HomeMy WebLinkAbout14-15661 � �CITY OF ZE HYRHILLS ,
5335-8T STREET '
(sis)�s -0020 15�61
BUILDING PERMIT SING E FAMILY RESIDENTIAL �.°
' � b�i:d�.ii=-°--- - ----_� -- -- � �- -.,- ,.erd y�P= _ .'=�i"�.. j ----- _- — - --�A,--- - -- -:�e.t^� ��,e,Y,,R'^rz-+gzws�F_=„
"�:"�,.��PE-RMIT;�INFORMATIO.N �.. •.. ,'�:�;�.M.�... __ � , �..,,LOCATION:INFORMATIO d :.�.��:�.� _..
Permit#:15661 Issued: 9/16/2014 Address: 37757 PRAIRIE ROSE LP LOT 41
Permit Type: GENERAL BUILDING PERMIT ZEPHYRHILLS, FL.
Class of Work: 105-NEW CONST/MULTI 5+ UNIT Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
� Cost: Total Fees: 8,495.46 Subdivision: WALNUT GROVE TOWNHOMES
Amount Paid: 8,386.37 Date Paid: 9/16/2014 Parcel Number: 15-26-21-0210-00000-0410
...�.---- --- -r r- - - , - � �^e;,za�_:,�.;: _.;��:y��'.,a'�—` - --- -�t-- .i- ��r ��-
'�u�;CONTRACTOR�INF,QRMATION��..��`:��`T r��� -h a �u;f��O.1NNER:�INF�ORMI�TION� �a ��� - _
Name: BAILEY CONTRACTING LLC Name: BUTTERFIELD MOBILE HOME
Addr: 4209 GALL BLVD Address: 4034 GALL BLVD
ZEPHYRHILLS, FL 33542 ZEPHYRHILLS FL 33542-6219
Phone: (813)377-7395 Lic: Phone: 813-973-5250
Work Desc: NEW SINGLE FAMILY HOME (3) 377 .7 .
k,,.,:g;��kT,,-:;...;._,,_,_ , . f ��,:, -AP.P.LI.CA� ION FEES"���,'��._ ��`Y `" .. . .:. �:;=�r�,�:��;.,�:,.-/.__.
:��,.�...:�.__, _ .
BUILDING FEE 330.69 ELECTRICAL FEE 69.64 PLUMBING FEEf 46.43
MECHANICAL FEE 32.50 SEWER CONNECTION ESIDEN� 2,010.0 WATER CONNECTION RESIDENI 641.00
WATER METER RES 3/4" 457.18 IRE PLAN REVIEW F ES 105.11 POLICE IMPACT FEE 254.00
PUBLIC SAFETY 5% 26.35 PARK FEES TOWNHO ES 769.56 TRAFFIC IMPACT FEE 99% 3,445.20
TRAFFIC IMPACT FEE 1% 34.80 FIRE IMPACT FEE 273.00
��,(�-l�k
C�No� �.��-�' - - ^„�-�
� � "� . e�� - �-�- 3�k �� �s
_ , � �. � �a�- .
� � ��
�.'�- p=' �.,.�;r.--x �6 • _ _ r�m`�=�a�- ' .+cr,uvr�+ z:. '�,�. '.^+u:� -+ r� � "�'� f ��" k`�� -'� -
�;���.,,���;�.�s �:� - , 'Ins ecfion �Re uired ,.� K� -_ _ -�-:�`�—o.�>
FOOTER 2ND ROUGH PLUMB MIS INSULATION CEILING
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
� 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
� REINSPECTION FEES: Reinspection fees will comply ith Florida Statute 553.80 (2)(c)when extra inspection
trips are necessary due to any one of the following re sons: a) wrong address b).condemned work resulting
from faulty construction c) repairs or corrections no made when inspections called d) work not ready for
' inspection when called e) permit not posted on jo site t) plans not at job site g)work not accessible.
NOTICE: In addition to the requirements of this permit, ther may be additional restrictions applicable to this property that
may be found in the public records of this county, and ther may be additional permits required from other governmental
entities such as water manageme t, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice f commencement may result in your paying twice for
improvements to your property. If you intend to ob in financing, consult with your lender or an attorney
� before recording your otice of commencement."
Complete Plans, Specifications and Must Accompany Application. All work shall be performed in accordance
with City Codes and Ordinanc s. NO OCCUPANCY BEFORE C.O.
�
CO TRA TORS S NATURE PERMIT OFFI
PERMIT EXPIRES IN 6 MONTHS ITHOUT APPROVED INSPECTIO
CALL FOR INSPECTION - HOUR NOTICE REQUIRED
PROTECT CAR FROM WEATHER
; '
Print Form
- CITY OF ZE HYRHILLS
UTILITIES ORK ORDER
I
WATER ACCOUNT NO.: DATE: Sep 16,2014
OWNER/RENTER/BUSINESS:Butterfield mobile home Ilc CONTACT PERSON: Wayne Butterfield
MAILING ADDRESS: 4034 Gall Blvd PHONE NUMBER: 813-937-5250
EMAIL ADDRESS:
SERVICE ADDRESS: 37757 Prairie Rose Lp Lot 47
SHUT OFF SERVICE OX ❑X WATER
TURN ON SERVICE ❑ ❑ SEWER
INSTALL MEfER X❑ ❑ GARBAGE
READ MEfER ❑ ❑X IN CITY
CHECK MEfER ❑ ❑ OUT CITY
OTHER - ❑
DESCRIBE OTHER: 3/4water
NUMBER F UNITS
DEPOSIT AMOUNT
� AMOUNT LAST BILL
DATE
MISC. C ARGE
METER: FULL 3/4
IRRIGATION
WORK COMPLETED BY&DATE OR ER TAKEN BY: jackie boges
COMPLETED
OR ER GIVEN BY: C�.�,_� �,
Revised 9/2010
� �y,-�� C�� -
FORM 405-10 '
FLORIDA ENERGY EFFICIENCY CODE OR BUILDING CONSTRUCTION
Florida Department of Business and Professiona/Re ulation - Residential Performance Method
Pioject Name: Walnut Grove TH 1456 S Sui! erName:
Streetr 4408 Court Sfreet Per it�ce: Ze hyrhills /�
City,State,Zip; Zephyrhills,FL,33542- Per itNumbar. .�� �-Sp�J
Owner.� Juri dlction: 11600 '
DesignLocaHon: FL,Tampa •
9. NewconstrucSonorexisfing New{FromPlsns)� 9. a!lTypes(1123.9 sqfL) Insulation Area y
2. 3ing/efamllyormulUplefamily Multi-family e ConcreteBlock-!nflnsul,Ezferior R=4.0 825.28ft°
b Frame-Wood,AdJacent R=11 0 174.64 tt'
3. IJumberofunits,ifmultiptetamily 1 c ConaeteBlock-lntJnsul,AdJecenf R=4.0 124.00R'
4. NumberofBedrooms 3 d N�A R= ft'
5. /sthisaworstcase7 �0 10. eilingTypes (1456.0sqR.) lnsulation Area �
a Unde�Aftic(Vented) R=30.0 1456.00R
6. Conditioned Aoorerea above grade(tt�) 9456 b N/A R= !12 .
CondiBonedfloorareabelowgrade(!t�) 0 c N/A R= ft=
�1. ucts R R2
7. Windows(936.3 sq(t) DescrJpBon Area a Sup:Atfic,ReL HVAC 9,AH:HVAC 1 6 255
a. U-Factor. D61,U=0.50 136.31 ft� - �
SHGC: SNGC=0.50 • ,
b. U-Fector: N/A q� 12• olingsystems k8tu/hr Efficiency
SNGC: CeqtralUnit 25.0 SEER:13.75
c. U-Factor. N/A R' �
SHGC: 13. eating systems � k8tu/hr E�aency
d. U-Factor; N/A R' .ElectricNeatPump' 23.6 NSPF.•8.20
SHGC:
Nea Welghted Average Overhang Depth: 3.6B2 ft
AreaWeighfedAverage SNGC: 0,5Q0 • 14. otwatersysfems
8. FloorTypes (1456.0 sqft) lnsufa8on Area •Elecbic Cap:40ga1lons
EF:0.920
a.Slab-On-GradeEdgelnsulafion R=0.0 1456.00ft� . Conservatlonfeafures
b.N/A R= (1' None
c.N/A R= � 15, redits Pstat
G/ass/F1oorArea: 0.094 Tota/Proposed Mo'd�ed Loa s: 30.77 � pASS
Tota!Standard Reference Loa s: 39.79
� �i
!hereby certffy that fhe plans and speo�cations covered by Revr w of the plans and �'�ST,�,
this calculadon are in com lian 'tf)the Florida Energy spe ificafions covered by this • ti�� _���0� �
Code. • calc Jationindicatescompliance g�,a ' °�°�,�� �p
� xa- ., `';�g- � ° C'p
- with ti►s Florida Energy Code. ,., :•��
PREPARE � :� :f �� � Bef re construction is completed � q " �°
DATE: `�� ` this uilding will6e inspeCted fo� ` c� ' �
% '. , - � com liance with Section 553.908� * � ,
!hereby certi/y fhat this i�ulldingras deslgned,is!n compliance F!o a Statutes. . �, � '�S
with the Fforrda Energy Code, ' /,�G��� C�A '[��
� r
OWNER/AGENT: , � BU DING OFFIClAL: .
DATE.' DA E:
- Compllance requires certificatlon by the'rair handler unit manufac rer that the air handler enclosure qualifles as -
certified factorysealed tn accordance with 403.2.2.1.1. •
- Compllance requires compietlon of a Florida Air 8arrier and Insul tion Inspection Checkllst
5BR0141:11PM EnergyGaugeOUSA-F1aRes2010Secti n405.4.1CompliantSoftware Pagelof6
� , ,
PRO ECT
Title: Walnut Grove TH i456 S Bedrooms. 3 Address Type. Street Address
Buifding Type: User Cond'dioned Area: i456 Lot#
�I Owner. Total Stories. 1 Block/SubDivision:
I �f of UnBs: i Worst Case: No PlatBook:
Builder Name: Rotate Ang/e: 180 Street: 4408 CouR Street
Permit O/fice: Zephyrhills Cross Ventilation: County: Pasco
Jurisdiction: 6i 1600 Whole House Fan: City,State,Zip: Zephyrhills,
Family Type: Multi-(amily FL, 33542-
New/Existing: New(From Plans)
Comment:
CLI ATE
/ fECC Design Temp lnt Design Temp Neating Design Daily Temp
U Design Location TMY Site Zone 7.5% 2.5% Winter Summer Degree Days Moisture Range
FL, Tampa FL_TAMPA_INTERNATIO 2 39 9i 72 75 645.5 54 Medium
BLO KS
Number Name Area Volume
1 B/oCkl 1456 11648
SP CES
Number Name Area Volume K'�tchen Occupants Bedrooms Infil lD Finished Cooled Heated
� 1 HVAC 1 1456 ii648 Yes 4 3 1 Yes Yes Yes
FL ORS
# Floor Type Space Perimeter R-Value Area Tile Wood Carpet
1 S/ab-On-Grade Edge Insulatio HVAC 1 142 ft 0 i456 Rz -___ 0.4 0.4 0.2
R OF
/ Roof G b/e Roof So/ar SA Emitt Emitt Deck Pdch
U # Type Materials Area A ea Color Absor. Tested Tested lnsul. (deg)
1 Nip Composition shingles 1534 tt2 O ltz Dark 0.96 No 0.9 No 0 18.4
' A TIC
V # Type Ventilation Vent atio(1 in) Area RBS fRCC
1 Ful!attic Vented 00 1456 RZ N N
CEI ING
# Ceiling Type Space R- lue Area Framing Frac Truss Type
1 Under Aitic(VentedJ HVAC Y 3 i456 ft2 0.11 Wood
5/8/2014 1:1 i PM EnergyGauge�USA-FlaRes201 Section 405.4.1 Compliant Software Page 2 of 6
WA LS
Adjacenl Space Cavity Width Height Sheathing Framing Solar Below
0
^ 1 W=>E Garage Frame-Wood HVAC 1 11 3 0 8 0 24.0 ft2 0 0.23 0.01 0
� 2 N=>S Garage Frame-Waod HVAC l i i 2.83 0 8 0 22.8 ft2 0 0.23 O.Oi 0
� 3 W=>E Garage Frame-Wood HVAC i 11 6.33 0 8 0 50.6 ft2 0 0.23 O.Of 0
� 4 N=>S Exfe�ior Cancrete Block-!nt lnsu! HVAC f 4 5.33 Q 8 0 42.6 ftz 0 0 0.35 D
� 5 N=>S Exierior Goncrete Block-lnt Insu! HVAC 1 4 12.17 0 8 0 974 ft2 0 0 0.35 0
_ 6 E=>W Garage Concrete Block-!nt lnsu! HVAC 1 4 15.5 0 8 0 124.0 ftz 0 0 0.0 f 0
^ 7 W=>E Exterioi Concrete Block-Int Insuf HVAC 1 4 i3.17 0 8 0 105.4 f12 0 0 0.35 0
� 8 N=>S Garage �rame-1Nood MVAC f 77 9.67 0 & 0 77.4 ft2 Q 0.23 D.Of D
,� 9 W=>E Exterior Concrete Bfock-Int Insul HVAC 1 4 9.67 0 8 0 774 ft2 0 0 0.35 0
_1 D S=>N Exteriar Concrefe 8lock-!nt lnsul HVAG 1 4 f 6.33 0 8 Q 730.6 Rx Q 0 Q.35 D
_11 W=>E Exterior Concrete Block-Int lnsul NVAC i 4 16 0 8 0 i28.0 ft2 0 0 0.36 0
_i2 S=>N Exterior Concrete Block-tnt tnsul NVAC 7 4 i3.83 0 8 Q f 1Q.S ftz Q D 0.35 p
�13 W=>E Exteriar Concrete Block-Int Insul hIVAC 1 4 8.33 0 8 0 66.6 tt2 0 0 0.35 0
�f4 E=>W Exferior Concrefe Btock-tnt insut NVAC f 4 8.33 Q 8 Q &6.&ft2 Q 0 0.35 0
DO RS
# Ornt Doar Type Space Storms U-Value Width Height Area
Ft /n Ft ln
i W=>E Insulafed NVAC i None 0.35 3 0 6.67 0 20.Q1000
2 N=>S lnsulated MVAC 1 None 0.35 3 0 6.67 0 20.01000
WIN OWS
Orientation shown is the entered a�ientation > chan ed to As Built rotated 780 de rees.
/ Wall Overhang
V ,# Ornt ID Frame Panes NFRC U-Factor SNGG Area Depth Separation Int Shade Screening
1 N=>S 5 TfM Low-E Double Yes 0.5 0.5 i6.2 ft2 1 8 0 in i R R in Drapesfilinds Exferior 5
2 W=>E 7 TIM Low-E Double Yes 0.5 0.5 18.2 ftz i ft 0 in 1 ft 0 in Drapes/blinds Exterior 5
3 W->E 9 TlM Low-E Doubie Yes 0.5 0.5 9.8 ft2 7 ft 0 in l/t 0 in Drapeslblinds Exterior 5
4 S-sN 10 TIM Low-E Double Yes 0.5 0.5 i2.8 ftz 8 ft 0 in O 1t 0 in Drapes/blinds Exteriar 5
5 S=>N i0 TIM Low-E Double Yes 0.5 0.5 12.8 ft2 9 ft D in 0 ft 0 in Drapeslblinds Exterior 5
6 S=sN 1 d T!M Low-E Double Yes 0.5 0.5 20.0 ftz 9 ft 0 in 0/t 0 in Drapes/blinds None
7 W->E f 1 T/M Low-E Double Yes 0.5 D.5 16.7 RZ i R D in 1 8 0 in prapeslblinds Exterior 5
8 W=>E 1 i TIM Loiv-E Double Yes 0.5 Q.5 16.2 Rz i/t 0 in 1 8 0 in Drapes/blinds Exterior 5
9 S=sN i2 TiM Low-E Double Yes 0.5 0.5 l6 2 RZ i R 0 in i fr D in Drapes/blinds Exterior 5
GA AGE
# FloorArea CeilingArea Exposed a!lPerimeter Avg. WallHeight ExposedWa!llnsulation
1 288 RZ 288 k2 0 ft 8 ft 0
518120i4 J:11 PM EnergyGauge(9 USA-FlaRes2Q1 Section 405.4.f Campiiant SoftGVVare Page 3 of 6
I �
I
INFILT ATION
# Scope Method SLA CFM 50 ELA EqLA ACH ACH 50
1 Wholehouse Best Guess 0.00�300 1 i45.73 .8992 118.291 0.22500 5.90178
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducfs
pnvaliElectric Heat Pump None HSPF:8.2 23.6 kBtu/hr 1 sys#1
COOLIN SYSTEM
# System Type Subrype Efficiency Capacity Air Flow SHR Block Ducts
(lnvaliCentra/Unit None SEER:13.75 25 kBtu/hr 750 cim 0.75 7 sys#1
HOT WAT R SYSTEM
�f System Type SubType Location EF Cap Use SetPnt Conse�vation
1 Electric None Garage 0.92 40 gal 60 gal 120 deg None
SOLAR HOT W TER SYSTEM
FSEC Collector Storage
Cen # Company Name System Mod /lf Collector Model# Area Volume FEF
None None ft2
DU TS
/ ----Supply---- ----Return---- Air CFM25 HVAC#
\� # Location R-Value Area Location Area Leakage Type Handler CIF�p5 OUT QN RLF Neat Cool
(invali Aitic 6 255 ft2 NVAC 1 20 fr2 e/au/l Leakage HVAC 1 (invalid)c/(Defau/t)c 1 i
TEMPE ATURES
Programable Thermostat: Y Ceiling Fans:
Cooling Jan Feb Mar Api May (X Jun (X Jul (X Aug (X Sep Oct Nov �Dec
Heatin Jan Feb Mar A r Ma Jun Jul Au Se �Oct Nov X]Dec
Venting (jJan [}Feb JCjMar JApr M y (� Jun f Jul (� A g � S p �X]Oct €X;Nov �(]Dec
5/8/2014 1:11 PM EnergyGauge�USA-FlaRes201 Section 405.4.i Compliant Software Page 4 of 6
Thermostat Schedule: HERS 2006 Re%rence Hours
Schedule Type 1 2 3 4 5 6 7 8 9 i0 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heafing(WD) AM 66 66 66 66 66 68 68 6B 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Neating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 6B 68 68 68 68 68 68 66 66
5/8/2014 1:11 PM EnergyGauge�USA-FlaRes201 Section 405.4 1 Compliant Sofrware Page 5 of 6
i � ' •
I
i
FORM 405-10
Florida Code Compli nce Checklist �
Florida Deparfinent of Business an Professional Regulations
Residential Who/e Building P rformance Method
ADDRESS: 4408 Court Sfreet PERMIT#:
Zephyrhllls,FL, 33542-
�
MANDATORY REQUIREMENTS SUMMAR�Y-See indlviduaf co e sections for full detaits.
COMPOfdENT SECTION SUMMARYOF REQ lREMENT(S) CHECK ,
Airleakage 402.4 To be caulked,gasketed, we therstripped or ofherwise sealed.
Recessed lighting!C-rated a meeting ASTM E 283. Windows and
doors=0.30 cfm/sq.ft. Testin or visua!inspecfion required. �
Fireplaces:gasketea!doors outdoor combustion air. Must complefe
envelope/eakage report or v� ually verify Table 402.4.2.
Thermostai 8 403.1 At least one thermostat shal! e provided for each separate heating
contr�/s and cooling system. Where f rced-air furnace is.primary system, -�
programmable thermosfat is equiied.Heat pumps wifh supplemental
e/ectric heat must prevent su plemental heat when compressor can
meet the load. •
�
Ducts 403.2.2 All ducts, airhandlers, frlterb xes and building cavities which form the
primary air containment pas �geways for air distribution systems shad
be considered ducts or plen chambers, shal!be construcfed and /
sealed in accordance with S cfion 503.2.7.2 of fhis code. ��
403.3.3 Building framing ca vities sha 1 not be used as supply ducts.
Water neaters 403.4 Heat frap required for vertic pipe risers. Comply witf�efficiencies in
Table 403.4.3.2.Provide swi ch or cleariy marked circuit breaker
(e/ecfric)or shutoff(gas). Ci ulating system pipes insulafed to= �
R-2+accessible manua!O swifch.
Mechanical 403.5 Homes designed to operate t posifive pressure or with mechanical
ventilation ventilation systems sha11 not exceed fhe minimum ASHRAE 62 leve/. "
. No make-up airfrom attics,. rawlspaces,garages oroutdoors adjacent ✓ i
to pools or spas. -- ,
.
SwimmingPools 403.9 'Poo!pumps and pool pump otors with a total horsepower(HP)of=1
8�Spas - . HP shall have the capabifity f operating at two ormore speeds. Spas
;.:• •-, ' - ' and.heated pools must have vapor-retardant covers or a liquid cover or,
�, � — • other means proven fo redu e heat loss except if 70%.of heat from a.�a_
� . . site-recovered enen,�y. Off/�i er switch r+equired. Gas heaters minimum -
thermal efficiency=78%(82 o after 4/16/13). Heat pump poo!heaters '
� minimum COP=4.0.
Cooling/heafing ` 403.6 Sizing calculation performe &attached.Minimum effciencies per �
Tables 503.2.3.Equipment �ciency ve�cafion required. Specia!
equipmeni oc�asion cooling orheafing apacityrequir�s separ�te system or .
variable capacity system. E ctric heat>10kW must be divided into two .
or more sfages.
, Ceilings/knee walls 405.2.1 R-19 spaCe permitting. , ,
�
5�8/2014 i:11 PM EnergyGauge�USA-FlaRes2010 Secd n 405.4.i Cemp/Iant Software Page 6 of 6
t
�a ._ . v ---� • • ---- • .--____ __�..__ __ _ ._
ENERGY PERFOR ANCE LEVEL (EPL)
DISPLA CARD
ESTIMATED EIVERGY PE FORMANCE INDEX* = 77
The lower the EnergyPerformance Index, fhe more efficient the home.
4408 Court Street, Z phyrhills, FL, 33542-
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Sing/e family or mu/tiple famify Mu/ti-/amily a.Concrete Block-Int lnsul,Exterior R=4.0 825.28 Rz
b.Frame-Wood,Adjacent R=11.0 174.64 Rz
3. Number of units,if multiple family 1 c.Concrete Block-Int Insul,Adjacent R=4.0 i24.00 frz
4. Number of Bedrooms 3 d.N/A R= 1t2
5. /s this a worst case? No 10.Ceiling Types /nsulation Area
a.UnderAttic(Vented) R=30.0 1456.00 ft2
6. Conditioned floor area(ft2) 1456 b.N/A R= ft2
c.N/A R= ftz
7. Windows" Description Area �i,Ducts R ftz
a. U-Factor: Dbl,U=0.50 136.31 ft2 a.Sup:Attic,Ret:HVAC 1,AH:HVAC 1 6 255
SHGC: SHGC=0.50
b. U-Factor. N/A frz
SHGC: 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A ftz a.Centra/Unit 25.0 SEER:i3.75
SHGC:
d. U-Factor: N/A �2 13.Neating systems kBtu/hr Efficiency
SHGC: • a.E/ectric Heat Pump 23.6 NSPF.•8.20
Aiea Weighted Average Overhang Depth: 3.682 ft.
Area Weighted Average SHGC: 0.500
8. Floor Types /nsu/ation Area 14.Hot water systems
a.Slab-On-Grade Edge lnsulation R=0.0 1456.00 RZ a.Electric Cap:40 gallons
EF.•0.92
b.N/A R= ftz
c.N/A R= h2 b. Conservation features
None
15.Cred'ds Pstat
I certify that this home has complied with the Florida Energy Ef'ciency Code for Building �qgE SrqT
Construction through the above energy saving features which ill be installed(or exceeded) .y o - : �`60
in this home before fina!inspection. Otherwise, a new EPL Dis !ay Card wil!be completed yki",,,,��.' �:=,,��;,� �.�,
base d on ins ta l le d Co de comp lian t fea tures. � �r«< . ,,,,:::-°:€�:•,;;:,,N••;,'�o�
,�
Builder Signature: ate: � i;�;j a
t � �
Address of New Home: City/FL Zip: f�, g�
cob H,�,�o
'IVote: This is not a Building Energy Rating. lf your Inde is below 70,your home may qualify for energy efficient
mortgage(EEM)incentives if you obtain a Florida Energy auge Rating. Contact fhe EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygau e.com for information and a list of certified Raters. For
information aboui the Florida Building Code, Energy Cons rvation, contact the Florida Building Commission's
support staff.
""Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnergyGaugecA USA-F/aRes201 Section 405.4.1 Compliant Software
TABLE 402.4.2
AIR BAFiRIER AND INSULATION IN PECTION COMPONENT CRITERIA
Project Name: Wa/nut Grove TH 1456 S Builder Name:
Street: 4408 Court Street Permd Olfice: ZephyrhiNs
City,State,Zip: Zephy�hills,FL,33542- Permd Number:
Owner: Jwisdiction. 611600
Design Locatron. FL, Tampa
C06VIPONENT CRITERIA CHECK
Air barrier and thermal barrier Exterior thermal envelop insulation for framed walls is installed in
substantia!contact and ntinuous alignment with building envelope
air barrier.
Breaks or joints in the ai barrier are filled or repaired.
Air-permeable insulation 's not used as a sealing maferial.
Air- ermeable insulation 's inside of an air barrier.
Ceiling/attic Air barrier in any droppe ceiling/soffit is substantially aligned with
insulation and any gaps re sealed.
Attic access (except unv nted attic), knee wall door, or drop down
stair is sealed.
Walls Corners and headers ar insulated.
Junction of foundation a d sill plate is sealed.
Windows and doors Space between window oor jambs and framing is sealed.
Rim joists Rim joists are insulated nd include an air barrier.
' Floors (including Insulafion is installed to aintain permanent contact with underside
above-garage and of subfloor decking.
canfilevered floors)
Crawl space walls Insulafion is permanentl attached fo walls.
Exposed earth in unvent d crawl spaces is covered wifh Class I
Shafts,penetrations Duct shafts, utility penet ations, knee walls and flue shafts opening
to exterior or unconditio ed space are sealed.
Narrow cavities Batts in narrow cavifies re cuf to fit, or narrow cavities are fiNed by
sprayed/blown insuJatio .
Garage separation Air sealing is provided b fween the garage and conditioned spaces.
Recessed lighting Recessed lighf fixtures re air fight, IC rafed, and sealed to drywall.
Exception—fixtures in c nditioned space.
Plumbing and wiring Insulation is placed bet een outside and pipes. Batt insulation is cut
to fif around wiring and lumbing, or sprayed/blown insulation
Shower/tub on exterior wall Showers and tubs on e terior walls have insulation and an air
barrier se aratin them rom the exterior wall.
Electrical/phone box on Air barrier extends behi d boxes or air sealed-fype boxes are
installed.
Common wall Air barrier is installed in ommon wall between dwelling units.
; HVAC register boots HVAC register boofs th f penetrate building envelope are sealed to
subfloor or dr all.
� Fire lace Fire lace walls include n air barrier.
�
EnergyGaugeC�USA-F/aRes201 Section 405.4.1 Compliant Software
i
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
HVAC Designs Walnut Grove TH 1456 S
Tam a FL 33615 Pa e 1
Pro'ect Re ort
General Pro'ect Information
Project Title: Walnut Grove TH 1456 S
Project Date: Thursday,May O8,2014
Company Name: HVAC Designs Inc
Company Representative: Neil Fimbel
Company Address: 7701 W Hanna Ave
Company City: Tampa FL 33615
Company Phone: (813)885-2258
Company E-Mail Address: neil@hvacdesigns.com
Company Website: http:llwww.hvacdesigns.coml
Desi n Data
Reference City: Zephyrhills,FI rida
Building Orientation: Front Door fac s South
Daily Temperature Range: Medium
Latitude: 28 Degrees
Elevation: 19 ft.
Altitude Factor: 0.999
Outdoor Outdoor Outdoar Indoor Indoor Grains
Drv Bulb Wet Bulb Rel.Hum Rel.Hum Drv Bulb Difference
Winter, 40 37.52 nla nla 72 nla
Summer: 93 77 49% 55°/a 75 43
Check Fi ures
Total Building Supply CFM: 850 CFM Per Square ft.: 0.584
Square ft.of Room Area: 1,456 Square ft.Per Ton: 831
Volume(ft')of Cond.Space: 11,647
Buildin Loads
Total Heating Required Including Ventilation Air: 20,537 Btuh 0.537 MBH
Total Sensible Gain: 15,773 Btuh 80 %
Total Latent Gain: 3,917 Btuh 20 %
Total Cooling Required Including Ventilation Air: 19,690 Btuh 1.75 Tons(Based On 75%Sensible Capacity)
Notes
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J Bth Edition,Version 2,and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads accordin to the manufacturer's performance data at your design conditions.
Thursday,May 08,2014,1:03 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
HVAC Designs Wa/nut Grove TH 1456 S
Tam a FL 33615 Pa e 2
Manual D Ductsize Data- Duct S stem 1 -Su i
-Duct Name,etc.
Type Roughness Diameter Velociry SPL.Duct
Upstream Temperature Width Loss1100 SPL.Fit
Shape Length Height Fit.Eq.Len SPL.Tot
Sizin CFM Area SP.Avail SPL.Cumul
-Duct Name:SMT-100,Feeds Into:Foyer,Fitting:1-A,Effective Length 27.6
Trunk 0.003 14.2 729 0.005
Up:Fan 57 12 0.086 0.018
Rect 6.2 14 21.4 0.184
Schedule 850 26.7 0.089 0.221
-Duct Name:SR-100,Supplies:Kitchen,Fittings:l1-B,11-B,11-B,4 ,11-B,Effective Length:21.8
Runout 0.01 7 599 0.010
Up:ST-110 57 5.4 0.184 0.030
Rnd 5.3 7.7 16.5 0.040
Schedule 160 9.7 0.006 0.310
-Duct Name:SR-110,Supplies:M Bath,Fittings:11-8,11-B,11-B,4 ,Effective Length:11.7
Runout 0.01 4 229 0.004
Up:ST-110 57 3.1 0.061 0.003
Rnd 6.9 4.4 4.7 0.007
Schedule 20 7.3 0.039 0.277
-Duct Name:SR•120,Supplies:M Wic,Fittings:11-6,11-B,4AA,Effe tive Length:16.5
Runout 0.01 4 57 0.001
Up:ST-110 57 3.1 0.004 0.000
Rnd 11.6 4.4 4.9 0.001
Schedule 5 12.2 0.045 0.271
-Duct Name:SR-130,Supplies:M Bed,Fittings:11-B,11-B,4AA,Effe ive Length:22.7
Runout 0.01 6 494 0.022
Up:ST-110 57 4.7 0.156 0.014
Rnd 13.9 6.6 8.8 0.035
Schedule 97 21.8 0.010 0.306
-Duct Name:SR-140,Supplies:Great,Fittings:11-B,11-B,4AA,11-B,Effective Length:18.2
I Runaut 0.01 7 584 0.009
Up:ST-110 57 5.4 0.175 0.023
Rnd 5.1 7.7 13.1 0.032
Schedule 156 9.3 0.014 0.302
I -Duct Name:SR-150,Supplies:Great,Fittings:11-B,11-B,4AA,11-B Effective Length:26.2
Runout 0.01 7 584 0.023
', Up:ST-110 57 5.4 0.175 0.023
Rnd 13.2 7.7 13.0 0.046
, Schedule 156 24.2 0.000 0.316
, -Duct Name:SR-180,Supplies:Bed 3,Fittings:11-B,11-B,4AA,11- Effective Length:16.1
Runout 0.01 6 514 0.011
', Up:ST-120 57 4.7 0.169 0.016
Rnd 6.7 6.6 9.4 0.027
Schedule 101 10.5 0.034 0.282
-Duct Name:SR-190,Supplies:Bath 2,Fittings:l1-B,11-B,4AA,Eff ctive Length:13.0
Runout 0.01 4 138 0.002
Up:ST-120 57 3.1 0.023 0.001
Rnd 7.4 4.4 5.6 0.003
Schedule 12 7.7 0.059 0.258
i
Thursday,May 08,2014,1:03 PM
, '
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
HVAC Designs Wa/nut Grove TN 1456 S
Tam a FL 33615 Pa e 3
Manual D Ductsize Data- Duct S stem 1 -Su I cont'd
-Duct Name,etc.
Type ' Roughness Diameter Velocity SPL.Duct
Upstream Temperature Width Loss1100 SPL.Fit
Shape Length Height Fit.Eq.Len SPL.Tot
Sizin CFM Area SP.Avail SPL.Cumul ,
-Duct Name:SR-160,Supplies:Foyer,Fittings:11-B,11•B,11-B,4AA,11-B,Effective Length:13.6
Runout 0.01 4 619 0.025
Up:ST-120 57 3.1 0.429 0.033
Rnd 5.9 4.4 7.7 0.058
Schedule 54 6.2 0.003 0.313
-Duct Name:ST-110,Feeds Into:Kitchen,Fittings:11•B,11-A,Effectiv Length:69.6
Trunk 0.01 14 556 0.015
Up:SMT-100 57 10.8 0.062 0.028
Rnd 24.2 15.3 45.5 0.043
Schedule 594 88.6 0.046 0.270
-Duct Name:SR-170,Supplies:Bed 2,Fittings:l1-B,11-B,4AA,11-B Effective Length:15.5
Runout 0.01 5 653 0.026
Up:ST-120 57 3.9 0.348 0.028
Rnd 7.4 5.5 8.1 0.054
Schedule 89 9.7 0.008 0.309
-Duct Name:ST-120,Feeds Into:Kitchen,Fittings:11-9,11-B,11-A,E ective Length:39.7
Trunk 0.01 10 469 0.006
Up:SMT-100 57 7.8 0.070 0.022
Rnd 8.0 10.9 31.7 0.028
Schedule 256 20.9 0.061 0.255
Report Units:Pressure:in.wg,Duct lengths:feet,Duct sizes;inch,Airflow:CFM,Velocity:ft.lmin,Temperature:F
Notes: Static pressure available values for return ducts are at the entranc of the duct. For supply,they are at the exit The cumulative static
pressure loss value for a return trunk is with respect to the entry point of t e return runout upstream with the highest static pressure available. Total
and cumulative static pressure loss values for the supply main trunk inclu e any device pressure losses entered,and the cumulative may also
include the total static pressure loss of the return side.
Summa
Number of active trunks: 3
Number of active runouts: 10
Total runout outlet airflow: 850
hfiain trunk airflow: 850
Largest trunk diameter: 14.2 MT-100
Largest runout diameter: 7 R-100
Smallesttrunkdiameter: 10 -120
Smallest runout diameter: 4 R-110
Supply fan external static pressure: 0.316
Supply fan device pressure losses: 0.160
Supply fan static pressure available: 0.156
Runout maximum cumulative static pressure loss: 0.316 R-150
Return loss added to supply: 0.043
Total effective length of return(ft.): 77.8 R-100
Total effective length of supply(ft.): 123.4 R-150
Overall total effective length(ft.): 201.2 R-100 to SR•150
Design overall friction rate per 100 ft.: 0.078 ( vailable SP x 1001 TEL)
System duct surtace area(Scenario 1): 228.1 ot Vented Attic (Linked to duct load)
System duct surtace area(Scenario 4): 26.7 xposed in Space (Linked to duct load)
Total system duct surface area: 254.8
� Thursday,May 08,2014,1:03 PM
�—
.
.
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
HVAC Designs Walnut Giove TH 1456 S
Tam a FL 33615 Pa e 4
Manual D Ductsize Data- Duct S stem 1 - Return
—Duct Name,etc.
Type Roughness Diameter Velocity SPL.Duct
Upstream Temperature Width Loss1100 SPL.Fit
Shape Length Height Fit.Eq.Len SPL.Tot
Sizin CFM Area SP.Avail SPL.Cumul
—Duct Name:RMT•100,Feeds From:Foyer,Fitting:5-A,Effective Len th:49.0
Trunk 0.003 15.3 625 0.002
Up:Fan 75 14 0.056 0.025
Rect 3.2 14 45.9 0.027
Schedule 850 14.8 -0.016 0.043
—Duct tdame:RR-100,Returns From:Foyer,Fitting:2-D,Effective Len th:28.8
Runout 0.003 15.3 625 0.001
Up:RMT-100 75 14 0.056 0.015
Rect 1.1 14 27.7 0.016
Schedule 850 4.9 0.000 0.016
Report Units:Pressure:in.wg,Duct lengths:feet,Duct sizes:inch,Airflow CFM,Velocity:ft.lmin,Temperature:F
Notes: Static pressure available values for return ducts are at the entranc of the duct. For supply,they are at the exit. The cumulative static
pressure loss value for a return trunk is with respect to the entry point of t e return runout upstream with the highest static pressure available. Total
and cumulative static pressure loss values for the supply main trunk inclu e any device pressure losses entered,and the cumulative may also
include the total static pressure loss of the return side.
Summa
Number of active trunks: 1
Number of active runouts: 1
Total runout outlet airflow: 850
Main trunk airflow: 850
Largest trunk diameter: 15.3 MT-100
Largest runout diameter: 15.3 R-100
Smallest trunk diameter: 15.3 MT-100
Smallest runout diameter: 15.3 R-100
Runout maximum cumulative static pressure loss: 0.016 R-100
Return loss added to supply: 0.043
Total effective length of return(ft.): 77.8 R-100
System duct surface area(Scenario 4): 19.7 posed in Space (Linked to duct load)
Total system duct surtace area: 19.7
Notes
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are pertormed per ACCA Manual J 8th Edition,Version 2,an ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads accordin to the manufacturer's performance data at your design conditions.
Thursday,INay 08,2014,1:03 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
HVAC Designs . Walnut Grove TH 1456 S
Tam a,FL 336i5 Pa e 5
Manual D Ductsize-Pressure Chan es Gra h -S stem 1
Pressure Changes Through Route with Fiighest Static Pressure Loss
o.�s
o.r4
0.12 D
0.f0
0.08
3
c 0.06
ai
r'n 0.04
N
d
a
0.02
0.00
-0.02
-0.04
-0.06
—� Static P�essure Available
Total Pressure Availab/e
Notes: Return side point values are at entrance of duct,while supply side oints are at exit. V�hen a return system is present,an additional return
side point named[Fan Entrance]is drawn in the graph to show the static p essure available at the entrance of the fan. When a supply system is
present,and an additional supply side point named(Fan Exit]is drawn to s ow the static pressure available at the exit of the fan. Any device
pressure losses entered for the supply main trunk are accounted for betwe n the fan entry and exit points.
Point Name Static Pre sure Available Totai Pressure Available
A RR-100 0.000 0.024
B RMT-100 -0.016 0.008
C [Fan Entrance] -0.043 -0.019
D [Fan Exit] 0.113 0.147
E SMT-100 0.089 0.123
F ST-110 0.046 0.066
G SR-150 0.000 0.022
Thursday,May 08,2014,1:03 PM
i • '
I
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
NVAC Designs Walnut Grove TH i456 S
Tam a,FL 336i5 Pa e 6
Total Buildin Summa Loads
Component Area Sen Lat Sen Total
Descri tion Quan Loss Gain Gain Gain
OP LOW E MIN:Glazing-NFRC CODE MIN Operable 2 116.3 1,867 0 2,960 2,960
Pane Low E,ground reflectance=0.23,outdoor
insect screen with 50%coverage,light color blinds
at 45°with 100°/a coverage,u-value 0.5,SHGC 0.5
FD LOW E MIN:Glazing•NFRC CODE MIN Glass Door 2 20 320 0 278 278
Pane Low E,ground reflectance=0.23,light color
blinds at 45°with 100%coverage,u-value 0.5,
SHGC 0.5
11 N:Door-Metal-Polystyrene Core 40 434 0 343 343
12B•Osw:Part-Frame,R•11 insulation in 2 x 4 stud 154.6 450 0 300 300
cavity,no board insulation,siding finish,woad
studs
13A-4ocs:Wall-Block,board insulation only,R-4 board 669 3,062 0 1,748 1,748
insulatian,open core,siding finish
13A-4ocs:Part-Block,board insulation only,R-4 board 124 532 0 355 355
insulation,open core,siding finish
16B•30-ad:RooflCeiling•Under Attic with Insulation on 1455.9 1,491 0 2,469 2,469
Attic Floor(also use for Knee Walls and Partition
Ceilings),vented attic,no radiant barrier,R-30
insulation,dark asphalt
22A•pm:Floor-Slab on grade,No edge insulation,no 142 5,362 0 0 0
insulation below floor,any floor cover,passive,
hea d or li ht wet soil
Subtotals for structure: 13,512 0 8,453 8,453
People: 4 920 1,200 2,120
Equipment: 640 2,040 2,680
Lighting: 0 0 0
Ductwork: 2,246 310 2,047 2,357
Infiltration:Winter CFM:136,Summer CFIN:70 4,779 2,047 1,382 3,429
Ventilation:Winter CFM:0,Summer CFM:0 0 0 0 0
AED Excursion: 0 0 652 652
Total Building Load Totals: 20,537 3,917 15,773 79,690
)
Check Fi ures
Total Building Supply CFM: 850 CFM Per Square ft.: 0.584
Square ft.of Room Area: 1,456 Square ft.Per Ton: 831
Volume(ft')of Cond.Space: 11,647
Buildin Loads
Total Heating Required Including Ventilation Air: 20,537 Btuh 20.537 MBH
Total Sensible Gain: 15,773 Btuh 80 %
Total Latent Gain: 3,917 Btuh 20 %
Total Cooling Required Including Ventilation Air: 19,690 Btuh 1.75 Tons(Based On 75%Sensible Capacity)
Notes
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are pertormed per ACCA Manual J Sth Edition,Version 2,and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads accordin to the manufacturer's performance data at your design conditions.
Thursday,May 08,2014,1:03 PIN
I
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
HVAC Designs Walnut Grove TH 1456 S
Tam a FL 33615 Pa e 7
� S stem 1 Room Load Summa
Htg Min Run Run Clg Clg Min Act
Room Area Sens Htg Duct Duct Sens Lat Clg Sys
No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM
—Zone 9�
2 Foyer 58 2,356 54 4 - 993 255 50 54
3 Bed 2 197 3,775 86 5 - 1,659 403 84 89
4 Bed 3 191 3,069 70 6 - 1,872 333 95 101
5 Kitchen 242 1,594 36 7 - 2,963 641 150 160
6 Bath 2 77 89 2 4 - 230 60 12 12
7 fN Bath 130 149 3 4 - 363 80 18 20
8 Great 281 5,245 119 7,7 - 5,798 1,391 293 392
9 M Wic 44 51 1 4 • 90 0 5 5
10 M Bed 236 4 211 96 6 - 1 805 444 91 97
Duct Latent 310
S stem 1 total 1 456 20 537 467 15,773 3 917 797 850
System 1 Main Trunk Size: 12x14 in.
Velocity: 729 ft.lmin
Loss per 100 ft.: 0.086 in.wg
Duct size results above are from Manual D Ductsize.
Runout duct velocities are not printed with duct size results from Manual D uctsiae since they can vary within the room. See the Manual D Ductsize
report for duct velocities and other data.
Coolin S stem Summa
Cooling SensiblelLatent Sensible Latent Total
Tons S lit Btuh Btuh Btuh
Recommended 1.75 75%I 25°/a 15,773 5,258 21,031
Actual: 2.08 75°/a/25% 18,750 6,250 25,000
E ui ment Data
Heatinq Svstem Coolina Svstem
Type: Air Source Heat Pump Air Source Heat Pump
Model: 4A6H3024C1 4A6H3024C1
Indoor Model: GAF2AOA24S21+TDR
Brand: HERITAGE 13 HERITAGE 13
Description: Air Source Heat Pump Air Source Heat Pump
Efficiency: 8.2 HSPF ` 13.75 SEER
Comment: 0
Sound: 0 0
Capacity: 23,600 Btuh 25,000 Btuh
Sensible Capacity: nla 18,750 Btuh
Latent Capacity: nla 6,250 Btuh
AHRI Reference No.: nla 4941302
This system's equipment was selected in accordance with ACCA Manual S.
Manual S equipment sizing data: SODB:93F,SOWB:77F,WODB:40F,SIDB:75F,SIRH:55%,WIDB:72F,Sen.gain:15,773 Btuh,Lat.gain:3,917
Btuh,Sen.loss:20,537 Btuh,Entering clg.coil DB:75F,Entering cig.coil W :63.9F,Entering htg.coil DB:72F,Clg.coil TD:18F,Htg.coil TD:40F,
Req.clg.airtlow:797 CFM,Req,htg.airflow:467 CFM
Thursday,May O8,2014,1:03 PM
, '
P°�4 �� ��l��Vl'Yy FLOF�I�A
Permif No. 1 J u• cC j
Dake Permitted ��y-�
� - _/r�� .
8uikder NamelOwner IVame �� �' �L13'l.��Ctc y�j1 '�L-15.;anfrol#
Caunty Parcel Na ��- - --bZ(� -- ` ��(jyC�ubDiv; �/a/`tLL��
AddresslLocation ? ?5 G^tf�^���. �,i;�,S� �i / 7-'�
Ciassi�cationlType of Use �-S j�C:�',�,`h� �� �4l)lti�1f7�.,
TRA�lSPORTATION IMPAC FEE Rate: 5q Ft Unit: t ��1 �
Exempt � Yes [] No How Determined
Impact Fee Amount $ �3 c�:�b ' Zone No. TAZ:
� SCHOOL IMPACT FEE
Account (056) Single-F mily Detached House Amount $ �
{057} Moblle H me
(058) Other Re idential
123� Collectio F�e �
Exemp# � Yes � Na Now De#ermined
PARKS AN[3 RECREA7IQ� E�
tand Account Land Credit Land Total
i Recreation Accotan# Recreation Credit Recreafion Total
�
Zone TOTAL AMOUNT $ '7��s �
�� Exempt � Yes [� No How Determined
Ii
LIBRARY FEE
Land Accaunk Land Credit l.and Tota!
Facility Account Facillty Credit Facility Total
i Exempt � Yes ❑ No How Determined Total Amount -(�'"
RESOURCE FEE ERt}
TOTAL AMOUNT
Prepared By �� Checked By
PIO CERTIFIGATE OF GCUPANCY WILL BE ISSUED�E2 FlNAL INSPEGTION
PEFtFCii2iVflE UhITI�TFtE TO7AL AMOUNTS I.ISTED HAVE
BEEN PAID AND
RECElPT�.D FOft BY CEtdTEtAL PERMITTlNG C:OFFICE OF PASGO CUUNTY
Acknowiedgement betow does not i ply acceptance of concurrence,but simpty receipt of a capy ot this farm,ptactng
fhe building permit owner n notice of thls assessmenf and the conditians of payment for same.
DATE RECEIVED BY
RECEIPT NO. DATE BY