Laserfiche WebLink
Fenestration Used <br /> _ Name Glass Type No.of Glass SHGC VLT <br /> Panes Conductance <br /> [Btu/h.sf.F] <br /> Unlbled Single User Defined 1 1.2000 0.8000 0.7600 ❑ <br /> Clear Metal <br /> Frame <br /> Materials Used <br /> Mat No Acronym Description Only R-Value RValue Thickness Conductivity Density SpecificHeat <br /> Used [h.sf.FBtu] [ft] (Btu/h.ft.F] [lb/cf] [Btu/Ib.F] <br /> _ at o , o . . . . <br /> 48 Mat148 6 in.Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000 ❑ <br /> 123 Mat1123 CONC BLOCK No 1.7227 0.6667 0.3870 53.00 0.2000 ❑ <br /> MW,8IN,HOLLOW <br /> 57 Mat157 3/4 in.Plaster or gypsum No 0.1488 0.0625 0.4200 100.00 0.2000 ❑ <br /> 267 Mat1267 0.75" stucco No 0.1563 0.0625 0.4000 16.00 0.2000 ❑ <br /> 94 Mat194 BUII..T-UP ROOFING,3/8IN No 0.3366 0.0313 0.0930 70.00 0.3500 ❑ <br /> 407 Mat1407 R-19 Generic Insulation No 19.0000 0.4147 0.0218 0.30 0.2000 ❑ <br /> 1012 ApLbMat1012 R-5 Generic Insulation No 5.0000 0.1091 0.0218 0.30 0.2000 ❑ <br /> Constructs Used <br /> No Name Simple Massless Conductance Heat Capacity Density RValue <br /> Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.FBtu] <br /> 1005 Floor, 1 ft. soil,concrete floor,any floor No No 0.40 34.00 113.33 2.5 ❑ <br /> covering <br /> Layer Material Material Thickness Framing <br /> No. [ft] Factor <br /> 7/14/2015 EnergyGauge Snmmit0 v5.10 6 <br />