Laserfiche WebLink
. . ; ., � � � <br /> . ' .. <br /> IZ � 1� �iI�uilding Consultants, Inc. <br /> � Consulting and Engineering Services.for[he Building Industry <br /> � P.O.Box 230 Valrico,FL 33595 Photie 813.659.9197 <br /> Florida Board of Professional Engneers Cectificate of Authori�ation No.98I3 <br /> � � i . <br /> I <br /> Product <br /> Category Sub Category iWanufacturer Product PJame <br /> NewSouth YYindow Soluttons eVan4age <br /> 1Nindows Double Hung 4901 Oak Fair Blvd Qouble Hung Window <br /> Tampa,FL 33610 "Non-ImpacY' <br /> 693 284.0129 <br /> Scope: Product Evaluation report issued by R W Building Consultants,Inc.&Lyndon F.Schmidt,P.E.(System ID#1998)for <br /> NewSouth Windovu Solu6ons,based on Rule Chapter No.9N-3,Method"1A of the State of Florida Produc4 Approval,Dept. <br />� of Business&Pr6fessional Regulation: <br /> RW Building Consuftants and Lyndon F.Schmidt,P.E.do not have nor will acquire fi�ancial interest in the company <br /> manufactaring or disfributing the product or•in any o4her entity involved in the approval process of tlie product named <br /> herein. <br /> Licnifations: <br /> 1.This product has been evaluated and is in compliance with the 2010:FIorida Building.Code(FBC)structural requirements excluding.the <br /> "High Velocity Olumcane Zone",(HVHZ).See the Certifiication Agency Certi�cate for sizes,specifications and rafings. <br /> 2. Product anchors shall be as listed and spaced as shown on details.Pinchor embedment 4o base material shall be beyond wall dressing <br /> or stucco. ' <br /> 3.When used in.areas requiring;wind bome deb�is protection,this product is required to be protected with an impact resistant covering <br /> that complies with Section 1609.1:2 of.the Florida Building,Code. <br /> I4. For 2x stud iraming-construction,ancfioring.of these units shall be 4he same as that shown for 2x buck masonry construction. <br /> 5. Site conditions that deviate from the d"etails of drawing FL-15378.8 require further engineering analysis by a licensed engineer or <br /> registered architect. <br /> 6. See drawing FL-15378.8 for size and_design pressure limitations. <br />, Sapporting Duc�emEnts: <br /> 1. Fest Reaa�ek�90. Yes4�Standard Tesfinca Laboraforv Siqreed i�v <br /> i ATI A6123.01-401=44 AAMA/WDMklCSA 101/I.S:2/A440-OS Architectural Tes4ing,Inc. Don Belfz <br /> 2. Drawina Plo. Rreuared Exv Siqned&S"ealed bv <br /> No.PL-15378:8 RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. <br /> 3. Calcu9ations t°rec�ared bv Sic¢�ed�Sealei bv <br /> Anchoring RVV Building Consultants,Inc.(CA#9813), Lyndon F.Schmidt,P.E. <br /> 4 QualiYv.'�lssvrance � <br /> Certi icate or Participation issued b Ke stone Certifications Inc. cerf'in that NewSouth Window Solu' i <br /> Y Y, ny g tions s <br /> manufacturing products within:a qualify assurance program that complies with ISO/IEC 17020 and Guide 53. <br /> C-�� , <br /> Lyndon F.Schmldt,P.E. <br /> , FL PE No.4940�J <br /> PF 1651 Sheet 1 of 1 3/28/2012- <br />