Loading...
HomeMy WebLinkAbout14-15402 CITY OF Z PHYRHILLS � - 5335-8t Street • � (813)7 0-0020 � 2 ELECTRIC L PERMIT Parmit#:'15402 Issued: 6/'17/20'14 i Address: 40343 AIRTIME AVE Parmit Typ@_ ELECTRICAL MISC i ZEPHYRHILLS, FL. Class of Worlc: ELECTRIC SERVICE/NEW Towr�sF�ip: Range= Proposad Use= NOT APPLICABLE Lot(s)= Blocic= Sectio�: Sq_ Feet: Est_ Valu6: Boolc: Pagg: Cost= 35,000.00 Total Faes: 3'15.00 Subdivision: ZEPHYRHILLS COLONY Amount Paid: 3'15_00 �ata Paid= 6/'17/20'14 Parcel Number: 18-26-22-00'10-04400-0000 Namg= MAY ELECTRIC Nam@= URAGALLO. TONY Addr= 'I'1039 KITTEN TRAIL Address= 5334 FRONTIER �R HU�SON FL 34669 ZEPHYRHILLS. FL. 33547 PF�onec (727 8'19-2862 Licc PI-�or�e= (8'13)788-4753 -_ Work Ues�= SOLAF2 PANEL INSTALL ROOF MO NT ELECTRICAL FEE 3�5.00 II � � ' � ROUGH ELECTRIC CONSTRUCTION POLE PRE-METER FINAL �� �� � ay` � 1 Q��G ` C ! REINSPECTZON FEES= Reinspection Pees wi11 �omply w tF� F�orida Statute 553.80(2)(c)when extra inspection trips are necessary due to any one of the following re sons: a�wrong address b) oondemned worlc resultlng from faulty construction c� repairs or corrections n t made wF�en inspection ca�led d�work not ready for inspection wF�en called e� permit not posted on jo site� p�ans not at job site g)worK not ac�essible. NOTICE: In addition to the requirements of this permit, ther may be additional restrictions applicable to this property that may be found in the public records of tF�is county, and there may be additional permits required from other governmental entities such as water manageme��, state agencies or Federal agencies. °Warning to owner: Your t'aiiure!o recoM a notice f commencement may result in your paying Ywice for improvements to your property. If you intend to ob in financing� consult with your lender or an altorney before recording your n tice of oommen�ement." Complete Plans,�Speciflcations and Fee Must Accompany Ap lication_ All worlc shall be pertormed in accordance witti City _ _ __ Codes andl Ordinances. __ I �\ I 1 � � I CONTRACTOR ''� PER OF 1 PERMIT EXPIRES ZN 6 MONTHS �ITHOUT APPROVE� INSPECTIO CALL FOR INSPECTION HOUR NOTICE REQUIRE� PROTECT CAR��FROM WEATHER I 1 c'�.,� .� , � c� rd ��� ��S�. �� � 1 1� C?�Ok� Gtl�a /�u�fev �� �a City of ephyrhills ,^�o,�m,j� ,.;? �� � BUILI7ING PLAN VIEW COMMENTS �J �Y �,rsr�/'� �u�� ' Contractar/Homeowner: � °c.��f� u ���'�� ���� Date Received: �O --����-` � ���� s �; {� � Site: �i'7 3 ���. ���.�`�'�-�,. Permit Type: ,.� �f ��' ,�� I i Approved w/no concaments: Approved w/the below camments: ❑ Denied w/the belaw comrnents: O I � � � � i E � i This comment sheet sha11 be kept with the permit and/ar�lans. � • JUN � 7 2014 � i e�:�� ,.��4,c.�i� � � Ka�vin Switzer—Plans Examiner Date Contractor and/or Hameowner � (Required when comments are present) 'i a�saeo-oozo City of Zephyrhills Permit Applicatio Fax-813-7 02� Buildin�Department I ' Date Received _ � Phone Contact fo Permittin -- Owner's Name r (.�� (� li Owner mber Owner's Address °3 e Owner Phone Number � Fee Simple Titleholder Name Owner Phone Number �— Fee Simple Titleholder Address JOB ADDRESS U � �� i 1(�` �,�' LOT# C� SUBDIVISION PARCEL D# � � �' �(p (7 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED � NEW CONSTR e ADD/ALT Q SIGN Q Q DEMOLISH INSTALL REPAIR PROPOSED USE Q SFR Q COMM Q OTHER TYPE OF CONSTRUCTION Q BLOCK Q FRAME [� STEEL Q DESCRIPTION OF WORK `� BUILDING SIZE SQ FOOTAGE HEIGHT QBUILDING a VALUATION O TOTAL CONSTRUCTION �ELECTRICAL $ � AMP SERVIC [� PROGRESS ENERGY Q W.R.E . C.�Dz l�s �� QPLUMBING $ � CS ` �Q�,�, ,�,(�-(„S� ��, ��--� �(�'`��,,'p G� QMECHANICAL $ VALUATION O MECHANICAL INSTALLATION C�. ,,�afp�M�" V �'v � ��e QGAS Q ROOFING Q SPECIAL Q OTHER .� (�(� � I '� L/� FiNiSHED FLOOR ELEVATIONS FLOOD Z NE AREA QYES NO � � � � BUILDER COM ANY SIGNATURE REGIS RED Y/ N FEE CURRE� Y/N Address License# ELECTRICIAN , ��` COM ANY � I l(,l.X ��C SIGNATURE REGIS ERED Y I N FEE CURRE� Y/N Address License# 5 J PWMBER � COM ANY SIGNATURE � REGIS ERED Y/ N FEE CURRE� Y/N Address License# MECHANICAL COM ANY SIGNATURE REGIS ERED Y J N FEE CURRE� Y/N Address license# � OTHER COM ANY SIGNATURE REGIS ERED Y/ N FEE CURRE� Y/N Address License# RESIDENTIAL Attach(2)Piot Plans;(2)sets of Building Plans;(1)set of nergy Forms;R-O-W Permit for new construction, Minimum ten(10)working days aRer submittal date. Req ired onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Fadlitles&1 dumpster;Site Wo�lc Petmit fo�sub ivisfonsAarge projects COMMERCIAL Attach(3)complete sets of Build(ng Plans plus a Ufe Safeky Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days atter submittal date. Req�ired onsite,Constructlon Plans,Stormwater Plans wl Silt Fence installed, Sanitary Facilities 8 1 dumpster.Site Wor1c Permit for ali niew projects.All commercial requirements must meet compliance 31GN PERMIT Attach(2)sets of Engineered Plans. •'""PROPERTY SURVEY required for all NEW constructiqn. Directions: I Fill out appiicaHon completely. I Owner&Contractor sign back of application,notarized I If over 52500,a Notice of Commencement is required. (AIC upgrad�s over=7500) "" Agent(for the contractor)or Power ot Attomey(for the ovmer)would be�omeone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (Front of Application Only) Reroofs if shingles Sewers Service Upgrades A/C Fences(Pibf/Survey/Footage) Driveways-Not over Counter if on pubiic roadways..needs ROW � �I I�i I IIIIII IIII)IIIII II�II IIIII IIII'IIII�(IIII IIIII IIIII IIII II�I � 2014092052 • III Rept:1608524 Ree: 10.00 DS: 0.00 IT: 0.00 PermitNumber I 06/09/14 L. Seria, Dpty Clerk Parcel ID Number _� _ �D ���— �—V�'(�j� — C1 b� C7 PAULA S 0'NEIL Ph D PRSCO CLERK & COMPTROLLEk NOTICE OF COMMENCEMENT 06/09/14 01:09 m 1 of 1 State of Florida OR BK ���3 P� 1716 County of Pinellas THE UNDERSIGNED hereby gives notice that improvements will be m de to certain real property, and in accordance with Section 713.13 of the Florida Statutes,the following information is provided in this NOTICE OF OMMENCEMENT. 1.Description of property(lega/description): a)Street�job)Address: �Q�1.�'� �� ��p v� �Q, • � �l 2.General description of improvements: V �,Zt � (; - �v � —��n �—°,------ 3.Owner Information or Lessee information if the see co tracted or th improvement; 1��,�� ��. �� ,-ey� � � ;�15 P � 3 3��i c� a)Name and address: �r7j �'�jj � �,('. . b)Name and address of fee simple titleholder(if different than Owner�listed above) c)Interest in property: ����Q� 4.Contractor Information i a)Name and address: William May Inc. May Electric b)Telephone No.. 727-819-2862 I Fax No..(optional) 727-279-2808 S.Surety(if applicable,a copy of the payment bond is attached) t a)Name and address: b)Telephone No.. c)Amount of Bond: $ ^ 6.Lender a)Name and address: b)Telephone No.: 7.Persons within the State of Florida designated by Owner upon wh m notices or other documents may be served as provided by Section 713.13(1)(a)7.,Florida Statutes: aj Name and address: b)Telephone No.: Fax No.:(optional) 8.a.ln addition to himself or herself,Owner designates of to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. b)Phone Number of Person or entity designated by Owner: 9.Expiration date of notice of commencement(the expiration date ma not be before the completion of construction and final payment to the contractor,but will be 1 ear from the date of recordin unless a differ nt date is s ecified: ,20 � WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER A TER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE � CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713,PART ,SECTION 713.13, FLORIDA STATUTES,AND CAN RESULT IN YOUR ; PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NO ICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON ; THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEN TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ; ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR OTICE OF COMMENCEMENT. _,j Under penalty of perjury,I declare that I hav rea e foregoing notice of ommencement and that the facts stated therein are true to the best of my knowledge and belief. _�� r� _.. � . � �ga � o (Signature of Owner or Le e,or s or Lessee's Authorized OfficedDirectodPart�edManager) (Print Name and rovide Sgnatory's TiUe/Oifice) The foregoing instrument was acknowledged before me this �l �, day of ,20' _ by (.,Q_�� 2S QI,U�) (type of authority,e.g.officer,Vustee,attorney in fact) for —._.�.�_c;_--- �----- ------ E�-as—I----i— --- ,J � (Name of Person) (type of authority,. e.g officer trustee,attorney in fact) for (na e of party on behalf of whom instrument was x uted). P rs na I o n Froduced ID ❑ T e�Q, p,,,,_��� Notary Signature r - � 'rs Notary Pubtic-Shte ot F1orw� Print name '�, _ • .•=Nry Comm.Expires Jm 31,2017 , s��.r Commiision�Ef 866092 ��N�'` BonOed TMoupA N�tion�l NWuy Assn. �, I�, I � I � . , II ' I MAY ELECTRIC I WILLIAM MAY INC. � OFFICE 727-819-2862 'i FAX 727-279-2808 LIC# EC13005353 MAYELECTRIC NET/ I William May authorize Shannon ay dob 11/10/1973 to appiy for permits as an authorized agent in he city of Zepherhills. � � z William �Vlay � � � 1� - -�G 1 / � � � � I I Celia B. Vincent '°� ° �� '� C01"�'°' �� Y �0�� Y PUe�i Notary Public n � State of Florida � ' � ��F . � �s���e Commission # EE 199078 � Fxoires: June 18, 2016 I I � i � � � I � � � �� i . , ' i �, I II II � • � , " ..5�.<. Ct,k: � � ' .. : .. � '�i}3:a ,. � ';1 . �:�K'?� . ����I����������t�5 �'�`;� C� ��o�c� . . ., m��. ��,�.tu r.�oa � � : TUV Power tontrolled. � �"",�,��-;�,:~�"°`°"�� = _ .uvRne�nia�a � Lowest measuringtoierance in industry i * � : � .o ,�,` 000002°' ( Every component is tested ta meet j 3 times IEC requirements {�����+�f.1Z�"? �/ j'E REVIEW D�TE � oesignedtowithstand�ei�/ OF G'`.EPHYR ��..L accumulations of snow and ice ..� . � P��iNS EXAMINE � Sunmodule Plus. .� Positive perfarmance tolerance ,„ � � �,,�,�k�L t`y��,t� �1T ( '�,�:L'�i.�r't �',i.i,i° , 1t�.U, � ` �( �,; �;1 t}��11�i LTv r F>�r:�'.'��L�;�:C�C�� �'� �� - `t��) � �,i��i� `` �,�)`�.'.,-'�,`' 1 1 t' i.l\ ��*',:1 25-year linear perfoFm�f�'w�Kt�n# �rn'jlLl,,�V: V and 10•year produci(yv�rda�}r ��"���` J N4TICE,/"` 1�� Glass with anti-r�i�� �1���� m�4y {�� p . � prev�iiing d far buil ing, .. p{umpin�, e�� I, mec anical, _ _ � ,,, � Wartd-tlass quality ���� �j � ��� " ,,,,,,,,,.., _�,.�,:,�� _ Fully-automated productiar;,,,f(�nd sea I ni�anng of the rocess nd material �'�� .`.: ;",.�'' ' +� �; ;,"°'`� ,e .,.,,.�t,,��..:..:, ensure the quai+ty that the campany sets as its benchmark far its si es woridwide. `�� "'� " � V �� SolarWorld Plus-Sorting j /""�"'\ , J��;' P1us-Sorting guarantees highest system efficsency SolarWorld anly�lelivers madules that �� " _ �:_ have greater than or equal to the nameplate rated power I � u�t7�3 25 years Einear peeformance guarantee and extension af product arranty to 10 years � � , .{,�; SolarWorld guarantees a maximum performance degression of 0 7 o p.a.in the course of ZSyears,a significant added value campared to the twa-phase warr nties common in the industry In additian,SolarWortd is affering a praduct warranty,whi�h has been extended to 1Q years` i I 'in aaordance with the appiicabie SoiarWarid limited warranty at purchase. i wwwsolarworld.com/warranty I I ' SOLARWORLD � �...��/ Cl)�IT T'��'S solarworid.com I �+ � We turn sunlight into pawer. � V I � I � , .� � Sunmodule,�'Plus SW 2�0 mano { � PERFORMANCE UNDER STANDARD TE5T CONDITIONS(STC)' PERFORMANCE AT 8Q0 W/m=,NOCT,AM 1.5 I Maximnm power P 280 Wp I Maximum power Pm 209.2 Wp Open circuit voltage Vm� 39.5 V I Open rircuit voltage V,Y 36.1 V Maximum power paint vo/tnge Vm� 311 V I Maximum power point voltage Vmoo 28.5 V Shortci�cuitcunent is� 9.71A Shorttircurtcu�renf I� 7.85A Moximum power point cunent Im 9.07 A Maximum power point current Impp 733 A '$TC IOQQ Wjm�.25'C,AM 15 Mmar reducUOn�n eff�ciency under partial ioad mnd�UOns at 25°C.aY 2Q0 WJm�i0p%i 1�Measunng tolerance(P,a,)traceable to TUV Rheinland:+/-2%(TUV Power Controlled) (*I-2%)of the STC efficienty(1000 Wjm�}is achreved � COMPONENT MATERIALS THERMAI CNARACTERI5TItS Cells per module BO NOC7 46°C �eft type Mona crystalline 7t/ O.OA f J°C Cetldimensionx 6.14 in x 6.14�n(156 mm x 15b mmj TC�� -0.30%/°C Front Tempered glass(EN 12150) TCPm -0.45%J°C Frome Clearanodizedaluminum Operatiny temperqture -40°C to 85°C I �ye�yht 46.7 Ibs(21.2 kg) , SYSTEM INTEGRATION PARAMETERS � 1000 W/mz Maximum system voltage SC 11 1000 V Max.system vottage USA NFt lOdO V 800 W/m= Maximum reverse current 16 A Number of bypass diades 3 �a, 600 W/m� 173 psf downward u . -- UL Design Loads" Two rail syxtem 64 sf u ward p P 3 ���yN�2 174 psf downward = l Ut Design taads' 7hree rail s}ntem 64 sf u ward - P P „ .. _ � ZOOWfmz IECDesigrtLOads' 7worai(rystem 113p0�Sfunward p P 100 W�IT1z I 'Please refer tothe Sunmodule mstallation instructions for the detads assauated with these Inad cases. �Modulevoltage[VJ V� ADDITIONALDATA Powersarting' •0 Wp/+5 Wp 1 x 4 _��_—374A(951) J-Box .. ........ �. IP65 � _ __ _ � Module leads PV wire per U14703 with H4 connectors i Modute e�ciency 16.70% 71.33(Z88) Fire rqting(UL 79tl) Class C � Gtass Low iron tempered wlth ARC 4/30{7050) 0.6 753 Vervon VERSION 2,5 FRAME 2 5 frame • Compat�bie with both"TOp-Dawn" 65.94(1675) bottom � and"Bottom"mounting methods M mount�ng • �rGroundingLocations. holes � -4 corners of the frame ( -4(ocations along the Iength of the module in the extended flange+ �� 734 34 I I I -!-x 4 � �a.zo pm�+ ��' Independently created PAN files now available. "'�� �3941(1001}� Ask your account manager for more information. t zz(si) All umts provided are imperial.SI units prowded in parentheses. i SolarWorid AG reservestfie rigfit to make speuficat�on changes wdhout not�ce I SW-01-6006US 07-2014 II II -- ' � � II . , ' I Enphase�Microinverters En hase� M250 p �xr� f�� � � 5, -.� ' � �. 'i-M r! , � -,ar���`p=: _� �2 � � �; .� �_ m= . x:;^=. . s. . F � l4 The Enphase� M250 Microinverter delivers increa ed energy harvest and reduces design and installation complexity with its all-AC approach. Wit the M250, the DC circuit is isolated and insulated from ground, so no Ground Electrode Conductor GEC) is required for the microinverter. This further simplifies installation, enhances safety, and aves on labor and materials costs. The Enphase M250 integrates seamlessly with the ngage� Cable, the Envoy�Communications Gateway�", and Enlighten�, Enphase's monitoring a d analysis software. PRODUCTIVE SIMPLE RELIABLE -Optimized for higher-power - No GEC needed f r microinverter -4th-generation product modules - No DC design or s�ring calculation - More than 1 million hours of testing - Maximizes energy production required and 3 million units shipped - Minimizes impact of shading, - Easy installation with Engage - Industry-leading warranty, up to 25 dust, and debris Cable i years �� � � enphase� '�, s�� F N F R G Y � C US I�i • II ' i Enphase�M250 Microinverter//DATA � INPUT DA7A(DC) M250- 0-2LL-S22/S23/S24 Rscammended inpu#power{STC} 2i0-3 0 W Maximum input DC voltage 48 V Peak power tracking voitage 27 V- 9 V Operating range 16 V- 8 V Min/Max start voitage 22 V 1 8 V Max DC short c+rcuit current 15 A Max input current 9.8 A Ot1TPUT DATA{AC} f�208 AC �240 YAC Peak output power __ ._. .._._.._ ,___ .�..._ .a._�-a_ 250 W __,..._.___._....._.__..�,..250 W � . Rated(cantinuaus)autput power 240 W 244 W Nominal output current 1.15 A rms at nominal duration) 1.0 A(A rms at nQminai durationj Nomina!voltage/range 208 V 1183-229 V 240 V 1211-264 V Nominal frequency/range 60.0/ 7-61 Hz 60.0/57-61 Hz Extended frequency range` 57-62. Hz 57-62.5 Nz Power factor >q.95 >0.95 Maximum units per 2Q A branch circuit 24(thr e phase} 16{single phase) Maximum output faulf current 850 m rms for 6 cycles 850 mA rms for 6 cycles EFF{CIENCY CEC weighted efficiency,240 VAC �T� 96.5% � CEC weighted efficiency,208 VAC 96.0% Peak inverter efflciency 96.59. Static MPPT efficiency(weighted,reference EN50530) 99.4° Night time powsr consumption 65 m max MECHANICAL DATA __Ambien#temperature range �`._. ._,_..._._____ --�-- _40°C o+65°C ..._ _�. .._�__.....�._. ._____.,.�..._.__ ..._�.. Operating temperature range(internal) -40°C to+85°C Dimensions(WxHxD} 171 rrr x 173 mm x 30 mm{without mounting bracket} Weight 2.0 kg Cooling Natur I convection-Na fans Enclosure environmental rating Outd or-NEMA 6 FEA7URES Compatibility � �� Com tible with 60-celi PV modules. Communication Powe line Integrated ground The circuit meets the requirements for ungrounded PV arrays in NEC 90.35.Equipment ground is pravided in the Engage Cabte.No additipnai GEC or ground is required. Monitaring Free I fetime manitoring via Enlighten saftware Compliance UL17 1/IEEE�547,FCC Part 15 Class B,CAN/CSA-C22.2 NO.0-M81, 0.4-0 ,and 107.1-01 `Frequency ranges can be extended beyond nominal if required by the utility To learn more abaut Enphase Microinverter technolog�r, ��'1 haS�� visit enphase.com 1 � � = N� � G v i a 2Q13 Enphase Energy.Aii rights reserved.Aii trademarks or brands in this docume�t�re rec�istered by their respec#ive pwner. I ( I i � ' � � �7 L� � .�"� �� � � INC. Engineering and Design Services 3662 Avalon Park East Blvd.Suite 2072 Orlan o,FL.32828 (321)251-6006 www.dbssinc.com May Electric June 03, 2014 Attention: William May REFERENCE: Uragallo Residence 40343 Air Time Ave. Zephyrhills, FL 33542 Mr. May, This letter is to address the attachment o the proposed Photovoltaic system to the roof of the structure at the above referenced location. The system will consist of a total of 73 solar modules placed in 5 rows as per the attached d wing. Each row will be supported by 2 Unirac Rails each with "S-5! ProteaBracket" supports spaced at a ma�cimum of 48". Per the Florida Building Code 2010 Edition and referenced A SE 7-10, for a 145 mile per hour (Vult) wind speed zone, the maximum design pressures on t is system varies per roof location as detailed on the provided plan. Please refer to the provid d plans for fastening requirements. All other requirements of the Unirac and solar module ins allation manual must be followed. With this letter, I certify that the above ystem will meet or exceed the requirements set forth in the Florida Building Code 2010 Edition with 2012 Supplements. I have appreciated the opportunity of providing my engineering serv ces to you on this project and attest that the information contained in this letter is accurate t the extent of my knowledge. Should you have any questions or if I can be of further assistance, please do not hesitate to contact me. �incerely, � ` �� Scott A. Santomauro, .5., P.E. Fla. Reg. 65513 . President � ' DBSS, Inc. CA#2731 li I I I i I i I