Laserfiche WebLink
TFP171 <br /> Page 5 of 10 <br /> SPRINKLER FINISH(See Note 5) <br /> K BULB LIQUID NATURAL CHROME SIGNAL*** <br /> FACTOR TYPE TEMPERATURE COLOR BRASS PLATED WHITE <br /> 135°F(57°C) Orange <br /> PENDENT 155°F(68°C) Red <br /> (TY1231) <br /> and 175°F(79°C) Yellow 1,2,3,4 <br /> UPRIGHT 200°F 93°C) Green I <br /> (TY1131) � <br /> • 286°F(141°C) Blue <br /> 135°F(57°C) Orange <br /> 2,g RECESSED 155°F 68°C) Red <br /> , 1/2"NPT PENDENT � <br /> (TY1231)* 175°F(79°C) Yellow <br /> Figure 6 <br /> 200°F(93°C) Green <br /> 1,2,4 <br /> 135°F(57°C) Orange <br /> RECESSED �55 F(68°C) Red <br /> PENDENT � <br /> (TY1231)** 175°F(79°C) Yellow - <br /> Figure 7 <br /> 200°F(93°C) Green <br /> 135°F(57°C) Orange <br /> PENDENT 155°F(68°C) Red <br /> (TY2231) <br /> and 175°F(79°C) Yellow <br /> UPRIGHT 200°F(93°C Green <br /> (TY2131) ) <br /> 286°F(141°C) Blue <br />� 135°F(57°C) Orange <br /> 4,2 RECESSED 155°F 68°C Red 1,2 <br /> 1/2"NPT PENDENT � � <br /> (TY2231)* �75°F(79°C) Yellow <br /> Figure 8 <br /> 200°F(93°C) Green <br /> 135°F(57°C) Orange <br /> RECESSED 155°F 68°C Red <br /> PENDENT � � <br /> (TY2231)** 175°F(79°C) Yellow <br /> Figure 9 <br /> 200°F(93°C) Green <br /> NOTES: <br /> 1. Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers. <br /> 2. Listed by Underwriters Laboratories,Inc.,for use in Canada(C-UL)as Quick Response Sprinklers. <br /> 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. <br /> 4. Approved by the City of New York under MEA 354-01-E. <br /> 5. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed <br /> as Corrosion-Resistant Sprinklers. <br /> 'Installed with Style 10(1/2"NP�or Style 40(3/4"NP�3/4"Total Adjustment Recessed Escutcheon,as applicable. <br /> `"Installed with Style 20(1/2"NP�or Style 30(3/4"NPI�1/2"Total Adjustment Recessed Escutcheon,as applicable. <br /> *"Frame and Deflector only Listings and approvals apply to color(Special Order). <br /> N/A.Not Available <br /> TABLE A <br /> LABORATORY LISTINGS AND APPROVALS FOR <br /> 2.8 AND 4.2 K-FACTOR SPRINKLERS <br /> 15). With reference to Figures 1 to 4, <br /> apply the W-Type 7 Recessed Sprinkler <br /> Wrench to the sprinkler wrench flats. <br /> Step C. After ceiling installation and � <br /> finishing,slide on the Style 10,20,30, <br /> or 40 Closure over the Series TY-FRB <br /> Sprinkler and push the Closure over the <br /> Mounting Plate until its flange comes in <br /> contact with the ceiling. I <br />