Laserfiche WebLink
, Page 6 o.f 7 <br /> . 8228.10 Fiberglass Side-Hinged 8'-0" Glazed Outswing Single or pouble Door <br /> Door Unit w/or w/o Sidelites <br /> Limits of Use Certification Agency Certificate <br /> Approved for use in HVHZ: Yes FL8228 R6 C CAC NI006900.04.pdf <br /> Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date <br /> Impact Resistant: No 12/31/2020 ' <br /> Design Pressure: +43.0/-47.0 Installation Instructions <br /> Other: Evaluated for use in locations adhering FL8228 R6 II FL0163Dx.�df <br /> to the Florida Building Code including the Verified By: National Accreditation & <br /> High Velocity Hurricane Zone, and where Management Institute <br /> pressure requirements as determined by ASCE Created by Independent Third Party: <br /> 7, does not exceed the design pressures listed. Evaluation Reports <br /> 12'-0" x 8'-0" max nominal size. Hurricane FL8228 R6 AE SOlA.pdf <br /> protective system required in HVHZ and the Created by Independent Third Party: Yes <br /> Wind Borne Debris Region. See DWG-MA- <br /> FL0163-07 for additional information. <br /> 8228.11 Fiberglass Side-Hinged 6'-8" Impact Glazed Inswing Single or pouble <br /> Door Unit Door w/or w/o Sidelites <br /> Limits of Use Certification Agency Certificate <br /> Approved for use in HVHZ: No FL8228 R6 C CAC NI006900.OS.pdf <br /> Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date <br /> Impact 12esistant: Yes 12/31/2020 <br /> Design Pressure: +52.0/-52.0 Installation Instructions <br /> �ther: Evaluated for use in locations adhering FL8228 R6 II FL0162Dx.pdf <br /> to the Florida Building Code not including the Verified By: National Accreditation & <br /> High Velocity Hurricane Zone, and where Management Institute <br /> pressure requirements as determined by ASCE Created by Independent Third Party: <br /> 7 do not exceed the design pressures listed. Evaluation Reports <br /> 12'-0" x 6'-8" max nominal size. See DWG- FL8228 R6 AE 502A.pdf <br /> MA-FL0162-07 for additional information. Created by Independent Third Party: Yes <br /> 8228,12 Fiberglass Side-Hinged 6'-8" Impact Glazed Outswing Single or ', <br /> Door Unit Double Door w/or w/o Sidelites I <br /> Limits of TJse Certification Agency Certificate <br /> Approved for use in HVHZ: No FL8228 R6 C CAC NI006900.OS.pdf <br /> Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date <br /> Impact Resistant: Yes 12/31/2020 <br /> Design Pressure: +55.0/-55.0 Installation Instructions <br /> Other: Evaluated for use in locations adhering FL8228 R6 II FL0162Dx.pdf <br /> to the Florida Building Code not including the Verified By: National Accreditation & <br /> High Velocity Hurricane Zone, and where Management Institute <br /> pressure requirements as determined by ASCE Created by Independent Third Party: <br /> 7 do not exceed the design pressures listed. Evaluation Reports <br /> 1?_'-0" x 6'-8" max nominal size. See DWG- FL8228 R6 AE 502A.�df <br /> MA-FL0162-07 for additional information. Created by Independent Third Party: Yes <br /> http://www,floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquftCwaMPtp3 Tq... 4/1/2015 <br />