My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
15-16178
Zephyrhills
>
Building Department
>
Permits
>
2015
>
15-16178
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2016 2:41:18 PM
Creation date
3/21/2016 2:41:18 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
15-16178
Building Department - Name
JOHNSON FAMILY LIV TRUST
Address
38817 10TH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
7 `v <br /> O <br /> Force Engineering&Testing Inc. <br /> 1953012amblewood Drive <br /> Humble,TX 77338 <br /> Code Compliance: The product described herein has demonstrated compliance with <br /> The Florida Building Code 2010,Section 1504.3.2,1504.7. <br /> Evaluation Report Scope: The product evaluation is limited to compliance with the structurai wind load <br /> requirements of the Florida Building Code 2010,as relates to Rule 9N-3. <br /> Performance Standards: The product described herein has demonstrated compliance with: <br /> ■ UL 580-06-Test for Uplift Resistance of Roof Assemblies <br /> ■ UL 1897-04-Uplift Test for Roof Covering Systems <br /> ■ FM 4471,Section 5.4-Foot Traffic Resistance Test <br /> Reference Data: 1. U L 580-94/1897-98 Uplift Test <br /> Force Engineering&Testing,Inc.(FBC Organization#TST-5328) <br /> Report No.117-00407T-09,Dated 11/16/09 <br /> 2. FM 4471-95,Section 5.4 Foot Traffic Resistance Test <br /> Force Engineering&Testing,Inc.(FBC Organization#TST-5328) <br /> Report No.117-0238T-09E,Dated 07/21/2009 <br /> 3. Certificate of Independence <br /> By Terrence E.Wolfe,P.E.(No.44923)@ Force Engineering&Testing,Inc. <br /> (FBC Organization#ANE ID:1920) <br /> Test Standard Equivalency: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. <br /> 2. The UL 1897-98 test standard is equivalent to the UL 1897-04 test standard. <br /> Quallty Assurante Entity: The manufacturer has established compliance of roof panel products in <br /> accordance with the Florida Building Code and Rule 9N-3.005(3)for <br /> manufacturing under a quality assurance program audited by an approved <br /> quality assurance entity. <br /> Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2010,including Section <br /> 1507.4.2 and in accordance with Manufacturers recommendations. For slopes <br /> less than 3:12,lap sealant must be used in the panel side laps. <br /> Installation: Install per manufacturer's recommended details. <br /> Underlayment: Per Manufacturer's installation guidelines per Flo�ida Building Code 2010 Section <br /> 1507.4.5. <br /> '`'��11{III1ll��I <br /> ��� E��E'�•wp��I <br /> :,,tv.t'��' � C� N�F `�,i <br /> � �• � e��£� <br /> � No.444� � <br /> � <br /> �j�f�,��ln-�.�--' *�� :�= <br /> ��� sTa�aF ;��/ <br /> .7+'. t� . <br /> '.p•c`• FZ pRI �4' •�``� <br /> :d.�� �� E"• •',�.�'�� <br /> u snn ,��������������,`, <br /> FL#11651.27 Rl February 22, 2012 <br />
The URL can be used to link to this page
Your browser does not support the video tag.