Laserfiche WebLink
� Site Preparatlon <br /> POCKET PENETROMETER TEST <br /> Debris and organic materiai removed <br /> - The pocket penetrometer tests are rounded down to 1�psf Water drainaqe:Natural_��Swale Pad Other <br /> � or check here to declare 1000 Ib.soil without testing. <br /> astenlnp multl wide units <br /> x�vD x]�pb x 15pD - <br /> � � - Floor: Type as Length: S <br /> � ' Walls: Type Fastener: Length: � pacinq: <br /> POCKET PENETROMETER TESTING METHOD Roof: Type Fastener: Spacing: <br /> For used homes a min. upe,8 , anized metal strip <br /> - 1. Test the perimeter of the home at 6 locatlons. will be centered ov e peak of the roof and fastene 'th-�� <br /> roofing_nails on center on both sides of the centerline. � <br /> 2: Take the.reading at the depth of the footer. <br /> GBSket fweathamrootina roaulremenl►' n <br /> 3. Using 500 Ib.increments,take the lowest _ <br /> reading and round down to that increment. I understan �roperly Instalted gasket is a requirement of all new and used <br /> � homes and that ensation,mold,meldew and buckled marrlage walls are <br /> a result of a poorly ins d or no gasket being installed. I understan rip <br /> �11.�,1�_(� X,�Ob X(�pb of tape will not serve as a ga <br /> � , Ins r's i ' <br /> TORGIUE PROBE TEST � � <br /> ' Tvpe qasket � stalled: <br /> , The resuits of the torque probe test is o�71 e_inch pounds or check - Pg. � Between Floors� e <br /> here if you are declaring 5'anchors without testing . A test , � Between Walis Yes <br /> showing 275 inch pounds or less will requi�e 5 foot anchors, - � - - . - Bottom of ridgebeam Yes ` <br /> , Idote: A state approved lateral arm system is being used and 4 ft. � ` <br /> anchors are allowed at the sidewall locatlons. I understand 5 ft - "Weatherproof�ng _ <br /> , anchors are required at all centerline tie points where the torque test <br /> reading is 275 or less and where the mobile home manufacturer may The bottomboard will be repaired and/or taped. Yes � . Pg. <br /> , requires anchors with 4000 Ib holding capacity. Siding on units is installed to manufacturer's specifications. Yes�, <br /> ' - Installer's initials Fireplace chimney installed so as not to allow intrusion of rain water.�Fe�� <br /> _ _ - ; <br /> -- � A►LL TESTS M ST�E PE FO ED Y A ICENSED INSTALLEFI Mlscellaneous <br /> Installer Name �/��J�]e? ����� Skirting to be installed: Yes No _ <br /> Dryer vent installed outside of skirting.. Yes N/A .✓ <br /> Date Tested � /a r l�s Range downflow vent fnstalled outside of skirting. Yes • N/A_� <br /> Drain lines supported at 4 foot intervals. Yes,�,�_ <br /> Electrical crossovers protected.�fes�_ ' <br /> - Other: - <br /> Electrical <br /> Connect electrical conductors between multi-wide units,but not to the main power - <br /> source. This includes the bonding wire between mult-wide units. Pg.,�� <br /> - Installer verifies all Information given with this permit workshee! <br /> um na .. is accurate and�true based on the <br /> � manufac#urer's(nstallation instruction�and or Rule 15C-1 &2 � <br /> Connect all sewer drain's to an existing sewer tap or septic tank. 'Pg. � <br /> Connect all potable water supply piping to an existing water meter,water tap,or other <br /> Installer Sigrsature Date�/S <br /> independent water supply systems. Pg. <br />� � <br />