Laserfiche WebLink
TRINITY�ERD <br /> TABLE 2C: STEEL or CONCRETE DECKS-NEW CONSTRUCTION,REROOP(Tear-Off)or RECOVER <br /> SYSTEM TYPE D-1: INSULATED,MECHANICALLY ATTACHED ROOF COVER <br /> System Insulation Layer(See Note 14) Roof Cover MDP <br /> Roof Deck <br /> No. Type Attaeh Membrane Fasteners Fastener Spacing Lap Wfdth Lap Spacing Seam Weld (Psfl <br /> Min.22 ga.,type B,6rade Min.l-fnch,one or more <br /> 33 steel,6 ft span,5/8" layers,any combination <br /> diameterpuddle welds 6" (optional for recover) Prelim. Mule-Hide TPO-c Mule-Hide EHD Fastener and 2.4"Seam 138.5-inch 1.5-inch <br /> SC-50 6-inch o.c. 5.5-inch -60.0 <br /> o.c.,side laps secured 24" followed by 3/8-inch attach of TPO-c EXTRA Plate o.c. outside <br /> o.c.w/Y."-14x1"long self- Insulfoam R-Tech EPS or <br /> tapping hex-head screw Fan-Fold <br /> Min.22 ga.,type 8, Min.1.5-inch,one or Mule-Hide EHD Plus Fasteners and 2.4" <br /> SC-51 Grede 33 steel or min. more layers,any Prelim. Mule-H(de TPO-c Plus Seam Piates(steel only)or HDP 6-inch o.c. 5.5-inch 138.5-inch 1.5-inch _60.0 <br /> ' 2,500 psi concrete combination attach or TPO-c EXTRA Fastener and 2.4"Seam Plates o•c. outside <br /> Min.22 ga.,type B, Min.1.5-inch,one or Mule-Hfde EHD Fastener(steel only)or <br /> SC-52 Grede 80 steel or min. more layers,any Prelim. Mule-Hide TPO-c HDP Fastener(concrete only)and 2.4" 6-inch o.c. 5.5-inch 138.5-inch 1.5-inch _60.0 <br /> 2,500 psi concrete combination attach or TPO-c EXTRA Seam Plate o.c. outside <br /> Min.1.5-inch,one or <br /> Min.22 ga.,type B, more layers,any Mule-Hide EHD Fastener(steel only)or <br /> SC-53 Grede 33 steel or min. combination followed Loose laid Mule-Hide TPO-c HDP Fastener(concrete only)and 2.4" 6-inch o.c 5.5-inch 91-inch o.c. 1.5-inch _60.0 <br /> - _or_iP_O-c_EXTRQ__ outside <br /> 2,500 psi concrete by 3/8-inch Insulfoam - Seam Plate - <br /> R-Tech EPS <br /> Min.22 ga.,type B, Min.1.5-inch,one or Mule-Hide EHD Fastener(steel only)or <br /> SC-54 Grade 33 steel or min. more layers,any Prelim. Mule-Hide TPO-c HDP Fastener(concrete only)and 2.4" 12-inch o.c. 5.5-inch 54.5-inch 1.5-inch _60.0 <br /> 2,500 psi concrete combination attach or TPO-c EXTRA Seam Plate o.c. outside <br /> Min.22 ga.,type B, Min.1.5-inch,one or Mule-Hide EHD Fastener(steel only)or <br /> SC-55 Grede 33 steel or min. more layers,any Prelim. Mule-Hide TPO-c HDP Fastener(concrete only)and 2.4" 6-inch o.c. 5.5-inch 90.5-inch 1.5-inch _67.5 <br /> 2,500 psi concrete combination attach or TPO-c EXTRA Seam Plate o.c. outside <br /> Min.22 ga.,type B, Min.1.5-inch,one or Mule-Hide EHD Fastener(steel only)or <br /> SC-56 Grade 80 steei or min. more layers,any Prelim. Mule-Hide TPO-c HDP Fastener(concrete only)and 2.4" 9-inch o.c. S.5-inch 54.5-inch 1.5-inch _75.0 <br /> 2,500 psi concrete combination attach or TPO-c EXTRA Seam Plate o.c. outside <br /> Min.22 ga.,type B, Min.1.5-inch,one or Mule-Hide EHD Fastener(steel only)or <br /> SC-57 Grade 33 steel or min. more layers,any Prelim. Mule-Hide TPO-c HDP Fastener(concrete only)and 2.4" 6-inch o.c. 5.5-inch 42.5-inch 1.5-inch $Z 5 <br /> 2,500 psi concrete combination attach or TPO-c EXTRA Seam Plate o.c. outside <br /> Min.22 ga.,type B, Min.1.5-inch,one or Mule-Hide EHD Fastener(steel only)or <br /> SC-58 Grade 80 steel or min. more fayers,any Prelim. Mule-Hide TPO-c HDP Fastener(concrete only)and 2.4" 6-inch o.c. 5.5-inch 54.5-inch 1.5-inch _g0.0 <br /> 2,500 psi concrete combination attach or TPO-c EXTRA Seam Plate o.c. outside <br /> Evaluation Re ort M15060.06.09-R3 for FL12772-R3 <br /> Exterior Research and Desi n,LLC,d/b/a Trini ERD P <br /> B N� <br /> Certificate of Authorization q9503 Revision 3:03/18/2015 <br /> Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 10 of 18 <br />