My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
16-17272
Zephyrhills
>
Building Department
>
Permits
>
2016
>
16-17272
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/31/2016 1:13:23 PM
Creation date
10/31/2016 1:11:48 PM
Metadata
Fields
Template:
Building Department
Company Name
ZEPHYR II LLC
Building Department - Doc Type
Permit
Permit #
16-17272
Building Department - Name
ZEPHYR II LLC
Address
5935 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' TFP171 <br /> Page 7 of 10 <br /> SPRINKLER FINISH <br /> K TYPE NATURAL CHROME SIGNAL LEAD <br /> FACTOR BRASS PLATED WHITE COATED <br /> PENDENT(TY1231) <br /> and <br /> 2$ UPRIGHT(TY1131) 175 PSI(12,1 BAR) N/A <br /> 1/2"NPT <br /> RECESSED <br /> PENDENT(TY1231) <br /> PENDENT(TY2231) <br /> and <br /> UPRIGHT(TY2131) <br /> 4'2 175 PSI(12,1 BAR) N/A <br /> ' 1/2"NPT <br /> RECESSED <br /> PENDENT(TY2231) <br /> PENDENT(TY3231) 175 PSI <br /> UPRIGHT(TY3131) 250 PSI(17,2 BAR) (12,1 BAR) <br /> 5.6 OR 175 PSI(12,1 BAR) <br /> 1/2"NPT (SEE NOTE 1) <br /> RECESSED N/A <br /> PENDENT(TY3231) <br /> PENDENT(TY4231) 175 PSI <br /> and (12,1 BAR) <br /> UPRIGHT(TY4131) <br /> $'� 175 PSI(12,1 BAR) <br /> 3/4"NPT <br /> RECESSED N/A <br /> PENDENT(TY4231) <br /> PENDENT(TY4931) <br />� 1/2$NPT and 175 PSI(12,1 BAR) (12?1 AR) <br /> UPRIGHT(TY4831) <br /> NOTES: <br /> 1. The maximum working pressure of 250 psi(17,2 bar)only applies to the Listing by Underwriters Laboratories Inc.(UL);the <br /> Listing by Underwriters Laboratories,Inc.for use in Canada(C-UL);and,the Approval by the City of New York. <br />� TABLE C <br /> MAXIMUM WORKING PRESSURE <br /> Care and corrosive products of combustion, but tion Service in accordance with local <br /> have not operated, should be replaced requirements and/or national codes. <br />� ' if they cannot be completely cleaned <br /> Ma�ntenance by wiping the sprinkler with a cloth or Care must be exercised to avoid dam- <br /> The TYCO Series TY-FRB must be by brushing it with a soft bristle brush. age to the sprinklers -before, during, <br /> maintained and serviced in accordance and after installation. Sprinklers dam- <br /> Care must be exercised to avoid dam- aged by dropping, striking, wrench <br /> with this section. age to the sprinklers - before, during, twist/slippage, or the like, must be <br /> Before closing a fire protection system and after installation.Sprinklers dam- replaced. Also, replace any sprinkler <br /> main control valve for maintenance aged by dropping, striking, wrench that has a cracked bulb or that has lost <br /> work on the fire protection system twist/slippage, or the like, must be liquid from its bulb. (Ref. Installation <br /> that it controls, obtain permission to replaced. Also, replace any sprinkler Section). <br /> shut down the affected fire protection that has a cracked bulb or that has lost <br /> systems from the proper authorities liquid from its bulb. (Ref. Installation Initial and frequent visual inspections of <br /> and notify all personnel who may be Section.) random samples are recommended for <br /> �corrosion-resistant sprinklers to verify <br /> affected by this action. The owner is responsible for the the integrity of the corrosion-resistant <br /> Absence of the outer piece of an inspection,testing,and maintenance of material of construction. Thereafter, <br /> escutcheon, which is used to cover their fire protection system and devices annual inspections per NFPA 25 should <br /> a clearance hole, can delay sprinkler in compliance with this document, as suffice. <br /> operation in a fire situation. well as with the applicable standards <br /> of the National Fire Protection Associa- Inspections of corrosion-resistant <br /> Sprinklers which are found to be leak- tion (e.g., NFPA 25), in addition to the sprinklers are recommended at close <br /> ing or exhibiting visible signs of corro- standards of any other authorities hav- range, instead of from the floor level � <br /> sion must be replaced. ing jurisdiction. Contact the installing per NFPA. Inspection at close range ' <br /> Automatic sprinklers must never be contractor or sprinkler manufacturer can better determine the exact sprin- <br /> painted, plated, coated, or other- regarding any questions. kler condition and the long-term integ- <br /> rity of the corrosion-resistant material, <br /> wise altered after leaving the factory. Automatic sprinkler systems are rec- Which can be affected by the corrosive <br /> Modified sprinklers must be replaced. ommended to be inspected, tested, conditions present. <br /> Sprinklers that have been exposed to and maintained by a qualified Inspec- <br />
The URL can be used to link to this page
Your browser does not support the video tag.