FORMS <br /> , TABLE402A <br /> BUILDiNG COPAPONEI�T PEAFOABAANCE CRITERIA INSTALLED VALUES: _ <br /> U-Factor<0.65 U-Factor= <br /> Wmdows(see Note 2): SHGC=0.30 SHGC= <br /> 96 0l CFA<=20% g6 01 CFA= <br /> S li hLS U-Factor<0.75 <br /> Doors:Exteriordoor U-Factor U-Factor<0.65 U-Factor= <br /> Floors: Slab-ont,�rade No requirement R-Value= <br /> pyer�mcondtioned see Note 3 A-13 <br /> Walls—EM.and A�.(see Note 3): <br /> Frame R-13 R-Value= <br /> Mass (see Note 3) <br /> Irderior ot wall: R-7_8 R-Value= <br /> Exterior of wall: R-6 A-Value= <br /> Ceilfn s see Notes 3&4 R�0 R-Value= T���� <br /> Reflectance , 025 Reflectans:e T A��� <br /> YeslNo <br /> Air disVibution system(see Note 4) <br /> DucNroAc&air handling unit Loratinn: <br /> Uncorxfi6oned space Not allowed Tes[report <br /> Attached7 <br /> Condrtioned space YeslNo <br /> Duct R-value R-vaiue?6 R-Value= <br /> Air leakage�n on<_0_03 Q�_ <br /> Air con '' see Nnte SEER=�3.0 SEER= <br /> Heating system <br /> Heat pump(see Note 5) Cooling: SEER=13.0 SEER= <br /> Heating: HSPF=7_7 HSPF= <br /> Gas fumace AFUE 78% AFUE= <br /> Oil tumace AFUE 78% Afl1E_ <br /> ElecVic res'stance:Not altowed(see Note 5) <br /> Water heatimJ system(storage lype) <br /> pecUic(see Nole 6): 40 gaL•EF=0.92 Gallons= <br /> I 50 gal:EF=O_9D EF= ^ <br /> Gas fired(see Note 7�: q0 gal:EF=0.59 Gallons= <br /> Othe��descn.be�. 50 gal:EF=0.58 EF= <br /> (1)Each componerrt present in ihe As Proposed home must meet or exceed each of the applicable perfortnance criferia in orderto compiy with this code using this method; <br /> othervvise Section 4D5 compfiance must be used. <br /> (2)�ndows and doors qual'rfying as glazedienestratian areas must comptywith both the maximum U-Fac[orand the ma�dmum SHGC(solarHeat Gain CoeHicient)criteria <br /> and have a ma�dmum total window area equal to or less than 20%ot the conditioned iloor area(CFA);othervvise Section 405 must be used tor compliance. <br /> Exceptinn: Additions of 60D square feet(56 rr�}or less may have a maximum glass to CFA of 50 percent <br /> (3)R-values are tor insulation material only as app6ed in accordance with manufacturers'iostaliation instructions.For mass walis,the interiof ot walP'requirement must be <br /> met except'rf at least 50°k of the R-6 insulation required for the"exterior oi wall°is installed exterior of,or integral to,the wall. <br /> (4)Du�ts&AHU instalied substantially leak free per Section 40322.1.Test by Class 1 BERS rater required. <br /> Exception:Ducts installed onto an exisGng air disiribution system as part of an addition or renovation;duct must be R-6 installed per Sec.503.272. <br /> (5)For all converttional unils wiih capacities greater than 30,OD0 Btu/hr. For other types of equipment,see Tables 503.23(1-8). <br /> Exception:The prohb"dion on efechic resistance heat does not apply to add�ions,renovations and new heating systems installed in existing buildings. <br /> (6)For other electric storage wlumes,minimum EF=0.97-(0.00132 x volume). <br /> (7)For other nawral gas storage wlumes,minimum EF=O.fi7-(0.0019 x wlume). <br /> TABLE 4026 MANDATORY REQUTAEMENTS <br /> C�PONENTS ' SECTION RE�UIHEMENTS CHECK <br /> To be cauthed,gasketed,wealhersUippetl or othenvi�sealed.Aecessed tighting IGrated as rt�eating ASTM E <br /> i Air leakage 402.4 283.Wmdows and doors=0.30 dMsq.ft Testing or visual inspection required.Fuepiarxs:gasketed doors& I <br /> outdoor oombustion air. � <br /> Ceilingslknee walfs 405.21 R-19 space pemtit6ng. I <br /> Programmabte ihermostat 403.�.1 Where forad-air fumace is primazy sys[em.programmable themwshaf is required. I <br /> Air distributlon system 4032 Ducxs in attics or on rools insutaled to R-8;other ducts R�.Ducis tested to Oq=0.03 by a Ciass 1 BERS rater. <br /> Heat trap required for verticai pipe risers.Compty with efficiencies in Table 403.4.32.Provide svitch or dearly <br />� Water heaters 403.4 marked circuit breaker(elecVic)or shutoft (gas).Circulating system pipes insulated to=R-2+aa�ssible manual <br /> OFF switch. <br /> Spas and fieated pools musl have vapor-retatdant cavers ar a tiquid cover ar other means proven to reduce heat <br /> Swimming pool S spas 403.9 bss except it 70°h ai heat hom site-recovered energy.OtUtimer switch required.Gas heaters mirdmum thermal <br /> effiae =78% B2%afterM16H3.Heat um oolheatersminimumCOP=4.0. <br /> Smng calculation perfortned&attached.Minimum etficiencles per Tabies 50323.Equipmerrt efficiertcy verification <br /> Cooling/heating equipment 403.6 required.Special oxaston cooling or hea6ng capaciry requires separate system or variabie capacity system. <br /> Electric heai>�OkW must be divided iMO two or more sta es. <br /> Lighting equipmer�t 404_t At least 50%of pertnane�'ustalled IigMing fadures stpll be hi9h-efFuacy 1amAs. <br /> 2010 FLORIDA BUILDING CODE—E{1l5RGY COMSEFiVRTION C•� <br />