Laserfiche WebLink
� <br /> � �,` <br /> � • <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CO�E FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Profession I Regulation - Residential Performance Method <br /> Project Name: R0815283LTE Builder Name: Tampa Bay Drafting&Design Scott Jaworski <br /> Street: 3732 Garden City Way Permit Office: Ci�of Zephyrhills <br /> City,State,Zip: Zephyrhiils,FL, Permit Number:� �p/�Q <br /> Owner: Waitman Residence Jurisdiction: 611600 <br /> Design Location: FL,Tampa <br /> 1 New construction or existing New(From Plans) 9. Wall Types(1053.4 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1053.40 ft2 <br /> b.N/A R= f F <br /> 3. Number of units,if multiple family 1 c.N/A R= f f <br /> 4 Number of Bedrooms 2 d.N/A R= f[ <br /> 5. Is this a worst case? No 10.Ceiling Types (876.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 876.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 876 b.N/A R= f f <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= f[ <br /> 11.Ducts R ft2 <br /> 7. Windows(168.0 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:First Floor 6 175 <br /> a. U-Factor: Dbl,U=0.29 100.50 ft2 <br /> SHGC: SHGC=0.21 <br /> b. U-Factor: Dbl,U=0.65 67.50 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.30 a.Central Unit 30.0 SEER:14.00 <br /> c. U-Factor• N/A f f <br /> SHGC: 13.Heating systems kBtu/hr E�ciency <br /> d. U-Factor: N/A f F a.Electric Heat Pump 30.0 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.000 ft. <br /> Area Weighted Average SHGC: 0.246 14.Hot water systems <br /> a.Electric Cap:20 gallons <br /> 8. FloorTypes (876.0 sqft.) Insulation Area EF:0.970 <br /> a.Crawispace R=19.0 876.00 ftZ b. Cortservation features <br /> b.N/A R= f t None , <br /> c.N/A R= f f 15.Credits CF,Pstat <br /> Glass/Floor Area: 0.192 Total Proposed Modified Loads: 37.40 pASS <br /> Total Baseline L�oads: 38.20 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ����?`,��,� <br /> this calculation are in compliance with the Florida Energy specifications covered by this ; =� �� . <br /> ��' �: <br /> Code. ��/�`� calculation indicates compliance ��'of,,° , '=�� <br /> ,rK with the Florida Energy Code. � tn; , w :;.`-.,`;.`��'`„�O <br /> PREPARED BY: Before construction is completed cs� • �.° <br /> DATE: 0 - 4- 5 this building will be inspected for � - '���"�� � <br /> compliance with Section 553.908 �. � <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. ,� . ; �� <br /> with the Florida Energy Code. � (l '�'4D�„*� . <br /> OWNER/AGENT: BUILDING OFF IA�,: <br /> DATE: DATE: " ` <br /> - Compliance requires certification by the air handler unit manu cturer that the air handler enc osure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insufation Inspection C ecklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> 8/14/2015 4:33 PM EnergyGaugeO USA-FlaRes2014 ection R405.4.1 Compliant Software Page 1 of 4 <br />� <br />