My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
15-16121
Zephyrhills
>
Building Department
>
Permits
>
2015
>
15-16121
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2016 1:50:10 PM
Creation date
3/21/2016 1:50:09 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
15-16121
Building Department - Name
THOMAS,VARGHESE & KURIAN,JAYAMOL
Address
38440 13TH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> Force En�neering&Testing Inc. <br /> 19530 Ramblewood Drive <br /> Humble,TX 77338 <br /> Compliance Statement: The product as described in this report has demonstrated compliance with the <br /> Florida Building Code 2010,Sections 1504.3.2,1504.7. <br /> ProduCt DesCription: PBR Roof Panel, 26 Ga. Steel, 36" Coverage, through fastened roof panel over <br /> 1x4 wood purlins over Min.15/32"Piywood decking.Non-Structural Application. <br /> Panel Material/Standards: Material: Minimum 26 Ga.Steel,ASTM A792 or ASTM A653 G90 conforming to <br /> Florida Building Code 2010 Section 1507.4.3. Paint finish optional. <br /> Yield Strength: Min.80.0 ksi <br /> Corrosion Resistance:Panel Material shall comply with Florida Building Code <br /> 2010,Section 1507.4.3. <br /> Panel Dimen5i0n(5): Thickness: 0.0185"min. <br /> Width: 36"Coverage <br /> Rib Height: 1'/<"tall rib at 12"O.C. <br /> Panel Rollformer: MRS,Metal Rollformer Systems <br /> Panel Fastenee: #9-15 x 1-1/2" Woodgrip with sealing washing, '/<-14 x 7/8" HWH with sealing <br /> washer at 24"O.C.at the panel side laps or approved equals <br /> %"minimum penetration through plywood <br /> Corrosion Resistance:Per Florida Building Code 2010,Section 1506.6,1507.4.4 <br /> Substrate DesCripti0n: Min.lx4 No.2 SYP wood purlins over min.15/32"thick,APA Rated plywood over <br /> supports at maximum 24"O.C. The lx4 wood purlins shall be fastened to the <br /> plywood with minimum 8x2�" Ring Shank Nails at 4"O.C. Design of lx4 wood <br /> purlins,plywood and plywood supports are outside the scope of this evaluation. <br /> Must be designed in accordance w/Florida Building Code 2010. <br /> Design Uplift Pressures: <br /> Table"A" <br /> Maximum Total Uplift Design Pressure: 94.25 psf 151.75 psf <br /> Fastener Pattern: 12"-12"-12" 7"-5"-7"-5"-7" <br /> Fastener Spacing: 24"O.C. 12"O.C. <br /> "Design Pressure includes a Safety Factor=2.0. � <br /> ,'���{f{111f11�,I <br /> ,��� �N C E, E?� �4,0 �i�i <br /> � Q`�1. 1 �� N S F �'c���i <br /> �,<k:.' .�n � <br /> � : No.444� �-�1���-'�/'� � <br /> � � �, .� *'" .*— <br /> `•�'1����TATE OF :a`/ <br /> r?'. t� •. <br /> '.°� FL 4 R I�4', �,�'�,. <br /> sm�ormae. �� E'S:• • '�• v� <br /> w�m ��r���a�������NG`,� <br /> FL#11651.20 Rl February 22, 2012 <br />
The URL can be used to link to this page
Your browser does not support the video tag.