My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
16-17395
Zephyrhills
>
Building Department
>
Permits
>
2016
>
16-17395
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/1/2016 10:04:07 AM
Creation date
11/1/2016 10:03:00 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
16-17395
Building Department - Name
RILEY,CHERYL
Address
5207 18TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
y <br /> • ' FI,9557.1-R3 <br /> C1999-1 <br /> . • 3.20.2015 <br /> Page 2 of 2 <br /> Manufacturer: Union Corrugating Company <br /> Product Name: MasterRib Panel <br /> Panel Description: 36"wide coverage with 3/4"high ribs at 9"o.c. <br /> Materials: Minimum 29 ga., 80 ksi steel. Galvanized coated steel (ASTM A653) <br /> or Galvalume coated steel (ASTM A792) or painted steel (ASTM <br /> A755). <br /> Support Description: Min 18 ga.,min 50 ksi steel supports.Must be designed by others <br /> Design Pressute: +45.35 and-37.7 psf @ support spacing of 48"o.c. <br /> (Based on testing) (@ 3 span condition with FS=2.0) <br /> Panel Attachment: #12-14 x 1"long self drilling screws with washers <br /> At panel ends @ 3.5"-5.5"-3.5"o.c.across panel width <br /> At intermediate @ 9"o.c.across panel width <br /> Sidelap Attachment: 1/4'-14 x 7/8" long SDS with washer @ 24"o.c. <br /> Test Standazds: Panel assembly tested in accordance with ASTM E1592-01 `Test <br /> Method for Structural Performance of Sheet Metal Roof and Siding <br /> Systems by Uniform Static Air Pressure Difference'. <br /> Code Compliance: The product described herein has demonstrated compliance with FBC <br /> 2014 Section 1404.5 <br /> Product Limitations: Design wind loads shall be determined for each project in accordance <br /> with FBC 2014 Section 1609 or ASCE 7-10 using allowable stress <br /> design. The maximum support spacing listed herein shall not be <br /> exceeded. The design pressure for reduced support spacing may be <br /> computed using rational analysis prepazed by a Florida Professional <br /> Engineer or based on Union Corrugating load span table. This product <br /> � is not approved for use in the High Velocity Hurricane Zone. <br /> Supporting Documents: ASTM E1592 Test Report <br /> ENCON Technology Inc. <br /> � C1514-1 (Test#1 &3),Reporting Date 9/S/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.