HomeMy WebLinkAbout14-15846 i CI OF ZEPHYRHILLS 5335-8TH SfREET (si3)�so-oozo 1 5 6 ' - FIRE A RM SYSTEM PERMIT - PERMIT INFORMATION LOCATION INFORMATION Permit Number: 15846 Address: 7346 7348 GALL BLVD I Pe,'rmit Type: FIRE ALARM SYSTEM ZEPHYRHILLS, FL. Clas�s of Work: FIRE ALARM SYSTEM Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 35-25-21-0010-08800-0000 Improv. Cost: 9,400.00 OWNER INFORMATION Date Issued: 12/24/2014 Name: TOWNVIEW RETAIL LLC/CO STOLTZ Total Fees: 200.00 Address: 725 CONSHOHOCKEN STATE RD Amount Paid: 200.00 BALA CYNWYD PA 19004-2102 Date Paid: 12/24/2014 Phone: 610-667-5800 Work Desc: INSTALLATION FIRE ALAR SYSTEM ROSS CONTRACTOR S APPLICATION FEES PECIALTY ELECTRONIC S TEM .I FIRE A RM 50.00 FIRE INSPECT ON FEES 50.00 FIRE PLAN REVI W FEES 100.00 � � � I Ins ections Re uired FIRE A CEPTANCE Final FIRE ELEVATOR RECALL , Chapter 633, Florida Statutes,authorizes th City to charge and collect user fees to pay for the costs of fire prevention and protection related activities uch as inspections, plan review,administrative fees,and other costs rel ted to the aforementioned. Complete Plans, Specifications and Fee Must Acco pany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required p rmits or opening up for commercial activity without an approved final inspection shall be charged double permit fee pe day of operation or a minimum of$100.00, whichever is greater. All work shall be performed m accordance with City Codes and Ordinances. "WARNING TO OWNER: Y UR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY ESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOU NOTICE OF COMMENCEMENT." ` ��� �� - / ,� • •�� 1 `'\� '�'J^\t� �Y'�/���i�; J't o� � � t.I.�' �^^-� �/,� r- CONTRACTOR SIGNATURE PERMIT OFFICER'-'" PERMIT EXPIRES IN 6 ONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPE ON - 8 HOURS NOTICE REQUIRED ZEPHYRHILLS IRE RESCUE DEPT- 813-780-0041 813-780-0020 City of Zephyrhills Fire Fax-813-780-0021 Permit Application Date Received Phone Contact for Permit '�Ye's"�.::":,�iC.:'-f'�.i:'�a.:.....�w�.�,........_.,�.... :a.....,� s.,--�+A+?':'L:.'.'i.".`.+'w�'1:'fr.?s..rii7>. «.m�._.....,.�..:.�::.3�!-.'i::1.:�'-..:z:%�.'7t..`.,'2'1L:w��:4..�'.°.':i;�^::3�"h�::�..a.,.r..r.y:.++-..�,..-a.-..-.�.-,... Ri1=w.-...+,�.�.,....c..-+.i Owners Name Owner's Phone Number � � � IOwner's Address Fee Simple�Titleholder Name Titleholder Phone Number � � � Fee Simple Titleholder Address � .__._.,.,.-..»y..,., - T-,z.._-...�._�r--._..�...,-.W... .�..;.,_..�.�.. -^*�-�...�,��.��-:'�.�:.._a.z�.–. _ __,_.- ._....�.s;*_^;:._��,�:,_._. - `3;-��._�°-..,�:�~:° �4�;.:�-...�. .�.�. �__._�~^-~ �.�..,--_._.,��� Job Address' ��� c✓� , � 'Lot# � Sub Division Parcel# k��.���'��,.i'S-�=y--:.:'C��-_=-�.c...�°''�`e.'-,-'.�>.'..'".-`.-.^��„��"'"'�'�_.�-,..^._--."..-"�'.:.-'P"-.'.:.':^....c+,.-�_.,.nr�. .:.°:��....�".-7�:':,'.^,�.`.s.-..:yu.-�.-.Y� r...s+::.6:��,..:�..,�.,:���'r......y....-�.-a-'-':..,'?��...xw�.�._:*�'"..,°":.'::S'�.`.wi�.a".,��.°L�':..t_�=� � Bio-Hazard Waste Storage-ANNUAL � Fumigation Tent � Comm Exhaust Kitchen Hood/Duct � Hazardous Material(Tier II or RQ Facility)ANNUAL � Controlled Bum � Hood Installation ' � Emergency Generator<30 kw � LP/Natural Gas-Installation � Emergency Generator>30 kw � LP/Natural Gas-ANNUAL Sale _ � Fire Protection Maintenance-ANNUAL � Places of Assembly-ANNUAL �y emi n t er Sprinkler � ❑ ❑ ❑ � Recreational Burn � Fire Alartn � ❑ ❑ ❑ � � Sparklers Hood Cleaning � ❑ ❑ ❑ � � Sprinkler System Installations �es,i\ ❑ ❑ ❑ � � Standpipes(Sprinkler Sys) Fire Alarm I � Torch Roofing/Tar Kettle Fire Pumps � Waste Tire Storage ANNUAL � Fire Works ' � FlammableApplication-ANNUAL Valuation of Project � Fuel Tanks Q Other: a:,'3:.�'N`."^�;..:1''.,...........-..r:�":.�..,...+=`.2,„';,"-'.-�-..-..."':•z,:'zz�'y".'..';�. ..t.,^::.'"�Z'.*,"..F>'.-....�,.�..,5=w"^:;w���'^�i;+..'�"•iC`..ri--.'.h'c"".u .r.�`}'}'°^.-uK,��.'.•.�.,..,,.o_�w",�.."a."'�'«"..•�_i.Ni.'�"`..,-�..`S:.'��'°"""'w2'.�.,.,w'w-�....... ......=.-3;�^>::�va:.<":v] , �Ua � G �2.!/�✓'G S Contractor �� � Company s Signature ,;y%. Registered Y/N Fee Current Y/N Address / -�/� .t. Ci Z/J— ' i� � License# F' �QO /Oy ELECTRICIAN Company Signature Registered Y/N Fee Current Y/N Address License# PLUMBER Company Signature Registered Y/N Fee Current Y/N Address License# MECHANICAL Company Signature Registered Y/N Fee Current Y/N Address License# OTHER Company Signature Registered Y/N Fee Current Y/N Address License# _-,,.._..��., -- - � - � ti N,�� � .� .. �-.� _F. .�__- �-�, . n .._�.,. ...>:._ �.-. ..,�.�.._t-_._,.�x.,2,..,..__.u,_..,. --°- -.� . _.S_i...-�v_...,�i.�C..�.��'_'.:..^-.`-:,�«Ara.-rk..::,�.'�-'_-+.«'_":...i,_ ,�l��- -s.. . -...: ....:.. _ ...'. ._ _... _ - . . ., . . - . . ' , - �£".s,;_ " - - - .., . . :--c...-,. . ......�.,.. ., _.. , ..._._'.-a:-.�� �5;"- r .. «.'�'.�r--es...;..�rµ... -. .1_a,. .-�.r . .i. .. � -.. � Directions: ., , ' Fill out application completely. ' - Owner&Contractor sign back of application,.notarized( r,copy of signed contract with ovirner) If over$2500,a Notice of Commencement is r@quired( echanical work over$5000) , ' , Supply two(2)sets of drawings with applicable documen ation " ' � - - _ Allow 10-14 days for review after submittal date. �� Parcel#-obtained from Property Tax Notice(http://appraiser.pascogov.com) NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions° which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictlons. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBlLITIES: if the owner has hired a conhactor or contractors to undertake work,they may be required to be licensed in accordance with state and locai regulations. If the contraotor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended cantractor are uncertain as to what licensing requirements may apply for the _ intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, ff the owner has hfred a contractor or contractors, he is advised to have the contractor(s) sign . portions of the"contractor Block°of this applicalion for which they will be responsible. If you, as the owner slgn as the � contractor, that may be an indication that he is not properiy licensed and is not entiUed to permitting privileges in Pasco - County. TRANSPORTATION IMPACTlU71LITiES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands • that Transportation Impact Fees and Recourse Recovery Fees may apply to the constructiori of new buildings,change of use in existing buildings,or expansion of existing buildings, as specffied in Pasco County Ordinance number 89-07 and 90-07,as amended. The undersigned also understands,that such fees, as may be due,will be identifed at the time of permitting. It ls further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior ta recefving a'certificate of accupancy°or final power release. If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance. FurtheRnore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florlda Statutes,as amended): If valuation of wark is$2,500.00 or more, I certiTy that I, the applicant, have been provided with a copy of the 'Florida Construction Lien Law—Homeowner's Protection Guide°prepared by the Florida Department of Agriculture and Consumer Aifairs. If the applicant is someone other than the°owner",I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the'owner°prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certffy that all the information In this application is accurate and that all wark i will be done in compliance wfth all applicable laws regulating construction,zoning and land development. Appiication is 9 hereby made to obtain a permit to do work and installaUon as indicated. I cerlify that no work or installation has � commenced prior to issuance of a permit and that all wark will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I Understand that the regulaiions of otNer govemment agencies may apply to the intended work,and that it is � my responsibility to identffy what actions I must take to be in compliance. Such agencies include but are not limited to: ' - Department of Environmental Protection-Cypress Bayheads, 1Netland Areas and Environmentally Sensitive Lands,WaterlWastewater Treatment. ' - Southwest Florida Water Management District-Wells, Gypress Bayheads, WeGand Areas, Altering Watercourses. - Army Corps of Engineers-Seawalis,Docks,Navigable Waterways. - Department of Health & Rehabilitetive Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protectlon Agency Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restriclions apply to the use of flll:� - Use of fill is not allowed in Fiood Zone'V°unless expressly permitted. - If the flll materlal is to be used in Flood Zone 'A", it is understood that a drainage plan addressing a ' °compensating volume"witl be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone'A° in connection w(th a permitted building using stem wall construction,I certify that fill wlll be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certlfy that use of such fill will not adversely affect adjacent properties. If use of flil is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building pertnit issued under the attached permft application,for lots less than one(1) acre which are elevated by ftll,an engineered dra(nage plan is required. If I am the AGENT FOR THE OWNER,I promise in gaod faith to inform the owner of the permitting conditions set forth in this eftidavlt prfor to commencing construction. 1 understand that a separate permit may be required for electrical work, plumbing, signs,wells, pools, air condiGoning, gas, or other Installations not speciflcally in�luded in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside arry provisions of the technical codes,nor shall issuance of a permit prevent the Buildirig Official from thereafter � requiring a correction of errors in plans,construction or violadons of any codes. Every permit issued shall become invalid unless the wark authorized by such permit is commenced withfn six months of permit fssuance,or'rf work authorized by the permit is suspended.or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing,irom the Building.Official for a period not to exceed ninety(90)days and will demonstrate )ustifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT � WIT YOUR LENDER OR AN ATTORNEY BEFORE ECORDING YOUR NOTICE OF COMME CEMENT FLORIDA JURAT(F.S.117.03) �/ ^ � �. .��� / A 1 OWNER OR AGENT CONTRACTOR�, ar ���=� Subscrtbed and sworri to(or aftirtned)before me thls Subsalhed end svwm to(or affirtned)before me thls by � bY 1Nho islare e nal Wh slare pers aly to m o has/have pro d P fY 9� Z�6 U1i��:52.:i�X� s!J_ZV''.��c..:«: Bl0 S8E'OOBwuei sulure /� myl P ao'`�ida�`� L LE6 t# a:ss�w.,:c,'� ~''•. T�ti�,,,; 8l0 P S x3 , .�- 0 .ao���6n��"�z'';;,° 6 iss, iuo :•: otaryPublic d '3130P �••.,�a A�,..�� Commisslon Commissl Name of No ry ed,printed or shdmped � Name of Notary ed, 'nted or stamped _.� o. _ �,r �`+ � � r+ - . .�—�.�-"•. , City of Zephyrhills � �j BUILDING PLAN REVIEW COMMENTS . Contractor/Homeowner: �� 5 �' Date Received: `2 — �p � � c.� Site: � � (�A Ll.. �(��/� PermitType: �=1Ri= AL14R�'►� SYSTF_M Approved w/no comments� Approved w/t e below comments: ❑ Denied w/the below comments: ❑ . I � This comment sheet shall be kept with the permit d/or plans. � �� � /r� /� -� � Kalvin Switzer— s Examiner Date Contractor and/or Homeowner (Required when comments are present) � d •� , . � I . ZEPMI'RHlLL FIRE D�P�l��`�F(��� 6907 Dairy R ad, Zephyrhills, FL 33542 ' FIRE SE VICE USER FEES Occupancy No.: Pldi� No.: Contractor: Bu�iness Name: �� Billing Address: Business Address: �� v1�, � U Business Phone No.: Billing Phone No.: Business Fax No.: Billing Fax No.: Contact: Contact: PLAN REVIEW FEES INSPECTION FEES PERMIT FEE FALSE ALARM FEE � Site Plan N/C Annual N/C Sprinkter $50 1st Alarm N/C , 8 Multi-Family/Commercial .06 sf 1st Re-inspection N/C Standpipes $50 2nd Alarm N/C (Minimum Charge$25.00 2nd Re-inspection 100 Fire Pump $50 3rd Alarm N/C � Plan Revisions DBL 3rd Re-inspection 250 H 4th Alarm $100 - 4th Re-Inspection 500 Fire Ala m - $ 0. 5th Alarm $150 SPRINKLER SYSTEMS (Business closed until LP Gas 6th Alarm $200 0-25 Heads $50 violations corrected) a ra Gas $50 NON COMPLIANCE $150 ` 26 plus Heads $100 SPRINKLER SYSTE S Fuel Tanks- pertank $50 STANDPIPE SYSTEM Hydro Undergrounds $45 Sparklers $100 � Per Riser $50 Hydrostatic Test $65 per system Fire Works $500 �, FIRE PUMP Acceptance Test $45 persyslem Camp Fire $25 � Per Pump $100 Hydrant Flow $75 Controlled Bum $100 FIRE ALARM SYSTEM Hood/Duct $50 , 0-25 Dev' FIRE ALARM SYST M Place of Assembly $50 Mnual i plus Devices,i 1 0 System Acceptance 0 Fire Protection $25 I SUPPR SYSTEMS R p nce $50 Flammable Applicatton $50 nnnuai � Wet $50 OTHER Waste Tire Storage $50 Mnual Dry $50 Fire WaI1/Smoke Wall $15 perwall Generator<KW $100 � CO2 $50 LP Gas $25 per tank Generator>30 KW 150 Other $50 Natural Gas $25 persystem Bio-Hazard Waste $100 nnnuai KITCHEN EXHAUST Fumigation Tenting $50 � Hood/Ducts $50 Tent 10'x10'or greater $15 per tent Torch PoUApplied $50 OTHER Fire Pump $45 Haz.Materials $100 nnnuai 8 LP Installation per tank $50 Fire Suppression $30 Fuel Tank Installation $50 System Acceptance (Per Tank) $50 Exhaust Hood/Duct $30 �Natural Gas Installadon $50 Re-inspection DBL (Per System) (other than annual) �Spray Booth $50 � Inspection scheduled DBL � and cancelled less tha 24 hours Construction Insp. N/C Emergency Vehicle A� $50 FALSE ALARM , PLAIdS TOTAL,' �j INSPECTION TOTAL , �} PERMIT TOTAL� TOTAL�— GRAND TOTAL �'� (,�' Comments: � Date: I� Inspector: mn ' i � � -� •�• � .• �.. .. - - �� i i � - -� -�- - � -� �- -�- - - -•- - -�- -' �-- -�_ • . • - ' . �I _ - www.boschsecurity.com II � BOSCH Invented for life ► Support for up to 508 points on two analog p' ��� � ��. addressable loops ► Built-in Ethernet connector for web-browser based programming and Conettix Alarm-over-IP communication ► Two on-board NACs and dual-line PSTN DACT ► Peer-to-peer networking of up to eight—V2 panels in �, a single group ;�. ► Suited to a wide range of applications and compatible with the latest Bosch solutions— � including 440 Series Multi-criteria detectors The FPA-1000 Analog Addressable Fire Panels a e a The panel has a compact and solid metal housing with scalable solution for fire detection. Protect you small a keyed lock and a removable dead front door to office with a single system or connect multiple anels access electronics. It features surface and semi-flush together as your needs grow. Networking capa ilities mounting options. On the front of the panel, six light- support the monitoring of up to 2,000 addressa le emitting diodes (LEDs) show Fire, Carbon Monoxide points in one system for campuses or other lar e (Gas) Alarm, Power, Supervisory, Silenced, and commercial environments. Trouble conditions.The built-in keypad can be used The FPA-1000 panels combine complete built-in Fire for total system control and programming even when Alarm Control Panel (FACP) equipment such as wearing fireman gloves. In addition, a large 4-line by Notification Appliance Circuits (NACs), Signalin Line 20-character alphanumeric LCD display shows Circuits (SLCs), relays, power supply, Digital AI rm programmed device point information. Four keys CommunicatorTransmitter (DACT), and Ethern t enable Drill, Reset, Silence, and Acknowledge connection with expandability using the option us or functions. plug-in boards. The two integrated NACs can b The FPA-1000 panels enable various programming expanded with remote addressable NAC power approaches: boosters and programmed with specific activation • Front panel programming patterns. • On-site programming, using a laptop with the The standard control panel includes one SLC t at possibility of pre-programming at the office supports 254 addressable points (254 analog • Off-site programming,with remote access via detectors or modules, or 127 analog sounder b ses in Ethernet (browser-based). combination with a suitable detector).The con rol Front panel programming provides an auto-learn panel is easily expandable with the FPE-1000-S C function, allowing the installer to configure the system Signaling Line Circuit Plug-in Module, doubling he quickly and easily in default mode. Using a local laptop address points to 508. or remote access communication,the programming is carried out by means of a browser-based user . � -� ��� � . .• �.. - .. - , interface.Therefore, no software installation is control and transmission supervision, priorities of � required.The panel can receive diagnostics from a report groups, routing to destinations, manual and Web browser running on a networked PC. auto test reports, and Anti-Replay feature. For the primary and secondary account,the following ' � features are programmable: • Two different phone or IP numbers =—'�. • Different dialing types for PSTN (pulse only, ;OptionBus�, /��pM3]bOG`� , , ,��FM.,,f� - automatic,or tone only) i /� ` : °;�s"""°�""°�� • Individual PSTN line supervision (audible and visual �MX�IO�PRWD � `'�,�� i�Md<P08/�I50 I � `/iM.• . � �`ti i�;_�.�3�s RM03SISO�j \, trouble signal in the case of a transmission path ('��MRd00}RP l j ,`�3�^�^^� ' failure) _. .�s �„�,����9�11�, ��o�o�� �o=� ;�._���,,,s,�, �; � : Selectable options for Report Steering Groups Di03W45] FLN�375�]I< °'°'°�.� / �,w�� �`� Programmable acknowledge wait time for each IP ! J�.+cdao-n�rc � i�m(IM/H )r�`" flr�IaPC/�ml�oic aua]5.0 Y ' � ���g�<a�a `l ; r e p o rt i n g C o n e t t i x a c c o u n t(1 0 sec up to 2 5 5 sec) 1, �D1035(B ��e�°"�' °"B" �3 . • Test report frequency individually programmable for ; i fADJM�DH fLbL3]5.]M FLAk7]S�71L1�]W�]AI�� ; eiq��p FLM143I`rIA�-0NBN� , each account (4, 12, 24 hour, 7 and 28 day intervals, `� �°'°"""��'°�` � F��u��,a�11 ,' standard frequency 24 hour) iMM-335A FLM�335�NAC ; � j� ��\ FMMJISC-D RM.925�NN4� �� RM3]SCZNO Applications ` \� SLC1 �%�// ,. � . The panels are recommended for a wide range of NerwoRK ---- ��=--,s�c 2..- � commercial and ublic buildin a lications, includin CARDS --- -.,__ _, P g pp� g� `'! Retail-single building applications Fi9E1006NC FPE�IDOOSLC j • �oE-��.�,v� '��� ;� -_ • Education-schools and univ.ersities NAC � • Residential-apartment buildings `� � �� • Commercial-manufacturing plants,warehouses and �.- � ��-`� office complexes /�o�zn�.n,e��a,`• ��l CITYTIE • Government and Public Service-military bases and � oivu�x�nm,oizan�uani� i� \�, installations � �, �� �`°`.�°°°`"� %� • Medical- healthcare facilities ��_v �� �------'' ' Multi-criteria Detectors � A range of pull stations, modules, accessories and � � detectors are available to meet the needs of your Peer-to-peer Communications application.These include the new Automatic Fire � The FPA-1000 panels (-V2) allow peer-to-peer Detector 440 Series that incorporate multi-criteria networking of up to eight panels in a single group technology for higher sensitivity, faster detection, and supporting a system which can include up to 2000 fewer false alarms. points. Gas detection Networked panels act as a single panel -enabling all Integrated gas detection is an important element of events to be displayed on all units.All connected your facility's fire and life safety strategy. Using panels can easily be programmed and controlled via FCC-380 Carbon Monoxide detectors combined with any connected panel. an addressable monitor module,you can set your Ethernet, fiber optic, or 2-conductor wire inter-panel system to alarm for carbon monoxide to meet the connections can be mixed providing flexibility in NFPA 720 (2009) requirements for visual and audibie system design. annunciation for this hazardous gas. System Management Notification Appliance Circuits (NACs) A set of interactive Web pages gives you an instant Two Class A Style Z or Class B Style Y NACs provide up means to access and record important system to 4 A of 24 V power(non-synchronized: 2.5 A per functions.This unique feature enables programming NAC; synchronized: 2.75 A NAC 1 + NAC 2 in total) to and diagnostic capabilities while offsite, streamlining operate horns, strobes, bells, and other notification installation and reducing the time required for appliances. Each NAC can be programmed to provide servicing the system.And,you can check status and Temporal Code 4,Temporal Code 3, and steady, manage the system from virtually anywhere on the pulsing, and synchronized protocol output for network. Wheelock, Gentex, and System Sensor notification Communications appliances. The FPA-1000 panels have a dual phone line PSTN/ DACT circuit and an Ethernet connection featuring Conettix IP reporting. The panels communicate in Contact ID, SIA, and Modem Illaz.The panels provide miscellaneous reporting functions such as dialing : I � ' '� i�� � •• � • .• ` On•board Relays Signaling Line Circuits (SLCs) Three programmable on-board relays default to lobal The panels communicate with each of the analog alarm (zane 226), global system trouble (zone 2 7), addressable devices located on the SLCs.The SLCs ( and global system supervisory {zone 228).They can be allow the use of standard nan-twisted, non-shielded � programmed to activate an a variety of conditio s wiring. Each panei supports two Class B, Style 4 ar including gas alarm. one Class A, Style 6 or 7 per SL.C. ' Glp#ion Bus . . . . . .. . . On the Option Bus,the panels suppart: --- .�____ , - • up ta eig t FMR-1000-RCMD Remote Comman , Region ; Certification Centers and FMR-1Q00-RA Remate Annunciato s in ,.._�.,.�..��a__�_...,.,.,..__ ___. _._,., , __.__._ __.._._._..,._.w� any combination USA � UL FSZI.S1871:EmergencyAlarmSystem ; � • up to eight D7030X Series LED Annunciators ith Contralllnits{ANSiJUE2017};[10JZ: '• eight LED zanes each, � ' Cantrol Units,System(ANSI/UL 864) ` ' • up to eight D7030X SeriesiD7032 combination � � �{� FpA-1000 ^�T • up to twa Octal Relay Modules or Octal Driver ---------------------- ----� - - .___�__.�..____. ._,__�. , Modules CSFM seeourwebsite ; • up to faur FPP-RNAC-8A-4C Remote Notificati n ; -FDNY= �#glp� "� __._. _.�.__.._.„__�___..._. ._� Appliance Gircuit Power Supplies. , CoA . ' The outputs of the Octal Relay Modules or Octa Driver �' ' Madules are fully programmable, and can be ac ivated . . . . . . - by system events.These outputs have the same pragramming aptions as the local relays. Each o tput Mounting Cansiderations � operates independently of the oti�er seven to p vide ��e cabinet can be either sem�-flush {requires opfiianal complete flexibility. Cammunication with the D 035/B FPM-1000-SFMK Semi-flush Maunting Kit) or surface ar D7i}48JB is supervised. mounted. '; f Depending on the configuration and the battery i � PQWer selection, the FPA-1000 can be quite heavy.When A transfarmer working with 120 VAC or 244 VA is attaching the enclasure to a surface, use mounting ` supplied standard with the control panel.Two ackup hardware (not supplied) capable of'supporting this batteries with 7 Ah to 18 Ah each fit inside the re weight, and reinforce the wall as necessary. panel cabinet. A separate battery box can provi e y�►�ring Considerations � higher capacity.An automated battery calculato sheet The length of wire allawed between the contral panel is available online to aid in battery se]ection ar► and the last device on a wiring run depends on the submittal paperwork. current drawn on that wiring run. Reducing the The panels provide two auxiliary power supplie (ane number of devices on a wiring run allows the FWR and one DC) with 0.5 A at 24 V each, with individual runs to be longer. ' switchable AUX/RST. 7his auxiliary power cari r n (f not atherwise specified, use wire gauge 12 AWG to expansion boards ar ather low current auxiliary 18 AWG ()SO 4 mm2 to p.75 mm2). devices. Far instailations requiring battery capacity high r than 40 Ah, a regulated and UL1481 Listed externa( awer � Natice supply can be used.The external power supply Shared cable is not recommended for the Option i cannects fihrough the panel's battery terminals nd is Bus,addrsssable-points bus,telephone,or NAC i supervised for AC and battery fault by an input odule wiring. Do not run wiring for NAC, Optian Bus, on the S�C. and S�C in the same conduit.Avaid shielded or The FPP-RNAC-$A-4C Remote NAC Booster add four twisted-pair wire except far netwark connections additional Notification Appliance Circuits (NFP 72, and special applications where a reduced length Class A Style Z or Class B Style Y} ta the fire pa el ar af wiring(roughly 50°l0} is acceptabie for serves as a power supply for fire pratective sign ling to(erating a harsh electricai enviranment. systems.This regulated power suppiy provides p to 8 A of power that is used to recharge batteries nd Point CapacityjConfiguratian operate continuous and intermittent alarm load .7his Each F'PA-1000-V2 panel supparks up to 508 8 A af pawer can be distributed through the fau R1AC addresses, 254 per loop. For addresses above 127 an Power Supply circuits that are part of the F'PP- each ioop, on(y the FAA-325-B6S Sounder base, RNAC-8A-4C..The FPP-RNAC-8A-4C is UL �isted or use FAP-325-V2F Smoke Detector, FLM-325-14-A, � in commercial fire alarm applications. FLM-325-]4-AI, and FLM-325-[M Cantact Monitars, FLM-325-NA4 and FLM-325-NAI4 Supervised Output • Modufes, FLM-325-2R4-2A and FLM-325-2R4-2A! 2 R Dual Relay Modu(es, and FLM-325-2R4-8A and FLM-325-2R4-8AI 8 A Dual Relay Modules can be used. � � •� ��� � . •• ��• - .• - - ' For systems requiring more than 127 points per loop, � . AUX/FWR: a 0.5Aat24VFWR � use these devices on addresses above 127 and other � Non-switched,power-limited;unfiltered, _� devices below address 127.All compatible detectors ' unsupervised _ � and modules are addressed using the D5070 -------- .--.-_______. .._`_..,_._�; Programmer. • AUX/RST: � 0.5Aat24VDC ; � Switched,power-limited,filtered, � � _� ; unsupervised ; Environmental Quant Component _., 1 FPA-1000-V2 main board Environment: � Indoor,dry , ----- i-�..______,_.. .--.__.�____. �. _..._ 1 Enclosure with transformer Protection Class: � IP 30 T, �.�__�.._.__. .__.____------- -.a_.____ F 1 Enclosure lock and two keysl(replacement key:D102) Relative Humidity: ; Up to 95%,non-condensing 1 Hardware pack Temperature(operating): j +32°F to+120°F(0°C to+4g°C)Y.V�� 3 Wiring labels(one each in English,Spanish,and Temperature(storage): uj +14°F to+131°F(-10°C to+55°C) � j Portuguese) - , Mechanical 2 2.21 kf2 EOL resistors(replacement resistors:EOL-2.2K,8 - �� __. ___—..-._._ per package) Operating Elements ` 3 s Tabs with different language versions for LED and key text • LCD• � 4-line x 20-character display,backiit � Literature(in English,Spanish,and Portuguese) — � ���----� -•-------�--_� ___.___� • LEDs: �� Sixtotal:Fire,GasAlarm,Power, • Installation and Operation Guide . Supervisory,Silenced,and Trouble � • OperatinglnstructionSheet - __._.. �._._. _ ..__.._.__�______.__.__.. _ • Release Notes • Operation Keys: j Drill,Reset,Silence,and Acknowledge � ,. �_____-----.� __.___.___... _.____._ 1 Key code stamped on both lock and key • Alphanumeric � 12 alphanumeric keys,escape,enter, , Keypad: ' and navigation buttons(left,right,up, , .• . j down) o � Electrical Interfaces ���______..____...___-.-.--__._. _ .._._ _f • PSTN/DACT: ; 2 lines,RJ45 � �� � 'v i PowersuPP�Y�Primary) __.�_ !__.._. ---------- -._.�_�_._.u_.___.____ " • Current: � 120 VAC:2 A maximum ��� • Ethernet: 1 x RJ45 , 240VAG1Amaximum ------.__._�__..... _.___� ...�_. _.. �_.._._� _._...___. v______ ______._._______._.___.. _ • Peer-to-peer ; Each interconnected panel requires one y • Voltage: � 120 VAC,60 Hz or 240 VAC,50 Hz , communication: i of the following: ; _� _ __._.._.._ ; • FPE-1000-NE Networking Card s Powersupply(secondary) ; 3-Ethermet - p - i- ------- -----. , • FPE-1000-NFNetworkingCard ! • Current(alarm): � • Panel<0.240 A 1-Ethernet 2-Fiber Optic • SLC=0.63 A maximum � { • FPE-1000-NW Networking Card � �_.__.._._._-----. ...___-- ------__ _.� , . � 1-Ethernet2-Wired ! • Current(load): � Standby:<1.25 A ; —___�___ _�i..____.___.._, __.H_______. _._.._ ; ` NetworkConnections i ' Alarm:4ASharedmaximum , -.__. --_______._._._.. ___—__. ._.__.____.� � • NAC 1=2.5 A maximum • Ethernet: ! minimum of CAT 5 cable at a maximum ; : ' • NAC 2=2.5 A maximum � ' length of 328 ft(100 m) � ' • AUX/FWR=0.5 A maximum _.__.._,---�._..,...__..—�._ ______f • AUX/RST=0.5 A maximum • Fiber Optics: ' multi-mode fiber optic cable(62.5 um/ , � • Option bus=0.5 A maximum ° 125 um fiber size;1270 nm to 1380 nm • _ ,._- _-__.._.^. _._.-.____-_--_�. _.. ' wavelength)with LC connectors at a i • Voltage: 24 VDC ', maximum length of 6560 ft(2000 m or a � - -- , 10 db loss,whichever occurs first) � Batteries —__.�_ ___ _�___ . �._._ _---._._ .._._.._____, �— • Wired: ° 12 AWG(2.05 mm)to 26 AWG ; • Voltage: 2 x 12 VDC in series ; �, (0.41 mm)twisted pair wire(shielded or � • Capacities: : maximum 40 Ah � ' , unshielded)at a mauimum length of • in cabinet:7 Ah to 18 Ah • 2952 ft(900 mj or CAT 5 cable'or better � � • in additional battery box:24 Ah at a maximum length of 3280 ft � , to 40 Ah �� ' (1000 m) ___�_ ._—.._ _...___ i !_.�.---° - • Fuses: � 15Abladetype�__.____�------___.__ Wiring _�___.._---____._ ____---�_.__ ._�..__._ � �""-'�- --'�-�--"-�� • Cable Entries: • Triple knock-outs(3/4,1/2,1 in) � Ainciliarypowersupply(AUX) --_- _._.— _ .�__. _____ } 1 '� ��• � . •• ��• - .• ' ' ' • Connections: • PluggableterminalblocksforAU , � D7030XLEDAnnunciator � Option Bus,SLC,NAC,Main Boa Eight zone LEDs indicate alarm conditions. ; Relays Order number o7o3oX • Wire Gauge: , 12 AWG to 18 AWG(ISO 0.75 m z to� � D7030X-S2 LED Annunciator ; 4mmz) _ _ , Tw.o LEDs indicate supervisory conditions; six indicate __. ._.. �______.._.._.__. Enclosure � alarm conditions. • Material: ' Cold rolled steel,l9.gauge(1.2 m) f Order number D7o3oX-52 � _._. �_._._...__.�.___..-—--- ----,----._.__. • Color: ; Red D7030X-S8 LED Annunciator ', _._. _.._________. ._ ... ___ __�__ , All eight zone LEDs indicate supervisory conditions. Dimensions Order number D7o3ox-s8 • Enclosure(W x H x + 14.5 in.x 4.3 in.x 22.7 in. � D7032 Eight-zone LED Annunciator Expander D): ; (36.8 cm x 10.9 cm x 57.7 cm) Use with D7030X LED Annunciators • with trim ring(W x ! 17.5 in.x 25.6 in.(44.5 cm x 65. cm) � Order number D7o32 D): � r _. ____.__ _._._._ ______ __._._. ; D7035 Octal Relay Module • Semi-flush i 3.25in./1.05in.(8.25cm/2.7cm) Provide eight Form C relay outputs (w/o enclosure) for mounted(H ' , the D7024, FPD-7024, or FPA-1000 Fire Alarm Control recessed/H ' Panels (FACP) flush): , Order number�7035 Weight(enclosure): `, 18:1 Ib(8.32 kg) , ^W v _�y D7035B Octal Relay Module with Enclosure ' � � _ � � Provide eight Form C relay outputs (w/enclosure) for i the D7024, FPD-7024, or FPA-1000 Fire Alarm Control , FPA-1000-V2 Analog Addressable Fire Panel Panels (FACP) Order number FPA-1000-V2 Order number D70356 � FPA-3000-LT Analog Addressable Fire Panel less rans- D7048 Octal Driver Module former Module and hardware Analog Addressable Fire Panel without transfor er for Order number��oas � Latin America only D7048B Octal Driver Module with Fire Enclosure Order number FPA-1000-LT _ Module, mounting plate, metal enclosure, and Accessories hardware BATB-40 Battery Box\Enclosure Order number D7o4s6 The BATB-40 Battery Box holds two dry or wet ell FAA-325-2.5 Sampling Tube(2.5 ft)� ' batteries.The box can be used with fire alarm stems 2.5 ft (762 mm) long sample tube for use with the or intrusion systems. FAD-325 and FAD-325-R Analog Duct Detectors Order number BATe•ao Order number FAA-325-2.5 BATB-80 Battery Box\Enclosure with Shelf FAA-325-5 Sampling Tube(5 ft) ' The BATB-80 Battery Box holds up to four dry o wet 5 ft (1.52 m) long sample tube for use with the cell batteries.The box can be used witti fi�e ala m FAD-325 and FAD-325-R Analog Duct Detectors systems or with intrusion systems. Order number FAA-325-5 Order number BATB-8o �,�,,_w FAA-325-10 Sampling Tube(10 ft) BATB-SHELF Optional Battery Shelf 10 ft (3.05 m) long sample tube for use with the An optional battery shelf for the BATB-40. It all ws two ee s additional batteries to be laced in the batte ox. FAD-325 and FAD-325-R Analog Duct D t ctor p ry Order number Fau4-325-to Order number BATB-SHELF ___ ������ �v FAA-325-B4 4inch Analog Sensor Base D102 Replacement Key Is combined with analo addressable detectors that i g Re lacement ke #1358 for LOCK-1358 and t e . P y � � use the advanced digital communication protocol to D101 lock. Order number�loz provide early fire warning for life safety and property __ protection D5070 Analog Device Programmer _ Order number FAA-325-84 Programs address settings on EEPROM-progra mable � analog devices Order number�5070 , '� •�• � . •• ��• .• - ` FAA-325-B6 6-inch Analog Sensor.� Base� FAI-325 Analog lonization Smoke Detector 6-inch (152.4 mm) base for FAH-325, FAI-325, and For early warning of trouble from superheated or FAP-325 sensors. US sales only! flaming combustibles wh.ere outside RFI and other Order number FAA-325-B6 electrical interference is expected. US sales only! Order number FAI-325 FAA-325-B65 Analog Sounder Base —.._. Contains an addressable sounder which provides an FAP=325=V2F Analog-Photoelectric-Smoke Detecto�Flat> audible alarm in the immediate vicinity and only works Used to detecf-fast=flaming-fires°and'dense smoke in combination with one of the FAH-325, FAI-325, or typically given off by plastic, foam, paper,wood, and FAP-325 series analog sensors other materials that tend to smolder Order number FAA-325-B6S , Order number FAP-325-V2F FAA-440-B4 Analog Standard Base 4inch FAP-440 Analog Photoelectric Detector Order number F�-44o-aa � Order number FAP-4ao FAA-440-B41S0 Analog Isolator Base 4inch FAP-440-D Analog Dual-Photoelectric Detector Order number F/�A-44o•B4-ISO Order number FAP-440-D FAA-440-B6 Analog Standard Base 6•inch FAP-440-DT Analog Multisensor Detector Dual-Photo/ Order number FAA-44o-BS Heat ` Order number FAP-440•DT FAA-440•B6•ISO Analog Isolator Base 6-inch �-�. Order number Fa4-4ao-e6-ISO FAP-440•DTC Analog Multicriteria Detector Dual-Photo/ -' " � Heat/CO � FAD-325•DH Analog Duct Smoke Detector Replacement Order number FAP-44o•DTC Head — Two-wire replacement detector for the FAD-325 and FAP-440-T Analog Multisensor Detector Photo/Heat FAD-325-R duct housings has adjustable threshold Order number FAP-440-T smoke level and automatic compensation values. It has — EEPROM addressing with the D5070, two polling and FAP-440-TC Analog Multicriteria Detector Photo/ _ detector status LEDs for 360�view, and easy removal Heat/CO for cleaning and servicing. Order number FAP-4.ao-rc Order number FAD-325-DH � FCC-380 Carbon Monoxide Detector•(Macurco CM-Ei) FAD-325 Analog Duct Detector Carbon monoxide detector Housing for use in heating,ventilation and air Order number Fcc-aao conditioning systems (HVAC) that comes with an FLM-325-214-Dual-Input-Monito� � FAD-325-DH Analog Duct Smoke Detector Provides two independent contact monitoring circuits Replacement to monitor Normally Open (NO) or Normally Closed Order number FAO-sz5 � (NC) dry contact types of fire alarm devices FAD-325-R Analog Duct Detector with Relay Order number FLM-325-214 Duct detector housing comes with an FAD-325-DH FLM-325-NA4 Supervised Output Module(Class A and Analog Duct Smoke Detector Replacement and two B� sets of Form C alarm. It's easy to install with a drill Can be wired for Class A or Class B circuits; template and the steel sampling tube means there are compatible with 254 addresses - no screens or filters to clean. US sales only! Order number FLM-325-NA4 Order number FAD-325-R �,._.._ ___._�. FLM-325-NAI4 Supervised Output Module(Class A and FAH-325 Analog Heat Detector B,with isolator) Used in indoor environments with high ambient Built-in short circuit isolator circuitry; can be wired for temperatures such as kitchens, boiler rooms, or drying Class A or Class B circuits; compatible with 254 rooms; compatible with 127 addresses addresses Order number FAH-325 Order number FLM-325-NAI4 FAH-440 Analog Heat Detector FLM-325-2R42A Dual.Relay Module 2 A Use with FAA-440 Series bases and FAP-1000 Analog Provides 2 A current at two independently-controlled Addressable Fire Panels to provide general property Form C contacts for a variety of Normally Open and ' protection Normally Closed applications; compatible with 254 Order number FAH-44o addresses ', Order number FLM-325•2R4-2A � '� ��• � . •• ��• - .• - FLM-325-2R42AI Dual Relay Module 2 A with Iso ator FMM-325A_Single=action Menual Station i Provides 2 A current with built-in short circuit i olator The single-action manual station is UL listed for circuitry at two independently-controlled Form commercial fire applications and meets Americans contacts for a variety of Normally Open and No ally with Disabilities Act (ADA) requirements. Its address Closed applications; compatible with 254 addr sses on the polling circuit is set by programming an Order number FLM-325-2R4-2AI EEPROM microchip with the D5070 Analog Device ,---------- Programmer. FLM-325-2R4-8A Dual Relay Module 8 A '; Order number FMM-325A Provides 8 A current at two independently-cont olled .-� �--� Form C contacts for a variety of Normally Open nd FMM-325A-D Double•action Manual Station ' Normally Closed applications; compatible with 54 The double-action manual station is UL listed for addresses commercial fire applications and meets Americans Order number FLM-325-2R4-8A with Disabilities Act (ADA) requirements. Its address FLM-325-2R48AI Dual Relay Module 8 A with Iso ator on the polling circuit is set by programming an EEPROM microchip with the D5070 Analog Device Provides 8 A current with built-in short circuit i olator Programmer. circuitry at two independently-controlled Form Order number FMM-325A-D contacts for a variety of Normally Open and Nor ally .-.__ - - Closed applications; compatible with 254 addr sses FMR-1000•RA Remote Annunciator Order number FLM-325-2R4•8A1 LCD annunciator without system control capability for �- �"" use with the FPA-1000 Analog Addressable Fire Panels FLM-325-CZM4 Conventional Zone Module Order number FMR-1000-RA I Enables the FACP to interface and monitor up t 25 --- conventional devices depending on the device t pe FMR-1000•RCMD Remote Command Center � such as two-wire smoke detectors or pull statio s LCD annunciator with system control capability for use Ordef number FLM-325-CZM4 with FPA-1000 Analog Addressable fire Panels �` —`""!� " '� Order number FMR-1000-RCMD FLM-325-14A Contact Monitor 4inch Class A — - Can be wired for Class A or Class B circuits; mo nted FPE-1000•CITY City Tie Plug-in Module to a cover plate for a 4-inch square or double g ng Provides the FPA-1000 Analog Addressable Fire Panels electrical back box; bi-colored LED provides mo ule with two supervised City Tie Local Energy circuits or , status; compatible with 254 addresses Reverse Polarity circuits I Order number FLM-325-14-A Order number FPE-1000-CITY FLM-325-14-AI_Contact-Monitor 4inch Class A wit Isola� FPE-3000-NE Networking Card 3-Ethernet tor Ethernet Networking Card for peer-to-peer � Can be wired for Class A or Class B circuits; ha communication in an FPA-1000-V2 networked system built-in short circuit isolator circuitry; mounted o a Order number FPE-1000-NE cover plate for a 4-inch square or double gang �`�W� �� �� ``- electrical back box; bi-colored LED provides mo ule FPE-1000-NF Networking Card 1-Ethernet 2•Fiber Optic status; compatible with 254 addresses Fiber Optic Networking Card for peer-to-peer Order number FLM-325•14-AI communication in an FPA-1000 networked system -- — Order number FPE-1000-NF FLM-325-IM Contact Module �- -" Allows compatible fire alarm control panels (FA P) to FPE-1000-NW Networking Card i-Ethernet 2-Wired supervise Form A or B dry contact devices in a olling �Nired Networking Card for peer-to-peer circuit communication in an FPA-1000 networked system Order number FLM-325-IM Order number FPE-1000-NW FLM-325•ISO Short Circuit Isolator FPE-1000-SLC Signaling Line Circuit Plug-in Module Isolates a shorted section on a specific polling ircuit Provides a Signaling Line Circuit (SLC) for connection from the rest of the system to minimize the loss of of analog devices to the FPA-1000 Analog Addressable communication Fire Panels Order number FLM-325•ISO Order number FPE-1000-SLC ��� �� ~ FPM-1000-ENC Enclosure with Dead Front Door Enclosure with dead front door Order numbef FPM-1000-ENC I • I I - -� ��� � . .• �.. - .. - - • - FPM-1000•SFMK Semi-flush Mountin Kit g The FPM-1000-SFMK Semi-flush Mounting Kit includes a trim ring and 4 screw covers. Order number FPM-1000-SFMK _ . _ FPP-RNAG_8A-4C_Remote Notification Appliance-Circuit- �(RNAC) P_ower Supply_' The FPP-RNAC-8A-4C adds four additional NFPA 72, I Class B (Style Y) or Class A (Style Z) notification appliance circuits to a fire alarm control panel (when connected via the option bus), or is a NAC power supply for fire-protective signaling systems (when connected directly to the NAC output). Order number FPP•RNAC•8A•4C —�_,.__ T . i . • i Represented by: Ameriws: Europe,Mlddle East,Africa: Asia•Paci(ic: China: Amertca Latina: Bosch Security Systems,Inc. Bosch Security Systems 6.V. Robert Bosch(SEA)Pte Ltd,Security Bosch(Shanghai)Security Systems Ltd. Robert Bosch Ltda Security Systems Division 130 Perinton Parkway P.O.Box 60002 Systems 201 Bullding,No.333 Fuquan Road VIa Anhanguera,Km 98 Fairport,New York,14450,USA 5617 BA Eindhaven,The Netherlands 11 Bishan Street 21 North IBP CEP 13065-900 Phone:+1 800 289 0096 Phone:+31 40 2577 284 Singapore 573943 Changning District,Shanghai Campinas,Sao Paulo,Brazil Faz:+1 585 223 9180 Fax:+31 40 2577 330 Phone:+65 6571 2808 200335 Chlna Phone:+55 19 2103 2660 se<urity.salespus.bosch.com emea.securitysystemspbosch.com Fax:i65 6571 2699 Phone+86 21 22181111 Fax:+55 19 2103 2862 www.boschsecurity.us www.boschsecurity.com apr.securitysystems@bosch.com Fa�c:�86 21 22182398 latam.6oschsecurity@bosch.com www.boschsecurity.asla www.boschsecurity.com.cn www.boschsecurity.com �Bosch Security Systems 2014�Data subject to change without notice 2690096139 I en,V8,31.Jul 2014 �� S�srErv� - -�- _- . �� , , �� .!���vso�� :���� ,, � '. �a f � -, ",,ni'� '., � � �`` �',,����1f � ( R j .,/ I � Indoor Selectable- � �'��° � ` �� _� C1ut ut Horns 4�� � p � ,�=�. �. � �.� � S#�rof��s; and _ , •� 1 �� , �� , � ,�� , � � �orn�atrobes-for� ' w� �- �� a -��, �'_ 7``� s� �,� a _ Wall A lications - �-��:� �� ti �__., pp �►�-:__- .; . � SpectrA/erf�Advance audib/e vrsi6le nofifiea�ion radr�cfs �, are rich wirh feafures uaranteed ro cu�ir�sfallafian fimes SPEC�TR��I�e� j g Aav �► n� cE and maximize profits. Features The SpectrAlert Advance series offers the mosi versatile and . easy-to-use line of horns,strobes,and horn strobes in the indusiry. • Plug-in design with minimal intrusion into the beck box Wiih white and red plastic housings>wall and ceiling mounting • Tamper-resistant constructian options,and p(ain and FIRE-printed devices,SpecirAlert Advance �I � � • Automatic selection of 12-or 24-volt operation at 15 and can meet virtually any application requirement. � 15t75 candela • Field-selectable candela settings on wall units:15,15/7 ,30,75, Like the entire SpectrAlert Advance product line,wall-mount homs, i sirobes,and horn sirabes inciude a variety of feat�res that increase 95,110,115, 135,150,177,and 185 their application versatility while simp�ifying instailation.All devices • Horn rated at 88+dBA at 16 volts feature plug-in designs with minimal intrusian into the back box, • Rotary switch far hom tone and three volume selections making insta(lations fast and faolproof while virtually eliminating costly and time-consuming ground faults. • Universal mounting plate for wall units • Mounting plate shorting spring checks wiring continuity efore To further simplify installation and protect devices from construction device installation damage,5pectrAlert Advance.utilizes a universa!mounting piate • Electrically Compatible with legacy SpectrAlert devices with an onboard shorting spring,so installers can test wiring, continuity before the device is installed. • CompatibEe with MDL sync madule • Listed far ceiling or wall mounting Installers can also easily adapt devices to a suit a wide range of application requirements using fieEd-se[ectable candela settings, automatic selection of 12-ar 24-volt operation,and a rotary switch for horn tones with three valume selections, A enc Listin s SIGNALING ;" 4}' {�,i�/'l ✓� i ll� �M . .. LISTED APPflOVED appYqVed ��254653'1 8(horn�SbOb seS� 54017{ohimes,horn strobes,nprns) 3023572 MEA452-05-E chime strobes) , S55S2(strabesl 7135-1653:1 9(harns,chimes) �I . ' SpectrAlert Advance Specifications ' General SpectrAlert Advance horns,strobes,and horn strobes shall mount to a standard 4 x 4 x 1 Yz-inch back box,4-inch octagon back box,or double-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shali be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•CircuiY"'Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8 and 17.5 volts;24-volt-rated notification appliance circuit outputs shail operate between 16 and 33 volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95, 110, 115,135, 150,177,and 185. , Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and compiy with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch , between a temporal three pattem and a non-temporal(continuous)pattern.These options are set by a multiple position switch.On four-wire , products,the strobe shall be powered independently of the sounder.The horn on hom strobe models shall operate on a coded or non-coded power suppiy. ' S�nchronization Module The module shall be a System Sensor Sync•Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall aiso - control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DClFWR' Operating Voltage Rangez S to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) InputTerminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6""L x 4.7""W x 2.5"D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6""L x 4 7'"W x 1.3'"D(142 mm L x 119 mm W x 33 mm D) Wall-Mount Back Box Skirt Dimensions(BBS-2,BBSW-2) 5.9""L x 5.0""W x 2.2"D(151 mm L x 128 mm W x 56 mm D) Wall-MountTrim Ring Dimensions(sold as a 5 pack)(TR-HS,TRW- 5.7"'L x 4.8"W x 0.35"D(145 mm L x 122 mm W x 9 mm D) HS) Notes: 1 Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS00601 � UL Current Draw Data ..- . . 8-17.5 Volts 16-33 Its 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 �75 NA NA 158`? 153 Non-temporal High 57 56 69 75 95 NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 _ � . ..- .- . 8-17.5 Volts 1 33 Volts DC Input 15 15l75 15 15l75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 , Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 10 112 126 181 203 221 229 , Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 . . ..- . . i 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal'Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Tones and Sound Out ut Data P . . . - • 8-17.5 6-33 24-Volt Nominal Slivitch Volts olts Reverberant Anechoic Position Sound Pattern dB DC FWR C FWR DC FWR DC FWR , � 1 Temporal High 78 78 4 84 88 88 99 98 2 Temporal Medium 74 74 0 80 86 86 96 96 3 Temporal Low 71 73 6 76 83 SO 94 89 4 Non-Temporal High 82 82 8 88 93 92 100 100 5 Non-Temporal Medium 78 78 5 85 90 90 98 98 6 Non-Temporal Low 75 75 1 81 88 84 96 92 7t Coded High 82 82 8 88 93 92 101 101 8t Coded Medium 78 78 5 85 90 90 97 98 9t Coded Low 75 75 1 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strob s. AVDS00601 . SpectrAlert Advance Dimensions 4.7'� 2.5" 5.05" �2.23� ��� � � �`� �� o QQ � � 5.6„ 5.98„ o � o � � � � � � ° A � � Wall-mount horn strobes Wall back box skirt SpectrAlert Advance Ordering Information .- .- . Wall Hom Strobes Horns P2R*t 2-Wire Horn Strobe,Standard cd#,Red HR Horn,Red P2RH' 2-Wire Horn Strobe,High cd,Red HW Horn,White P2W* 2-Wire Horn Strobe,Standard cd,White Accessories P2WH' 2-Wire Horn Strobe,High cd,-White BBS-2 Back Box Skirt,Wall,Red P4R' 4-Wire Horn Strobe,Standard cd,Red BBSW-2 Back Box Skirt,Wall,White P4RH 4-Wire Horn Strobe,High cd,Red TR-HS Trim Ring,Wall,Red P4W 4-Wire Hom Strobe,Standard cd,White TRW-HS Trim Ring,Wall White Wall Strobes SR*t Strobe,Standard cd,Red SRH*t Strobe,High cd,Red SW' Strobe,Standard cd,White SWH* Strobe,High cd,White Notes: 'Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g.,P2R-P t Add"-SP"to model number for"FUEGO"marking on cover,e.g.,P2R-SP. _ $"Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd"refers to strobes that include 135,150,177,and 185 candela settings. � SYSTEM m2072SystemSensor. 3825 Oh10 AVef1Ue�Si.Chflf125, IL 60174 Protluctspecitica6onssublecttochangewithoutnolice.YSitsystemsensoccom �� SENSOR� Phone:800-SENSOR2•F2X:630-377-6495 forcurrentproductinformatlon,inclutlingthelatestvers�onolthistlatasheet. AVDS00601•3/12 �� SYSTEM �� - - �� SENSOR� � ,����,,, ��, ;.,� w. °� ,,�} = ��' / Indoor Selectable- , Output Strobes an �- � �� ��� �. - - _ �'� �� �,�. Ho.-r-n Strob�e_s for � Ceilin A licatio s � � � � ` `` J pp ,�� _;...:-, . t\�` `l „� ir�irr� r r,4� �f , �.,--" .»''� �� SpectrA/ert�'Advance audible visible notification roducts 3fa1� ''� � are rich wifh features guaranteed to cut installatio times SPECTfl��C� and maximize profits. A n v A N c E Features The SpectrAlert Advance series offers the most versatile and ' • Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry. With white and red plastic housings,wall and ceiling mounting • Tamper-resistant construction options,and plain and FIRE-printed devices,SpectrAlert Advance • • Automatic selection of 12-or 24-volt operation at 15 an can meet virtually any application requirement. 15/75 candela • Field-selectable candela settings on ceiling units: 15, 1 5,30, Like the entire SpectrAlert Advance product line,ceiling-mount strobes and horn strobes include a variety of features that increase 75,95, 110, 115, 135, 150, 177,and 185 their application versatility while simplifying installation.All devices • Horn rated at 88+dBA at 16 volts feature plug-in designs with minimal intrusion into the back box, • Rotary switch for horn tone and three volume selections making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. • Universal mounting plate for ceiling units • Mounting plate shorting spring checks wiring continuity efore To further simplify installation and protect devices from construction device installation damage,SpectrAlert Advance utilizes a universal mounting plate • Electrically Compatible with legacy SpectrAlert devices with an onboard shorting spring,so installers can test wiring • Compatible with MDL sync module continuity before the device is installed. • Listed for ceiling or wall mounting Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with three volume selections. A enc Listin s SICNALING 'r��'t UL F M M� � .. LISTED APPROVED approved 7125-�653186(intloorstrobes) 7125-1653 188(hom strobes, 54011(chimes,horn strobes,horns) 3023572 MEA452-OS-E chime strabes) 55572(strobes) 77 35-7 653 189(horns,chimes) SpectrAlert Advance Specifications -- - . General SpectrAlert Advance strobes and horn strobes shall mount to a standard 4 x 4 x 1'h-inch back box,4-inch octagon back box,or double- gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,SpectrAlert Advance products,when used with the Sync•Circuit'"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95,110,115,135, 150, 177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Hom Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.On four-wire products,the strobe shali be powered independently of the sounder.The horn on horn strobe models shall operate on a coded or non-coded power supply. Syrnchronization Module The module shall be a System Sensor Sync•Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/S-inch back box.The module shall also . control two Sryle Y(class B)circuits or ohe Sryle Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. - . • Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%a non-condensing Strobe Fiash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' Operating Voltage Range2 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) InputTerminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8""diameter x 2.5"high(173 mm diameter x 64 mm high) Ceiling-Mount Back Box Skirt Dimensions(BBSC-2,BBSCW-2) 7 1"diameter x 2.2"high(180 mm diameter x 57 mm high) Ceiling-MountTrim Ring Dimensions(sold as a 5 pack)(TRC-HS, 6.9"diameter x 0.35"high(175 mm diameter x 9 mm high) TRCW-HS) Notes: 1 Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS00501 UL Current Draw Data ..- . 8-17.5 Volts 16-33 Volts I Candela DC FWR DC FWR Standard Candela Range 15 123 128 66 71 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 �'11'5-� NA NA f 210_' 205 High 135� NA NA 228 207 Candela Range 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 � - - , 8-17.5 Volts • •• 1 33 Volts , DC Input 15 15l75 15 15/75 30 75 95 110 115 ' Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 SO 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 � Non-TemporalLow 131 144 68 79 96 156 182 201 210 FVIIR Input Temporal High 136 155 88 97 112 168 190 210 218 , Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 10 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 � .- . 16-33 Volts 16�33 Volts DC Input 135 150 177 185 FVI/R Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn StrobeTones and Sound Output Data . ..- • . .: 8-17.5 16-33 24-Volt Nominal Slivitch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 SO SO 86 86 96 96 3 Temporal Low 71 73 76 76 83 SO 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporai Medium 78 78 85 85 90 90 �, 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 7r Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 76 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn stro es. � AVDS00507 � I SpectrAlert Advance Dimensions 7.1° �2.25� 6.8" Dia. Q,� Dia. C/� o � Q � � 2.5" O � � � � 0 Ceiling-mount horn strobes Ceiling back box skirt SpectrAlert Advance Ordering Information - .- •- Ceiling Horn Strobes Ceiling Strobes PC2R' 2-Wire Horn Strobe,Standard cd,Red SCR Strobe,Standard cd,Red PC2RH 2-Wire Horn Strobe,High cd,Red SCRH Strobe,High cd,Red PC2W't 2-Wire Horn Strobe,Standard cd,White SCW* Strobe,Standard cd,White PC2WH* 2-Wire Horn Strobe,High cd,White SCWH Strobe,High cd,White PC4R 4-Wire Horn Strobe,Standard cd,Red Accessories PC4RH 4-Wire Horn Strobe,High cd,Red BBSC-2 Back Box Skirt,Ceiling,Red PC4W 4-Wire Horn Strobe,Standard cd,White Back Box Skirt,Ceiling,White TRC-HS Trim Ring,Ceiling,Red TRCW- Trim Ring,Ceiling,White HS Notes: "Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g.,P2R-P t Add"-SP"to model number for"FUEGO"marking on cover,e.g.,P2R-SP $"Standard cd"refers to strobes that include 15,15J75,30,75,95,110,and 115 candeia settings."High cd"refers to strobes that include 135,150,177,and 185 candela settings. � SYSTEM 02072SyetemSensor. 3825 Ohio Avenue•St.Charies,�L 60174 Productspecificabonssubjectrochangewithoutnouce.Visitsystemsensoccom �� SENSORO Phone:800-SENSOR2•Fax:630-377-6495 (orcurrentproductintorrr�tlon,mcludingmelatestversionotmisdatasheet. I AVDS00507•3/12 a