Rhvac-Residential&Light Commercial HVAC Loads � Elite Software Development;�Inc. j II <br /> HVAC Designs � Walnut Grove TN 1 i29 S i� <br /> Tampa,FL 33615 Page 6�I <br /> Total Building Summary Loads __ I ^____ ____ _____ ___i i <br /> Component Area! Sen Lat Sen Total � <br /> Descri tion Quan j Loss Gain Gain Gain 1� <br /> -OP LOW E MIN:Glazing-NFRC CODE MIN Operable 2 45.2 i 723 0 565 565 <br /> Pane Low E,ground reflectance=0.23,outdoor , <br /> insect screen with 50%coverage,light color blinds � I <br /> at 45°with 100%coverage,u-value 0.5,SHGC 0.5 , <br /> FD LOW E MIN:Glazing-NFRC CODE MIN Glass Door 2 20 320 0 278 278 <br /> Pane Low E,ground reflectance=0.23,light color ; I <br /> blinds at 45°with 100%coverage,u-value 0.5, <br /> SHGC 0.5 ' i <br /> 11N:Door-Metal•Polystyrene Core 40 � 434 0 343 343 j <br /> 126•Osw:Part-Frame,R-11 insulation in 2 x 4 stud 194.6 ` 567 0 377 377 <br /> cavity,no board insulation,siding finish,wood i <br /> studs , � <br /> 13A-4ocs:Wall-=1ock,board insulation only,R-4 board 296.2 , 1,356 0 775 775 i <br /> insulation,open core,siding finish ' j <br /> 13A-4ocs:Part-Block,board insulation only,R-4 board 92 ; 395 0 263 263 I <br /> insulation,open core,siding finish � <br /> 16B-30-ad:Roof/Ceiling-Under Attic with Insulation on 1729.3 1,157 0 1,915 1,915 ; <br /> Attic Floor(also use for Knee Walls and Partition I <br /> Ceilings),vented attic,no radiant barrier,R-30 <br /> insulation,dark asphalt <br /> 22A-pm:Floor-Slab on grade,No edge insulation,no 86 3,247 0 0 0 ; <br /> insulation below floor,any floor cover,passive, , � <br /> heavy dry or light wet soil <br /> Subtotals for structure: 8,199 . 0 4 516 4 516 � <br /> People: 3 690 �900 1,390 i <br /> Equipment: � 640 2,040 2,680 ; <br /> Lighting: 0 , 0 0 � <br /> Ductwork: 1,566 256 1,349 1,605 ; <br /> Infiltration:Winter CFM:105,Summer CFM:54 { 3,707 1,587 1,073 2,660 I <br /> i <br /> Ventilation:Winter CFM:0,Summer CFM:0 0 0 0 0 i <br /> Total Building Load Totals: � 13,472 3,173 9,878 13,051 i <br />� I � <br /> �-------------- - ----------------- -----------,! <br /> Check Figures - i; <br />, Total Building Supply CFM: 600 CFM Per Square ft.: 0.531�� —J� <br /> Square ft.of Room Area: 1,129 , Square ft.Per Ton: 1,029 �� <br /> Volume(ft)of Cond.Space: 9,034 <br /> Building Loads --------- - --_ ------�__-�� <br /> Total Heating Required Including Ventilation Air: 13,472 Btuh 13.472 MBH � � <br /> Total Sensible Gain: 9,678 Btuh ; 76 % <br /> Total Latent Gain: 3,173 Btuh � 24 % i <br /> Total Cooling Required Including Ventilation Air: 13,051 Btuh �1.10 Tons(Based On 75°/a Sensible Capacity) � <br /> Notes ---�------ �----�----- �--------_�I <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. , -----� <br />' Calculations are performed per ACCA Manual J 8th Edition,Version 2,and ACCA Manual D. <br />, All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design co�tditions. ' <br /> I � � <br /> I <br /> I <br /> I � <br />, i <br /> j <br /> i <br /> I ! <br /> i � <br /> i <br /> I <br /> I <br /> I <br /> ---- -- ------ --�--- ---------� <br /> Thursday,May 08,2014,11:01 AM <br /> _ , <br /> II � <br />