My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
15-16190
Zephyrhills
>
Building Department
>
Permits
>
2015
>
15-16190
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2016 2:51:07 PM
Creation date
3/21/2016 2:51:03 PM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
15-16190
Building Department - Name
HIGHLAND HOLDINGS INC SHADY
Address
36122 SHADY BLUFF LOT 9
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
` 1 i <br /> FORM 405-10 <br /> Florida Code Compliance Checklist ; <br /> � Florida Department of Business and Professional Regulations <br /> Residential Whole Building Performance Method � <br /> ADDRESS: PERMIT#: <br /> , FL, ' <br /> MANDA70RY REQUIREMENTS SUMMARY-See individual code sections for full details. <br /> COMPONENT SECTION � SUMMARY OF REQUIREMENT(S) , CHECK <br /> - -- � <br /> Air leakage 402.4 To be caulked, gasketed, weatherstripped or othennrise sealed. <br /> Recessed lighting IC-rated as meeting ASTM E 283.Windows and <br /> doors=0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: <br /> gasketed doors 8�outdoor combustion air. Must complete envelope <br /> leakage report or visually verify Table 402.4.2. ! <br /> Thermostat& 403.1 At least one thermostat shall be provided for each separate heating and <br /> controls cooling system.Where forced-air furnace is primary system, <br /> programmable thermostat is required. Heat pumps with,supplemental <br /> electric heat must prevent supplemental heat when compressor can <br /> meet the load. <br /> Ducts 403.2.2 All ducts, air handlers,filter boxes and building cavities which form the <br /> primary air containment passageways for air distribution systems shall <br /> be considered ducts or plenum chambers, shall be constructed and <br /> sealed in accordance with Section 503.2.7.2 of this code. <br /> 403.3.3 Building framing cavities shall not be used as supply ducts. <br /> Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with e�ciencies in <br /> Table 403.4.3.2. Provide switch or clearly marked circuit breaker <br /> (electric)or shutoff(gas). Circulating system pipes insulated to= R-2 <br /> +accessible manual OFF switch. <br /> -- , <br /> Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical <br /> ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. <br /> No make-up air from attics, crawlspaces, garages or outdoors adjacent <br /> to pools or spas. '; <br /> Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower(HP)of=1 <br /> &Spas HP shall have the capability of operating at two or more speeds. Spas <br /> and heated pools must have vapor-retardant covers or a liquid cover or <br /> other means proven to reduce heat loss except if 70%of heat from <br /> site-recovered energy.Off/timer switch required. Gas heaters minimum <br /> thermal efficiency=78%(82%after 4/96/13). Heat pump pool heaters <br /> minimum COP=4.0. <br /> Coolinglheating 403.6 Sizing calcufation performed &attached. Minimum efficiencies per <br /> Tables 503.2.3, Equipment efficiency verification required.Special <br /> equipment occasion cooling or heating capacity requires separate system or <br /> variable capacity system. Electric heat>10kW must be divided into two <br /> or more stages. <br /> Ceilings/knee walls 405.2.1 R-19 spaCe permitting. <br /> 9/16/2014 11:47 AM EnergyGauge�USA-FlaRes2010 Section 405.4.7 Compliant Soitware Page 5 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.