<br /> Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,.lnc.I;
<br /> HVAC Designs $ Walnut Grove TN i456 S�j
<br /> Tampa,FL 33615 -- - .- ----------------------- Pa9e 6i i
<br /> -----=---------
<br /> Total Building Summary Loads � �i
<br /> Component Area i Sen Lat Sen Total I!
<br /> Descri tion Quan� Loss Gain Gain Gainj�
<br /> OP LOW E MIN:Glazing-NFRC CODE MIN Operable 2 116.3 I 1,861 0 2,960 2,960 �
<br /> Pane Low E,ground reflectance=0.23,outdoor � ;
<br /> insect screen with 50%coverage,light color blinds �', I
<br /> at 45°with 100%coverage,u-value 0.5,SHGC 0.5 � i
<br /> FD LOW E MIN:Glazing-NFRC CODE MIN Glass Door 2 20 I 320 0 278 278
<br /> Pane Low E,ground reflectance=0.23,light color '
<br /> blinds at 45°with 100%coverage,u-value 0.5, , I
<br /> SHGC 0.5
<br /> 11N:Door-Metal-Polystyrene Core 40 I 434 0 343 343 ;
<br /> 12B-Osw:Part-Frame,R•11 insulation in 2 x 4 stud 154.6 � 450 0. 300 300 j j
<br /> cavity,no board insulation,siding finish,wood � '
<br /> studs ' , -
<br /> 13A-4ocs:Wall-Block,board insulation only,R-4 board 669 I 3,082 0 1,748 1,748 I
<br /> insulation,open core,siding finish ,
<br /> 13A•4ocs:Part-Block,board insulation only,R-4 board 124 i 532 0 355 355 �
<br /> insulation,open core,siding finish i
<br /> 16B•30-ad:RooflCeiling-Under Attic with Insulation on 1455.9 i 1,491 �0 2,469 2,469 �
<br /> Attic Floor(also use for Knee Walls and Partition i
<br /> Ceilings),vented attic,no radiant barrier,R-30 I �
<br /> insulation,dark asphalt I
<br /> 22A-pm:Floor-Slab on grade,No edge insulation,no 142 ; 5,362 0 0 0 4
<br /> insulation below floor,any floor cover,passive, �
<br /> heavy dry or light wet soil
<br /> Subtotals for structure: � 13,512 0 8,453 8,453 I
<br /> People: 4 , 920 1,200 2,120 �
<br /> � Equipment: � 640 2,040 2,680 i
<br /> Lighting: 0 j 0 0 i
<br /> Ductwork: � 2,246 310 2,047 2,357 �
<br /> Infiltration:Winter CFM:136,Summer CFM:70 I 4,779 2,047 1,382 3,429 �
<br /> Ventilation:Winter CFM:0,Summer CFM:0 �i 0 0 0 0 �
<br /> AED Excursion: 0 0 652 652 i
<br /> Total Building Load Totals: 20,537 3,917 15.773 19,690 I
<br /> , I
<br /> Check Figures ------,---- ----------- ----------i i
<br /> Total Building Supply CFM: 850 ! CFM Per Square ft. 0.$84 �
<br /> Square ft.of Room Area: 1,456 I Square ft.Per Ton: 831 '
<br /> Volume(ft)of Cond.Space: 11,647 �
<br /> Building Loads � � i;
<br /> Total Heating Required Including Ve�tilation Air. 20,537 Btuh 20�.537 MBH � ���
<br /> Total Sensible Gain: 15,773 Btuh �I� 80 %
<br /> Total Latent Gain: 3,917 Btuh � 20 % ;
<br /> Total Cooling Required Including Ventilation Air: 19,690 Btuh __ �.75 Tons(Based On 75%_Sensible Capacity) i
<br /> Notes �, - - --------------- �;
<br /> Rhvac is an ACCA approved Manual J and Manual D computer program. I, "
<br /> Calculations are performed per ACCA Manual J 8th Edition,Version 2,and AGCA Nianual D. i
<br /> All computed results are estimates as building use and weather may vary. ;
<br /> Be sure to select a unit that meets both sensible and latent loads according to the manu#acturer's performance data at your design conditions. �