■ r�av��■ ■�v���rr�a <br /> Site Preparatlon <br /> POCKET PENETROMETER TEST <br /> 1500 Debris and organic material removed X <br /> . The pocket penetrometer tests are rounded down to psf Water drainage: Natural Swale Pad Other <br /> or check here to declare 1000 Ib. soil without testing. <br /> X 1500 X 1600 X 1700 Fastening multi wide units <br /> • Floor: Type Fastener: Length: Spacing: <br /> Walls: Type Fastener: Length: Spacing: <br /> POCKET PENETROMETER TESTING METHOD Roof: Type Fastener: Length; Spacing: <br /> For used homes a min.30 gauge,8"wide, palvanized metal strip <br /> 1, Test the perimeter of the home at 6 locations. will be centered over the peak of the roof and fastened with galv. <br /> roofing nails at 2"on center on both sides of the centerline. <br /> 2. Take the reading at the depth of the footer, <br /> G8Sk81(weetheraroo}Ina requlrementl <br /> 3, Using 500 Ib. increments, take the lowest <br /> reading and round down to that increment. I understand a properly installed gasket is a requirement of all new and used <br /> homes and that condensation, mold, meldew and buckled marriage walls are <br /> a result of a poorly installed or no gasket being installed. I understand a strip <br /> X 1600 X 1500 X 1500 of tape will not serve as a gasket. <br /> Installer's initials <br /> TORQUE PROBE TEST <br /> Type�asket Installed: <br /> The results of the torque probe test is inch pounds or check Pg. Between Floors Yes <br /> here if you are declaring 5'anchors without testing . A test Between Walls Yes <br /> showing 275 inch pounds or less will require 5 foot anchors, Bottom of ridgebeam Yes <br /> Note: A state approved lateral arm system is being used and 4 ft. <br /> anchors are allowed at the sfdewall locations. I understand 5 ft � weatherprooting <br /> anchors are required at all centerline tie points where the torque test <br /> reading is 275 or less and where the moblle home manufacturer may The bottomboard will be repaired and/or taped. Yes NA . Pg. <br /> requlres anchors with 4000 Ib holding capacity. Siding on units is installed to manufacturer's specifications, Yes�_ <br /> LLE Installer's init(als Fireplace chimney installed so as not to allow intrusion of rain water. Yes� <br /> _ ALL TESTS MUST BE PERFORMED BY A LICENSED IiVSTALLER Mlscellaneous <br /> Installer Name Lionel Easler Skirting to be installed. Yes No <br /> Dryer vent installed outside of skirting. Yes�_N/A <br /> Date Tested Range downflow vent installed outside of skirting. Yes N/A�_ <br /> Drain lines supported at 4 foot intervals. Yes X <br /> Electrical crossovers protected. Yes NA <br /> ' Other; <br /> Electrlcal <br /> Connect electrical conductors between multi-wide units, but not to the main power <br /> source. This includes the bonding wire between mult-wide units. Pg. NA <br /> Installerverifles all Informatlon given wlth this permlt worksheet <br /> um na ls accurate and true based on the <br /> manufacturer's lnstallation instructions and or Rule 15C-1 &2 <br /> Connect all sewer drains to an existing sewer tap or septic tank. Pg. <br /> Connect all potable water supply piping to an existing water meter,water tap, or other <br /> Installer Signature Date 4/26/16 <br />, independent water supply systems. Pg. <br />