My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
15-16633
Zephyrhills
>
Building Department
>
Permits
>
2015
>
15-16633
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2016 11:37:19 AM
Creation date
6/15/2016 11:37:19 AM
Metadata
Fields
Template:
Building Department
Company Name
ALPHA VILLAGE
Building Department - Doc Type
Permit
Permit #
15-16633
Building Department - Name
SHEPARD,GILBERT & GLADYS
Address
7228 OMEGA CT
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, � <br /> FORMS <br /> ; TABLE 402A , , <br /> J <br /> BUILDING COMPONENT PERFORMANCE CRITERIA' INSTALLED VALUES: i <br /> U-Factor<0.65 �! � <br /> U-Factor= ��p��j � .�30 <br /> Windows(see'.Note 2):, .. _ ,. „ :' SMGC:=.0.30, •' .� .�I->4 � �-SHGC`'' ' ���-i' ' i <br /> � - ' ' %�of CFA<=20% " - •.�O ' <br /> � s �„.'•, U-FaCtor<:0.75 ' %ot CFA=..��;�'�+., . - ..... , <br /> Doors:E - actor "' '�`" � U-Factor a 0:65 ' " � : U-Factdr.,: ' <br /> Floor Slatron-grade, , +, ,� No requirement � <br /> ver unconditioned s'ace`s see Note 3 R-13 - ' R-Value= <br /> Walls-Ext.and Adj.(see Note 3): <br /> Frame q-13 R-Value= <br /> Mass (see Note 3) ' <br /> Interior of wall: R-7.8 R-Value= 7•8 <br /> Exterior of wall: R-6 R-Value= <br /> Ceiiings(see Notes 3&4) � R=30 R-Value=,3Q Tesl report�i,� <br /> Reflectance 025 A Retlectance= yrie No ' �� <br /> Air distribution system(see Note 4) <br /> a Ductwork&air handling unit: <br /> Unconditioned space , Not allowed Location: Test report <br /> Conditioned space A�_ ° ? <br /> Duct R-value —EX�G Ex�'•.S,T/,��: -„ R-value z 6 Y ��o <br /> R-Value= 6 /�O <br /> Air leakage�n _ �n 5 0.03 ��_ <br /> Air canditionin s stems see Note 5 � '�'.' \ � ` SEER=13.0 SEER= . <br /> Heating system �� �-X�,j'�►��"ji <br /> Heat pump(see Note 5) Cooling: ;4, SEER=13.0 � SEER= <br /> Heating: � - . HSPF=7.7 ' HSPF= _ <br /> y,i 1 . <br /> Gas fumace • "�`�' " AFUE 78% AFUE_ <br /> Oil fumece AFUE 78% AFUE_ <br /> Eledric resistance:Not allowed(see Note 5) �. � <br /> :.r . . <br /> Water heating system(storage lype) �A, „��/;f!rJ G <br /> Electric(see Note 6): �-.s_ 40 gal:EF=0.92 Gallons= �� <br /> I Gas fired(see Note 7: � 50 gal:EF=0.90 EF= (J�/A[q/dL✓� <br /> ) 40 gal:EF=0.59 Gallons= <br /> Other(describe): 50 gal:EF=0.58 EF= <br /> ,---.'... „ <br /> (i)Each component present in the As P.roposed home must meet or exceed each of the applicable performance criteria in�orderto comply with this code using tFiis method; <br /> otherwise Section 405 compliance must be used. <br /> ., <br /> (2)Windows and doors qualifying as glazed fenestr'ation areas must complywith both the maximum U-Factor�and the maximum SHGC(solar Heat Gain Coefficient)criteria <br /> and have a maximum total window area equal'to or less than 20%of the conditioned floor area(CFA);�otherwise Section 405 must be used for compliance. ' <br /> Exception: Additions of 600 square feet(56 m2)or less may have a maximum glass to CFA of 50 percent. <br /> (3)R-values are for insulation material only as applied in accordance with manufacturers'installation instructions.For mass walls,the interior of wall°requirement must be <br /> met except if at least 50%of�ihe R-6 insulation required for the"exterior of wall"is instailed exterior of,or integral to,the wall. . <br /> (4)Ducts&AHU installed substantially leak iree per Section 4032.2.1.Test by Class 1 BERS reter required. <br /> Exception:Ducts installed onto an exist'ing��r distribution system as part of an addition or renovation;duct must be R-6 installed per Sec.503.2.7.2. <br /> (5)For all conventional units with capacities gr'eater than 90,000 Btu/hr For other types of equipment,see Tables 503.2.3(1-8). <br /> Exception:The prohibition on electric�esistance heat does not apply to additions,renovations and new heating systems installed in existing buildings. <br /> (6)For other electric storage volumes,minimum EF=0.97-(0.00132 x volume). <br /> (7)For other natural�gas§Corage volumes;minimum EF=0.67-(0.0019 x volume). <br /> � i, G <br /> TABLE 4028 MANDATORY REDUIREMENTS . - • �• ` � ' . „ , <br /> COMPONENTS^ SECTION . RE�UIREMENTS CHECK <br /> ' To be caulked,gasketed,weatherstripped or otherwise sealed.Recessed lighting IC-reted es meeting ASTM E <br /> Air leakage 402.4 283.Windows and doors=0.30 ciMsq.R.Testing or visual inspection required.Fireplaces:gasketed doors& <br /> - - �`.;outdoor combustion air. <br /> Ceilings/lmee walls 405.2.1', R-19 space paimitting. <br /> Programmable thermostat 403.1 1 Where forced-air fumace is primary system,programmable thermostat is required. I <br /> Air disVibution syslem 403.2 � � `Ducts in attics or on raofs insuteted ta R-8;other ducts R-6.Ducts tesled to Q�=0.03 by a Class 1 BERS rater. <br /> � Heat trap requfred for vertical pipe risers.Compty with etticiencies in Table 403.4.32.Provide switch or clearly <br /> Water heaters 403.4 marked circuit breaker(electric)or shutoH (ges).Circulating system pipe,s fnsulated to=R-2+accessible manual <br /> OFF switch. <br /> Spas and heated pools must heve vapor-ietardant cover's or a'liquid cover or other mearis proven to reduce heat <br /> Swimming pool&spes 403.9 loss except'rf 70%of heat from site-recovered energy.OHltimer switch required.Gas heaters minimum thermal <br /> , efficien =7B% 82%after M16/13.Heat um oot heaters minimum COP=4.0. <br /> � � � � ` Siiing calculatfon performed&attached.Minimum eHiciencies per Tables 5032.3.Equipment efficiency verification <br />, Cooling/Iteating equipment �`403:6 - � ' iequired.Special occasion cooting or heating capacity requires separate system or variable capacity system. <br /> Electric heat>10kW must be divided into two or more sta es. <br /> Lighting equipment 404.1 At"least 50%of permenently installed lighting fixtures shall be high-efficacy lamps. <br /> ' , , . .. � � <br /> 2010 FLORIDA BUILDING CODE—ENERGY COMSERVATION C,� <br />
The URL can be used to link to this page
Your browser does not support the video tag.