Laserfiche WebLink
. i <br /> FORM 4C�5-10 • <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professionall Regulation - Residential PerFormance Method <br /> Project me:• n�,^II ,� Builder Name: Highland Homes / �/', r r� <br /> Street: ��` r `� � I Permit Office: c��.�q D� z���t►� �t l{-� <br /> City,St , p: , L, � �. ��� PermR Number: ((p !5 t�� <br /> Owner. �hl ,� �I' S Jurisdiction: � 116do � <br /> Design Location: FL,Lakeland� � � <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1486.0 sqft.) Insulatlon Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1170.00 ft� <br /> b.Frame-Wood,Adjacent R=11.0 316.00 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 <br /> 4. Number of Bedrooms 4 d.WA R- ft� <br /> 10.Ceiling Types (1570.0 sqft.) Insulation Area <br /> 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1540.00 ft� <br /> 6. Conditioned floor area above grade(ft2) 1540 b.Knee Wall(Vented) R=30.0 30.00 ft' <br /> Conditioned floor area below grade(ft') 0 c.NIA R= ft' <br /> 11.Ducts R ft= <br /> 7. Windows(930.5 sqft.) Description Area a.Sup:Attic,Ret:Garage,AH:Garage 6.5 43 <br /> a. U-Factor: Sgl,U=0.57 98.08 ft� <br /> SHGC: SHGC=0.33 <br /> b. U-Factor: Sgl,U=0.60 32.38 ftz 12-Cooling systems kBtu/hr Efficlency <br /> SHGC: SHGC=0.30 a.Central Unit 36.� SEER:14.00 <br /> c. U-Factor: N/A ftz <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 36.0 HSPF:8.00 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.000 ft. � <br /> Area Weighted Average SHGC: 0.323 14.Hot water systems <br /> S. FloorTypes (1540.0 sqft.) Insulation Area a.Electric Cap:40gallons <br /> EF:0.920 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1540.00 ftz b. Conservation features <br /> b.N/A R= ft' None <br /> c.N/A R= ft' 15.Credits Pstat <br /> Glass/FloorArea: 0.085 Total Proposed Modified �.oads: 34.20 pASS <br /> Total Standard Reference Loads: 42.85 <br /> i <br /> I hereby ce�tify that the plans and specifications covered by I eview of the plans and ���kIL S?`.q7.� <br /> this calculation are in compliance with the Florida Energy �pecifications covered by this ty ,� � _ _ . O <br /> Code. calculation indicates compliance �+�i„'''j �'='=,,.� ✓� <br /> � with the Florida Ener Code. ti lr�,,,_'.'; .r=;r�-,''.•,�`=;��O' <br /> �\�� � ,, .._:,.--.. <br /> . .„ .. . � <br /> � � � S � � �efore construction is completed r�: - .+ <br /> PREPARED BY: I� �- �- <br /> DATE: �`1�'l y this building will be inspected for � � ff���� � � . <br /> compliance with Section 553.908 , � ° , * <br /> I hereby certify that this building,as designed,is in cor�pliance lorida Statutes. .,,+� - � <br /> with the Florida Energy �. ' C�D y�'�� <br /> OWNER/AGENT: - ��_1L1-�.L BUILDING OFFICIAL: <br /> DATE: - _ DATE: � <br /> - Compliance requires certification by the air handler unit manufecturer that the air handler enclosure qualifies as <br /> certified factory�ealed in accordance with 403.2.2.9.1. <br /> - Compliance requires completion of a Florlda Air Barrier and Insulation Inspection Checklist <br /> 9116/2014 11:47 AM EnergyGauge�USA-FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5 <br /> _ � <br />