Laserfiche WebLink
. P�ige 3 of 5 <br /> . Other: Evaluated for use in locations adhering FL4904 R6 II FL0129.pdf <br /> ta the Florida Building Code including the Verified By: National Accreditation & <br /> High Velocity Hunicane Zone, and where Management Institute <br /> p��essure requirements as determined by ASCE Created by Independent Third Party: <br /> 7; Minimum Design Loads for Buildings and Evaluation Reports <br /> Other Structures, does not exceed the design FL4904 R6 AE 503A.pdf <br /> pressures listed. 3'-0" x 8'-0" max nominal size. Created by Independent Third Party: Yes <br /> VVhen large missile impact resistance is <br /> required, hurricane protective system is NOT <br /> required. See DWG-MA-FL0129-OS for details. <br /> 4904.3 Wood-edge Steel Side- 6'-8" Opaque I/S and O/S Door w/ or w/o <br /> Hinged Door Units Sidelites <br /> Limits of Use Certification Agency Certificate <br /> A�pproved for use in HVHZ: Yes FL4904 R6 C CAC NI0061 lO.Ol.pdf <br /> ��pproved for use outside HVHZ: Yes Quality Assurance Contract Expiration :Date <br /> Impact ktesistant: Yes 12/31/2020 <br /> Tlesign Pressure: +55.0/-55.0 Installation Instructions <br /> Other: Evaluated for use in locations adhering FL4904 R6 II FL0128.pdf <br /> to the Florida Building Code including the Verified By: National Accreditation & , <br /> High Velocity Hurricane Zone, and where Management Institute <br /> pr�essure requirements as determined by ASCE Created by Independent Third Party: <br /> 7, Minimum Design Loads for Buildings and Evaluation Reports <br /> Other Structures, does not exceed the design FL4904 R6 AE 502A.pdf <br /> pressures listed. 12'-0" x 6'-8" max nominal Created by Independent Third Party: Yes <br /> size. When large missile impact resistance is <br /> required, hurricane protective system is NOT <br /> required on opaque panels, but is required on <br /> glazed panels. See DWG-MA-FL0128-05. <br /> 4904.4 Wood-edge Steel Side- 8'-0" Opaque I/S Door w/ or w/o Sidelites <br /> Hinged Door Units <br /> Limits of Use Certification Agency Certificate <br /> �pproved for use in HVHZ: Yes FL4904 R6 C CAC NI006110.02.pdf <br /> A�pproved for use outside HVHZ: Yes Quality Assurance Contract Expiration ]Date <br /> Impact Resistant: Yes 12/31/2020 <br /> �lesign Pressure: +45.0/-50.0 Installation Instructions <br /> Other: Evaluated for use in locations adhering FL4904 R6 II FL0129.pdf <br /> to the Florida Building Code including the Verified By: National Accreditation& <br /> High Velocity Hurricane Zone, and where Management Institute ', <br /> pressure requirements as determined by ASCE Created by Independent Third Party: ' <br /> 7, Minimum Design Loads for Buildings and Evaluation Reports <br /> Other Structures, does not exceed the design FL4904 R6 AE SOlA.pdf <br /> pressures listed. 12'-0" x 8'-0" max nominal Created by Independent Third Party: Yes ' <br /> size. When large missile impact resistance is <br /> required, hurricane protective system is NOT <br /> required on opaque panels, but is required on <br /> glazed panels. See DWG-MA-FL0129-05. <br /> http://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDqteluIwHNbblSc... 2/21/2015 <br />