Laserfiche WebLink
. Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.l i <br /> HVAC Designs � Walnut Grove TH i456 S+i <br /> Tam a,FL 33615 _ "''` _ __ ___ __ Page 1 j. <br />� Pro'ect Re ort __ I ____ ________ ___—j' <br /> General Project Information ! !I <br /> Project Title: Walnut Grove TH 1456 S ' I <br /> Project Date: Thursday,May 08,2014 I <br /> i <br /> Company Name: HVAC Designs Inc I � - <br /> Company Representative: Neil Fimbel ! i <br /> Company Address: 7701 W Hanna Ave � i <br /> Company City: Tampa FL 33615 i <br /> Company Phone: (813)885�2258 ' <br />' Company E-Mail Address: neil@hvacdesigns.com ; I <br /> Company Website: http:llwww.hvacdesigns.coml <br /> I ' <br /> � ----- ----- -� <br /> Design Data '� <br /> -----=-------�-- ---- ---------------------------'� <br /> Reference City: Zephyrhills,Florida � <br />� Building Orientation: Front Door faces South � <br /> Daily Temperature Range: Medium � ! <br /> Latitude: 28 Degrees � <br /> Elevation: 19 ft. i i <br /> Altitude Factor: 0.999 � I <br /> ! i <br /> Outdoor Outdoor Outdoor Ilndoor Indoor Grains � <br /> Drv Bulb Wet Bulb Rel.Hum Rel.Hum Drv Bulb Difference ; <br /> Winter: 40 37.52 nla I n!a 72 nla ; <br /> Summer: 93 77 49°/a , 55% 75 43 j <br /> I � <br /> Check Figures __ ' _____T _ _�� <br /> Total Building Supply CFM: 850 , CFM Per Square ft.: 0.584 <br /> Square ft.of Room Area: 1,456 ' Square ft.Per Ton: 837 <br /> Volume(ft')of Cond.Space: 11,647 � I <br /> Building Loads ' <br /> --. --- ---- -----J r <br />' Total Heating Required Including Ventilation Air: 20,537 Btuh 20.537 MBH <br /> Total Sensible Gain: 15,773 Btuh � SO % � <br /> Total Latent Gain: 3,917 Btuh � 20 % i <br /> Total Cooling Required Including Ventilation Air: 19,690 Btuh ,1.75 Tnns(Based On 75%Sensible Capacity) <br /> � ' f <br /> Notes ---j. - — --- -------J I <br /> Rhvac is an ACCA approved Manual J and Manual D computer program, j i <br /> Calculations are performed per ACCA Manual J 8th Edition,Version 2,and ACCA Manual D. • <br /> All computed results are estimates as building use and weather may vary. � ; <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. <br /> I � <br /> � � <br /> � <br /> i <br /> I <br /> ; � <br /> � <br /> I <br /> i <br /> i i <br /> ; <br /> _ � <br /> � i <br /> , , <br /> i <br /> I <br /> i <br /> I <br /> � <br /> i <br /> I <br /> � <br /> i <br /> I <br /> Thursday,May:08,2014,1:03 PM <br /> � <br />