TRINIIY�ERD <br /> TABLE 2C: STEEL or CONCRETE DECKS-NEW CONSTRUCf10N,REROOF(Tear-Off)or RECOVER <br /> SYSTEM TYPE D-1: INSULATED,MECHANICALLY ATTACHED ROOF COVER <br /> System Insulatio�Layer(See Note 14) Roof Cover MDP <br /> Roof Deck <br /> No• Type Attach Membrene Fasteners FastenerSpacing Lap Width Lap Spacing Seam Weld (PS� <br /> Min.22 ga.,type B, Min.1.5-inch,one or Mule-Hide EHD Fastener(steel only)or <br /> SC-32 Grade 33 steel or min. more layers,any Prelim. Mule-Hide TPO-c HDP Fastener(concrete only)and 2.4" 12-inch o.c. 5.5-inch 138.5-inch 1.5-inch _30.0 <br /> 2,500 psi concrete combination attach or TPO-c EXTRA Seam Plate o.c. ouuide <br /> Min.22 ga.,type B, Min.1.5-inch,one or Mule-Hide EHD Fastener(steel only)or <br /> SC-33 Grade 33 steel or min. more layers,any Prelim. Mule-Hide TPO-c HDP Fastener(concrete only)and 2.4" 12-inch o.c. 5.5-inch 91-inch o.c. 1.5-inch _30.0 <br /> 2,500 psi concrete combination attach or TPO-c EXTRA Seam Plate outside <br /> Min.22 ga.,type B,Grade Min.1-inch,one or more <br /> 33 steel,6 ft span,5/8" layers,any combination <br /> SC34 diameter puddle welds 6" (optlonal forrecover) Prelim. Mule-Hide TPO-c Mule-Hide EHD Plus Fasteners and 2.4" 90.5-inch 1.5-inch <br /> o.c.,side laps secured 2a" followed by 3/S-inch attach or TPO-c EXTRA Plus Seam Plates 12-inch o.c. 5.5-inch o.c. outside -30,0 <br /> o.c.w/Y."-14x1"long self- Insulfoam R-Tech EPS or <br /> tapping hex-head screw Fan-Fold <br /> Min.22 ga.,type B,Grade <br /> a3 sceel,5 ft span,5/s" Min.1-inch,one or Mule-Hide TPO-c <br /> diameter puddle welds 5" Prelim. (min.nominal 60- Mule-Hide EHD Plus Fasteners and 2.4" 90.5-inch 1.5-inch <br /> -SC=35- o.c.,side laps secured 24" -more-layers,-any pttach mil)or�PO=c -Plus Seam-Plates 12-inch o.c. 5.5-inch o.c.__outside -37.5 <br /> o.c.w/Y."-14x1"long selr- �ombtnation E�� <br /> tapping hex-head screw <br /> Min.22 ga.,type B, Min.1.5-inch,one or Mule-Hide EHD Fastener(steel only)or <br /> SC36 Grede 80 steel or min. more layers,any Prelim. Mule-Hide TPO-c HDP Fastener(concrete only)and 2.4" 12-inch o.c. 5.5-inch 115-inch o.c. 1.5-inch 37.5 <br /> 2,500 psi concrete combination attach or TPO-c EXTRA Seam Plate outside <br /> MIn.22 ga.,type B,Grede <br /> 33 steel,6 ft span,5/8" Mi�.1-illth,one or <br /> diameter puddle welds 6" Prelim. Mule-Hide TPO-c Mule-Hide EHD Fastener and 2.4"Seam 138.5-inch 1.5-inch <br /> SC-37 o.c.,side laps secured 2a" more layers,any attach or TPO-c EXTRA Plate 6-inch o.c. 5.5-inch o.c. outside -45.0 <br /> o.c.w/X"-14x1"longself- �ombl�ation <br /> tapping hex-head screw <br /> Min.22 ga.,type B, Min.1.5-inch,one or Mule-Hide EHD Plus Fasteners and 2.4" 1.5-inch <br /> SC-38 Grade 80 steel or min. more layers,any Prelim. Mule-Hide TPO-c plus Seam Plates(steel only)or HDP 12-inch o.c. 5.5-inch 115-inch o.c. -45.0 <br /> 2,500 psi concrete combination attach or TPO-c EXTRA Fastener and 2.4"Seam Plates outside <br /> Min.18 ga.,type B, Min.1.5-inch,one or prelim. Mule-Hide TPO-c Mule-Hide EHD Fasteners(steel only)or 1.5-inch <br /> SC39 Grede 33 steel or min. more layers,any attach or TPO-c EXTRA HDP Fastener(concrete only)and 2.4" 12-inch o.c. 5.5-inch 115-inch o.c. outside -45.0 <br /> 2,500 psi concrete combination Seam Plates <br /> Min.22 ga.,type B,Grade <br /> 33 steel,6 R span,5/s" Min.1-inch,one or Mule-Hide TPO-c <br /> diame2er puddle welds 6" Prelim. (min.nominal 60- Mule-Htde EHD Fastener and 2.4"Seam 114.5-inch 1.5-inch <br /> SC-40 o.c.,side laps secured 24" more layers,any attach mil)or TPO-c Plate 6-inch o.c. 5.5-inch o� outside -45.0 <br /> o.c.w/Y."-14x1"long self- �ombination E�� <br /> tapping hex-head screw <br /> Exterior Research and Design,LLC.d/b/a Triniry�ERD Evaluation Report M1506D.06.09-R3 for FL12772-R3 <br /> Certiflcate of Authorization it9503 Revision 3:03/18/2015 <br /> Prepared by: Robert Nfeminen,PE-59166 Appendix 1,Page 8 of 18 <br />