Laserfiche WebLink
� FOF2M 6a0A-2004 EnergyGauge(�4.Q � <br /> � � ii nce Checklist I� <br /> � Code Comp a <br /> Residential VVhale Building Performance Methad A - Details <br /> ADDRESS: Z-HILLS,Z-HILLS, FL, PERMIT#: - - <br /> i <br /> 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST <br /> COMPOAtENTS SECTION REQUIREMENTS Ft}R EACH PRAC7lCE GHECK - <br /> E�erior Windows&Doors 606.1.ABC.1.1 Maximum:.3 afm/sq�ft.window area;.5 cfm/sq.ft.doar area. <br /> Exkedor�Adjacent Walls 606.1.ABC.1.2.1 Caulk,gasket,weat�erstrip or seal between:windows/doors&frames,surrounding waR; <br /> foundation&watl sole or sii!piate;joints between eacterior wali panels at comers;utitity <br /> penetrations;between wail panels 8�top/bottam plates;between walls and floor. <br /> EXCE3�TtON:Frame walls where a cantinuaas infilb°ation barrier is insta[led that�eactends <br /> ftom,and is sealed�n,the foundation to the top plate. <br /> Fiaors 606.9.A8C.9.2.2 Penetrationstopenings>1t8"seated nnfess badced by trvss or jaint members. <br /> EXCEPTION:Frame floors where a continuous infiltration barrier is installed that is sealed <br /> , to the perimeter,pe�etrations and seams. <br /> Ceitings 606.1.ABC.1.2.3 Between waiis 8 ceilings;penetrations of ceiling plane of tap ftoor,around shafts,chases, <br /> soffits,chimneys,cabinets sealed to continuous air barrier,gaps in gyp board&top plate; <br /> attic access.EXCEFTION:Frame ceilings where a continuous infiitration barrier is <br /> installed that is seal�ed at the perime#er,at penehations and seams. <br /> Rec�ssed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with r!o penetrations,seaEecl;or Type 2C or non-lC rated,installed inside a <br /> sealed box with 1/2"I clearance&3"fram insulation;ar Type IC rated with<2.0 cim from <br /> cond�tioned space,{esked. <br /> Mu(ti-story Nouses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. <br /> Additional Infiftration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors,dampers;combustian space heaters comply with NFPA, <br /> have combvs#ion a�r. <br /> 6A-22 OTHER PRESCRtPTtVE MEASURES{must be r�tret or exceeded by aEt residences.} <br /> COMPONENTS SECTION REQUIREMENTS I CHECK <br /> Water Heaters 612.1 Compty wi#h efficis�cy requir�mer�ts in Tab1e 612.'l.ABC.3.2.Switab oc cfeady marked ar <br /> breaker(elect�ic)orl cutoff(gas)musk be provided.F,actemal or buiit-in heat trap required. <br /> Swimming Pools&Spas 612.1 Spas&heated pools must have covers(except solar heated).tVon-commercia!poois <br /> must have a pump timec Gas spa&pool heaters must have a minimum thermal <br /> efficiency of 78%. <br /> Shower heads 692.1 Water flow must be resfriafed ta na mare fhan 2.5 gallons per minute at 80 PStG. <br /> Air Distribu#ian Systems 610.1 All ducts,fittings,mi chanical equipment and plenum chambers shall be mechanically <br /> attached,seated,insulated,and instaited in accordance vuith the criteria of Section 610. <br /> Ducts in unconditioned attics:R-6 min.insulation. <br /> NVAC Controls 607.4 Separate readily accessibie manual or automatic thermastat for eaah system. <br /> tnsulation 604.1,fi02.1 Ceilings-Min.R-19.�Cammon walis-Frame R-11 or CBS R-3 both sides. <br /> Comman ceiling&floors R 11. <br /> EnergyGaugeTM' DCA Form 600A-2004 EnergyGaugec�/FIaRES'2004 FLRCSB v4.0 <br />