Laserfiche WebLink
i � <br /> - . . <br /> _ � . . . _ ----- ---------=- _ - <br /> Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. <br /> HVAC Designs Walnut Grove TH 1 i29 S <br /> Tampa,FL 33615 +' pa9e 1�� � <br /> ,. — --- — — --- i i <br /> Project Report j � �� �� <br /> General Project Information 'i --— — ------�� � <br /> Project Title: Walnut Grove TH 1129 S � i <br /> Project Date: Thursday,May 08,2014 �. <br /> Company Name: HVAC Designs Inc i � <br /> Company Representative: Neil Fimbel � I <br /> Company Address: 7701 W Hanna Ave ' ' <br /> Company City: Tampa FL 33615 � ! I <br /> I <br /> Company Phone: (813)885-2258 j I <br /> Company E-Mail Address: neil@hvacdesigns.com j I <br /> Company Website: http:llwww.hvacdesigns.coml i � <br />' Design Data . -- ---------- ---� <br /> Reference City: Zephyrhill ,Florida � � � <br /> Building Orientation: Front Door face's South ; <br /> Daily Temperature Range: Medium ! <br /> Latitude: 28 Degrees � <br /> Elevation: 19 ft. <br /> Altitude Factor: 0.999 � i <br /> � i <br /> Outdoor Outdoor Outdoor I Indoor Indoor Grains � <br /> Drv Bulb Wet Bulb Rel.Hum Rel.Hum Drv Bulb Difference � <br /> Winter: 40 37.52 nla � n/a 72 nla I <br /> Summer: 93 77 49°/a 55% 75 43 <br /> i <br /> Check Figures i -- ---- -------'------�i <br /> Total Building Supply CFM: 600 � CFM Per Square ft. 0.531 i <br /> Square ft.of Room Area: 1,129 ; Square ft.Per Ton. �,pZg � <br /> Volume(ft')of Cond.Space: 9,034 i I <br /> Building Loads I _ _� -�-��—�i <br /> Total Heating Required Including Ventilation Air: 13,472 Btuh '13.472 MBH. I <br /> Total Sensible Gain: 9,878 Btuh i 76 % , <br /> Total Latent Gain: 3,173 Btuh � 24 "/o �i <br />, Total Cooling Required Including Ventilation Air: 13,051 Btuh i 1.10 Tons(Based On 75%Sensible Capacity) � <br /> i <br /> Notes ------'------ ---------------�! <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. I <br /> Calculations are performed per ACCA Manual J 8th Edition,Version 2,and ACCA Manual D. I <br /> All omputed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according tathe manufacturer's performance data at your design conditions. i <br /> j <br /> i � <br />' ' I <br /> i � <br /> I I <br /> i j <br /> I ' I <br /> I <br /> � I <br /> I <br /> i <br /> I <br /> � <br /> I <br /> � <br /> � <br /> � <br /> . I <br /> I <br />� i <br /> ------------- ---- -- ----------� <br /> Thursday,May 08,20i4,11:01 AM <br />