Laserfiche WebLink
I <br /> � <br /> I I <br /> I <br /> Project:Suzin Nails&Spa � <br /> Title: Interior Renovation <br /> Type: Retail <br /> (WEA File:Tampa.tmy) - <br /> Mandatory Requirements (as applicable) Material Courtesy of PNNL <br /> -COMCheck resources <br /> Topic Section Compone�t Description Yes N/A Ex _ <br /> Air Leakage C402.4.i,C402.42 Envelope The building envelope contains a continuous air � � � <br /> barrier that is sealed in an aoaroved manner and <br /> e"rther constructed or tested in an approved <br /> manner. Air barrier penetrations are sealed in an <br /> approved manner. <br /> Air Leakage C402.4.3,C402.4.4 Envelope Factory-built fenestration and doors are labeled � � � <br /> as meetinp air leakaqe requirements. <br /> Air Leakage C402.4.7 Envelope Vestibules are installed on all building entrances. � � � <br /> Doors have self-closinq devices. <br /> Air Leakage C402.4.1.1 Envelope All sources of air leakage in the building thermal � � � <br /> envelone are sealed,caulked,aasketed,weather <br /> stripped or wrapped with moisture <br /> vapor-permeable wrapping material to minimize <br /> air leakage. <br /> Air Leakage C402.4.6 Envelope Weatherseals installed on al1 loading dock cargo � � � <br /> doors. <br /> Air Leakage C402.4.8 Envelope Recessed luminaires in thermal envelope to limit � � � <br /> infiltration and be IC rated and labeled.Seal <br /> between inierior finish and luminaire housing. <br /> Fenestration C303.1.3 Envelope Fenestration products rated in accordance with � � � <br /> NFRC. <br /> Fenestration C303.1.3 Envelope Fenestration products are certified as to � � � <br /> aertormance iabels or certificates orovided. <br /> Fenestration C4022.7 Envelope U-factor of opaque doors associated with the � � � <br /> buildinq thermal envelooe meets reauirements. <br /> Insulation C303.2 Envefope Below-grade wall insulation installed per � � � <br /> manufacturer's instrucUons. <br /> Insulation C303.2 Envelope Slab edge insulation installed per manufacturer's � � � <br /> instructions. <br /> ,Insulation C4022.6 Envelope Slab edge insulaation depth/length.Slab insulaYion � � � <br /> extendinq awav from buildinq is covered bv <br /> " pavement or>=10 inches of soil. <br /> Insulation C403.2.7,C4082.8,( Envelope Exterior insulation protected against damage, � � � <br /> sunliqht,moisture,wind,landscapinq and <br /> equipment maintenance activities. <br /> Insulation C402.4.2.1 Envelope Roof R value.For some ceiling systems, � � � <br /> verification mav need to occur durinq Framina <br /> Inspection. <br /> Insulation C3032 Envelope Roof insulation installed per manufacture�s � � Q , <br /> instructions. Blown or ooured loose-fill insulation <br /> is installed only where the roof slope is<=3 in 12. <br /> Insulation C4022.1 Envelope Skylight curbs are insulated to the level of roofs � � � <br /> with insulation above deck or R-5. - <br /> Insulation C4022.1.1 Envetope High-albedo roofs satisiy one of the following: � � � <br /> 3-vear-aped solar reflectance>=0.55 and tfiermal <br /> emittance>=0.75, 3-year-�qed solar reflectance <br /> index>=64.0, initial year solar re8ectance>_ <br /> 0.70 and thertnal emittance>=0.75,or initial year <br /> solar <br /> Insulation C303.2 Envelope Above-grade wall insulation installed per � � � <br /> manufacture�'s instructions. <br /> Insulation C3032 Envelope Floor insula6on installed per manufacturer's � � � <br /> irtsiructions. <br /> Insulation C303.1 Envelope Building envelope insulation is labeled with � � � <br /> R-value or insulation certificate orovidin4 R-value <br /> � and other relevant data. <br /> � <br /> EnergyGauge Summii0 FlalCom-2014.Section 506.4 Compliant Software.Effective Date:June 30,2095 <br /> 7/14/2015 � Page 8 of 13 <br />' �. � <br /> -- - � <br /> i <br />