My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
15-16499
Zephyrhills
>
Building Department
>
Permits
>
2015
>
15-16499
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/7/2016 9:41:21 AM
Creation date
3/7/2016 9:41:20 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
15-16499
Building Department - Name
CAMERIO,PAMELA
Address
5238 16TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WEATHER KING PORTABLE BUILDINGS <br /> 760 WESTBROOK ROAD <br /> HICKORY, KY 42051 <br /> GENERAL NOTES: DESIGN CRITERIA. ITEMS BY OTHERS: <br /> 1 STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE WITH 10.WOOD FRAMING SHALL COMPLY WITH THE NATIONAL 1.DESIGN LOADS ARE IN ACCORDANCE WITH THE FOLLOWING ITEMS MAY BE SUPPLIED AND <br /> THE 2014 FLORIDA BUILDING CODE(FBC). FOREST PRODUCTS ASSOCIATION(NFPA)"NATIONAL THE FLORIDA BUILDING CODE,2014. INSTALLED BY OTHERS. THESE ITEMS MAY BE <br /> DESIGN SPECIFICATION FOR WOOD CONSTRUCTION",2012. OCCUPANCY CATEGORY I SUBJECT TO LOCAL JURISDICTION APPROVAL. <br /> 2.ALL MATERIALS AND CONSTRUCTION SHALL BE IN WEATHER KING PORTABLE BUILDINGS IS NOT <br /> ACCORDANCE WITH THE ABOVE CODES ATTHE TIME OF 11.ALL ROOF DECKING IS TO BE%fi"O.S.B. 2.LIVE LOADS: RESPONSIBLE FOR THESE ITEMS. <br /> MANUFACTURE. FLOOR:40 PSF <br /> 12.ALL SIDING IS TO BE TREATED T1-11,LP SMARTSIDE LOFT:10 PSF 1 THE FOUNDATION TIE-DOWN SYSTEM <br /> 3.DRAWINGS SHALL NOT BE SCALED FOR DIMENSIONS. PANEL,OR 29 GA.METAL SIDING. ROOF:20 PSF <br /> 2.RAMPS,STAIRS,AND GENERAL ACCESS <br /> 4.STRUCTURES ARE CLASSIFIED AS"MINOR STORAGE 13.ALL FLOOR JOISTS ARE TO BE PRESSURE TREATED 3.WIND LOADS ARE BASED ON THE FOLLOWING: <br /> FACILITIES"(OCCUPANCY CATEGORY I)AND SHOULD NOT BE SYP#2,OR BETTER. ULTIMATE DESIGN WIND SPEED: 3.ELECTRICAL SERVICE HOOKUP <br /> USED FOR HUMAN HABITATION. (2014 FBC FIGURE 1609C) <br /> 14.ALL WOOD FRAMING IS TO BE TO BE SPF#2 OR BEl7ER, Vult=160 MPH <br /> 5.STRUCTURES ARE DESIGNED FOR LOCATIONS THAT HAVE A UNLESS NOTED OTHERWISE. RISK CATEGORY I <br /> 3 SECOND WIND GUST OF 160 MPH FOR RISK CATEGORY I EXPOSURE CATEGORY C <br /> STRUCTURES PER FIGURE 1609C OF THE 2014 FBC. 15.ALL FLOOR DECKING IS TO BE 5/"TREATED PLYWOOD. INTERNAL PRESSURE COEFFICIENT <br /> UN-TREATED T&G PLYWOOD FLOORING MAY BE USED GCpi=t0.18 <br /> 6.SIDING FASTENERS SHALL NOT BE INSTALLED IN PANEL SIDING WHERE THE BOTTOM OF THE FLOORING IS OVER 18"ABOVE COMPONENTS&CLADDING: <br /> GROOVES IN THE FIELD OF THE PANEL OR WHEN THE SIDING THE GROUND. LOADS SHOWN HAVE NOT BEEN ADJUSTED FOR <br /> GROOVES OCCUR AT CUT EDGES OF THE SIDING PANEL. LOAD COMBINATIONS IN FBC SECTION 1605. <br /> 16.ALL SKIDS ARE TO BE 4x6 PRESSURE TREATED, <br /> 7 STRUCTURES ARE DESIGNED FOR LOCATIONS THAT ARE NOT RATED FOR GROUND CONTACT EFFECTIVE WIND AREA,Ae=10 FT' <br /> IN FLOOD HAZARD AREAS. STRUCTURES SHOULD NOT BE ROOF-ZONE 1= 322,-51.1 PSF <br /> USED IN OTHER LOCATIONS. 17 NAIL IN ACCORDANCE WITH RECOMMENDED WOOD ROOF-ZONE 2= 32.2,-86.9 PSF <br />- FASTENING SCHEDULE PER TABLE 2304.9.1 OF THE ROOF-ZONE 3= 32.2,-131.5 PSF <br /> S.IN ACCORDANCE WITH FBC 1609.1.2,STORAGE SHEDS NOT 2014 FBC. WALLZONE 4=55:8,--60:5 PSF <br /> DESIGNED FOR HUMAN HABITATION WITH A FLOOR AREA WALL-ZONE 5=55.8,-74.7 PSF <br /> OF 720 SQUARE FEET OR LESS ARE NOT REQUIRED TO COMPLY 1g, ALL EXTERIOR NAILS ARE TO BE ZINC COATED. <br /> WITH THE MANDATORY WINDBORNE DEBRIS IMPACT STANDARDS 4.CONSTRUCTION TYPE. V-B <br /> OF THE 2014 FBC. 19.STRUCTURES SHOULD HAVE 30 YEAR RATED FIBERGLASS/ <br /> ASPHALT SHINGLES OR 29 GA METAL ROOF PANELS. <br /> 9. IN ACCORDANCE WITH FBC 1008.1 1,BUILDINGS THAT ARE 400 <br /> SQUARE FEET OR LESS THAT ARE INTENDED FOR USE IN 20.ALL BUILDINGS ARE TO BE ADEQUATELY ANCHORED TO <br /> CONJUNCTION WITH ONE-AND TWO-FAMILY RESIDENCES TO RESIST WIND LOADS. REFER TO THE MASTER <br /> ARE NOT SUBJECT TO THE DOOR HEIGHT AND WIDTH ANCHORING PLANS,SUBMITTED SEPARATELY,FOR <br /> REQUIREMENTS OF THE 2014 FBC. REQUIRED ANCHORING INFORMATION. <br /> ��°°'J�'L�"N°""''°°-- LOFTED BARN--FLORIDA--WIND=160 MPH--F�C 2014 <br /> ``�•�;.��GENS��•',,o <br /> �*,•'• N0.T7209 •;*% PROJECT NO: <br /> : ; * _ SHEET NUMBER <br /> DATE: 06-05-2015 <br /> ��'• STATE <br /> O'•..b OF P. � � oanWN ev KLN � � � <br /> �,.�� �::; ..� � � S 0 LB FL <br /> ' � � CHECKED BY' KLN <br /> ���/IIIIIIIIIII��\��`, ��,{;y,j���� BVB��c7I�$�t:7 REVISION: <br /> `_�_� SCALE:NONE <br />
The URL can be used to link to this page
Your browser does not support the video tag.