My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
15-16527
Zephyrhills
>
Building Department
>
Permits
>
2015
>
15-16527
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2016 8:49:08 AM
Creation date
6/15/2016 8:49:06 AM
Metadata
Fields
Template:
Building Department
Company Name
ADVENTIST HEALTH SYSTEM SUNBELT
Building Department - Doc Type
Permit
Permit #
15-16527
Building Department - Name
ADVENTIST HEALTH SYSTEM SUNBELT
Address
7340 DAIRY RD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
G310A-A <br /> ' Revised February 20, 2007 Page 17 <br /> _- -I <br /> � � - - <br /> SONIC RECEIVER TEST PROCEDURES DISENGAGED <br /> (Continued) i <br /> 4. Verify that the electric or qas shutoff has been ♦ <br /> activated by observing the test results. � �0 <br /> I � <br /> See"TEST RESULTS"below. � <br /> A <br /> 5. Once the shutoff (electric or gas) has activated, O <br /> reconnect the positive (+) #2 heat sensor terminal � <br /> wire connection(red lug)to the CPU board terminal " p p <br /> block, See FIGURE 3, Page 5. Once reconnected <br /> the CPU board audible alarm will cease to sound p <br /> and the CPU board will automatically reset itself. RELEASE <br /> Observe that the red LED light beside the battery SoLENOID <br /> holder blinks approximately every 45 seconds once FiGURE 26 LATCH <br /> again.This indicates the CPU board has reset itself I ENGAGED <br /> and the unit is operating. I AFTER A DISCHARGE <br /> TEST RESUL�S IN THE EVENT A FIRE SHOULD OCCUR AFTER <br /> THE GUARDIAN III SYSTEM HAS BEEN <br /> INSTALLED AND EXTINGUISHED A FIRE, <br /> Electric Stove Shutoff Un'it: Bumer coil heat PROCEED AS FOLLOWS: <br /> has decreased and all electrical power to the stove has <br /> been shut off, i.e. stove power light is off. Tum RECHARGE/REACTIVATION OF SYSTEM <br /> burner to OFF position. Reset the electric shutoff ' <br /> unit as outlined on Page 10-FIGURE 15. i CAUTION: Before replacing the fire suppressant <br /> j agent, the extinguisher cylinder, release valve <br /> Gas Stove Shutoff Unit: Burner is no longer lit I assembly, or other system components, it is <br /> and all gas to the stove has been shut off, i.e., other � recommended to wear approved type eye <br /> burners cannot be lit. Electricity is turned off if Gas protection and rubber gloves. <br /> Shutoff P/N G316-A assembly is used. Turn burner to <br /> OFF position. Reset the gas shutoff unit as outlined 1. Remove the 9V DC battery from the CPU board. <br /> on Page 12. <br /> � 2. Disconnect heat sensor 1 & 2 terminal wire <br /> connections from the CPU board and remove the <br /> CAUTION: If the Guardian III Model G300-A fails to heat sensors from underneath the range hood. <br /> operate as described for either the Interconnect Cable Both heat sensors may require replacement. <br /> or the Sonic Receiver configuration, contact the � (P/N G305-1 and G305-2) <br /> company the unit was purchased from or Twenty First <br /> Century for an authorized Twenty First Century NOTE: Insure pressure gauge indicator needle is <br /> service center for assistance. in the "Recharge" area of the gauge face prior to <br /> � disconnecting the quick connect. <br /> ARMING YOUR SYSTEIVI - <br /> 3. Disconnect the quick connect at the magnetic <br /> Insure release solenoid latch is engaged and remove base with Tee Assembly and remove the <br /> the cylinder valve safety pull pin from the extinguisher distribution assembly from undemeath the range <br /> cylinder assembly(FIGURE 26)to arm system. hood. <br /> I 4. Thoroughly flush distribution assembly with water <br /> CAUTION: Refer to initial installation, system to remove any residual fire suppressant. Inspect <br /> checkout,and activation instructions in this manual for distribution assembly(hoses, fittings, nozzles)for <br /> repositioning / re-aiming the nozzles and sensors I leaks or other damage and wipe dry with a clean <br /> anytime they are moved, removed, or reinstalled. cloth.Set assembly aside and let completely dry. <br /> (See FIGURE 22 thru FIGURE 25) <br /> � NOTE: If leaks or other damage is found in the <br /> � distribution assembly,do not reinstall distribution <br /> assembly until those parts, which are leaking or <br /> damaged, have been replaced. See Parts List, <br /> - Page 19, if required. <br /> � <br /> i <br /> I <br /> � <br /> � <br /> � <br />
The URL can be used to link to this page
Your browser does not support the video tag.