Laserfiche WebLink
�. '. ��, r�u�n■ �vv�rr�a <br /> Site Preparation <br /> POCKET PENETROMETER TEST `� <br /> Debris and organic material removed <br /> The pocket penetrometer tests are rounded down to��� psf Water drainage:Natural Swale Pad��Other ' <br /> or check here to declare 1000 Ib.soil without testing. - <br /> X ��� X� X �[p(� Fastening multl wide units <br /> Floor: Type stener: Length: Sp ' <br /> Walls: Type Fa Length: acing: - <br /> POCKET PENETROMETER TESTIPIG METHOD Roof: Type Fastener: Lengt • Spacing: <br /> For used homes a min. e,S"wide,galvanized metal strip <br /> 1. Test the perimeter of the home at 6 locations. will be centered over eak o of and fastened with galv. <br /> roofing nails a ' n center on both side e centerline. <br /> 2. Take the reading at the depth of the footer. <br /> k we t r r ofl re Iremant <br /> 3. Using 500 Ib.increments,take the lowest <br /> reading and round down to that increment. I understand a properly installed gasket is a requirement of all new and used <br /> homes and that condensation,mold, meldew and buckled marriage walls are <br /> a result of a poorly installed or no gasket being installed. I understand a strip <br /> X��� X�� X�(�(� of tape will no�e s a gasket. <br /> aller's initials <br /> TORQUE PROBE TEST <br /> Tvpe qasket Inst . <br /> The results of the torque probe test is inch pounds or check Pg. etween Floors <br /> here if you are declaring 5'anchors without testing . A test Between Walls Yes <br /> showing 275 inch pounds or less will require 5 foot anchors. Bottom of ridgebeam Yes <br /> Note: A state approved lateral arm system is being used and 4 ft. <br /> anchors are allowed at the sidewall locations. I understand 5 ft Weatherproot�ng <br /> anchors are required at all centerline tie points where the torque test / <br /> reading is 275 or less and where the mobile home manufacturer may The bottomboard wili be repaired and/or taped. Yes �/ . Pg. <br /> requires anchors with 40�I��i�io ding capacity. Siding on units is installed to manufacturer's specifications. Yes �� / <br /> � Installer's initials Fireplace chimney installed so as not to allow intrusion of rain water. Yes v <br /> ALL TESTS M�1STU�RFS2RME BY A LICENSED INSTALLER �Uflscellaoeous <br /> Installer Name V1 �(� Skirting to be installed. Yes No / � <br /> Dryer vent installed outside of skirting. Yes ✓ N/A <br /> Date Tested � 2 Range downflow vent instafled outside of skirting. Yes �N/A <br /> Drain lines supported at 4 foot intervals. Yes:✓ <br /> Electrical crossovers protected. Yes1� <br /> Other ; <br /> Electrical <br /> Connect electrical conductors between multi-wide units, but not to the main power <br /> source. This includes the bonding wire between mult-wide units. Pg. � <br /> Installer verifies all information gtven with this permit worksheet <br />' um na is accurate and true based on the <br /> manufacturer's Installation lnstructions and or Rule 15C-1 &2 <br /> Connect�all sewer drains to an existing sewer tap or septic tank. Pg. <br /> Connect all potable water supply piping to an existing water meter,water tap,or other <br /> Installer Sig�ature Date`� ✓� /5� <br /> independent water supply systems. Pg. <br />