HomeMy WebLinkAbout14-15662 CITY OF ZE HYRHILLS
5335-8T STREET
(sis)�s -0020 15�62
BUILDING PERMIT SING E FAMILY RESIDENTIAL �
.�
— - :�a-.,,� _- r, - - �-5- —r - �,�.:�.
�'��� PERMIT�INFORMATION� � �� ��P� � �::;��.:°�� ,L�OCATION„INF�O,RIIIIi4TION� �� �,��ra��.v.��.�;,.�;
x� :±��: ��. ..t.,�
Permit#:15662 Issued: 9/16/2014 LI p Address: 37759 PRAIRIE ROSE LP LOT 42
Permit Type: GENERAL BUILDING PERMIT ZEPHYRHILLS, FL.
Class of Work: 105-NEW CONST/MULTI 5+ UNIT Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 350,000.00 Total Fees: 8,495.40 Subdivision: WALNUT GROVE TOWNHOMES
Amount Paid: 8,386.31 Date Paid: 9/16/2014 Parcel Number: 15-26-21-0210-00000-0420
_�__ .�.4_..�— __ __—._,-Y:__'_"--��ror�,-- -.`��tx����.ti:,s''"°T.�� 'T`,3•y`�.,,1,k. _a�-r. __ _- j�-_�. -'r�r--°�- '-'�'�P.;:� x,=='sk�,�',L�'.��-a!'�
.�:�.��.��a CONTR�ACT�OR�;INFORMATION.�... s_ :�-�:=�.:r< au., ..::� ....�.��O.W.',NER�INF�ORMATI.ON� �" �,�_.�,r,�,�.,�-..
Name: BAILEY CONTRACTING LLC Name: BUTTERFIELD MOBILE HOME
Addr: 4209 GALL BLVD Address: 4034 GALL BLVD
ZEPHYRHILLS, FL 33542 ZEPHYRHILLS FL 33542-6219
Phone: (813)377-7395 Lic: Phone: 813-973-5250
Work Desc: NEW CONSTRUCTION 4 TOWNHOUSE (4) 37759 SEE BP#59-61
�... :�-_._ .�. � � , � �.._ ..; >>� � :,�APPLICAT'ON�FEES;:`<:�.- � . ��: r�' t;.� :". � �� ,t.:�� t;, $;.
BUILDING FEE 330.63 ELECTRICA FEE 69.64 PLUMBING FEE 46.43
MECHANICAL FEE 32.50 SEWER CONNECTION ESIDEN" 2,010.00 WATER CONNECTION MOBILE H 641.00
WATER METER RES 3/4" 457.18 FIRE PLAN REVIEW FE S 105.11 POLICE IMPACT FEE 254.00
FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5°/a 26.35 PARK FEES TOWNHOMES 769.56
TRAFFIC IMPACT FEE 99% 3,445.20 TRAFFIC IMPACT FEE % 34.80 � � � ��
� ��.a �Z_ ��-��
���,,�c� Z -�(�`-1�
�;��„ `i ,��'� ,
..No�- � ` �
- ,�e,,� ._.. ul a�- �=fi�s, -gc�-- C�d-=- :,�.�,
�:���,� � � _ :- � . �- > ��', }
.4+.:i�r s _�.-:`f,�'`w=x-g � . ' ' ��'.� . ��rs a��-a�!�. _F4.., ' %_ ��- �<�n��i4`..-'�'_��'�e 4��ac''` _
� ��Ins ectio�s�Re�"u`ired'� �_�: _
FOOTER 2ND ROUGH�PLUMB MIS INSULATION CEILING
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTtON FEES: Reinspection fees will comply w th Florida Statute 553.80 (2)(c)when extra inspection
trips are necessary due to any one of the following re sons: a)wrong address b) condemned work resulting
from faulty construction c) repairs or corrections no made when inspections called d)work not ready for
inspection when called e) permit not posted on jo site� plans not at job site g)work not accessible.
NOTICE: In addition to the requirements of this permit, ther may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water managemen , state agencies or federal agencies.
"Warning to owner: Your failure to record a notice f commencement may result in your paying twice for
improvements to your property. If you intend to ob ain financing,consult with your lender or an attorney
before recording your n tice of commencement."
Complete Plans,Specifications and Must Accompany pplication.All work shall be pertormed in accordance
with City Codes and Ordinanc s. NO OCCUPANCY BEFORE C.O.
CO RAC ORS ATURE PERMIT OFFI
PERMIT EXPIRES IN 6 MONTHS ��'HOI�T APPROVED INSPECTIO
CALL FOR INSPEC'�ION � HOUR NOTICE REQUIRED
PROTECT CAR FROM WEATHER
,�
: �� �� �ourv�r�, F�o�i��
Permit No. ---��l�
�afe-�8rm'rxt"e
l�,��ec���
Builder Name/Owner Name , ;, ��� � ,; � Control#
County Parcel No. � s�- -�Z(Q�(j(,�( C Z� SubDiv: ��,� � ��.����.c,�
Address/Location ;3 7 7 5 r�ili��� �j� �
Classification/Type of Use ` �l�yv� �
TRANSPORTATION IMPAC FEE Rate: Sq Ft Unit: 7GZ�
Exe
mpt � Yes No How Determined
❑
I Impact Fee Amount $ j Zone No. T,qZ:
SCHOOL IMPACT FEE
Account (056) Single-F mily Detached House Amount $ _ ��-
� (057) Mobile H me
(058) Other R sidential
123) Collectio Fee
Exempt a Yes � No How Determined
PARKS AND RECREA
TIOM FEE
Land Account Land Credit Land Total
Recreation Account Recreation Credit Recreation Total
Zone TOTAL AMOUNT $ 7C`�-�.E,
� Exempt � Yes � No How Determined
LIBRARY FEE
Land Account Land Credit Land Total
Facility Account Facility Credit Facility Total
Exempt � Yes � No How Determined Total Amount ,
I RESOURCEFEE ERU
TOTALAMOUNT
Prepared By "Q� ' �, Checked By
�� MO CERTIFICATE O OCCUPANCY WILL BE ISSUED OR FINAL INSPECl'IOM
PERFORM D UN71L THE TOTAL AMOUNTS LISTED HAVE
BEEN PAID AND
� RECEIPTED FOR B A CENTRAL PERMITTING OFFICE OF PASCO COUMTY
Acknowledgement below does no imply acceptance of concurrence,but simply recelpt of a copy of this form,placing
the building permit own r on notice oi thfs assessment and thQ conditions of payment for same.
DA7E RECEIVED BY
d
RECEIPT NO �DATE BY
��.___..�.____ ,. — _ . .
� • t:'ki:i�!"i'��:r•'�I... !�'I:�'I=�:i�i:l:'�'�'t':l:h�l;:s l:?(>�'�'I::';: :I.::''.':l.cfri:l.A� "f'�:i��i!":e :i.��;:��;'?;
„ •I'°'t�if:il:;l':i I;;1:1't.l�'f�'r�, !�''I...lkr4:3:X?i��� 1�='����:ril:::�: :I. �.:lf�° I.
�� r::t:��d'�f'I�'r°i[::'1'(:?f�; ;�,: (}C}'��'f;;;�r4 � �"� � :I:f:i;:it.11::: t:14�°�_.:I:(::1::�, x:� ' „
'i��l��tf�H::.,, �vi��l'I`-!!�: k:;►.!'i"i'I:::F�i��1:1::l...Ia f�,f::��:E:7:1��'"i' �.t.}t4I:3(��,;; �':�1.�<5�.;'1..::�{):�s
r�1x�S:�l�:;: ;:�#�s%�:�t? ltil.i'r"1"{:::I��i�°:i:f:::i...:l} I...r`�i��l:� f:)l::�::•:i:iri:::;; 1f>�^�Y}f::: (�:i:'l"''f'
f.;�'i_i'1 ;; �::�3:.1...,r �:1l��' :i:i••I:I:I...i...{:;
�'�::11��::t '.:��t,��::' ��y� (::i•'iii"l:'4:: �t� (:;(�o�:;l��I
�'
C:i..ii�!"i f�4��t�:'�'�:IF�;;; �.?{;t>'1:3�,�A
.�.�:�..f i�l.., s=tiYii:i!.ai�!'�'° �,iif,�
f�it::[:"t':'l� t.:i1�11�'e.�'i' �•l�-;C=C)i..lt`�!'�' C:l:::�!'i i::l��: t���i�it:l�.Ji` 'f' C7(::::::iE::i��.:Cf����":f.(:li�!fE��'I�:F�,i:�•T• ;(;t,��•1°,::�� C>f��'f''C:f�'t
. . . . „ :. .... .... ...•.. . .., :. .,
. .. .. ..
...
2 .��.�'G �.1�.. .::��.),:}!1�.i,� .... .:� .�4J���i .$t.�t..��.:li�k4•��t� ;::�r.tl....�.tJ ��!'•::?� �::. �"�::.E�. ."?l'1
�'J;
l��;F.::+:;��:.1:'.1f�:�), 7:s�' � '�_L�i........,..._....... �
• � . ._.... _..........�1/,T ................................................. ........�........�
` .
�
�
f
F
�
C
i
f
� �
I �.
i �
E
�
4
l
� __
f �
I •
i
P �
P
E
€ '
�_--- -- -----�-----_ _--�----- ----------- �
Print Form
CITY OF ZE HYRHILLS
UTILITIES W RK ORDER
WATER ACCOUNT NO.: DATE: Sep 16,2014
OWNER/RENTER/BUSINESS:Butterfield mobile home Ilc CONTACT PERSON: Wayne Butterfield
MAILING ADDRESS: 4034 Gall Blvd PHONE NUMBER: 813-937-5250
EMAIL ADDRESS:
SERVICE ADDRESS: 37759 Prairie Rose Lp Lot 42
SHUT OFF SERVICE XD ❑X WATER
TURN ON SERVICE ❑ ❑ SEWER
INSTALL MEfER ❑X ❑ GARBAGE
READ MEfER ❑ X❑ IN CITY
CHECK MEfER ❑ ❑ OUT CITY
OTHER ❑
DESCRIBE OTHER: 3/4 water
NUMBER F UNITS
DEPOSIT MOUNT
AMOUNT LAST BILL
DATE
MISC. CH RGE
METER: FULL 3/4
IRRIGATION
WORK COMPLETED BY&DATE OR ER TAKEN BY: jackie boges
COMPLETED
OR ER GIVEN BY: -
Revised 9/2010
%S o�,��� .. _ .
FORM 405-90
�
FLORIDA ENERGY EFFICIENCY CODE OR BUILDfNC CONSTRUCTION
Florida Depa�finenf of Business and Professional Re ulafion- Residentia/Performance Method
ProJecf Name: Walnut Grove TH 1505 S` 8uil erName: �;�i �� �Q�-.
Sbeet: 4408 Court Slreet Pe it Office: 2§ph�!1 Q ,
Clry,State,Zip: Zaphyrhills,FL,33542- Pe itNumber. /J 1� �i
Owner. , Juri iction: 619600
DeslgnlocaGon, FL,Tampa �
1. New conshuct/on orexlsUng New(From P/ans)' 9. s!!rypes(1109.4 sqft) Insulatfon A►ea , S
2.SinglefemilyormulHplefemlly MWti-femlly a Concrete8/ock-lntfrtsul,Exterlor R�.O 912.08R=
b Frame-Wood.Adjacent R=91.Q 197.38 k=
3. fYumberofunits,ifmultipleJemlly 1 � �y�q �. h,
4. NumberofBedrooms 3 wA � � ,
5. Is lhis e warst case7 No 1 U• iiing Types (1505.0 sqft) Insulaflon Area.
a UnderAtkc(Venfed) , R=30.0 9505.00R'
6. CondiNoned floorarsa above grada(/t') 9505 b N/A R= fN ,
CondidonedtJooraroabefowgrade(ft� 0 � wq R= �
11, ucts R R2
7. Wlndows(153.1 sqR) Descn'pflon Area a Sup:Attic,Ret•HVAC 9,AH:HVAC 1 6 244
a. U-Factor. Dbl,U=0.50 153.08 k' �
SHGC: SHGC=0.50 ' • "
b. U-Facfor. N/A ft: 12. oolingsystems kBtu/hr E/ficiertcy
SHGC: .CenhalUnit 25_0 SEER:13.75
c. U-Factor. N/A ft= �
SHGC: 13. eatingsystems � kBtu/hr Efficlency
d. U-Factor. N/A k' .Eleclrlc Heat Pump' 23.B HSPF:6.20
SHGC:
IVeaWeightedAve�ag�OverhanqDepth: 2.717 ft.
AreaWeightedAverage SHGC: p.5pp • J4. otwatersystems
8. FloorTypes (1505.0 sqft) Insu/aHon Area •Flectric Cap:40gallons
EF:0.92d
a.Slab-On-GradeEdgeMsuleNon R=0.0 ?505.00ft' . C�nserva7on�eatures
b.N/A R= h= None ..
c.N/A R= � 15. redits Pstat
Glass/F1oorArea: 0.902 Total Proposed Mo`d�ed Loa s: 31.67 • pASS
Total Starrdard Reference Loa s: 40.88
1 heneby certify fhat the plans and specifrcedons covered by Rev� w of the plans and �4�ki�ST.q�,� "
this calculation are in com lance ' he Florrda Ene�gy spe ifications covered by this ' �y � '� 0,�, `
Code. • calc /a8onindicatescompliance ti�ryt�,`' ,�s�r�,����
Q,,,._�Q �p with the F/orida Energy Code. yy '
PREPAR D .Y..• ' ' �'�KS Bef re construction!s compfeted
DATE: �•�'"`• � fhis ullding wil!be inspecfed for ' � �"` �
� • � • "' ' _ com llance with Section 553.908" * Q
/hereby ceRify thaf this bulldTng,8s designed;!s in compliance Flo da Statutes. - , �, � �
with the Florida Enen�y Code.. � COD�yE'��
OWNER/AGENT.' BU DIIVG OFFlC! '
DATE: DA E:
- Compliance requlres certlflcation by the�afr handier unit manufac rer that the ai�handler en�losure qualifies as •-
certlffed factory-sealed in accordance with 403.2.2.1.1. �
- Compliance requSrea completlon of a Florida Air BarHer and Insul tion Inspection Checkllst
5/820944:23PM Ena►gyGauqe�USA-F1aRes2010SecU n405.4.iCom�liant5oftware Page 1 of6
� �
PRO ECT
Tit/e: Wa/nut Grove TH 1505 S Bedrooms: 3 Address Type: Sireet Address
Burlding Type: User Conditioned Area: 1505 Lot#
Owner: Tota!Stories: 1 B/ock/SubDivision:
�f of Units: i • Worst Case: No P/atBook:
Builder Name: Rotate Angle: 180 Street: 4408 Court Street
Permit OHice: ZephyrhiDs Cross Ventilation: County: Pasco
Jurisdiction: 617600 Whole House Fan: Ciry,State,Zip: Zephyrhills,
Family Type: Multi-family FL, 33542-
New/Existing: New(From Plans)
Comment:
CLI ATE
/ IECC Design Temp Int Design Temp Heating Design Daily Temp
\� Design Location TMY Site Zone 7.5% 2.5% Winter Summer Degree Days Moisture Range
FL, Tampa FL_TAMPA_1NTERNATlO 2 39 9i 72 75 645.5 54 Medium
BL CKS
Number Name Area Volume
i 8/ockl 1505 12040 ,
SP CES
Number Name Area Vo/ume Kdchen Occupants Bedrooms lnfillD Finished Coo/ed Heated
1 HVAC 1 1505 12040 Yes 4 3 1 Yes Yes Yes
FL ORS
# Ffoo�Type Space Perimeter R-Value Area Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio HVAC 1 139 R D 1505 ftz ____ 0.4 0.4 0.2
,:.
R OF
/ Roof ble Roof So/ar SA Emitt Emitt Deck Pitch
V # Type Materials Area rea Color Absor. Tested Tested Insul. (deg)
1 Hip , Composition shingles 1586/tz ftz Dark 0.96 No 0.9 No 0 18.4
A IC
V � Type Venfilation Vent atio(1 in) Area RBS IRCC
i Ful!attic Venfed 300 1505 ft2 N N
CE LING
# Ceiling Type Space R- alue Area Framing Frac Tiuss Type
1 Unde�Attic(Vented) HVAC 1 1505 ftz 0.11 Wood
' S/8/2014 1:23 PM EnergyGauge(9 USA-F/aRes20 0 Section 405.4.f Compliant Soltware • Page 2 0/6
WA LS
Adjacent Cavity Width Helght Sheathing Framing So/ar Below
Space
0
_ i W=>E Garage Frame-Wood HVAC 1 1 i 3.33 0 8 0 26.61tz 0 0.23 0.01 0
_ 2 N=>S Garage Frame-Wmd HVAC 1 i l 3.17 0 8 0 25.4 ftz 0 o.23 0.07 0
_ 3 W->E Garage Frame-Wood HVAC 1 11 8.5 0 8 0 68.0 ft2 0 0.23 0.01 0
_ 4 N=>S Exterior Concrete Block-lnt Insul HVAC 1 4 5 0 B 0 40.0 Rz 0 0 0.35 0
_ 5 N=>S Exterior Concrete B/ock-Int Insul NVAC 1 4 13 0 8 0 104.01tz D 0 0.35 D
_ 6 E=>W Exterior Concrete Block-!nt Insul HVAC i 4 i4.5 0 8 0 116.0 ft2 0 0 0.35 0
_ 7 N=>S Garage Frame-Wood HVAC 1 i 1 9.67 0 8 0 77.4 ft2 0 0.23 0.01 0
_ 8 E=>W Exterior Conciete B/ock-Int lnsul HVAC i 4 13.83 0 8 0 1 i0.6 Rz 0 0 0.35 0
_ 9 S=>N Exterior Concrete Block-Ini lnsul HVAC 1 4 15.i7 0 8 0 121.4 ft2 0 0 0.35 0
_10 F=>W Exterior Concrete Block-Int Insu! HVAC i 4 20.17 0 8 0 f6i.4 BZ 0 0 0.35 0
_11 S=>N Exterior Concrefe Block-Int Insul HVAC 1 4 75.67 0 8 0 125.4 ftz 0 0 0.35 0
_12 W=>E Exterior Concrete Block-Int Insu/ HVAC 1 4 8.17 0 8 D 65.4 ftz 0 0 0.35 0
_13 E=>W Exterior Concrete B/ock-Int lnsul HVAC 1 4 8.5 0 8 0 68.0 ffz 0 0 0.35 0
DO RS
# Ornt Door Type Space Storms U-Va/ue Width Height Area
Ff In Ft In
1 W=>E Insulated HVAC 1 None 0.35 3 0 6.67 D 20.Of000
2 N=>S Insulated HVAC 1 None 0.35 3 0 6.67 0 20.01000
WIN OWS
Orientation shown is the entered orientation > chan ed to As BuiR(rotated i80 de rees.
/ Wa/l Overhang
�� # Ornf !D Frame Panes NFRC U-Factor SNGC Area Depth Separation Int Shade Screening
1 N=>S 5 T1M Low-E Doub/e Yes 0.5 0.5 23.2 ftz 1 ft 0 in 1(t D in Drapes/blinds Exterior 5
2 E=>W 6 TlM Lotv-E Doubfe Yes 0.5 0.5 16.2 itz 1 ft 0 in 1 ft D in Drapes/blinds Exterior 5
3 E=>W 8 TlM Low-E Double Yes 0.5 0.5 16.2 ftz 1 R 0 in 1/f 0 in Drapes/blinds Exterior 5
4 S=>N 9 TIM Low-E Double Yes 0.5 0.5 12.81tz 91t 0 in O 1t 0 in D�apes/blinds Exterior 5
5 S=>N 9 TIM Lpw-E Double Yes 0.5 0.5 20.0 ft2 9 ft 0 in D ft 0 in Drapes/blinds Exterior 5
6 E=>W 10 TIM Low-E Double Yes 0.5 0.5 16.2 ftz 1 ft 0 in 1 1t 0 in Drapes/6linds Exterior 5
7 E=>W 10 TIM Low-E Double Yes 0.5 0.5 i6.2 R2 7 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5
8 S=>N 11 TIM Low-E Double Yes 0.5 0.5 16.2/fz 1/t 0 in 1 ft 0 in Drapes/6linds Exterior 5
9 S=>Af 11 TIM Low-E Doub/e Yes 0.5 0.5 16.2 fiz i lt 0 in 1 ft 0 in Drapes/blinds Exterior 5
GA AGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wal/Neight Exposed Wall lnsulafion
1 238/tz 238 ftz 48(t 8 R 0
/
� -
5/B/2014 1:23 PM EnergyGauge�USA-FlaRes20 0 Section 405.4.i Compliant Software • Page 3 of 6
INFILTRATION
�f Scope Method SLA CFM 50 ELA EqLA ACH ACH 50
i Wholehouse Best Guess 0.000300 1184.29 65.0760 122.272 0.22500 5.90178
0
HEATIN SYSTEM
7f System Type Subtype Efficiency Capaciry Block Ducts
(�nvaliElectric Heat Pump None HSPF:8.2 23.6 kBtu/hr i sys#1
COOLIN SYSTEM
# System Type Subtype Elficiency Capacity Air Flow SHR Block Ducts
(fnvaliCentra/Unit None SEER:13.75 25 kBtu/hr 750 cfm 0.75 1 sys#1
HOT WAT R SYSTEM
# System Type SubType Location EF Cap Use SeiPnt Conseivation
1 Electric None Garage 0.92 40 ga/ 60 ga/ i20 deg None
SOLAR HOT ATER SYSTEM
FSEC Collector Storage
Cert � Company Name System Mo e!�f Collecto�Mode!# Area Volume FEF
None None 1tz
D CTS
/ ----Supply---- ----Refurn---- Air CFM25 HVAC#
V # Location R-I/alue Area Locafion A�ea Leakage Type Nandler C�pS OUT QN RLF Heat Cool
�nvali Attic 6 244/tz HVAC 1 18 frz Defau/t Leakage HVAC 1 (invalid)cf(Default)c 1 1
TEMP RATURES '
Programable Thermostat: Y Ceiling Fans:
Cooling Jan Feb Mar Apr May ( Jun ( Jul (X Aug ( Sep Oct Nov �Dec
Heatin Jan Feb Mar A r Ma Jun Jul Au Se Oct Nov X]Dec
Venting (�Jan (�Feb XJ�Mar JApr May f Jun f Jul { A g �( S p ]Oct XjNov (]Dec
� 5/B/2014 i:23 PM EnergyGauge�USA-F/aRes2 i0 Section 405.4.1 Compliant Software . Page 4 of 6
�
�
i
Thermostai Schedule: HERS 2006 Raference Nours
, Schedule Type � 2 3 4 5 6 7 8 9 ip f i 12
� Coo�ing(W!J) AM 78 78 78 78 78 78 78 78 80 80 80 80
� PM SO 80 78 78 78 78 78 7$ 78 78 78 78
', Cooling jWEH) AM 78 7B 78 78 78 78 78 78 78 78 78 78
PM 78 „ 78 78 79 78 78 78 78 78 78 78 y8
Heating(WD) AM 66 66 66 66 66 68 68 6B 68 68 68 68
I PM 68 68 88 6$ B8 88 68 68 68 &8 68 S6
Heating(WEH) AM 66 66 &6 66 66 S8 68 &8 68 SS 68 &8
PM 68 68 68 8$ 68 68 6B 68 68 68 66 66
4�
� 518/20i4 7:23 PM EnergyGauge�USA-F/aRes20 0 Section 405.Q.i Compliant Software Page 5 of 6
FORM 40r10
Fiorida Code Compli nce Checklist -
Florida Deparfinenf of Business an Professiona!Regulations
Residential Whole Building P rformance Method
ADDRESS: 4408 Court Street PERMlT#:
.
Zephyrhills,FL,33542- ,
� �
MANDATORY REQUIREMENTS SUMMARY-See individual c de sections for full details.
COMPONENT SECTION SUMMARYOF RE UlREMENT(S) CHECK Y
iAirleakage ' 402.4 To be caulked,gasketed, w therstrrpped or othervvise sea/ed.
Recessed lighting!C-rated a meeting ASTM E 283. �ndows and �
doors=0.30 cfm/sq.ft. Testi g or visua!inspecfion requrred
� Fireplaces:gasketed doors outdoor combusGon air. Must complete �
envelope leakage report or 'sually verify Ta6/e 402.4.2.
� Thermostat 6 403,1 At/east one thermostat sha/ be provided for each separate heating
' controls and cooling system. Where rced-air fumace is.primary system, -�
programmable thermostat is required.Heaf pumps wifh supp/emental
electric heat must prevent s pplemenfa/heat when compressor can
meet the/oad •
Ducts 403.2.2 A!!ducts, air handlers, �lter oxes and building cavities which form the �
i primary air containment pas ageways for air distribution systems shall
be considered ducts or plen m chambers,shal!be construcfed and ✓
sealed in accordance with ction 503.2.7.2 of fhis code.
.
I�i 403.3.3 Building framing caviti s sh !1 not be used as supp/y ducts.
II Water heate�s 403.4 Heat trap requir�d for vertic 1 plpe risers. Comply with e�ciencies in
jTab/e 403.4.3.2.Provide s 'tch or clearly marked circuit breaker
;� (e%ctric)or shutoff(gas). C ulating sysfem pipes insuleted Eo= �
'` R-2+accessible rnanual O F switch. ' •
.
Mechanica! 403.5 Homes designed to operet at posifive pressure or with mechanical �
ventilation ventilafion systems shall no exceed the minimum ASflRAE 621evel. "
. No make-up alrfrom attics, rawlspaces,gar� es oroutdoors ad'acent .✓ ,
9 1
. to pools or spas. _ ,
SbvimmingPools 403.9 'Paol pumps and pool pum mofors with a fota!horsepower(HP)of= 1
�Spas _ � . HR shal!have the capabili of operafing at iwo or more speeds. Spas
., . , ' .,and heated poo/s must hav vapor-refardant covers or a liquid cover or,
II�
~� � � - • other means proven to red ce hest/oss excepf if 70%a of heat from
, sife-recovered energy. Off 'mer switch required. Gas heaters minimum �y.iA
therma!efflciency=78%(8 %after 4/96/93). Heat pump poo!heaters , '
� minimum COP=4.0. - '
, Cooling/heaGng ' 403.6 Slzing calcufation perfomte &attached.Minimum e�ciencies pei '
'Tables 503.2.3.Equipmen e�ciency ver�cation required. Specia! �
', equipment oo�asion cooling or heatin capacity requires separate system or .,
'�i vaNable capacity system. lectric heat>10kW must be divided into two
or more stages.
Cellings/kneewalls 405.2.4 R-19 space pe►mitting. , ,
-
.
5/820141:23 PM EnerpyGaugeO USA-FfaRes20i 0 Sec'ort 405.4.1 Corirplient Softwere Page 6 of 6
• � .
i
ENERCY PERFOR ANCE LEVEL (EPL)
DISPLA CARD
ESTIMATED ENERGY PE FORMANCE /NDEX'�= 77
The lower fhe EnergyPerformance ndex, fhe more efficient fhe home.
4408 Court Streef, Z phyrhills, FL, 33542-
1. New construction or existing New(From P/ans) 9. Wall Types /nsulation Area
2. Single family or multiple family Multi-family a.Concrete B/ock-lnt Insul,Exterior R=4.0 9i2.08 ft2
b.Frame-Wood,Adjacent R=11.0 i97.36 fi2
3. Number ol units,il multiple family 1 c.N/A R= ftz
4. Number of Bedrooms 3 d.N/A R= ftz
5. !s this a worst case?� No 10.Ceiling Types Insulation Area
i a.UnderAttic(Vented) R=30.0 i505.001tz
6. Cond'dioned f/oor area((tz) 1505 b.N/A R= ft2
7. Windows" Description Area c.N/A R= ft2
a. U-Factor: Dbl,U=0.50 i53.08 ffz »•Ducfs R R2
a.Sup:Attic,Ret:HVAC 1,AH:HVAC 1 6 244
SHGC: � SHGC=0.50
b. U-Factor. N/A ft2
SHGC: 72.Cooling systems kBtu/hr E�ciency
c. U-Factor: N/A liz a.Central Unit 25.0 SEER:13.75
SHGC:
d. U-Factor: N/A �� 13.Heating systems kBtu/hr Efnciency
SHGC: a.Electiic Heat Pump 23.6 HSPF:8.20
Area Weighted Average Overhang Depth: 2.717 /t.
Area Weighted Average SHGC: 0.500
8. Floor Types Insulation Area 14.Hot water systems
z a.Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1505.00 R EF:0.92
b.N/A R= ftz
c.N/A R= hZ b. Conservation features
None
15.Credits Pstat
1 certify fhat this home has complied wifh fhe Florida Energy E ciency Code for Building �qKE STqT
Construction fhrough the above energy saving features which ill be installed(or exceeded) .y� ,_ � �o
in this home before final inspection. Otherwise, a new EPL Dis lay Card will be completed y��,,,�''�� _=�,,. �+
based on instaUed Code compliant features. � �1�,��'�-.': ``'; ��
Builder Signature: D te: � ����i a
* �
Address of New Home: City/FL Zip: �,coD �vg'�
vvE
"Note: This is not a Building Energy Rafing. If your Inde is below 70, your home may qualify for energy efficient
mortgage(EEM)incentives if you�obfain a Florida Energy auge Rating. Contact the EnergyGauge Hotline af(32i)
638-1492 or see the EnergyGauge web site at energygau e.com for information and a list of certified Raters. For
information abouf the F/orida Building Code, Energy Cons rvafion, contact the Florida Building Commission's
support staff.
""Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnergyGauge�USA-FlaRes201 Section 405.4.1 Compfiant Software
.
� � 2.4.2
;: TABLE 0
AIR BARRIER AND INSULATION IN PECTION COMPONENT CRITERIA
�
Pro'ect Name: Walnut Grove TH 1505 S Builder Name:
1
Streef: 4408 CouR Street Permd OHice: Zephyrhills
City,State,Zip: Zephyrhi!!s,FL,33542- Permit Number.
Owner: Jurisdiction: 611600
Design Location: FL,Tampa
i
COMPONENT CRITERIA CHECK
Air barrier and fhermal barrier Exterior thermal envelop insulation for framed walls is installed in
substantial contact and c ntinuous alignment with building envelope
air barrier.
Breaks or joints in the air barrier are filled or repaired.
Air-permeable insulation s not used as a sealing maferial.
Air- ermeable insulafion s inside of an air barrier.
Ceiling/attic Air barrier in any droppe ceiling/soffit is subsfanfially aligned with
insulation and any gaps re sea/ed. �
Atfic access(except unv nfed attic), knee wall door, or drop down
stair is sealed.
Walls Corners and headers ar insulated.
Junction of foundafion a d sill plafe is sealed.
Windows and doors Space between window oor jambs and framing is sealed.
Rim joists Rim joisfs are insulafed nd include an air barrier.
F/oors (including Insulation is installed fo aintain permanent contact with underside
above-garage and of subfloor decking.
caniilevered f/oors)
Craw/space walls ' Insu/ation is permaneni/ attached to walls.
Exposed earth in unven d craw!spaces is covered with C/ass I
Shafts,penefrafions Duct shafts, utility penet ations, knee walls and flue shafts opening
to exterior or unconditio ed s ace are sea/ed.
Narrow cavifies Batfs in narrow cavifies re cuf to fit, or narrow cavities are filled by
sprayed/b/own insu/atio .
Garage separation Air sealing is provided b tween the garage and conditioned spaces.
Recessed lighting Recessed light fixtures re air fight, IC rated, and sea/ed to drywall.
Excepfion—fixfures in c nditioned s ace.
P/umbing and wiring /nsulation is p/aced bet een outside and pipes. Batt insulation is cuf
to fit around wiring and lumbing, or sprayed/b/own insulafion
ShoweNtub on exterior wall Showers and tubs on e erior walls have insulation and an air
barrier se aratin fhem from fhe exrerior wall.
E/ectrical/phone box on Air barrier extends behi d boxes or air sea/ed-type boxes are
insfalled.
Common wall Air barrier is installed in common wall between dwelling units. �
HVAC register boots HVAC register boots th t peneirate building envelope are sealed to
- subfloor or d all.
Fire /ace Fire /ace walls include n air barrier.
EnergyGauge�USA-F/aRes20 0 Section 405.4.1 Compliani Software
Rhvac-Resldential&Llght Commercial IiVAC Loads Elite Software Development,Inc.
HVAC Designs Walnut Grove TH 7505 S
Tam a FL 336i5 ' Pa e 7
Pro'ect Re ort
General Pro ect Information
Project Title: Walnut Grove TH 1505 S
Project Date: Saturday,November 02,2013
Company Name: HVAC Designs Inc
Company Representative: Neil Fimbel
Company Address: 7701 W Hanna Ave
Company City: Tampa FL 33615
Company Phone: (813)885-2258
Company E-Mail Address: neil@hvacdesigns.com
Company Website: http:lhruww.hvacdesigns.coml
Desf n Data
Reference City: Zephyrhills,FI rida
Building Orientation: Front Door fac s South
Daily Temperature Range: Medium
Latitude: 28 Degrees
Elevatlon: 19 ft.
Altitude Factor: 0.999
Outdoor Outdoor Outdoor Indoor Indoor Grains
Drv Bulb Wet Bulb Rel.Hum Rel.Hum Drv Bulb Difference
Winter: 40 37.52 nla n/a 72 nla
Summer: 93 7T 49% 55% 75 43
Check Fi ures
Total Building Supply CFNi: 850 CFfifi Per Square ft.: 0.565
Square ft.of Room Area: 1,505 Square ft.Per Ton: 818
Volume(ft')of Cond.Space: 12,042
Buildin Load�
Total Heating Required Including Ventilation Air: 19,895 Btuh 19.895 MBH
Total Sensible Gain: 16,566 Btuh 82 %
Total Latent Gain: � 3,685 Btuh 18 %
Total Cooling Required Includ(ng Ventilation Air: 20,251 Btuh 1.84 Tons(Based On 75%Sensible Capacity)
Notes
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are pertormed per ACCA Manual J 8th Edition,Version 2,an ACCA Manual D.
All computed results are estimates as building use and weather may vary
Be sure to select a unit that meets both sensible and latent loads accordi to the manufacturer's pertormance data at your design conditions.
Thursday,May 08,2014,1:18 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
HVAC Designs Walnut Grove TH 7505 S
Tam a FL 336i5 ' Pa e 2
Manual D Ductsize Data-Duct S stem 1 -Su I
-Duct Name,etc.
Type , Roughness Diameter Velocity SPL.Duct
Upstream Temperature Width Loss/100 SPL.Fit
Shape Length Height FitEq.Len SPL.Tot
Sizin CFM Area SP.Avail SPL.Cumul
-Duct Name:SMT-100,Feeds Into:Foyer,Fitting:l-A,Effective Length:27.4
Trunk 0.003 14.2 729 0.005
Up:Fan 57 12 0.086 0.018
Rect 6.0 14 21.4 0.184
Schedule 851 26 0.098 0.227
-Duct Name:SR-100,Supplies:M Bath,Fittings:11-B,11-B,4AA,11- ,Effective Length:18.2
Runout 0.01 4 206 0.006
Up:ST-110 57 3.1 0.050 0.003
Rnd 12.1 4.4 6.2 0.009
Schedule 1� 12.6 0.043 0.281
-Duct Name:SR-110,Supplies:M Bed,Fittings:11-B,11-B,4AA,11- ,Effective Length:23.4
Runout 0.01 6 555 0.025
Up:ST-110 57 4.7 0.196 0.021
Rnd 12.9 6.6 10.5 0.046
Schedule 109 20.3 0.006 0.318
-Duct Name:SR-120,Supplies:M Wic,Fittings:11-B,11-B,4AA,11- ,Effective Length:14.3
Runout 0.01 4 46 0.000
Up:ST-110 57 3.1 0.003 0.000
Rnd 9.2 4.4 5.1 0.000
Schedule 4 9.7 0.052 0.273
-Duct Name:SR-130,Supplies:Great 1 Dining,Fittings:11-8,11-B,4 ,Effective Length:25.5
Runout 0.01 7 580 0.023
r.
Up:ST•110 57 5.4 0.173 0.022
Rnd 13.0 7.7 12.5 0.044
Schedule 155 23.9 0.008 0.316
-Duct Name:SR-140,Supplies:Great 1 Dining,Fittings:ll-6,11-B,4 Effective Length:16.1
Runout 0.01 7 580 0.007
Up:ST-110 57 5.4 0.173 0.021
Rnd 4.2 7.7 11.9 0.028
Schedule 155 7.6 0.024 0.300
-Duct Name:SR•150,Supplles:Bath 2,Fittings:11•B,11-B,4-AA,11- ,Effective Length:14.0
Runout 0.01 4 298 0.007
Up:ST-120 57 3.1 0.102 0.007
Rnd 7.1 4.4 6.9 0.014
Schedule 26 7.4 0.051 0.273
-Duct Name:SR-160,Supplies:Kitchen,Fittings:11•B,11-B,4AA,1 -B,Effective Length:23.3
Runout 0.01 6 616 0.027
Up:ST•120 57 4.7 0.241 0.030
Rnd 11.1 6.6 12.3 0.056
� Schedule 121 17.4 0.009 0.315
-Dud Name:SR-170,Supplies:Foyer,Fittings:11•6,11-6,11-B,4 ,11-B,Effective Length:13.7
Runou4 0.01 4 653 0.025
Up:ST-120 57 3.1 0.477 0.040
- Rnd 5.2 4.4 8.4 0.065
'I Schedule 57 �.5 0.000 0.324
.
Thursday,May 08,2014,1:18 PM
�I
I
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
HVAC Designs Walnut Grove TH 1505 S
Tam a FL 33675 ' Pa e 3
Manual D Ductsize Data-Duct S stem 1 -Su I cont'd
-Duct Name,etc.
Type . Roughness Diameter Velocity SPL.Duct
Upstream Temperature Width Loss/100 SPL.Fit
Shape Length Height Fit.Eq.Len SPL.Tot
Sizin CFM Area SP.Avail SPL.Cumul
-Duct Name:SR-180,Supplles:Bed 2,Fittings:11•6,11-B,4AA,Effe ive Length:19.1
Runout 0.01 6 632 0.023
Up:ST-120 57 4.7 0.253 0.026
Rnd 8.9 6.6 10.1 0.048
Schedule 124 14 0.017 0.307
-Duct Name:SR-190,Supplies:Bed 3,Flttings:11-B,11-B,4AA,11-B Effective Length:18.8
Runout 0.01 5 601 0.030
Up:ST-120 57 3.9 0.296 0.026
Rnd 10.0 5.5 8.9 0.056
Schedule �2 13.1 0.009 0.315
-Duct Name:ST-110,Feeds Into:Great!Dining,Fittings:11-B,11-B, 1•A,Effective Length:58.4
Trunk 0.01 12 562 0.017
Up:SMT-100 57 9.3 0.078 0.029
Rnd 21.1 13.1 37.2 0.046
S�chedule 441 66.4 0.052 0.272
-Duct Name:ST-120,Feeds Into:Kitchen,Fittings:71-6,11-A,Effecti e Length:47.7
Trunk 0.01 12 522 0.005
Up:SMT-100 57 9.3 0.068 0.027
Rnd 7.3 13.1 40.4 0.032
Schedule 410 22.8 0.065 0.259
Report Units:Pressure:in.wg,Duct lengths:feet,Duct sizes:inch,Airflo :CFM,Velocity:ft./min,Temperature:F
r
Notes: StaUc pressure available values for return ducts are at the entran of the duct. For supply,they are at the exit. The cumulative static
pressure loss value for a return trunk is with respect to the entry point of he return runout upstream with the highest static pressure available. Total
and cumulative static pressure loss values for the supply main trunk incl de any device pressure losses entered,and the cumulative may aiso
include the total static pressure loss of the return side.
Summa
Number of active trunks: 3
Number of active runouts: 10
Total runout outlet airtlow: 851
Main trunk airtlow: 851
Largest trunk diameter: 14.2 MT-100
Largest runout diameter: 7 R-130
Smallesttrunkdiameter: 12 T-110
Smallest runout diameter: 4 R-100
Supply fan external static pressure: 0.324
Supply fan device pressure losses: 0.160
Supply fan static pressure available: 0.164
Runout maximum cumulative static pressure loss: 0.324 R-170
Return loss added to supply: 0.043
Total effective length of return(ft.): 77.6 �- R-100
Total effective length of supply(ft.): 88.8 R-170 .
Overall total effective length(ft.): 166.4 RR-100 to SR-170
. Design overall friction rate per 100 ft.: 0.099 (Available SP x 100/TEL)
System duct surface area(Scenario 1): , 220.7 Hot Vented A�tic (Linked to duct load)
System duct surface area(Scenario 4): • 26 Exposed in Space (Linked to duct load)
Total system duct surface area: . 246.7
Thursday,May 08,2014,1:18 PM
Rhvac-Residentfal&Light Commercial FIVAC Loads Elite Software Development,lnc.
NVAC Designs Walnuf Grove TN 1505 S
Tam a FL 336i5 ' Pa e 4
Manual D Ductsize Data-Duct S stem 1 -Return
—Duct Name,etc.
Type • Roughness Diameter Velocity SPL.Duct
Upstream Temperature Width Loss1100 SPL.Fit
Shape Length Height Fit.Eq.Len SPL.Tot
Sizin CFM Area SP.Avail SPL.Cumul
—Duct Name:RMT-100,Feeds From:Foyer,Fitting:5-B,Effective Len th:48.9
Trunk 0.003 15.3 625 0.002
Up:Fan 75 14 0.056 0.025
Rect 3.0 14 45.9 0.027
Schedule 850 14 -0.016 0.043
� —Duct Name:RR-100,Returns From:Foyer,Fitting:2-D,Effective Len th:28.7
Runout 0.003 15.3 625 0.001
Up:RMT-100 75 14 0.056 0.015
Rect 1.0 14 27.7 0.016
Schedule 850 4.7 0.000 0.016
Report Units:Pressure:in.wg,Duct lengths:feet,Duct sizes:inch,Airflow CFM,Velocity:ft.lmin,Temperature:F
Notes: Static pressure available values for return ducts are at the entranc of the duct. For supply,they are at the exit. The cumulative static
� pressure loss value for a return trunk is with respect to the entry point of e return runout upstream with the highest static pressure available. Total
and cumulative static pressure loss values for the supply main trunk incl de any device pressure losses entered,and the cumulative may also
include the total static pressure loss of the return side.
Summa
Number of active trunks: 1
Number of active runouts: 1
Total runout outlet airtlow: 850
Main trunk airtlow: 850
Largest trunk diameter: • 15.3 T-100
Largest runout diameter: 15.3 R-100
Smallest trunk diameter: 15.3 MT-100
Smallest runout diatneter: 15.3 R-100
Runout maximum cumulative static pressure loss: 0.016 R-100
Return loss added to supply: 0.043
Total effective length of return(ft.): 77.6 R-100
System duct surface area(Scenario 4): 18.7 posed in Space (Linked to duct load)
Total system duct surface a�ea: 18.7
Notes
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are pertormed per ACCA Manual J 8th Edition,Version 2,an ACCA Manual D.
All computed results are estlmates as building use and weather may va .
Be sure to select a unit that meets both sensible and latent loads accordi g to the manufacturer's performance data at your design conditions.
Thursday,May 08,_2014,1:18 PM
�
�
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
NVAC Designs Walnut Grove TN 1505 S
Tam a FL 33615 � Pa e 5
Manual D Ductsize-Pressure Chan es Gra h -S stem 1
Pressure Chyanges Through Rout with Highest Static Pressure Loss
o.rs
O.i4
0.>2
o.ro
0.08
�
� o.os
d
ai 0.04
N
d
a`
0.02
0.00
-0.02
-0.04
-0.06
t Static Pressure Availab/e
Total Pressu�Available
Notes: Return side point values are at entrance of duct,while supply sid points are at exi� When a return system is present,an additional return
side point named[Fan Entrance]is drawn in the graph to show the static ressure available at the entrance of the fan. When a supply system is
present,and an additional supply side point named[Fan Exit]is drawn to show the static pressure available at the exit of the fan. Any device
pressure losses entered for the supply main trunk are accounted for be een the fan entry and exit points.
Point Name Static P essure Available Total Pressure Available
A RR-100 0.000 0.024
B RMT-100 -0.016 0.008
C [Fan Entrancej •0.043 -0.019
D [Fan Exit] 0.121 0.155
E SMT-100 0.098 0.132
F ST-120 0.065 0.083
G SR-170 0.000 0.027
�
Thursday,May 08,2014,1:18 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
HVAC Designs . Walnut Grove TH 1505 S
Tam a FL 33615 Pa e 6
Total Buildin Summa Loads
Component Area Sen Lat Sen Total
Descri tion , Quan Loss Gain Gain Gain
OP LOW E MIN:Glazing-NFRC CODE MIN Operable 2 133.1 2,130 0 3,336 3,336
Pane Low E,ground reflectance=0.23,outdoor
insect screen with 50%coverage,light color blinds
at 45°with 100%coverage,u•value 0.5,SHGC 0.5
FD LOW E MIN:Glazing•NFRC CODE MIN Glass Door 2 20 320 0 278 278
Pane Low E,ground reflectance=0.23,light color ,
biinds at 45°with 100°/a coverage,u•value 0.5,
SHGC 0.5
11 N:Door-Metal-Polystyrene Core 40 434 0 343 343
12B-Osw:Part•Frame,R-11 insulation in 2 x 4 stud 177.4 517 0 344 344
cavity,no board insulation,siding finish,wood
studs
13A-4ocs:Wall-Block,board insulation only,R-4 board 739 3,381 0 1,933 1,933
insulation,open core,siding finish
168-30-ad:Roof/Ceiling-Under Attic with Insulation on 1505.2 1,541 0 2,555 2,555
Attic Floor(also use for Knee Walls and Partltion
Ceilings),vented attic,no radiant barrier,R•30
insulation,dark asphalt
22A-pm:Floor-S1ab on grade,No edge insulation,no 139 5,249 0 0 0
insulation below floor,any floor cover,passive,
hea d or li ht wet soil
Subtotals for structure: 13,572 0 8,789 8,789
People: 4 920 1,200 2,120
Equipment: 640 2,040 2,680
Lighting: 0 0 0
Ductwork: 2,159 303 1,986 2,289
Infiltration:Winter CFM:118,Summer CFM:62 4,164 1,822 1,232 3,054
Ventllation:Winter CFM:0,Summer CFM:0 0 0 0 0
AED Excursion: 0 0 1 319 1 319
Total Building Load Totals: f• 19,895 3,685 16,566 20,251
Check Fi ures
Total Building Supply CFM: 850 CFM Per Square ft.: 0.565
Square ft.of Room Area: 1,505 Square ft.Per Ton: 818
Volume(ft')of Cond.Space: 12,042
Buildin Loads
Total Heating Required Including Ventilation Air: 19,895 Btuh 19.895 MBH
Total Sensible Gain: 16,566 Btuh 82 %
Total Latent Gain: 3,685 Btuh 18 %
Total Cooling Required Including Ventilation Air: 20,251 8tuh 1.84 Tons(Based On 75%Sensible Capacity) '
Notes
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculatfons are performed per ACCA Manual J 8th Edition,Version 2,and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads accordin to the manufacturer's performance data at your design conditions.
Thursday,May 08,2014,1:18 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
HVAC Designs : Walnut Grove TH 1505 S
Tam a FL 33615 Pa e 7
S stem 1 Room Load Summa
Htg Min Run Run Clg Clg Min Act
Room A�a Sens Htg Duct Duct Sens Lat Cig Sys
No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM
—Zone 1—
2 Foyer 71 2,518 57 4 - 1,108 263 56 57
3 Bed 2 180 3,953 90 6 - 2,414 361 122 124
4 Bath 2 60 1,071 24 4 • 498 187 25 26
5 Kitchen 283 325 7 6 - 2,349 500 119 121
6 Bed 3 171 2,030 46 5 - 1,599 182 81 82
7 Great!Dining 335 5,344 122 7,7 - 6,035 1,384 305 310
8 M Bed 248 4,472 102 6 - 2,129 425 108 109
9 M Wic 39 45 1 4 - 84 0 4 4
10 M Bath 118 136 3 4 • 351 80 18 18
Duct Latent 303
S stem 1 total 1 505 19 895 452 16 566 3,685 837 850
System 1 Main TrunK Size: 12x14 in.
Velocity: 729 ft.lmin
Loss per 100 ft.: 0.086 in.wg
Duct size resuits above are from Manual D Ductsize.
Runout duct velocities are not printed with duct size results from Manual D Ductsize since they can vary within the room. See the Manual D Ductsize
report for duct velocities and other data.
Coolin S stem Summa
Cooling SensiblelLatent Sensible Latent Total
Tons S lit Btuh Btuh Btuh `
Recommended 1.84 75%125% 16,566 5,522 22,088
ACtual: 2.08 75%!25% 18,750 6,250 25,000
E ui ment Data
f, Heatina Svstem Coolina Svstem
Type: Air Source Heat Pump Air Source Heat Pump
Model: 4A6H3024C1 4A6H3024C1
Indoor Model: GAF2AOA24S21+TDR
Brand: HERITAGE 13 HERITAGE 13
Description: Air Source Heat Pump Air Source Heat Pump
Efficiency: 8.2 HSPF 13.75 SEER
Comment: 0
Sound: 0 0
Capacity: 23,600 Btuh 25,000 Btuh
I, Sensible Capacity: nla 18,750 Btuh
Latent Capacity: n!a 6,250 Btuh
AHRI Reference No.: nla 4941302
This system's equipment was selected in accordance with ACCA Manual S
' Manual S equipment sizing data: SODB:93F,SOWB:77F,WODB:40F,SI B:75F,SIRH:55%,WIDB:72F,Sen.gain:16,566�Btuh,Lat.gain:3,685
Btuh,Sen,loss:19,895 Btuh,Entering cig.coil DB;75F,Entering cig.coil B;63.9F,Entering htg.coil DB:72F,Clg.coil TD:18F,Htg,coil TD:40F,
Req.clg.airflow:837 CFM,Req.htg,airtlow:452 CFM
,
.
Thursday,May 08,2014,1:18 PM