GENERAL NOTES AR�A FOR APPROVAL S7AMP6
<br /> I. THIS STRUGTURE WA5 DESIGNED IN IN AGGORDANGE WITH THE 2010 FLORIDA BUILDING GODE,BUILDING(F.B.GJ
<br /> 2. ALL MATERIALS AND LABOR SHALL BE IN AGGORDANGE WI7H THE ABOVE GODE AND ALL OTHER APPLIGABLE LOGAL GODES AT THE TIME OF
<br /> MANUFAGTURE. ,
<br /> 3. WRITTEN DIMEN510N5 SNALL TAKE PREGEDENGE OVER SGALED DIMENSIONS. '
<br /> 4. 7HE FOUNDATION PLAN IS A SEPARATE 5ET OF PLANS FOR APPROVAL BY.LOGAL MUNIGIPALITIES.
<br /> 5. EXTERIOR DIMENSIONS GAN VARY BETWEEN LIMITS SHOWN AT 2'O.G.BUT MEMBER SPAGIN6 SHALL NOT EXGEED LIMITS AS INDIGATED,
<br /> � 6. ALL THE FoLLOWING LUMBER 5HALL BE PRE55URE 7REATED IN AGGORDANGE WITH AWPA U5E GATEGORY UG4B(GROUND GONTAGT,HEAVY DUTY)�SKIDS
<br /> �. 7. ALL THE FOLLOWING LUMBER SHALL BE PRESSURE TREATED IN AGGORDANGE WITH AWPA U5E GATEGORY UG3B(EXTEi210R ABOVE GROUND,UNGOATED OR
<br /> � POOR WATER RUNOFF)� FLOOR JOISTS,PLYWOOD FLOOR DEGKING,AND EXTERIOR RATED WOOD 57RUGTURAL PANEL 51DING. � 2y �L yZ6�a/z
<br /> � 8. ALL FA57ENER5 AND GONNEGTORS IN GONTAGT WITH PRE55URE TREATED WOOD SHALL BE HOT DIPPED GALVANIZED(GI85)OR STAINLESS S7EEL, note_ pqepo,
<br /> 9. ALL WINDOWS WI7HIN 24'OF DOOR5,AND ALL GLA55 IN DOORS SHALL BE SAFE7Y,TEMPERED,OR AGRYLIG PLASTIG SHEET. qpp,�,. py______��a���,yl� � +
<br /> � 10. FOR ROOFS WITH ASPHALT SHINGLES AND A SLOPE HE7WEEN 2 TO I2 AND 4 TO 12 SHALL HAVE A DOUBLE UNDERLAYMENT APPLIGATION AS REQUIRED IN Rtcitard4BulmcR �
<br /> � AGGORDANGE WITH SEGTION I501.2.8 OF THE 20i0 F.B,G.
<br /> II. UNDERLAYMENT SHALL GONFORM WITH SEGTION 1501.2.3 OF THE 2010 F.B.G, nfaualF Rulldl�plom Ii�nmincr Fl�rldo CaiAQcat�°,y;.•^�
<br /> as 12. ASPHALT SHINGLES SHALL GONFORM WITH SEGTION I5o"1.2.5 OF THE 2010 F.B.G.ATrAGHMEN7 OF ASPHALT SHINGLES SHALL GONFORM WITH 1507,2,7 OF
<br /> THE 2010 F.B.G.
<br /> � 13. FASTENER5 FOR ASPHALT 5HIN6LE5 SHALL GONFORM TO SEGTION 1507.2.6 OF THE 2010 F.B.G.
<br /> 14. TIE-DOWNS SHALL MEET THE REQUIREMENTS oF ALL APPLIGABLE GODES.
<br /> � I5. THESE PLANS NAVE NOT BEEN DE516NED FOR HVHZ REQUIREMENTS A5 5ET FORTH IN THE 2010 F.B.G OR FOR USE AS A GOMMERGIAL BUILDING.
<br /> 16. THE GONTRAGTOR SHALL BE RE5PON51BLE FOR VERIFYING ALL EXISTIN6 GONDITIONS.
<br /> � I'i. THE GONTRAGTOR SHALL BE RE5PONSIBLE FOR DELIVERY AND PLAGEMENT OF LAWN STORAGE UNIT TO INSURE THE INTEGRITY OF THE BUILDING AND 1T5
<br /> 9 GOMPONENT PARTS.
<br /> � 18. No FIELD REVISIoN5 TO ANY STRUGTURAL GOMPONENTS OR DEVIATIONS FROM THESE DRAWINGS SHALL BE MADE.
<br /> � 19. THE OWNER AND THE GONTRAGTOR SHALL HOLD HARMLE55 THE ENGINEER FROM AND AGAINST ALL LIABILITY GLAIMS,DAMAGES,L055E5 AND EXPEN5E5
<br /> � INGLUDING LEGAL FEES ARISING OUT OF OR RESULTING FROM ERRORS OR OMI5510N5!N THE PERFORMANGE OF THE WORK BY THE GON7RAGTOR.
<br /> � 20.SEG710N5 AND DE7AIL5 ON THE DRAWINGS ARE INTENDED TO BE TYPIGAL AND SHALL APPLY AT ALL SIMILAR LOGATIONS,UNLE55 OTHER SEGTIONS AND
<br /> DETAILS ARE SPEGIFIGALLY REFERENGED. NDI
<br /> � 21. REFER TO 5UPPLIED FASTENING SGHEDULE FOR FASTENING BASED ON GONNEGTION ANp LOGATION OF MEMBERS A5 PER 2010 pLORIDA BUILDING GODE ��qppROVEDt��
<br /> � TABLE 2304.9.1 UNLE55 NOTED OTHERWISE.
<br /> 22.BUILDINGS HAVE BEEN DESI6NED FOR LP SMARTSIDE PREGISION PANEL SIDING,LP SMARTSIDE PREGISION LAP SIDING 5HALL NOT BE USED. DOCUM�1
<br /> � 23.FASTENERS IN LP SMARTSIDE PREGISION PANEL SIDING MUST NOT BE INSTALLED IN PANEL SIDING GROOVES IN THE FIELD OF 7HE PANEL SIDING OR WHEN
<br /> THE PANEL SIDING GROOVES OGGUR AT GUT EDGES OF THE PANEL 51DING.
<br /> � 24.REFER TO THE IGG-ES EVALUATION REPORT ESR-1301 FOR ADDITIONAL DATA AND SPEGIFIGATIONS OF LP SMART5IDE PREGISION PANEL 51DING.
<br /> 25,MAX OPENINGS WIDTHS MUST GOMPLY WITH DESIGN RATI05 AS PER AN51/AF4PA 5DPW5-2008,BUILDINGS HAVE BEEN DE5IGNED TO HAVE OPENIN65 IN
<br /> b ENDWALLS WITH MAX WIDTHS EQUAL TO TH05E(N THE ENDWALL SHEAR WALL GHART.
<br /> 26.A5 PER SEGTION 553.77(10)(h),FLORIDA STATUTES,STORAGE SHEDS THAT ARE NOT DE5IGNED FOR HUMAN NABI7ATION AND THAT HAVE A FLOOR AREA
<br /> � OF 720 SQUARE FEET OR LE55 ARE NOT REQUI�tED TO GOMPLY WITH THE MANDATORY WIND-BORNE-DEBRIS-IMPAGT STANDARDS OF THE FLORIDA
<br /> � BUILDING GODE.IN ADDITION,SUGH BUILDIN65 THAT ARE 400 SQUARE FEE7 OR LE55 AND THAT ARE INTENDED FOR USE IN GONJUNGTION WITH
<br /> ONE-AND-TWO-FAMILY RESIDENGES ARE NOT SUBJEGT TO THE DOOR HEIGHT AND WIDTH REQUIF2EMENTS OF THE FLORIDA BUILDING GODE.
<br /> � 27.BUILDINGS HAVE BEEN DE5IGNED TO HAVE ANGHORS DIREGTLY ATTAGHED TO ALL FOUR GORNERS OF THE BUILDING TO RE515T TENSION FORGES FROM
<br /> LATERAL WIND LOAD5,THIS DESIGN GONSIDERATION MUST BE MADE BY INSTALLER WHEN ATTAGHING'ANGHORING SYSTEM TO BUILDING.
<br /> 28.UNLE55 NOTED OTHERWISE,ATTAGH ALL MANUFAGTURED PRODUGTS IN AGGORDANGE WITH'MANUFAGTURERS SPEGIFIGA710N5. �'"'t Dl9ltallysigned
<br /> � `i J Dix nomasA \��\\5����I,{/_/��//
<br /> � TH�BU�ILDIN6 15 NOT DE5IGNED FOR M1MAN 51TE INSTALLED ITEMS DN:cn=7homas.���O�P��°E�F o�.j��i
<br /> � HABIiATION AND DOES NOT HAVE RUNNING WATER N07E 7NAT THIS LIST DoES NOT NEGE55ARILY LIMI7 THE ITEMS OF YVORK AND Dlxon,o=Dixo�:�� �y=
<br /> MA7ERIALS THAT MAY BE REGVIRED FOR A GoMPLETE INSTALLATION. ALL No.34222
<br /> OR SANITATION SERVIGES.THIS BUILDING 15 Englneering In�
<br /> SITE RELATED IiEMS ARE SUB,IEGT TO LOGAL,11RISDIGTIONAL APPROVAI.. * *_
<br /> � DESIGNED AS A UTILITY SHED 70 570RE LAVAI ou,, - _
<br /> EQUIPMENT 5ULFI AS NWEEL BARROhtS, emall.=tom@ �p
<br /> GARDENING�LIES,FLOWER POTS,AND I.THE GOMPI.ETE FOUNDAiION SUPPORT AND TIE-DONW 5Y57EM. � STATE OF �
<br /> 2.RAMPS,STAIRS,AND GEN62AL AGGE55 TO THE BUILDING IF NEGE55ARY. nenglnepiingli�c�� ��\
<br /> �0 GARDBOARD BOXFS WITH VARIOVS SMALL ITEMS. g,��,qND DONWSPOUTS ON ALL BUILDINCfi WITH EAVES�LE55 7HAN om,r-US ✓j/'�. �pR10^ G����
<br /> � 6 INGHES HORIZONTAL PROJEGTION EXGEPi FOR GABLE END RAKES. ' Date:2012.04.18 //���p f����\
<br /> :5 , - 09:48:04-04'OD' ��//��1111111`�\�� �y BY DATE DESGRIPTION
<br /> 2
<br /> � THESE PLANS WERE DESIGNED IN AGGORDANGE WITH THE 2010 FLORIDA BUILDING GODE,BUILDING FOR A THRE�SEGOND GUST OF I60 MPH.
<br /> � 7HOM�4� �4. I�IXON, P.E. UJEATHER KINCs vnre� oaioans SHEET
<br /> � LOFIED BARN WOOD SNED PLAN DfL1YUJ BY� GEB
<br /> s ALp 30637 FiSu 19034 KSx�IIQB pIXON FJ4GINEERING,ING. 'Ibp y�,lBappK Rpqp �-�
<br /> 5LU 27592 NGM 035qB5 GAu 034971 STR11G1LRAL ENG�IY AND WSFEGTIq4-(,pA 6145 HIGY.ORY.KY 4Z051 ��D�� �
<br /> & WJU'071936 TXu 104953 MDU 40qOr 10410 MNN SiREET ebb-q77-b440
<br /> PAU 074009 VAU 045593 THON0T05iL5`A,R 33592 SGAL6 AS NOTED
<br /> '� TNw 112761 fLU 94222 VOIGE�818-0B2-9H85 FAX�bi3q82-2306 NOTE6 WA.NO� 526-012 3 OF 14