Laserfiche WebLink
� � FORM 405-10 � <br /> Fforida Code �ampliance Checklist <br /> Fiorida Department of Business and Professional Regulations <br /> Residential Whole Bu'rfding Performar�ce Method <br /> ADDRESS: PERMIT#: <br /> � ��� <br /> MANDA'TORY REQUIREMENTS SUMMARY-See individuat cade sections far futl detaits. <br /> � <br /> COMPONENT SECTION � SUMMARY aF REQUIREMENT(S} : CHECK <br /> i <br /> _.—_.---_.. ......_...�.__...... .. ........--- .–�-.__...._._._._—�.____.....__.._—.___.._—.. _.—...__.—..___�._---_..._.....___.,_.__._.._ <br /> Air leakage � 402.4 ; To be caulked,gasketed, weatherstripped ar atherwise sealed. <br /> i Recessed tighting IC-rated as meefing ASTM E 283.Wiridows and � <br /> ; daars=Q.30 c€misq.ft. Tesfing ar visual inspectian required. Fireptaces: ! <br /> I gaske#ed doars&outdoar combustion air. Mttst campiete envelape � <br /> ` i leakage report ar visually verify 7able 402.4.2. ; <br /> � <br /> Thermostat 8 , 403.1 j At least one thermostat shati be provided for each separate heating and i <br /> cantrois ' caoling system.Where forced-air furnace is primary system, ; <br /> ? programmable tt�errnostat is reqe�ired. Heat pumps with supplernental � <br /> � electric heat must prevent supplementa!heat when compressor can ' <br /> � rneet the load. <br /> ---�•--------�---. .-- ----�---;-- �-- ----.^�._..�_. _.^i.��.... <br /> Duots ; 403.2.2 � A1!duats,air handlers,filter boxes and buifding cavities which farm the i <br /> , primary air cantainment passageways far air distribution systems shall <br /> � be considered duc#s or plenum chambers, shall be constructed and , <br /> : sea#ed in accordance with Section 503.2.7.2 of this code. � <br /> i <br /> ; 4q3.3.3 Suilding frarning cavities sha!!not be used as supply ctucts. , <br /> Water heaters 4fl3.4 i Heat trap required for vertical pipe risers. Compiy with efftciencies in � <br /> ; Table 443.4.3.2. Provide swi#ch or clearfy mar}ced circuit breaker � <br /> ' (electric)or shutaff(gas}.Circulating system pipes insulated to=R-2 ° <br /> � +accessible manual OFF switch. � <br /> ___.._�._• .---_ _ ---.�_...____ ._..._ .�.._�_....�_�... <br /> _..._�..___. <br /> ..Mechanical �..� ? 403.5 i Homes designed to opera#e aE positive pressure or rvi#h mechanica} ; <br /> venti�ation i j ventilation systems shall not exceed the minimum ASHRAE 62 level. + <br /> , ( No make-up air from attics,crawlspaces,garages or aufdoors adjacent ; <br /> ; ! ta poats ar spas. <br /> _ —___� ._._.—__ .__.. ____._.._..��._._—___.._.�__.___.._�_�_—._.._______--------....�..__.._!_._.._._. <br /> Swirnming Pools � 403.9 ! Pool pumps and poal pump motors with a#o#al horsepower(HP}of= 1 ; <br /> &Spas ; HP shal!have the capabifity of aperating at two or more speeds. Spas ; <br /> ; and heated pools must have vapor-reta�dant cover�or a liquid cover or ! <br /> I other means proven to reduce hea#loss except if 70°l0 of heat from ; <br /> �! site-recovered energy.Off/timer swi#ch required. Gas heaters minimum � <br /> ! #herma!e�ciency=78°l0(82°!o after 4/16!'!3}. Heat pump poo!heaters ; <br /> , i minimum COP=4.�. • <br /> Cooling/heating ... ' 443.fi .� _� Sizing calculation performed 8�aitached. Minimum efficiencies per � . _—.._._ <br /> "fables 503.2.3. Equipmen#efficiency veri�cation required. Specia! � <br /> equipment � { o��ion cooling ar lieati�g capacity requires separate system or ; <br /> � i variabte capacity system. E{ectric heat>9 OkW rnus#be divided into two � � <br /> ; i or more stages. � <br /> ._.,_.—..__._.__.._. �--._. ._.....�.-----. ..____. _._...._—......--.--....._._..__�.._------___..—.---.----_...__.__�._�____._�—Y----._._..__. <br /> i <br /> Ceitingslknee walis ' 445.2.1 i R-19 space permitting. <br /> 6/412044 9:20 AM EnergyGauge�tlSA-Fiaf2es2010 SecEion 405.4 9 Comptiant Sofiware Page 5 of 5 <br />