My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
15-16120
Zephyrhills
>
Building Department
>
Permits
>
2015
>
15-16120
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2016 1:49:31 PM
Creation date
3/21/2016 1:49:30 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
15-16120
Building Department - Name
THOMAS,VARGHESE & KURIAN JAYAMOL
Address
5741 9TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�� <br /> � <br /> Force Enb neering&Testing Inc. <br /> 19530 Ramblewood Drive <br /> Humble,TX 77338 <br /> Compliance Statement: The product as described in this report has demonstrated compliance with the <br /> Florida Building Code 2010,Sections 1504.3.2,1504.7. <br /> Produtt Destription: PBR Roof Panel, 26 Ga. Steel, 36" Coverage, through fastened roof panel over <br /> 1x4 wood purlins over Min.15/32"Plywood decking.Non-Structural Application. <br /> Panel Material/StBndard5: Material: Minimum 26 Ga.Steel,ASTM A792 or ASTM A653 G90 conforming to <br /> Florida Building Code 2010 Section 1507.4.3. Paint finish optional. <br /> Yield Strength: Min.80.0 ksi <br /> Corrosion Resistance:Panel Material shall comply with Florida Building Code <br /> 2010,Section 1507.4.3. <br /> Panel Dimension(S): Thickness: 0.0185"min. <br /> Width: 36"Coverage <br /> Rib Height: 1%"tall rib at 12"O.C. <br /> Panel Rollformer: MRS,Metal Rollformer Systems <br /> Panel Fastener: #9-15 x 1-1/2" Woodgrip with sealing washing, %-14 x 7/8" HWH with sealing <br /> washer at 24"O.C.at the panel side laps or approved equals <br /> %"minimum penetration through plywood <br /> Corrosion Resistance:Per Florida Building Code 2010,Section 1506.6,1507.4.4 <br /> Substrate DesCription: Min.lx4 No.2 SYP wood purlins over min.15/32"thick,APA Rated plywood over <br /> supports at maximum 24"O.C. The ix4 wood purlins shall be fastened to the <br /> plywood with minimum 8x2%"Ring Shank Nails at 4"O.C. Design of 1x4 wood <br /> purlins,plywood and plywood supports are outside the scope of this evaluation. <br /> Must be designed in accordance w/Florida Building Code 2010. <br /> Design Uplift Pressures: <br /> Table"A" <br /> Maximum Total Uplift Design Pressure: 94.25 psf 151.75 psf <br /> Fastener Pattern: 12"-12"-12" 7"-5"-7"-5"-7" <br /> Fastener Spacing: 24"O.C. 12"O.C. <br /> *Design Pressure includes a Safety Factor=2.0. <br /> ,,,��{l{1�/1JI��I <br /> ���Q�F:���E� ���� ���i <br /> ��Q:'�, � �� N S F �'c`��� <br /> � ,�, •;�` <br /> � � . No.444 ( i <br /> - � <br /> — � t�t���.-�� <br /> r (�%/��-f ' �/ <br /> � <br /> ��• sTa�aF ;�� <br /> .?'. t� • <br /> '�,�,�. �L p R I 1�A �'�•• <br /> 5���. �,�•. .•�,�,,. <br /> MasAr�',n ��t s%' • .. . •-�V,�� <br /> J'���d+I 1 14 ti�,`` <br /> FL#11651.20 Rl February 22, 2012 <br />
The URL can be used to link to this page
Your browser does not support the video tag.