My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
15-16339
Zephyrhills
>
Building Department
>
Permits
>
2015
>
15-16339
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/10/2016 10:10:11 AM
Creation date
3/10/2016 10:10:10 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
15-16339
Building Department - Name
HUDGINS,DREW
Address
38453 5TH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
.� -, . <br /> �]�Smo�Ce Detector Specifications <br /> - , R .� �., _-_ . . � ��-. <br /> ;;'��. �;�;:�' �,. <br /> _ . �t�.�.�.�=•� - <br /> Smoke detector shall pe a System Sensor i3 Series model number ,listed to Underwriters Laboratories UL 268 for Fre Protection Signaling Systems.The <br /> detector shall be a photoelectric type(Model 2W-B,4W-B)or a combination photoelectridthermal(Model 2WT-B,4WT-e)with thermal sensor rated at 135°F <br /> (572°�.The detec�or'shall include a mounting base for mounting to 3Yz-inch and 4-inch octagonal,single-gang,and 4inch square back boxes with a plaster <br /> ring,or direct mount to the ceiling using drywall anchors.Wiring connections shall be made by means of5EM5 screws.The detector shall allow pre-wiring ofthe <br /> base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of25 percent-per-foot nominal as measured in the UL smoke boxThe <br /> detector shall be capable of automatically adjusting its serSsitivity by means of drift compensafion and smoothing algorithms.The d"etector shali provide dual- <br /> color LED indication that blinks to indicate power up,norn'mal standby,out of sensitivity,alarm,and freeze trouble(Model 2WT-B,41NT-B)conditions.When used <br /> in conjunction wiih the 2W-MOD2 module,2-wire model5 shall include a maintenance signal to indicate the need for maintenance at the alarm control panei <br /> and shall provide a loop testing capability to verify the circLit without testing each detector inclividually. <br /> - �:, �°��"e�vp�.+y:,—�c��€�.r..�r�e,,. <br /> vC. .,SII.M„__a'et"��~. n i y�' �� <br /> OperatingVoltage • Nominal: 12/24Vnon-polarized <br /> Minimum: 85 V <br /> Maximum:35 V <br /> Maximum Ripple Voltage 30°/a peakto peak of applied voltage <br /> Standby Current - 2-wire:50 NA maximum average;4-wire:50 NA maximum average <br /> Maximum Alarm Current 2-wire:130 mA limited by control panel;4wire:20 mA @12 V,23 mA @ 24 V <br /> Pealc Standby Current 2-wire:100 NA;4wire:n/a <br /> Alarm Contact Ratirjgs 2-wire:n/a;4-wire:OS A@ 30V ACIDC <br /> ,�,• .. :-:;..�::fi�.: -.,,-- �-r-; <br /> - - . __ ,`�� . _ yaa�s;;.�44.a.__✓��,3��"< <br /> Dimensions(including base) 53 inches(127 mm)diameter;2.0 inches(51 mm)height � <br /> Weight 63 oz(178 g) � <br /> OperatingTemperature Range 2W-B and 4W-B:32°F to 120°F(0°Cto 49°C);2WT-B and 4WT-B:32°F to 100°F(0°C to 37.8°C) <br /> Operating Humidity Range Oto 95°.5 RH non-condensing • <br /> Thermal Sensor 135°F(572°�fixed � <br /> FreezeTrouble � 2WT-B and 41NT B only 41°F(5°Q <br />� Sensitivity 25°h/ft nominal - , <br /> InputTerminals j 14to22AWG <br /> Mounting " 3�/z-inch octagonal back box � � <br /> 4inch octagonal back box <br /> Single-gang back box - <br /> 4inch square back box with a plaster ring <br /> Direct mount to ceiling <br /> 0 � '+�'"- es ' _ °P 'sl __ _' :Y�:�'p'�(�:a.r '_��%+'.�� <br /> 4 <br /> • _ ' _ _ _ _ __ _.___'"_`__�.�'�S'GR6�_ _' ' <br /> LED Mode Green LED Red LED Condition i Duration <br /> Power up Blink every 10 seconds Blfnk every 10 seconds Initial LED status indication 80 seconds <br /> Normal(standby) � Blinkevery5seconds off <br /> Outofsensitivity off Blinkeyery5seconds <br /> Freeze trouble ° off Blink every 10 seconds <br /> Alarm , off Solid � - <br /> Ordering Information <br /> �. - - - ;::'.�,;:� :::,;��z5�� �.�.�; <br /> - . �� �4�..::�._:�.a.;.'�a�:'�ti%��ua.:�s <br /> 2W-B i No 2-wire 130 mA max.limited by control panel,� ' <br /> 2WT-B � Yes 2-wire 130 mA max limited by control panel. <br />' 4W-B No 4wire 20 mA @ 12 V,23 mA @ 24V <br /> 4WT-B :� Yes 4wi re 20 mA @ 12 V,23 mA @ 24 V <br /> Accessories , <br /> 2W-MOD2 � 2-wire loop test/maintenance module RT Removal/replacement`,tool <br /> SENS-RDR � Sensitivity reader A77-A62 Retrofit adapter brackec 6.6 inch(16.76 cm)diameter <br /> ��.°-� �"' �����`� 3825 Ohio Avenue•St.Charles,IL 60174 ��R 020095ys[em Sensw. <br /> ��� ������n spedfxatlauabjectmdwngewithouttroticeYVtrystemsensocmnfor <br /> Phone:800-SENSOR2•Fax:630377-6495 �re11P���^�°�^atlon,Indud�ngthelatestwsimo(thlsdara�eet. <br /> A05-031&007•6/09•P2169 <br /> J <br />
The URL can be used to link to this page
Your browser does not support the video tag.