Laserfiche WebLink
, Page 3 of 7 <br /> � 8228.2 Fiberglass Side-Hinged 8'-0" Opaque I/S and O/S Single Door <br /> Door Unit <br /> Limits of Use � Certification Agency Certificate <br /> Approved for use in HVHZ: Yes FL8228 R6 C CAC NI006900.02.pdf <br /> Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date <br /> Impact Resistant: Yes 12/31/2020 <br /> Design Pi•essure: +70.0/-70.0 Installation Instructions <br /> Other: Evaluated for use in locations adhering FL8228 R6 II FL0161Dx.pdf <br /> to the Florida Building Code including the Verified By: National Accreditation & <br /> High Velocity Hurricane Zone, and where Management Institute <br /> pressure requirements as determined by ASCE Created by Independent Third Party: <br /> 7, does not exceed the design pressures listed. Evaluation Reports <br /> 3'-0" x 8'-0" max nominal size. Hurricane FL8228 R6_AE_503A.pdf <br /> protective system required in HVHZ, but not Created by Independent Third Party: Yes <br /> required in the Wind Borne Debris Region. See <br /> DWG-MA-FL0161-07 for additional <br /> information. <br /> 8228.3 Fiberglass Side-Hinged 6'-8" Opaque Inswing Single or pouble Door <br /> Door Unit w/or w/o Sidelites <br /> Limits of Use Certification Agency Certificate <br /> A.pprovedl for use in IiVHZ: Yes FL8228 R6 C CAC NI006900.O1.�df <br /> ApprovecR for use outside HVHZ: Yes Quality Assurance Contract Expiration Date <br /> Impact R�sistant: Yes 12/31/2020 <br /> IDesign Pressure: +50.5/-50.5 Installation Instructions <br /> Other: Evaluated for use in locations adhering FL8228 R6 II FL0160Dx.�df <br /> to the Florida Building Code including the Verified By: National Accreditation& <br /> High Velocity Hurricane Zone, and where Management Institute <br /> pressure requirements as determined by ASCE Created by Independent Third Party: <br /> 7, does not exceed the design pressures listed. Evaluation Reports <br /> 12'-0" x 6'-8" max nominal size. Hurricane FL8228 R6 AE 502A.pdf <br /> protective system required in HVHZ, but not Created by Independent Third Aarty: Yes <br /> required in the Wind Borne Debris Region. See <br /> DWG-MA-FL0160-07 for additional <br /> information. � <br /> 8228.4 Fiberglass Side-Hinged 6'-8" Opaque Outswing Single or pouble Door <br /> Door Unit w/or w/o Sidelites <br /> Limits of Use Certification Agency Certificate <br /> Approved for use in HVHZ: Yes , FL8228 R6 C CAC NI006900.Ol.pdf <br /> Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date <br /> Impact Resistant: Yes 12/31/2020 <br /> Design Pressure: +55.0/-50.5 Installation Instructions <br /> Other: Evaluated for use in locations adhering FL8228_R6_II FL0160Dx.pdf <br /> to the Florida Building Code including the Verified By: National Accreditation& <br /> High Velociiy Hurricane Zone, and where Management Institute <br /> pressure requirements as determined by ASCE Created by Independent Third Party: <br /> http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquftCwaMPtp3Tq... 4/1/201`� <br />