<br /> Rhvac-Residential&Light Commercial HVAC Loads ----Elite Software Development,Inc.�I
<br /> HVAC Designs Walnut Grove TH i202 S��
<br /> Tam a,FL 33615 _ `�____ _ _ Page 6 i f
<br /> Total Building Summary Loads �� _--___----------_�i
<br /> Component Area Sen l:at Sen Total i
<br /> Description Quan Loss Gain Gaiq Gain �
<br /> OP LOW E MIN:Glazing-NFRC CODE MIN Operable 2 52.2 835 0 654 654 �
<br /> Pane Low E,ground reflectance=0.23,outdoor I
<br /> insect screen with 50%coverage,light color blinds �
<br /> at 45°with 100%coverage,u-value 0.5,SHGC 0.5 '
<br /> FD LOW E MIN:Glazing•NFRC CODE MIN Glass Door 2 20 i 320 0 278 278 I
<br /> Pane Low E,ground reflectance=0.23,light color � i
<br /> blinds at 45°with 100%coverage,u-value 0.5, ' i
<br /> SHGC 0.5 i
<br /> 11 N:Door-Metal-•olystyrene Core 40 434 0 343 343 I
<br /> 12B-Osw:Part-Frame,R-11 insulation in 2 x 4 stud 165.4 481 0 321 321 !
<br /> cavity,no board insulation,siding finish,wood j !
<br /> studs j
<br /> 13A-0ocs:Wall Block,board insulation only,R-4 board 286.5 1,311 0 749 749 '
<br /> insulation,open core,siding finish �
<br /> 13A-4ocs:Part•Block,board insulation only,R-4 board 96 412 0 275 275 �
<br /> insulation,open core,siding finish
<br /> - 16B•30-ad:Roof/Ceiling•Under Attic with Insulation on 1202.6 i,231 0 2,041 2,041 �
<br /> Attic Floor(also use for Knee Walls and Partition �
<br /> Ceilings),vented attic,no radiant barrier,R-30 I
<br /> insulation,dark asphalt i
<br /> 22A-pm:Floor-Slab on grade,No edge insulation,no 84 3,172 0 0 0 �
<br /> insulation below floor,any floor cover,passive, I
<br /> heavy dry or light wet soil ' i
<br /> Subtotals for structure: I 8,196 0 4,667 4,661 I
<br /> People: 3 � 690 9D0 1,590 �
<br /> Equipment: 640 2,040 2,689 i
<br /> Lighting: 0 i 0 ' 0
<br /> Ductwork: � 1,733 236 1,578 1,814 I
<br /> Infiltration:Winter CFM:112,Summer CFM:58 3,948 1,691 1,142 2,833
<br /> Ventilation:Winter CFM:0,Summer CFM:0 0 0 0 0
<br /> Total Building Load Totals: i 13,877 3,257 10,321 13,578 j
<br /> �
<br />' ---- ' ;
<br /> Check Figures ----�--- ---- ---------------i,
<br /> Total Building Supply CFM: 600 f CFM Per Square ft.: � 0.499 J�
<br /> Square ft.of Room Area: 1,203 Square ft.Per Ton: 1,049 �
<br /> Volume(ft')of Cond.Space: 9,620 ,
<br /> . �
<br /> -----�-,------- ----------�-----...—----------- - -
<br /> w mg Loads -- �i
<br /> Total Heating Required Including Ventilation Air: 13,877 Btuh 13.877 MBH ---��
<br /> Total Sensible Gain: 10,321 Btuh I 76 % � i
<br /> Total Latent Gain: 3,257 Btuh i 24 % �
<br /> Total Cooling Required Including Ventilation Air: 13,578 Btuh 1.15 Tons(Based On 75%Sensibie Capacity) " �
<br /> otes --- I ----------- ------- -----------------�
<br /> ------------------- -----------------------�----------.J�
<br /> Rhvac is an ACCA approved Manual J and Manual D computer program. �
<br /> Calculations are performed per ACCA Manual J 8th Edition,Version 2,and AICCA Manual D. �
<br /> All computed results are estimates as building use and weather may vary. � �
<br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. �