My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
16-17304
Zephyrhills
>
Building Department
>
Permits
>
2016
>
16-17304
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/1/2016 8:48:30 AM
Creation date
11/1/2016 8:45:31 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
16-17304
Building Department - Name
HIGHLAND HOLDINGS INC
Address
36126 SHADY BLUFF LP LOT 8
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM 405-10 <br /> Florida Code Compliance Checklist <br /> Florida Department of Business and Professional Regulations <br /> Residential Whole Building Performance Method <br /> ADDRESS� PERMIT#� <br /> , FL, <br /> - MANDATORY REQUIREMENTS SUMMARY-See individual code sections for full details. <br /> COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK <br /> Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed <br /> Recessed lighting IC-rated as meeting ASTM E 283. Windows and <br /> , doors= 0.30 cfm/sq.ft. Testing or visual inspection required. <br /> Fireplaces: gasketed doors &outdoor combustion air. Must complete <br /> envelope leakage report or visually verify Table 402.4.2. <br /> Thermostat& 403 1 At least one thermostat shall be provided for each separate heating <br /> controls and cooling system. Where forced-air furnace is primary system, <br /> programmable thermostat is required. Heat pumps with supplemental <br /> electric heat must prevent supplemental heat when compressor can <br /> meet the load. <br /> Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the <br /> primary air containment passageways for air distribution systems shall <br /> be considered ducts or plenum chambers, shall be constructed and <br /> sealed in accordance with Section 503.2.7.2 of this code. <br /> 403.3.3 Building framing cavities shall not be used as supply ducts. <br /> Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies <br /> in Table 403.4.3.2. Provide switch or clearly marked circuit breaker <br /> (electric) or shutoff(gas). Circulating system pipes insulated to = <br /> R-2+ accessible manual OFF switch. <br /> Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical <br /> ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. <br /> No make-up air from attics, crawlspaces, garages or outdoors adjacent <br /> to pools or spas. <br /> Swimming Pools 403 9 Pool pumps and pool pump motors with a total horsepower(HP) of= 1 <br /> &Spas HP shall have the capability of operating at two or more speeds. Spas <br /> and heated pools must have vapor-retardant covers or a liquid cover or <br /> other means proven to reduce heat loss except if 70% of heat from <br /> site-recovered energy. Off/timer switch required. Gas heaters <br /> minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool <br /> heaters minimum COP=4 0. <br /> Cooling/heating 403.6 Sizing calculation performed &attached. Minimum efficiencies per <br /> Tables 503.2.3 Equipment efficiency verification required. Special <br /> equipment occasion cooling or heating capacity requires separate system or <br /> variable capacity system. Electric heat>10kW must be divided into � <br /> two or more stages. <br /> Ceilings/knee walls 405.2.1 R-19 space permitting <br />�I <br /> 8/5/2015 2:37 PM EnergyGauge�USA-FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.