Laserfiche WebLink
�� -._...-� <br /> 11. For existin substretes i b �4f ��I�I����D <br /> g n a onded recover installation,the existing roof surface shall be examined for compatibility and bond performance with the selected adhesive,and the existing roof system shall be capable of <br /> resisting project design pressures on its own merit to the satisfaction of the AHJ,as documented through field uplift testing in accordance with ASTM E907,FM LPDS 1-52 or ANSI/SPRI IA-1. <br /> 12. For Recover Applications using System Type D,the insulation is optional. Alternatively, min.0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra, <br /> Strudodek High Density Fiberboard Roof Insulation,EnergyGuard RH HD Polyiso Insulation,EnergyGuard HD Polyiso Insulation or EnergyGuard HD Plus Polyiso Insulation or min.0.25-inch Dens Deck,Dens Deck Prime <br /> or SECUROCK Gypsum-Fiber Roof Board or SECUROCK Glass-Mat Roof Board may be used as a separetor board prior to base sheet installation. The existing roof system shall be suitable for a recover application. The <br /> separator component shall be documented as meeting FBC 1505.1 and,for foam plastic,FBC 2603.4.1 or 2603.6,when installed with the roof cover in Recover applications. <br /> 13. Unless otherwise noted,refer to the following references for bonded base,ply or cap sheet applications. <br /> Reference Layer Material Application <br /> BP-AA Base: GAFGLAS t175 Base Sheet,Trl-Ply#75 Base Sheet,GAFGLAS q80 Ultima Base Sheet <br /> (Base/Ply sheets,Asphalt-Applied) ply: One or more plies GAFGLAS Ply 4,Tri-Ply Ply 4,GAFGLAS FlexPly 6 Hot asphalt at 25 Ibs/square. <br /> BP-CA Matrix'"102 5B5 Membrane Adhesive <br /> (Base/Ply sheets,Cold-Applied) Base: GAFGLAS#75 Base Sheet,Tri-Ply ti75 Base Sheet (formerly known as TOPCOAT MATR/X 102 <br /> SBS Membrane Adhesive)at 1.5 gal/sq. <br /> B-LL <br /> (Base sheet,Loose-Laid) Base: GAFGLAS Stretavent Perforated Venting Base Sheet Loose laid <br /> Base or Ply One or rivo plies Ruberoid ZO Smooth,Ruberoid Mop Smooth,Ruberoid Mop Smooth 1.5,Ruberoid Mop Plus Smooth <br /> SBS-AA Ruberoid 30 Grenule,Ruberoid 30 Grenule FR,Ruberoid EnergyCap 30 Grenule FR,Ruberoid Mop Smooth,Ruberoid Mop <br /> SBS,As hal[-A lied Hat asphalt at 25 Ibs/square. <br /> ( P PP� 1 Cap: Smooth 1.5,Ruberoid Mop Plus Smooth,Ruberofd Mop Granule FR,Ruberoid Mop Grenule,Tri-Ply SBS Granule,Intec <br /> Flex PRF,Ruberoid Mop Plus Granule FR,Ruberoid Mop Plus Granule,Ruberoid EnergyCap Mop Plus Granule FR <br /> SBS-CA Base or Ply: Ruberoid 20 Smooth Matrix'"102 SBS Membrane Adhesive <br /> (SBS,Cold-Applied,Matrix'"102 SBS Ruberoid 30 Granule FR,Ru6eroid EnergyCap 30 Grenule FR,Ruberoid Mop Granule FR,Ruberoid Mop Plus Granule FR, (jormerly known os TOPCOAT MATRIX 102 <br /> Membrene Adhesive) �aP' Ruberoid EnergyCap Mop Plus Granule FR SBS Mem6rane Adhesive)at 1.5 gal/sq. <br /> Matrix'"101 Premium SBS Membrane <br /> SBS-CA-1 Base: Ruberoid 20 Smooth or Ruberoid Mop Smooth 1.5 Adhesive(formerly known as TOPCOAT <br /> (SBS,Cold-Applied,Matrix'"301 MATR/X Majorbond Modified Bitumen <br /> Premium SBS Membrane Adhesive) �aP: Ruberoid 30 Granule FR,Ruberoid EnergyCap 30 Granule FR,Ruberoid Mop Plus Granule FR,Ruberoid EnergyCap Mop MembraneAdhesivef at 1.5—2.0 <br /> Plus Granule FR <br /> galJsquare <br /> SBS-TA <br /> Base or Ply: One or two plies Ruberoid HW 25 Smooth,Ruberofd HW Smooth <br /> (SBS,Torch-Applied) �a Ruberoid HW Grenule,Ruberoid HW Grenule FR,Ruberoid HW Plus Grenule,Ruberoid HW Plus Granule FR,Ruberoid <br /> P' EnergyCap HW Plus Granule FR <br /> APP-TA <br /> Base or Ply: One or two plies Ruberoid Torch Smooth,Tri-Ply APP Smooth Torch applied <br /> (APP,Torch-Applied) �a Ruberoid Torch Grenule,Tri-Ply APP Granule,Ruberoid Torch Plus Grenule FR,Ruberoid EnergyCap Torch Granule FR, <br /> P' Ruberoid EnergyCap Torch Plus Grenule FR <br /> Base or Ply: Liberty SBS Self-Adhering Base/Ply Sheet <br /> SBS-SA(self-adhering) Self-adhered <br /> Cap Liberty SBS Self-Adhering Cap Shee[ <br /> 14. "MDP"=Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads.Refer to FBC 1609 for determination of design wind loads. <br /> Exterior Research and Design,LLC.d/b/a Trinity�ERD Evaluation Report 01506.11.04-R15 for FL5680-R15 <br /> Certificate of Authorization#9503 Revision 15:04/06/2015 <br /> Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 3 of 76 <br />