Laserfiche WebLink
WALLS <br /> Adjacent Space Cavity Width Height Sheathing Framing Solar Below <br /> 1 NE=>SW Exterior Concrete Block-Ext Insul Main 4.1 44 4 8 0 354.7 ftz 0 0 0.8 0 <br /> 2 SE=>NW Exterior Concrete Block-Ext Insul Main 4.1 34 0 8 0 272.0 ft2 0 0 0.8 0 <br /> 3 SW=>NE Exterior Concrete Block-Ext Insul Main 4.1 46 4 8 0 370.7 ftz 0 0 0.8 0 <br /> 4 W=>E Exterior Concrete Block-Ext Insul Main 4 1 8 0 8 0 64 0 ftZ 0 0 0.8 0 <br /> 5 NW=>SE Exterior Concrete Block-Ext Insul Main 4.1 48 4 8 0 386.7 ftz 0 0 0.8 0 <br /> _ 6 -=>SE Garage Frame-Wood Main 13 33 8 8 0 269.3 ft� 0 0.25 0.8 0 <br /> DOORS <br /> # Ornt DoorType Space Storms U-Value Width Height Area <br /> Ft In Ft In <br /> 1 NE=>SW Wood Main None .35 2 6 8 13.3 ftZ <br /> 2 SE=>NW Wood Main None .35 6 6 8 40.2ftZ <br /> 3 -=>SE Wood Main None .35 3 7 21 ft� <br /> WINDOWS <br /> Orientation shown is the entered orientation => changed to Worst Case. <br /> / Wall Overhang <br /> �� # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening <br /> 1 ne=>SW 1 Metal Low-E Double Yes 0.55 0.32 4.5 ftZ 1 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 <br /> 2 se=>NW 2 Metal Low-E Double Yes 0.55 0.32 44.2 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 <br /> 3 se=>NW 2 Metal Low-E Double Yes 0.55 0.32 10.7 ft2 7 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 <br /> 4 sw=>NE 3 Metal Low-E Double Yes 0.55 0.32 15.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 � <br /> j 5 w=>E 4 Metal Low-E Double Yes 0.55 0.32 22.5 ft2 4 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 <br /> 6 NW=>SE 5 Metal Low-E Double Yes 0.55 0.32 6.5 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 <br /> 7 NW=>SE 5 Metal Low-E Double Yes 0.55 0.32 30.0 ftZ 1 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 <br />� 8 NW=>SE 5 Metal Low-E Double Yes 0.55 0.32 53.3 ft2 8 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 <br /> GARAGE <br /> # FloorArea Ceiling Area E�osed Wall Perimeter Avg.Wall Height Exposed Wall Insulation <br /> 1 506 ftZ 506 ftZ 64 ft 8 ft 1 <br /> , INFILTRATION <br /> # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 <br /> 1 Wholehouse Best Guess .0003 1448.7 79.53 149.57 .2696 5.9018 <br /> HEATING SYSTEM <br /> # System Type Subtype Efficiency Capacity Block Ducts <br /> 1 Electric Heat Pump None HSPF 8.2 33.6 kBtu/hr 1 sys#1 <br /> 8/5/2015 2:37 PM EnergyGauge�USA-FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5 <br />