Laserfiche WebLink
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.�I <br /> HVAC Desi ns x <br /> 9 �� Walnut Grove TH 1456 S!� <br /> Tampa,FL 33615 ---------__ ------------------_-=Page 4;I <br /> I Manual D Ductsize Data- Duct System 1 -Return , �; <br /> — -_ _ _-�--__-- -----------------------�I <br /> --Duct Name,etc. � —._---------------- ---------- i� <br /> Type Roughness , Diameter Velocity SPL.Duct�i <br />, Upstream Temperature ; Width Loss1100 SPL.Fit � <br /> Shape Length � Height Fit.Eq.Len SPL.Tqt � . <br /> Sizin CFM __ _Area__ __ _SP.Avail ____ SPL.Cumul I� <br /> � --- — ------- � <br /> --Duct Name:RMT-100,Feeds From:Foyer,Fitting:5•A,Effective length:49.0 ; <br /> Trunk 0.003 i 15.3 625 O.Opp j <br /> Up:Fan 75 14 0.056 0.025 I <br /> Rect 3.2 14 45.9 0.027 ; <br /> Schedule 850 �� 14.8 •0.016 0.043 ! <br /> --Duct Name:RR-100,Returns From:Foyer,Fitting:2-D,Effective Length:28.8 i <br /> Runout 0.003 � 15.3 625 i 0.001 ! <br /> Up:RMT-100 75 14 D.056 0.015 � <br /> Rect 1.1 14 27.7 0.016 � <br /> Schedule 850 � 4.9 0.000 0.016 ; <br /> _. _.. _. I I <br /> Report Units:Pressure:in.wg,Duct lengths:feet,Duct sizes:inch,Airflow:CFM,Velocity:ft.lmin,Temperature:F i <br /> i <br /> Notes: Static pressure available values for return ducts are at the entrance of the duct. For supply,they are at the exit. The cumulative static � <br /> pressure loss value for a return trunk is with respect to the entry point of the return runout upstream with the highesE static pressure available. Total I <br /> and cumulative static pressure loss values for the supply main trunk include any device pressure losses entered,and the cumulative may also I <br /> include the total static pressure loss of the return side. , � <br /> Summary ---------- -- ----------------,I I <br /> Number of active trunks: 1 — -- ---�---' <br /> Number of active runouts: 1 ; � <br /> I <br /> I <br /> Total runout outlet airflow: 850 �. <br /> Main trunk airflow: 850 <br /> I ' <br /> Largest trunk diameter: 15.3 RMT-100 j <br /> Largest runout diameter: 15.3 RR-100 � <br /> Small•sttrunk diameter: 15.3 RMT-100 i <br /> Smallest runout diameter: 15.3 RR-100 � <br /> � <br /> I <br /> Runout maximum cumulative static pressure loss: 0.016 RR•100 I <br /> Return loss added to supply: 0.043 � i <br /> Total effective length of return(ft.): 77.8 RR-100 <br /> I <br /> System duct surface area(Scenario 4): 19.7 Exposed in Space (Linked to duct Ibad) i <br /> Total system duct surface area: 19.7 � � <br /> � - - --- ---- _ I <br /> Notes ; ------�—_ �; <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. i ' I <br /> Calculations are performed per ACCA Manual J 8th Edition,Version 2,and ACCA.Manual D. I <br /> All computed results are estimates as building use and weather may vary. ' i <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. i <br /> ; <br /> i <br /> � <br /> � ! <br /> � <br /> I � <br /> i <br /> I <br /> i <br /> -- — ----— � <br /> Thursday,May O8,2014,1:03 PM <br />