal Is: 1398 - Glass: 2920 - Doors: 193 - Partitions: 0 - Floors: 1523 - Ceilings: 12046 - 15. INFILTRATION: Outside air cfm: 0 0 16. SUBTOTAL: Space load 18080 Envelope 18080 - Less external 0 - Less transfer 0 - Redistributlon 0 - 17. SU�'PLYDUCT: 3166 18. VENTILATION: Make-up air cfm: 174 5268 19. HiTD�IFICATION 2108 Piping 0 20. gtETURN DUCT 351 21. TOTALHEATINGLOADONEQUIPIVI�NT 28972 �- wrightsoft" 2014-May-1914:34:26 RightSuite�Universal 2013 13.0.11 RSU07440 Page 13 File\C0514158-Buildouts Typical\'C0514158.rup Calc=MN5 Building Front faces: W Right-SuiteO Universal 2013 Load Sumrnary Job: C0514158 '�'�"�WI'19�tSOftW Uni�6 Byte: MMaN12,zo�a � " Randy �Vatson Designs inc 13821 US Hwy 98,Dade City,FL 33523 Phone:352-523-2077 e 0 ° 0 0 For: Sunrise Manufacturing Inc Fort King& Eiland Blvd, Zephyrhills, FL ,.. . ., ,. .... :.,. _. .: - - - __ - - - - Zona::� ,>:-:Unit,6`.;,_,�:..,.;��:,.:.�. �-.,_�,.::�.= =._ =>.` :' ,..:°.-COOLING-LOAD� ::=:': :.:.;-.,=;__.: ._ '_. -..� . ..- -_. . �_. :. „ 1. DESIGN CONDTTIONS at Aug 1700 LDT Peak load at Aug 1700 LDT Inside: 75 °F Outside: 92 °F TD: 17 °F RH: 56 % MoistDiff: 60.1 gr/Ib Mult: 10 Ins.wb 63 °F Sensible Latent 2. 50LAR RAD�ATION THROUGH GLASS 16786 - 3. Ti2ANSMISSIONGAINS Sensible 6599 - Wal Is: 1692 - - Glass. 1648 - - Doors: • 214 - - Partitions: 0 - - Floors: 0 - - " Ceilings� 3044 - - 4. IN'TERNALHEAT GAIN Sensible Latent 7209 2400 Occupants: 2850 2400 - - Lights: 4359 - - - Motors: 0 - - - Appliances. 0 0 - - 5. INFILTRATION: Outside air cfm: 0 0 0 6. SUBTOTAL.: Space load Sensible Latent 30594 2400 Envelope 30594 2400 - - Less external 0 - - - Redistribution 0 0 - - 7. SIJPPLYDUCT 2403 - 8. SUBTOTAL: Space load+supply duct 32997 - Actual cfm: 1604 at supply TD: 20 - - 9. V�NTILATION: Make-up air cfm: 173 3150 7065 10. RETURNAIItLOAD: Lighting+ plenum(net) 0 - 11. RETURNDUCT 381 - 12. TOTAL LOADS ON EQIIIPMENT 36528 10881 �. :. .. - - :- ,. , .._�, .:� :. : ..... ... .: _ _ _ . ,___ . _ - , :. . ., _ .-. . , . �_ : = _- :::, :... : ° :_":HEATING:LOAD: :;- ;_ -:;:_==�:._.=::_==_`- :,� '._::`..:_ _�.._ "_ "--_._ - � 13. DESIGNCONDTTIONS Mult: 1.0 Inside: 70 °F Outside: 43 °F TD: 28 °F 14. '�RANSMISSION LOSSES 19460 Walls. 1613 - Glass 2920 - Doors: 193 - Partitions: 0 - Floors: 1686 - Ceil i ngs: 13047 - 15. INFILTRATION: Outside air cfm: 0 0 16. SITBTOTAL: Space load 19460 Envelope 19460 - Less external 0 - Less transfer 0 - Redistribution 0 - 17. SUPPLYDUCT: 3284 18. VENTILATION: Make-up air cfm: 173 5227 19. HUN�IFICATION 2092 Piping 0 20. YtETUI2NDUC� 361 _ 21. TOTALHEATINGLOADONEQUIPMENT 30423 �'�'-�" diVr'1��'1'tS0'�ro RightSuite�Universal 2013 13.�.11 RSU0744D 2014-May-19 14:34:26 Page 14 File\C0514158-Buildouts Typica�C0514158.rup Calc=MN5 Building Front faces: W Right-Suite� Universal 2013 Load Summary Job: C0514158 �" WI'19��SO�`� Un%f,7 Byte: MaMN12,2014 � ' Randy �lVatson Designs Inc 13821 US Hwy 98,Dade City,FL 33523 Phone:352-523-2077 ° 8 ' � • For Sunrise Manufacturing Inc Fort King&Eiland Blvd, Zephyrhills, FL �. .- . ; -. _ .. , - ,, .- - - - - Zone; -:. Unif.7 :. -- _ : ` ; -_,. . • CQOLING LOA.D".,.. -_ � .- : - - � _ �_-,: . .: ._�_ - --.._ . 1. DESIGN CONDTTIONS at Aug 1700 LDT Peak load at Aug 1700 LDT Inside: 75 °F Outside: 92 °F TD: 17 °F RH: 56 % MoistDiff� 60.1 gr/Ib Mult: 1.0 Ins.wb 63 °F Sensible Latent 2. SOLAR RADIATION THROUGH GLASS 16786 - 3. TRANSIVIISSIONGAINS Sensible 6461 - 1Nal Is. 1634 - - Glass. 1648 - - Doors. 214 - - Partitions: 0 - - Floors: � 0 - - Ceilings. 2965 4. INTERNALHEAT GAIN Sensible Latent 7096 2400 Occupants 2850 2400 - - Lights. 4246 - - - Motors. 0 - - - Appliances 0 0 - - 5. INFII,TRATION: Outside air cfm: 0 0 0 6. SUBTOTAL: Space load Sensible Latent 30343 2400 Envelope 30343 2400 - - Less external 0 - - - Redistribution 0 0 - - 7. SUPPLYDUCT 2387 - 8. SUBTOTAI,: Space load+supply duct 32730 - . Actual cfm: 1599 at supply TD: 20 - - 9. V�NTILATION: Make-up air cfm: 170 3097 6945 10. ItE'�URNAIRLOAD: Lighting+ plenum(net) 0 - 11. RETURNDUCT 380 - 12. TOTALLOADS ON EQUIPMENT 36206 10735 _ .�. ., � .: _ .. _, : -, . ,_.._. . ._HEATIN�LOAD.��,�.�_. ,,:=,;==;,.,::`�::_`- . -- .. . - , ;. 13. DESIGNCONDd'I'IONS Mult: 1.0 Inside: 70 °F Outside: 43 °F TD: 28 °F 14. TRANSNIISSIONLOSSES 19020 Wal Is: 1558 - Glass: 2920 - Doors: 193 - Partitions� 0 - Floors: 1641 - Ceilings: 12707 - 15. INFILTRA�ION: Outside air cfm: 0 0 16. SU�TOTAL: Space load 19020 Envelope 19020 - Less external 0 - Less transfer 0 - Redistribution 0 - 17. SLJPPLYDUC'Y': 3217 18. VENTILATION: Make-up air cfm: 170 5138 19. HiT11�IFdCATION 2056 Piping 0 20. RETgJRN DYTCT 355 21. TOTALHEATINGLOADONEQUIl'MEPTT 29785 " � 2014-May-19 14:34.26 ��" WI'Igfl't50'�` RightSuite�Universal 2013 13.0.11 RSU07440 Page 15 File1C0514158-Buildouts Typical\C0514158.rup Calc=MN5 Building Front faces: W � � Right-Suite� Univers�i 2013 Load S�ammary Job: C05i4158 � VI/rl��ts0�� Date: May 12,2014 * �l/I%1'$ , By: TMN ' Randy Watson Clesigns Ina 1382i US Hwy 88,Dade City,FL 33523 Phone:352-523-2077 ° • ' i i For: Sunrise Manufacturing Inc Fort King& Eiland Bivd, Zephyrhills, F� <:;Zone:: °.,Unit 8_'�.:�.;�'` ". ,. . _ .. , � . �:-COOLIN.G�LOAD -}�-�� =. : . , . .. . _ : _.. 1. DESIGN CONDITIONS at Aug 9704 LDT Peak load at Aug 1700�DT Inside. 75 °F Outside: 92 °F TD� 17 °F RH. 56 % MoistDiff: 60.1 gr/lb Mult: 1.0 Ins wb 63 °F Sensible Latent 2. SQ)LAR I2ADTATION THROUGFI GLASS 16786 - 3. TRANSMLSSI�N GAIN�S Sensible 7233 - Wal[s: 2654 - - Glass. 1648 - - Doors: 214 - - Partitions: 0 - - Floors. 0 - - Ceilings. 2717 - - 4. IlV'TERNAI.FIEAT GAIN Sensible 1_atent 6503 22Q0 Occupants. 2613 2200 - - Lights. 3891 - - - �llotors 0 - - - Appliances� 0 0 - - 5. INFILTR,�TIC►1�1: Outside air cfm: 0 0 0 6. SUBTtI►TAL: Space laad Sensible �atent 30523 2200 Envelope 30523 2200 - - Less external 0 - - - Redistributian 0 0 - - 7. S�JJPPLYDUCT 2352 - 8. SUBTOTAL: Space load+supply duct _ 32$75 - Actual cfm: 1593 at supply TD: 20 - - 9. VENTILATIOIV: Make-up air cfm: 156 2838 6366 10. ItETURNAIIt LOAD: Lighting+ plenum{net) Q - 11. RETUI2NDUCT 367 - 12. 7COTALLOADS ON EQUIFIVIENT 360$0 9952 '.. . ' . -, - � __ .. _ . , -- _. �:�_NEATING:�OAD;��:.;:. °:�:;;":,.;_=>>.;,-_;` .:; ,z. _ ; :___. :: __.:,; ,':: :. � 13. DESI�NCONDITIONS Mult: 1_Q 1 nside: 70 °F Outside: 43 °F TD: 28 °F 14. TRANSIVIISSIONLOSSES 21385 Walls: 3534 - Giass 2920 - Doors: 193 - Partitions. 4 - Floors: 309'f - Ceilings: 11646 - 15. Tl�'II.TRATION: Outsids air cfm: 4 0 16. SITBTt3TAI.: Space load 21385 Envelope 21385 - Less external 0 - Less transfer 0 - Redistrib'ution 0 - 17. SUI'PLYDUCT: 3287 18. VENTILATICAt�T: Make-up air cfm: '156 4709 19. IIiTMIT)IFICA'TION 1884 Piping Q 20. RETURNDU+CT 342 21. TOTALHEATYNGLOADONEQUIPMENT 31608 "E-" �r�g������' Ri htSuite@ Universa12d73 13.d.S1 RSUQ7440 2014-May-19 14:3426 9 Page 16 File1C051415$-Buildouts TypicanC0514158.rup Calc=MN5 Building Front faces: W I I