e � � <br /> �� <br /> c <br /> � FORM 405-10 <br /> - � Ftorida Code Compliance Checklisfi <br /> Florida Department af Business and Professionaf Regulatians I <br /> . . Residential Whole Building Pertormance Method '� <br /> ADDRESS: PERMIT#: <br /> ,FL, <br /> MANDATORY REQUIREMENTS SUMMARY-See Individual code sections for full details. <br /> COMPONENT SECTION SUMMARY OF REQUIREMEtJT(S) CHECK <br /> Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. <br /> Recessed lighting IC-rated as meeting ASTM E 283.Windows and <br /> doors=0.30 cfm/sq,ft.Testing or visual inspection required. Fireplaces: <br /> gasketed doors&outdoor combustion air, Must compfete envelope <br /> (eakage report or visually verify Table 402.4.2. <br /> Thermostat& 403.1 At least one thermostat shall be provided for each separate heating and <br /> controls cooling system.Where forced-air furnace is primary sysfem, <br /> programmable thermostat is required. Heat pumps with supplemental <br /> electric heat must prevent supplemental heat when compressor can <br /> meet the load. <br /> Ducts 403.22 Afl ducts, air handlers, fifter boxes and building cavities which form the <br /> primary air containment passageways for air distribution systems shall <br /> be considered ducts or plenum chambers, shall be constructed and <br /> sealed in accordance with Secfion 503.2.7.2 of this code. <br /> 403.3.3 Building framing cavities shall not be used as supply ducts. <br /> Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in <br /> Tab1e 403.4.3.2. Provide switch or clearly marked circuit breaker <br /> (electric) or shutoff(gas).Circulating system pipes insulated to=R-2 <br /> +accessible manual OFF switch. <br /> Mechanical 4U3.5 Homes designed to operate at positive pressure or with mechanical <br /> ventilaUon ventilation sysfems shafl not exceed the minimum ASHRAE 62 level. <br /> No make-up air from attics, crawlspaces, garages or outdoors adjacent <br /> to pools or spas. <br /> Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower(HP)of= 1 <br /> &Spas HP shall have the capability of operating at tw�or more speeds.Spas <br /> and heated pools must have vapor-retardant covers or a liquid cover or <br /> other means proven to reduce heat loss except if 70%of heat from <br /> site-recovered energy.Off/timer switch required. Gas heaters minirrtum <br /> therma[efficiency=78% (82%after 4/16193). Heat pump pool heaters <br /> minimum COP=4.0. <br /> Cooling/heating 4�3_6 Sizing calculation performed &attached. Minimum efficiencies per <br /> Tabfes 503.2.3. Equipment efficiency verification required. Special <br /> equipment occasion cooling or heating capacity requires separate system or <br /> variable capacity system. Elecfric heat>1 QkW musf be divided into two <br /> or more stages. <br /> Ceilings/knee walls 405.2.1 R-19 space permitting. <br /> 4/4/2012 2:20 PM EnergyGauge�USA-FlaFtes2070 Section 405.A 1 Compliant Software Page 5 of 5 <br />