Laserfiche WebLink
L � / �` II <br /> y•.Wy.,Se,. ,-u' ,�!} �.�,¢�Y=ti;�+,y,i.', y;.i�Si�'1� °tik�}k��.�:&^.' z-�..�� ,�_ y:.3�;i�.K': � . � � ' <br /> '�y.�, :i",G*7 ';J uY���ti .'3_ ' :d.ir�.r.' "^�;V�': _ _ ."�p`:ssa,�,j.:_.:7,�•'�: y� �ry <br />� ��'�' ���'�: �'�'`5�` a �''1't �Q����v � A ° °��[� �o m o `+�,"��t3 , ��I� <br /> :in ��,i°� r:fa� a� ���„�-, � ��A� ��, .,.��', . .,�P.. <br /> � � " k ti ��:�;.. ���• .�,q; t ' SUAPLY & MANUFACTURtNG <br /> �,,;,�., E.uL�.A;,l��-�' �4,� -.��':,#`,��'�'- ,nr�,�>x'.,. ���'�, iY< .;�,e�,w,,1 •^.�'.�"�', <br /> d <br /> � : <br /> � � � � � � � � � � 1 � <br /> � . � � � . � � � � � . � � i . <br /> -��.n <br /> Compliance Statement: The product as described in this report has demonstrated compliance with the <br /> Florida Building Code 2014, Sections 1504.3.2, 1504.7. <br /> Product Description: GulfRibr"' 3/a" Rib Roof Panel, Minimum Z9 Ga. Steel, 36" Coverage, through <br /> fastened roof panel over Minimum 1x4 Wood Purlins over one layer of Asphalt <br /> Shingles (optional) o�ier minimum �/e" OSB or minimum 15/�z" Plywood Decking. <br /> Non Structural application. <br /> I Panel Material/Standards: Material: Minimum 29 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to <br /> Florida Building Code�2014 Section 1507.4.3. <br /> Paint Finish Optional <br /> Yield Strength: Min. 102.Oksi , <br /> Corrosion Resistance� Panel Material shall comply with Florida Building Code <br /> Z014, Section 1507.4.3. <br /> Panel Dimension(s): Thickness: 0.0142" Minimum <br /> Width: 36" Coverage <br /> Rib Height: 3/a" Major Rib at 9" O.C. <br /> Panel Fastener: #9;15x1.5" HWH wii h sealing washing or approved equal <br /> %a minimum penetration through plywood. <br /> Corrosion Resistancei Per Florida Building Code Z014, Section 1506.6, 1507.4.4 <br /> Substrate Description: Minimum 1x4 No. 2 SYP wood purlins over maximum one layer of asphalt <br /> shingles(optional) over min. �fe" O5B or min.15/�" thick over supports at <br /> maximum 24" O.C.The 1 x4 wood purlins shall be fastened to the wood rafters <br /> (24" O.C. Max)with (Z) 9 x 2�/z" Deck Screws per rafter(Minimum 1�/s" <br /> penetration into wood rafter). Design of 1 x4 wood purlins, OSB, plywood and <br /> OSB/plywood supports are outside the scope of this evaluation. Must be designed <br /> in accordance w/Floirida Building Code�014. <br /> Design Uplift Pressures: Table"A° I <br /> Maximum Total Upli;ft Design Pressure 101.0 psf <br /> Fastener Pattern I 9„_9„-9"_9„ <br /> Fastener Pattern;Spacing , � 24" O.C: � • <br /> Design Pressure includes a Safety Factor=2.0. <br /> FL#11651.27 R2•1UNE 15,2015 <br /> ;�'tb�'r',�u'"r:i','.�;tr` nr�r;Ww��,�'i;:;'�;aS:�1--�+a^,.,'Lh'"g.'�',¢' :.'.�., --y.q,,,.r�:-; •,:aj ',¢,: 5;i`�';�l?�,<r„'� <br /> � � a5tr r p� ,jy, , h �, �xrNrt .r ��4,'� F1 F �y +� <br /> ���. d ��� �'ti� �°�"�����s�� ,����'e"�������^`�"4' r_ �� <br /> Y ��"Y'�" '�y1?s��;i�'��r��"� .z�r��'�,"#�_4 ii<�F.�`�i_�:z:!:.�:t�i,,.�:.�,�. ,;,r.+1,.�::5.,_t�°+`'�� <br /> � , <br /> i� � ' � � � . ' i <br /> i I <br />